Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (25)
- Beitrag zu einem Tagungsband (25)
- Posterpräsentation (3)
- Vortrag (2)
- Forschungsbericht (2)
- Forschungsdatensatz (1)
Schlagworte
- Alkali-Kieselsäure-Reaktion (4)
- Betonfahrbahndecke (3)
- Ferroelektret (3)
- Haftfestigkeit (3)
- Luftgekoppelte Ultraschallprüfung (3)
- Phased Array (3)
- Steriltechnik (3)
- Adhesive strength (2)
- Air-coupled ultrasound (2)
- Bonding strength (2)
Organisationseinheit der BAM
- 6 Materialchemie (17)
- 6.1 Oberflächen- und Dünnschichtanalyse (10)
- 7 Bauwerkssicherheit (9)
- 6.7 Materialsynthese und Design (7)
- 7.1 Baustoffe (6)
- 8 Zerstörungsfreie Prüfung (6)
- 8.4 Akustische und elektromagnetische Verfahren (5)
- 7.2 Ingenieurbau (3)
- 6.2 Material- und Oberflächentechnologien (2)
- 4 Material und Umwelt (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (2)
In Glasfasern eingeschriebene Bragg-Gitter (FBG: fibre-based Bragg gratings) sind über die Verschiebung der Bragg-Wellenlänge in der Lage, Stauchungen und Dehnungen von Glasfasern hochgenau zu erfassen. In Kompositwerkstoffe eingebettete faseroptische Sensoren können Bauteile bezüglich ihrer mechanischen Integrität überwachen und früh-zeitig Informationen über Materialveränderungen gewinnen.
Um die Zuverlässigkeit eines solchen Sensors zu gewährleisten, ist es wichtig, die korrekte Funktion des Sensors im Verbund mit der Werkstoff-Matrix on-line und in-situ sicherzu-stellen. Im Rahmen des DFG-Projekts FAMOS² (FAser-basierter Magneto-Optischer SchichtSensor) wurde ein selbstdiagnosefähiger Schichtsensor entwickelt, der mit Hilfe von magnetostriktiven Aktorschichten aus Nickel bzw. Eisen-Nickel validiert werden kann.
Der FAMOS²-Schichtsensor wird durch ein PVD (physical vapour deposition)/ECD (electro-chemical deposition) Hybridschichtsystem realisiert, das auf dem Fasermantel im Bereich des FBG haftfest, homogen und langzeitfunktional abzuscheiden ist. Dabei wird in einem ersten Schritt ein etwa 100 Nanometer dünnes PVD-Schichtsystem aus Chrom und Kupfer als Haftvermittler auf der Glasfaser bzw. als leitfähige Startschicht für den nachfolgenden ECD-Prozess abgeschieden. Um eine rotationssymmetrische Schich-tabscheidung zu gewährleisten, erfolgt während der PVD-Beschichtung eine Rotation der Glasfasern. In einem zweiten Schritt wird dann unter Verwendung eines klassischen Watts-Elektrolyten in einer speziell entwickelten ebenfalls rotationssymmetrisch aufgebau-ten ECD-Durchströmungszelle dann die etwa 30 Mikrometer dicke, magnetostriktive Ak-torschicht auf dem PVD-Schichtsystem abgeschieden, im Vergleich sowohl reine Nickel-Schichten als auch Nickel-Eisen-Schichten.
Ein äußeres Magnetfeld dehnt die magnetostriktive Aktorschicht und damit auch die Faser reversibel. Diese Dehnung führt zu einer Verschiebung der Bragg-Wellenlänge, welche direkt mit der Stärke eines zu messenden oder zu Validierungszwecken vorgegebenen Magnetfeldes korreliert. Die Anpassung der Beschichtungsverfahren an die Fasergeome-trie und die mechanischen Eigenschaften der Hybridschichten werden hinsichtlich der me-chanischen Integrität des faseroptischen Sensors diskutiert und der Nachweis der Selbst-diagnosefähigkeit erbracht.
The new promoted ignition combustion test apparatus at BAM matches the requirements of ASTM test method G 124 [ASTM G 124, Standard Test Method for Determining the Combustion Behavior of Metallic Materials in Oxygen-Enriched Atmospheres, 2003] and of EIGA publication, IGC Doc 13/02/E [EIGA Gas Association Document IGC Doc 13/02/E, Oxygen Pipeline Systems, 2003]. The test apparatus is most likely the only one in Europe. The test chamber allows investigations with pure oxygen or oxygen mixtures at pressures up to 500 bar and at temperatures up to 400°C at static or flowing gas conditions. The ignition device consists of an electrical ignition wire and a promoter. IR-sensors, distributed over the whole length of the rod, measure and record the burning temperature and allow measurement of the burn rate. A video system records the experiment for visual characterization of the burning behavior. BAM test results are compared with published data. Results on investigations with coated rods are presented. Ceramic coatings seem to be a solution for the use of certain less compatible metallic materials at higher oxygen pressures.
Two different test apparatuses are used at BAM to evaluate the safety of oxygen components: First, the promoted ignition combustion test according to ASTM G 124 [1] and to EIGA IGC Doc 13/02/E [2], and second, the new metallic disk ignition test that has not been standardized yet. The standard test method ASTM G 124 allows a ranking of metallic materials for use at high pressure oxygen. However, the transfer of those test results to valves and fittings in real-life situations is rather complex. The metallic disk ignition test, developed at BAM, is more practice oriented and uses metallic disks of different thicknesses of the investigated material. A commonly used nonmetallic sealing ring is placed in front of this disk and serves as an igniter. This test array is then exposed to high pressure gaseous oxygen impacts in a standardized pneumatic impact tester according to DIN EN 1797 [3].
Functionality of optical systems requires optical coatings of
high quality which have to be adapted to the application in
terms of the performance of optical parameters such as
reflectivity (AR, low, defined, high), the substrate material of
interest (polymers, ceramics, and glass), the environmental
conditions (such as temperature or humidity), and the service
conditions (such spectral range and power density). Moreover,
in many cases, additional non-optical requirements have
to be met, including mechanical features such as scratch
resistance, hardness and modulus.
Consequently, thickness and overall uniformity requirements
are steadily increasing. In general, these demands can usually
not be achieved by a single film or coating. Instead, films with
specific design features (such as gradients), layer stacks and
multilayers are a prerequisite for high quality layers and their
reliability. For the development of such layer systems, a
versatile cluster deposition system consisting of three clusters
and a cluster-to-cluster handler has been designed. Besides a
PECVD cluster for DLC coatings, two PVD clusters implement
ion assisted electron beam evaporation and plasmabased
sputter technology. In addition to metallic films, preparation
of oxide and nitride optical coatings (SiO2, TiO2, Ta2O5,
ITO, Al2O3, TiN, AlN) in various process modifications (nonreactive,
partially reactive, full-reactive; rf-, dc-, mf- mode;
PEM control) has been carried out.
Within this paper, the effect of several process parameters on
layer quality (optical constants, density, and uniformity) is
discussed for selected applications examples (AR- and HR
coatings, applications at elevated temperatures and applications
of enhanced mechanical performance).
It has been shown that specific features of ion and plasma
assisted PVD processes, including ion-beam and plasma preand
post-treatment of substrates and layer systems, may
widen the application range and improve functionality features
of given coating/substrate systems.
The synthesis of polymerlike amorphous carbon (a-C:H) thin-films by microwave excited collisional hydrocarbon plasma process is reported. Stable and highly aromatic a-C:H were obtained containing significant inclusions of poly(p-phenylene vinylene) (PPV). PPV confers universal optoelectronic properties to the synthesized material. That is a-C:H with tailor-made refractive index are capable of becoming absorption-free in visible (red)-near infrared wavelength range. Production of large aromatic hydrocarbon including phenyl clusters and/or particles is attributed to enhanced coagulation of elemental plasma species under collisional plasma conditions. Detailed structural and morphological changes that occur in a-C:H during the plasma synthesis are also described.
Hydrogen-Containing Amorphous Carbon Layers as Optical Materials in the Near-IR Spectral Range
(2007)
Hydrogenated amorphous carbon layers were deposited on various substrates by means of a plasma CVD process with a RF substrate bias as well as an ECR plasma source. The optical properties of the a-C:H layers were obtained via spectroscopic ellipsometry and correlated with their mechanical and chemical properties. The layers from pure RF plasma exhibit a higher absorption constant in the visible spectral range and a higher refractive index. All layers are nearly transparent in the NIR spectral range making them candidates for optical thin layer systems. The laser damage behaviour of the a-C:H layers was investigated with ultrashort pulses. The damage thresholds were consistent with the absorption constants of the layers. Interesting damage morphologies were observed indicating a sensitivity of this experiment to sub-structures in the layer.
Multiple-sample approach: reliable ranking and validated statistics of bonding and adhesive strength
(2014)
Bonding strength of adhesive-bonded joints and adhesive strength of coatings have been exclusively determined in single-sample tests using a tensile testing machine. Necessarily, the single-sample approach was also applied to the corresponding bonding procedure. As a consequence, reliability and reproducibility of results were restricted. By applying the newly introduced centrifuge technology, the multiple-sample approach was realized for simultaneous tensile testing of up to eight samples under identical conditions without any disturbing shear-force effects. In order to introduce the multiple-sample approach into the bonding procedure, a hydraulic bonding set-up was developed which enables identical bonding pressure also for slightly different heights of sample assemblies. Both sample approaches were compared for various application examples: ranking of different classes of adhesives, validated statistics of adhesive-bonded joints using one particular adhesive and effects of cleaning and plasma-treatment on the adhesive strength of coatings. The investigated systems included glass, metals and polymer substrates, different adhesives, metallic and dielectric coatings on polymers.
Multiple-sample approach: reliable ranking and validated statistics of bonding and adhesive strength
(2014)
Bonding strength of adhesive-bonded joints and adhesive strength of coatings have been exclusively determined in
single-sample tests using a tensile testing machine. Necessarily, the single-sample approach was also applied to the
corresponding bonding procedure. As a consequence, reliability and reproducibility of results were restricted. By
applying the newly introduced centrifuge technology, the multiple-sample approach was realized for simultaneous
tensile testing of up to eight samples under identical conditions without any disturbing shear-force effects. In order to
introduce the multiple-sample approach into the bonding procedure, a hydraulic bonding set-up was developed which
enables identical bonding pressure also for slightly different heights of sample assemblies. Both sample approaches
were compared for various application examples: ranking of different classes of adhesives, validated statistics of
adhesive-bonded joints using one particular adhesive and effects of cleaning and plasma-treatment on the adhesive
strength of coatings. The investigated systems included glass, metals and polymer substrates, different adhesives,
metallic and dielectric coatings on polymers.
A novel approach for the generation of broadband airborne ultrasound by using the thermo-acoustic effect is presented in this contribution. We investigate the applicability of resonance-free thermo-acoustic emitters for generation of very short high pressure airborne ultrasound pulses. A thermoacoustic emitter consisting of a 30 nm thin metallic film on a usual soda-lime glass substrate generates sound pressure values of more than 140 dB at 60 mm distance. The results are compared with conventional piezoelectric airborne ultrasound transducers. Our investigations show the applicability of the thermo-acoustic devices for broadband and high pressure ultrasound emitters using pulse excitation.
Die Oberflächentechnik ist eine Schlüsseltechnologie in nahezu zu allen industriellen Branchen. Mit Ausnahme der mechanischen Stabilität, die das Substrat bereitstellt, werden verschiedenartigste Funktionen materialsparend, zum Teil hochintegriert mit maßgeschneiderten Schichtdesigns unter Ausnutzung von Nano- und Quanteneffekten auf Oberflächen appliziert. Ein Großteil der Fertigungskosten in der Mikro- und Nanotechnik wird durch Reinräume und die Umsetzung ausgeklügelter Reinigungsstrategien zur Vermeidung von Restverschmutzungen und partikulären Belegungen
verursacht, da diese unweigerlich zum Bauteilversagen führen. Die Validierung des Reinigungszustandes ist somit von zentraler Bedeutung für die Schichtqualität und Produktfunktionalität. Dies gilt in Abhängigkeit von der Applikation und den vertikalen Schicht- bzw. lateralen Strukturdimensionen sowohl für Fertigungsprozesse im Reinraum als auch für solche in robuster Umgebung. In der Praxis kommt es häufig vor, dass man mikroskopisch scheinbar saubere Substrate erst durch die Beschichtung „enttarnt" und dann Defekte oft mit bloßem Auge sichtbar werden. Noch problematischer ist der Einbau von Verunreinigungen während der Schichtabscheidung, die zunächst nicht sichtbar sind, dann aber zum Bauteilversagen führen.
Embedding of information on surfaces is state of the art for identification testing in which public, hidden and forensic features are used. In many instances, the legal authentication of a product, a material or a document is required. Among the surface-based encoded labels, bar codes and data matrices are most frequently applied. They are publicly visible. The material itself is irrelevant, only a sufficient optical contrast is required.
However, a strong material dependence of the label can be achieved by means of Fabry-Perot layer stacks. Stack designs are described with regard to all three security levels: public features (e.g. color and tilt effect) perceptible by the human eye, hidden features (e.g. optical response in a given spectral range) detectable by commonly available instruments and forensic features (ellipsometric quantities Ψ and Δ as a function of wavelength λ and angle of incidence AOI) only detectable by sophisticated instruments.
Regarding material-correlated authentication, ellipsometric quantities Ψ and Δ are used as encoded forensic features for the first time. Hence, Fabry-Perot layer stacks as information carriers in combination with imaging ellipsometry as optical read-out system provide all-in-one anti-counterfeiting capabilities.
Standardised conventional adhesion tests are time-consuming single-sample tests. Moreover, except for the pull-off test, all these tests provide only qualitative or semi-quantitative (ranking, respectively measurement of an adhesion-correlated quantity) information on adhesion. Sometimes, adhesion is evaluated even under compressive stress conditions (e.g. cross-cut and scratch test), which itself is a contradiction to adhesive strength as defined in terms of tensile force per area.
For optical coatings it has been shown that the pull-off test in a centrifuge is definitely a promising alternative with respect to the reliable, fast and quantitative determination of adhesive strength in N/mm2. The force-controlled centrifuge test is the only multiple-sample test which provides reliable quantitative information on the adhesive strength in agreement with DIN EN 15870 and DIN EN ISO 4624 on a statistical basis for up to eight samples simultaneously tested under identical testing conditions.
Most of the polymeric materials used are easy to ignite and show extensive flame spread along their surfaces. Apart from extensive heat release rates, their short time to ignition (tig), in particular, is a key fire hazard. Preventing ignition eliminates fire hazards completely. Protection layers that shift tig by more than an order of magnitude are powerful flame retardancy approaches presenting an alternative to the usual flame retardancy concepts.
Coatings are proposed that consist of a three-layer system to ensure adhesion to the substrate, acting as an infrared (IR) mirror and protecting against oxidation. The IR-mirror layer stack is realised by physical vapour deposition in the sub-micrometre (<1 µm) range, reducing heat absorption by up to an order of magnitude. Not only is the ease of ignition diminished (tig is increased by several minutes), the flame spread and fire growth indices are also remarkably reduced to as little as 1/10 of the values of the uncoated polymers open for further optimization. Sub-micrometre thin IR-mirror coatings yielding surface absorptivity <0.1 are proposed as a novel and innovative flame retardancy approach.
In this contribution we present a novel thermo-acoustic approach for the generation of broad band airborne ultrasound and investigate the applicability of resonance-free thermo-acoustic emitters for very short high pressure airborne ultrasound pulses. We report on measurements of thermo-acoustic emitter consisting of a 30 nm thin metallic film on a usual soda-lime glass substrate, generating sound pressure values of more than 140 dB at 60 mm distance from the transducer and compare the results with conventional piezoelectric airborne ultrasound transducers. Our experimental investigations show that such thermo-acoustic devices can be used as broad band emitters using pulse excitation.
Auf dem Weg zu Industrie 4.0: Bestimmung von Messunsicherheitsbudgets in der Oberflächentechnik
(2019)
Vorgestellt wurde die Bestimmung von Messunsicherheitsbudgets für sehr unterschiedliche physikalische Größen, die in der Oberflächentechnik von hoher Relevanz sind: Stufenhöhe h, Schichtdicke d, Eindringhärte HIT und Haftfestigkeit. Die Unterschiede betreffen die Art der Prüfmethodik (optisch zerstörungsfrei vs. mechanisch invasiv/zerstörend), die laterale Größe des Integrationsgebietes der Messung (lokal: nano bis sub-mikro vs. global: mikro bis makro) und die Art der Bestimmung von Messunsicherheitsbudgets (physikalische Größen: direkt rückführbar; Werkstoffkenngröße: genormt; Systemkenngröße: genormt).
Im Rahmen von Industrie 4.0 werden ausgehend der geforderten Spezifikation des beschichteten Produkts (Mittelwert mit Vertrauensbereich oder Mindestwert) durchgehende Toleranzbänder zur Oberflächenmodifizierung/Beschichtung des Substrats, einhergehend mit Prozessfenstern, die diese Toleranzbänder garantieren, erforderlich, die zuverlässig erfasst werden müssen. Die Frage der anzuwendenden Mess- und Prüftechnik und die damit notwendige Betrachtung von Messunsicherheitsbudgets ist für die Digitalisierung von Konditionierungs-, Zustands-, Regel- und Steuergrößen unverzichtbar. Mit Blick auf die Einhaltung von Prozessfenstern und die dafür notwendige Prozessführung wird technologisches Kern-Know-how digitalisiert, das es unbedingt zu schützen gilt. Nur lokale Netze können diese Sicherheit garantieren, in globalen Netzen ist die Datensicherheit bestenfalls maximierbar
The growing interest in artificial bioorganic Interfaces as a platform for applications in emerging Areas as personalized medicine, clinical diagnostics, biosensing, biofilms, prevention of biofouling, and other fields of bioengineering is the origin of a need for in Detail multitechnique characterizations of such layers and interfaces. The in-depth analysis of biointerfaces is of special interest as the properties of functional bioorganic coatings can be dramatically affected by in-depth variations of composition.
In worst cases, the functionality of a device produced using such coatings can be substantially reduced or even fully lost.
Public, hidden, and forensic features either encoded or directly legible are used for authentication. Fabry-Perot layer stacks as information carriers in combination with imaging ellipsometry as optical read-out system provide all-in-one anti-counterfeiting capability that may establish the new security level 'encoded forensic'. Different layer designs are described with regard to all three security levels: public features (e.g. color and tilt effect) perceptible by the human eye, hidden features (e.g. spectroscopic response in the UV or IR), and forensic features (ellipsometric quantities Ψ and Δ as a function of wavelength λ and angle of incidence AOI). Physically uncloneable functions (PUF) could be realized as a result of a multi-material and a multi-parameter deposition approach as well as by means of specific design features of the Fabry-Perot layer stack. Hence, they are not subject to any reverse engineering strategies. Examples of stratified, micro-structured, and laser-modified Fabry-Perot layer systems are considered that may be used at all perception levels (e.g. human eye, bar code reader, and imaging ellipsometry) for authentication against product counterfeiting and related areas. --------------------------------------------------------------------------------------------------------------------
Zur Authentifizierung werden offene, versteckte und forensische Merkmale entweder codiert oder direkt auslesbar verwendet. Mit Fabry-Perot Schichtsystemen als Informationsträger in Kombination mit der abbildenden Ellipsometrie als optischem Auslesesystem steht ein 'all-in-one' Fälschungsschutz-System zur Verfügung, das ein neues Sicherheitsniveau 'kodiert-forensisch' darstellt. Es werden unterschiedliche Schichtdesigns beschrieben, mit denen alle drei Sicherheitsniveaus realisiert werden können: offene Merkmale (z.B. Farbe und Kippeffekt), die mit dem menschlichen Auge wahrnehmbar sind, versteckte Merkmale (z.B. die spektrale Antwort im Sichtbaren oder im IR) sowie forensische Merkmale (ellipsometrische Größen Ψ und Δ als Funktion der Wellenlänge λ und des Einfallswinkels AOI).
Physikalisch nicht klonbare Funktionen (PUF) können im Ergebnis einer Multi-Material- und Multi-Parameter Beschichtungsstrategie sowie durch spezifische Design-Merkmale des Fabry-Perot Schichtsystems realisiert werden. Folglich sind solche Schichtsysteme dem 'reverse engineering' nicht zugänglich. Es werden Beispiele für lateral ausgedehnte, mikrostrukturierte und Laser modifizierte Schichtsysteme auf verschiedenen Ausleseniveaus (menschliches Auge, Barcode-Lesegerät, abbildendes Ellipsometer) vorgestellt, die zur Authentifizierung von Produkten und verwandte Gebiete geeignet sind.
The extremely low acoustic impedance of polypropylene ferroelectret combined with its piezoelectric properties makes this material suitable for construction of aircoupled ultrasonic transducers for non-destructive testing. For the fabrication of transducers with a stable quality, the reproducibility of their key parameters is of interest.
The reproducibility was evaluated by means of (i) impedance spectroscopy and (ii) pulse-echo measurements. (i) Impedance spectroscopy was applied to identify the resonance frequency, the coupling factor and the acoustic impedance of several nominally identical transducers. (ii) Pulse-echo measurements yielded the signal form of these transducers.
The variation of the signal amplitude measured with pulseecho technique was about 10 dB. A part of this variation Comes from the deposition of transducer electrodes and another part from local variations of ferroelectret properties. The variation of the signal amplitude was caused by the observed variation of the coupling factor, which was also about 10 dB. The variation of the acoustic impedance was only about 1 dB, thus having no effect on the variation of the signal amplitude.
These results indicate that the variability can be reduced by improving the control of electrode deposition and by optimizing the production technology affecting the reproducibility of material properties.
Reinigung wird in der Lebensmittel- und Pharmaindustrie aufgrund des stetig steigenden Kosten- und Zeitdrucks sowie der hohen Verbrauchererwartungen hinsichtlich Produktsicherheit und -haltbarkeit ein immer zentraleres Thema. Eine verbesserte Reinigbarkeit bedeutet für die produzierende Industrie eine Steigerung der Effizienz der Produktionsanlage. Besonders in der heutigen medienintensiven Zeit kommt ein "Lebensmittelskandal" durch ein unsicheres Produkt einem finanziellen Desaster und immensem Imageverlust gleich. Aus diesem Grund ist die Reinigbarkeit der produktberührenden Oberflächen stets ein wichtiges Kriterium für die Werkstoffauswahl.
Basierend auf den Theorien zu Schmutzhaftung und -entfernung wurde im Rahmen dieser Arbeit überprüft, ob und wie die theoretisch relevanten Parameter auch in den Experimenten den Reinigungserfolg beeinflussen. Der Schwerpunkt wurde auf die Einflussgrößen des Werkstoffes gelegt, um herauszufinden, wie stark eine Oberfläche selbst zu ihrer Reinigbarkeit beitragen kann (self-cleaning).
In den durchgeführten Versuchen hat sich gezeigt, dass die Oberflächenrauheit lediglich bei der Reinigung von kohäsiven Schmutzfilmen eine entscheidende Rolle gespielt hat. Hingegen ist ihr Einfluss auf das Reinigungsergebnis von sich auflösenden Schmutzfilmen und Partikeln nur begrenzt bis gar nicht zur Geltung gekommen. Das Oberflächenmaterial hatte keinen starken, aber dennoch signifikanten Einfluss auf die Reinigbarkeit der untersuchten Oberflächen. Dass die Reinigbarkeit einer Oberfläche keine Materialkonstante sein kann, wurde unter Verwendung spezieller Oberflächen mit definiert geätzten Rauheitsstrukturen nachgewiesen. Der Reinigungserfolg hängt immer auch von der Verunreinigungsart ab, was sich auch in vergleichbaren Versuchen der Einzelpartikelablösung mittels AFM in dem Einfluss der Elastizität bzw. Plastizität der Partikeln geäußert hat.
Praxistaugliche Empfehlungen gehören mit zu den wichtigsten Zielen dieser Arbeit gewesen. Mit Fokus auf die Oberflächenparameter und auf Basis der durchgeführten Untersuchungen wurde zur Optimierung der Reinigung produktberührender Oberflächen für bekannte Kontaminationen eine Checkliste als Orientierungshilfe erarbeitet. Ist die Verunreinigungsart dennoch unbekannt, so sollte der "Grenzwert" von Ra = 1 µm unterschritten werden, um bei Vorhandensein filmartiger Verschmutzungen keine negativen Auswirkungen auf die Reinigbarkeit zu haben. Die Notwendigkeit nach hochpolierten Oberflächen (Ra < 0,3 µm) aus Reinigbarkeitsgründen kann aufgrund der Untersuchungen nicht nachvollzogen werden.
Das Ziel des Vorhabens wurde erreicht.
Fluid-assisted mass transport reactions by dissolution-precipitation, where a precursor mineral reacts with a fluid, play an important role in metamorphism and metasomatism. We investigated titanite growth on rutile in time series experiments between one and 107 days at constant P-T conditions of 600 °C and 400 MPa in the system TiO2-CaO-SiO2-Na2O-HCl-H2O. A two-capsule assemblage allows for transport of Ca and Si from dissolving wollastonite to dissolving rutile, the Ti-source, in a NaCl-bearing aqueous fluid, according to the general reaction CaSiO3 + TiO2 = CaTiSiO5. Complete overgrowth of rutile by titanite occurred after just one day of experiment. Fine-grained lozenge-shaped titanite crystals of short-time runs (up to 14 days) reorganize to larger predominantly prismatic crystals after >14 days.
After investigation by scanning electron microscopy, the titanite overgrowth was removed from the rutile by hydrofluoric acid, to provide a three-dimensional view of the dissolution-reaction front on the rutile surface. The morphology of the rutile surface is dominated by humps or ridges beneath the central region of a titanite crystal and valleys at the grain boundaries between adjacent titanite crystals. The dissolution pattern on the rutile surface mimics the titanite overgrowth and changes with changing grain size and shape of the titanite with longer run times. The preferred dissolution of rutile in the valleys is clearly linked to the position of the titanite grain boundaries, which served as pathways for fluid-assisted element transport. Rutile-titanite and titanite-titanite boundaries show a significant porosity in transmission electron microscopy images of foils prepared by focused ion beam milling. The large-scale dissolution pattern on the rutile surface is independent of the crystallographic orientation of the rutile and entirely dominated by the arrangement of titanite crystals in the overgrowth. Dissolution features on a scale smaller than ~1 µm are dominated by stepwise dissolution and etch-pits following the crystallographic orientation of the rutile. Similar observations were made in experiments with an additional Al-source, although these experiments result in a different overgrowth pattern; i.e., an exposed rutile surface is always present and solitary titanite crystals are accompanied by partial overgrowths. Quantitative characterization of the surface morphology by white-light interference microscopy demonstrates that, with increasing grain size of titanite, dissolution of rutile is strongly enhanced at the titanite grain boundaries.
Natural examples of titanite overgrowths on rutile show the same relations between element pathways, arrangement of titanite crystals and 3D dissolution pattern on rutile as in the experimental systems. We conclude that the transport of Ti away from the rutile and of Ca + Si into the reaction rim occurred in a grain boundary fluid, the composition of which must have been strongly different from the composition of the bulk fluid in the experiment, as well as in the natural system. The reaction progress depends on the availability of a fluid, and relicts of rutile in titanite indicate restricted availability of fluid in the natural system (e.g., a fluid pulse that was consumed by the reactions). The reaction examined here can serve as a proxy for other reactions of the conversion of oxide minerals (e.g., spinel or corundum) into silicates.
The irradiation of ~0.9-µm-thick hydrogenated amorphous carbon (a-C:H) layers deposited on silicon substrates with single femtosecond (fs) laser pulses (35 fs pulse duration, 790 nm centre wavelength) in air is studied experimentally. Irradiation spots have been generated with different peak fluences and subsequently investigated by optical topometry, micro Raman spectroscopy and microscale mechanical indentation in order to evaluate their microscopic, topographical, structural and mechanical properties (e.g. elastic modulus). By this multi-method approach, a clear separation of different effects (delamination and graphitisation) becomes possible. The joint application of mechanical and spectroscopic techniques provides unique insights into the effects of the fs-laser radiation on the carbon layer.
Hydrogenated amorphous carbon layers were deposited on BK7 glass in a plasma-assisted chemical vapor deposition
process. Low and high refracting films with thicknesses d ranging from 11 nm to 5.8 µm were produced having refractive
indices n between 1.68 and 2.41 and linear absorption coefficients of α~100 cm-1 and α~20000 cm-1 at 800 nm wavelength as a result of different plasma modes. Laser ablation thresholds Fth in dependence on d were determined using 30-fs laser pulses. Low absorbing layers show a constant Fth while Fth increases with rising d up to the optical penetration depth of light α-1 for high absorbing films.
Novel air-coupled ultrasonic transducer combining the thermoacoustic with the piezoelectric effect
(2016)
In recent years, there has been an increasing industrial demand for one-sided inspection of various structures by means of air-coupled ultrasonic technique. Lightweight structures based on carbon-fibre-reinforced polymers may have very complex shapes, making air-coupled transmission difficult or even impossible. The inspection of concrete structures is another example where one-sided inspection is required.
To address these challenges a new type of transducer for air-coupled pulse-echo inspection was developed, which unites two principles: thermoacoustic emission and piezoelectric reception. The thermoacoustic emitter is a titanium electrode with a thickness of several tens of nanometer. This electrode was deposited onto charged cellular polypropylene, which serves as a piezoelectric receiver. The thermoacoustic transmission is based on a transformation of the thermal energy of an electrically heated electrode into the acoustic energy of an ultrasonic wave. Thermoacoustic emitters provide resonance-free behaviour and thus extremely broadband pulses. Charged cellular polypropylene is piezoelectric due to the polarization of its cells and it is well matched to air, with a Young modulus in the order of magnitude of MPa. In this contribution we present some pulse-echo measurements with the first prototypes of the combined thermoacoustic-piezoelectric transducer.
3D coherence scanning interferometry (CSI) is anoptical, non-contact and rapide measurement technique using a defined bandwidth of white light at normal incidence. White light interference microscopy (WLIM) providest here-dimensional surface topometry data up to a resolution of 0.4 µm lateral and 0.1 nm vertical. Three operating modi, surface, films and advanced films, enable measurements of step heights, roughness, wear volume, cone angle, surface pattern and layer thickness. Traceability to SI system is ensured by certified standards (PTB/NIST) within a DAkkS DIN EN ISO/IEC 17025:2018 accredited lab.
Verstärkt auftretende Schäden in Betonfahrbahndecken des Bundesfernstraßennetzes, die mit einer Alkali-Kieselsäure-Reaktion (AKR) in Verbindung gebracht werden, haben zu einer massiven Verschärfung der Prüfvorschriften zur Bewertung der Alkaliempfindlichkeit von Ge-steinskörnungen geführt. Die damit verbundene Einschränkung potenziell für den Straßenbau einsetzbarer Gesteinskörnungen ruft eine verstärkte Ressourcenknappheit und ein erhöhtes Transport- und damit einhergehendes Kostenaufkommen hervor. Vor diesem Hintergrund wird nach neuartigen AKR-Vermeidungsstrategien gesucht, die auch eine Verwendung grenzwertig alkaliempfindlich eingestufter Gesteinskörnungen erlaubt. Einen möglichen Lösungsansatz stellt in diesem Kontext die Innenhydrophobierung des Fahrbahndeckenbetons dar. Es soll so durch die Behinderung des Feuchte- und Tausalzeintrags in den Beton der AKR-Schädigungs-prozess signifikant vermindert werden. Für die Bewertung der Leistungsfähigkeit der Innen-hydrophobierung zur Vermeidung einer schädigenden AKR in Betonfahrbahndecken wird zur-zeit im Auftrage der BASt an der BAM ein Forschungsvorhaben bearbeitet. Im Rahmen dieses Beitrags werden erste ausgewählte Ergebnisse dieses Forschungsvorhabens vorgestellt. So wird exemplarisch an einem Oberbeton (0/8) mit einer alkaliempfindlichen Gesteinskörnung der Einfluss eines Hydrophobierungsmittels auf die Frisch- und Festbetoneigenschaften ganz-heitlich aufgezeigt und bewertet. Bei Letzteren stehen zunächst die mechanischen und hygri-schen Parameter sowie der Frost-Tausalzwiderstand im Vordergrund. In einem weiteren Schritt wird der Einfluss der Innenhydrophobierung auf die schädigende AKR mittels verschie-denartiger AKR-Performanceprüfungen beleuchtet.
To prevent future alkali-aggregate reaction (AAR) damage, which has occurred frequently in the Germanhighway network in recent years, a new regulation has been drafted. This regulation severely limits the use of alkali-sensitive aggregates by requiring that their suitability be verified by certified inspectors using newly developed AAR concrete tests that involve the external supply of alkali. This has led to a significant limitation in the number of aggregates usable for concrete pavements. A novel AAR avoidance strategy is now being pursued, which aims to enable the use of borderline alkali-sensitive aggregates through the application of an internal water-repellent treatment. The addition of water repellents during concrete production should significantly reduce the ingress of water and external de-icing salts into the concrete pavement, thus reducing the potential for AAR damage.
This paper presents the results of laboratory tests to assess the suitability of this new AAR prevention strategy. Representative, highly AAR-susceptible road paving concrete made with an alkali- sensitive greywacke and various water repellents were used as the basis for these experiments. The tests for concrete suitability included determining the conventional fresh and hardened concrete properties as well as concrete prism tests with external alkaline supply. Building on these results, laser-induced breakdown spectroscopy (LIBS) analyses of de-icing-salt intrusion as well as microscopic examinations for verification of the AAR characteristics were carried out.
The results of the AAR concrete tests with external alkaline supply support the conclusion that, when hydrophobic agents containing a suitable active ingredient are used, the AAR damage process in road paving concrete can be sufficiently prevented.
Um die zunehmenden AKR-Schäden an Betonfahrbahnen im deutschen Autobahnnetz zukünftig zu vermeiden, wurden mit dem ARS 04/2013 verbindliche Eignungsprüfungen zum Ausschluss alkaliempfindlicher Gesteinskörnungen bei Neubau- und Erhaltungsmaßnahmen eingeführt. Dies führte zu einer deutlichen Reduzierung der geeigneten Gesteinskörnungen. Vor diesem Hintergrund soll durch die Zugabe eines Innenhydrophobierungsmittels während der Betonherstellung grenzwertig alkaliempfindliche Gesteinskörnung nutzbar gemacht werden.
Die AKR-Vermeidungsstrategie basiert dabei auf der signifikanten Reduzierung des Eindringens von Wasser und Tausalzlösung in den Fahrbahndeckenbeton. In einem im Aufträge der BASt an der BAM durchgeführten Forschungsvorhaben wurde die Leistungsfähigkeit verschiedener Hydrophobierungsmittel für diesen Einsatzzweck
grundhaft untersucht. In dem Beitrag wird exemplarisch die Leistungsfähigkeit eines geeigneten Hydrophobierungsmittels in einem Waschbeton mit einer sehr alkaliempfindlichen Grauwacke aufgezeigt. Das Spektrum der Laboruntersuchungen reicht dabei von AKR-Betonversuchen mit Alkalizufuhr sowie den aufbauend durchgeführten mikroskopischen Untersuchungen zur Bewertung des AKR-Schädigungspotenzials über die Analyse des Feuchte- und Tausalzeintrags bis zur Ermittlung der mechanischen Eigenschaften und des Frost-Tausalz-Widerstands.
Abschließend wird der noch vorhandene Forschungsbedarf zur Überführung dieser neuen AKR-Vermeidungsstrategie in die Praxis aufgezeigt.
Alkali-silica reaction (ASR) is a chemical reaction within concrete which can lead over time to cracking and spalling. Due to the complexity of the problem, it still causes damage to concrete constructions worldwide.
The publication aims to illustrate the interdisciplinary research of the German Federal Institute for Materials Research and Testing (BAM) within the last 20 years, considering all aspects of ASR topics from the macro to the micro level. First, methods for characterization and assessment of ASR risks and reaction products used at BAM are explained and classified in the international context. Subsequently the added value of the research approach by combining different, preferably nondestructive, methods across all scales is explained using specific examples from a variety of research projects. Aspects covered range from the development of new test-setups to assess aggregate reactivity, to analysis of microstructure and reaction products using microscopical, spectroscopical and X-ray methods, to the development of a testing methodology for existing concrete pavements including in-depth analysis of the visual damage indicator and the de-icing salt input using innovative testing techniques. Finally, research regarding a novel avoidance strategy that makes use of internal hydrophobization of the concrete mix is presented.
3D coherence scanning interferometry (CSI) is an optical, non-contact and rapide measurement technique using a defined bandwidth of white light at normal incidence. Based on this operational principle, white light interference microscopy (WLIM) provides three-dimensional surface topometry data up to a resolution of 0.4 μm lateral and 0.1 nm vertical. Three operating modi, i.e. surface, films and advanced films, enable measurements of step heights, roughness, wear volume, cone angle, surface pattern and layer thickness of transparent coatings.
The determination of layer thickness by WLIM requires the knowledge of optical constants, i.e.the refractive index n and the extinction coefficient k. For technical surfaces, data base values - if available at all - have to be determined or validated by spectroscopic ellipsometry (SE). From this oblique incidence technique both optical constants and layer thickness can be derived based on a model for at least semi-transparent coatings. For different layer thicknesses, a
comparison is made between WLIM and SE. Measurement uncertainty is
discussed for both topometric features and layer thickness for different use cases.
Traceability to SI system is ensured by certified standards (PTB/NIST) within a DAkkS DIN EN ISO/IEC 17025:2018 accredited lab.
Biofilms cause complications and high costs in both industry and medicine. Of particular interest are bacterial infections of prosthetic materials, which usually cannot be eliminated due to the high antibiotic resistance known for bacteria forming biofilms. The search for new materials and coatings with lower colonization potential and antibacterial activity is of great importance to reduce biofilm formation. However, there is no standardized procedure to examine the colonization characteristics of bacteria in the Biofilm state in situ. Here, we describe an automated epifluorescence microscopy system for the semi-quantitative analysis of three-dimensional (3D) biofilms on various surfaces. To analyze adherent bacteria, three materials (glass, steel and titanium) were incubated with bacteria in a flow chamber system. After fluorescence staining of the bacteria, automated image capturing, quantification of the bacteria, measurement of the colonized area and determination of the 3D biofilm height were carried out by using novel software.
Furthermore, the materials were examined for their surface topography using white light scanning interferometry. Titanium compared to glass showed a significantly higher number of adherent bacteria.
We argue that this was due to the higher microroughness of titanium. The colonized area was in accordance with the number of adherent bacteria and was also significantly larger on titanium coupons compared to glass. Maximum 3D biofilm height on glass coupons was significantly lower compared to the ones on steel and titanium. This novel method enables the standardized, automated investigation of the colonization with bacteria on different materials. This approach can considerably support the characterization of new material surfaces and their innovative coatings by analyzing the amount of attached Bacteria and thickness of biofilms in situ and eliminates the need of conventional cultivation.
Deep understanding of the effects associated with fabrication parameters and their influence on the resulting structures shape is essential for the further development of direct laser writing (DLW). In particular, it is critical for development of reference materials, where structure parameters are precisely fabricated and should be reproduced with use of DLW technology. In this study we investigated the effect of various fabrication and preparation parameters on the structural precision of interest for reference materials. A well-studied photo-curable system, SZ2080 negative photo-resist with 1 wt.% Michler's ketone (Bis) photo-initiator, was investigated in this work. The correlation between applied laser power, laser velocity, fabrication direction on the deviations in the structure shape were observed by means of white light interferometry microscopy. Moreover, influence of slicing and hatching distances as well as prebake time were studied as function of sample shape. Deviations in the structure form between the theoretically expected and the one detected after DLW fabrication were observed in the range up to 15%. The observed shape discrepancies show the essential importance of fine-tuning the fabrication parameter for reference structure production.
Hybrid optical measurement technique for detection of defects in epitaxially grown 4H-SiC layers
(2022)
Recent developments in power electronics require the use of new wide bandgap compound semiconductor. We demonstrate the use of the ellipsometry and white light interference microscopy to detect defects in epitaxially grown SiC layers on SiC substrates. Such hybrid optical metrology methods can be used to better understand the mechanism of the development of the defects as well as their effects on the material´s optoelectronic properties.
Seit Jahren stellt die luftgekoppelte Ultraschallprüfung eine etablierte Alternative zur konventionellen Prüfung von Leichtbaukomponenten aus den Bereichen Luft- und Raumfahrt sowie Automotive dar. Im Gegenteil zur flüssigkeitsgekoppelten Prüfung in Kontakt oder im Tauchbecken ist sie weniger invasiv und bietet daher zeitliche und finanzielle Anreize.
Normalerweise wird die luftgekoppelte Prüfung mit Einzelelementschwingern in Durchschallung realisiert, wohingegen die Gruppenstrahlertechnik bereits Industriestandard im Bereich der Kontakttechnik darstellt. Die damit verbundenen Vorteile wie die aktive Fokussierung oder, die gezielte Manipulation des Einschallwinkels zur Anregung von geführten Wellen, finden im Bereich der luftgekoppelten Prüfung dabei noch wenig Anwendung.
Im Rahmen dieses Beitrags stellen wir die ersten Zwischenergebnisse des geförderten Projektes „PALUP – Phased- Array-Technik für Luftultraschall-Prüfungen“ vor. Ziel des Projektes ist die Entwicklung von Mehrelementschwingern auf Basis von zellulären Kunststoffen, die Entwicklung einer dedizierten Pulserstufe im Kilovoltbereich, sowie die nötige rauscharme messtechnische Auswertung jedes Einzelelements.
Seit Jahren stellt die luftgekoppelte Ultraschallprüfung eine etablierte Alternative zur konventionellen Prüfung von Leichtbaukomponenten aus den Bereichen Luft- und Raumfahrt sowie Automotive dar. Im Gegenteil zur flüssigkeitsgekoppelten Prüfung in Kontakt oder im Tauchbecken ist sie weniger invasiv und bietet daher zeitliche und finanzielle Anreize.
Normalerweise wird die luftgekoppelte Prüfung mit Einzelelementschwingern in Durchschallung realisiert, wohingegen die Gruppenstrahlertechnik bereits Industriestandard im Bereich der Kontakttechnik darstellt. Die damit verbundenen Vorteile wie die aktive Fokussierung oder, die gezielte Manipulation des Einschallwinkels zur Anregung von geführten Wellen, finden im Bereich der luftgekoppelten Prüfung dabei noch wenig Anwendung.
Im Rahmen dieses Beitrags stellen wir die ersten Zwischenergebnisse des geförderten Projektes „PALUP – Phased- Array-Technik für Luftultraschall-Prüfungen“ vor. Ziel des Projektes ist die Entwicklung von Mehrelementschwingern auf Basis von zellulären Kunststoffen, die Entwicklung einer dedizierten Pulserstufe im Kilovoltbereich, sowie die nötige rauscharme messtechnische Auswertung jedes Einzelelements.
Bewertung der Innenhydrophobierung von Fahrbahndeckenbetonen als neuartige AKR-Vermeidungsstrategie
(2022)
Zur Nutzbarmachung grenzwertig alkaliempfindlicher Gesteinskörnungen für Betonfahrbahndecken wurde basierend auf einer Literaturrecherche die Eignung von je einem Innenhydrophobierungsmittel auf der Basis eines Kalziumstearats (HM-A), eines Silan-Siloxan-Gemisches (HM-B) sowie eines der Vertraulichkeit unterliegenden Wirkstoffs (HM-C) für die neuartige AKR-Vermeidungsstrategie untersucht. Die Basis für die Eignungsuntersuchungen bildeten die Rezepturen im ARS 04/2013 für den OB (D>8)/UB sowie für den OB 0/8. Zur Herausarbeitung des Einflusses des Hydrophobierungsmittels auf die schädigende AKR fand in der groben Kornfraktionen ein alkaliempfindlicher Grauwackesplitt Anwendung. Aufgrund der unterschiedlichen Wechselwirkung zwischen dem LP-Bildner und dem Hydrophobierungsmittel wurde seine Dosierung beim HM-A reduziert sowie beim HM-B geringfügig und beim HM-C um ein Vielfaches erhöht.
Ausgehend von den ausgewählten Rezepturen mit den unterschiedlichen Hydrophobierungsmitteln wurden bei den Untersuchungen u.a. folgende Erkenntnisse gewonnen:
• Nachweis der Funktionalität aller drei Hydrophobierungsmittel im Festbeton durch signifikant reduzierte kapillare Aufnahme der Prüflösung.
• Verschlechterung der mechanischen Eigenschaften und des Frost-Tausalzwiderstands des OB (D>8)/UB bei Zugabe aller Hydrophobierungsmittel.
• Verzicht auf den Einsatz des HM-A im OB (D>8)/UB aufgrund drastischer Verschlechterung der Verarbeitbarkeit des Frischbetons und hohem Festigkeitsverlust.
• Verzicht auf den Einsatz des HM-B im OB (D>8)/UB aufgrund der Überschreitung des Dehnungsgrenzwerts nach dem 9. bzw. 10. Zyklus (mit bzw. ohne zyklischer Vorschädigung) und der einhergehenden starken Abwitterung bei der KWL mit NaCl-Lösung.
• Nachweis nachhaltiger Verminderung schädigender AKR in beiden Betonarten mit HM-C in Klimawechsellagerung und 60°C-Betonversuch mit externer Alkalizufuhr, allerdings zu Lasten der mechanischen Eigenschaften und des Frost-Tausalz-Widerstands.
Fazit: Bei geeigneter Wirkstoffauswahl hat die Innenhydrophobierung das Potenzial für die Nutzbarmachung grenzwertiger Gesteinskörnung. Ihre Überführung in die Praxis erfordert jedoch eine weitere ganzheitliche Optimierung der Baustoffperformance. Das schließt auch die Verifizierung gezielter betontechnologischer Maßnahmen zur Verminderung der Verschlechterung der mechanischen Eigenschaften und des Frost-Tausalz-Widerstandes ein.
Die üblichen Verfahren der zerstörungsfreien Prüfung mit Ultraschall basieren auf der Verwendung von flüssigen Koppelmitteln. Luftgekoppelte Prüfung setzt sich gegen die konventionellen Verfahren durch, wenn die Flüssigkeit nicht erwünscht oder den Prüfling gar beschädigen kann. Zwei Technologien für Erzeugung von Ultraschallsignalen sind vielversprechend: thermoakustische Wandler und Ferroelektret-Wandler. Basierend auf diesen beiden Technologien wurden Array-Sender gebaut und in diesem Beitrag miteinander verglichen.
Thermoakustische Wandler basieren auf Dünnschichttechnologie und bieten eine resonanzfreie Erzeugung von Ultraschall. Sie bestehen aus einer dünnen elektrisch leitenden Schicht und werden mit kurzen elektrischen Pulsen angeregt. Die Erhöhung der thermischen Energie führt zur Erzeugung von akustischen Wellen in der umgebenden Luft.
Bei Ferroelektret-Wandlern handelt es sich um polarisierte zelluläre Kunststoffe, die für den Bau eines Array-Senders besonders gut geeignet sind. Einige Ferroelektrete weisen eine hervorragende an Luft angepasste akustische Impedanz auf, so dass auf den Einsatz von Anpassschichten verzichtet werden kann. Ein sehr niedriges mechanisches Übersprechen zwischen einzelnen Elementen ermöglicht eine unabhängige Anregung einzelner Elemente, was bei Piezokompositen deutlich schwieriger wäre.
Mit der Phased-Array-Technik können elektronische Fokussierung oder Schwenkung des Einschallwinkels für eine luftgekoppelte Prüfung genutzt werden. Die Schallfelder von diesen beiden Technologien wurden berechnet, gemessen und miteinander verglichen. Die Vorteile und Nachteile der beiden Technologien werden dargestellt.
Phased-Array-Prüfköpfe für luftgekoppelte Ultraschallprüfung auf Basis von zellulären Kunststoffen
(2023)
Luftgekoppelte Ultraschallprüfung setzt sich immer häufiger gegen die konventionelle Ultraschallprüfung von Leichtbaukomponenten durch, und zwar in vielen Industriezweigen von der Holzindustrie bis zur Luftfahrt. Während die Phased-Array-Technik mittlerweile zu dem industriellen Standard im Bereich der Prüfung mit Ankopplung gehört, wird luftgekoppelte Ultraschallprüfung meist mit zwei Wandlern in Durchschallung durchgeführt. Deswegen werden Vorteile der Phased-Array-Technik wie beispielsweise elektronische Fokussierung oder Schwenkung des Einschallwinkels für luftgekoppelte Prüfung selten genutzt.
In diesem Beitrag werden die laufenden Arbeiten an der Entwicklung eines neuen Phased-Array-Geräts vorgestellt, mit dem Schwerpunkt an der Charakterisierung der Prüfköpfe und ihrer Schallfelder. Das Gerät besteht aus einem linearen Phased-Array-Prüfkopf, einer Sende- und einer Empfangseinheit. Die Hauptinnovation unserer Arbeit ist die Anwendung von zellulären Kunststoffen für den Bau eines Arrays, wobei der Sender mit Hochspannung von ca. 1500 V angeregt wird. Geladene zelluläre Polymere werden auch Ferroelektrete oder Piezoelektrete genannt. Sie weisen ein sehr niedriges Elastizitätsmodul und dadurch eine niedrige akustische Impedanz auf, so dass auf den Einbau von Anpassschichten verzichtet werden kann.
Eine sehr niedrige mechanische Kreuzkopplung bei Ferroelektreten ermöglicht eine unabhängige Anregung einzelner Elemente, was bei Piezokompositen deutlich schwieriger wäre. Die Entwicklung der Array-Prüfköpfe wurde durch Berechnungen des Schallfeldes unterstützt, die auf Punktquellensynthese basieren. Die beabsichtigte Anwendung von Phased-Array-Prüfköpfen und des Prüfsystems sind die Durchschallung mit Fokussierung, elektronischer Scan und die Schwenkung des Einschallwinkels zur Anregung von geführten Wellen, angewandt an carbonfaserverstärkten Kunststoffen und ähnlichen Materialien. Die Anwendung von geführten Wellen bietet die Perspektive, Bauteile mit einseitiger Zugänglichkeit zu prüfen.
Bei der Prüfung von Werkstücken mit empfindlichen Oberflächen oder auch hydrophilen Werkstoffen sind traditionelle ultraschallbasierte zerstörungsfreie Prüfmethoden wie die Kontakttechnik oder die Tauchtechnik in vielen Anwendungsfällen aufgrund der Flüssigkeitsankopplung nicht anwendbar.
Die luft-gekoppelte Ultraschallprüfung umgeht diese Problematik und eröffnet neue Prüfszenarien. Derzeit werden zwei Varianten der Schallerzeugung als vielversprechend angesehen: ferroelektrische Folien und thermoakustische Dünnschichtwandler. Thermoakustische Wandler ermöglichen die resonanzfreie Erzeugung von Ultraschall und somit kurze zeitliche Impulse sowie eine sehr breitbandige Anregung. Durch die Verwendung von gekrümmten Substraten ist sowohl eine Herstellung von planaren als auch fokussierten Wandlern möglich.
Dieser Beitrag präsentiert die letzten Forschungsergebnisse im Bezug auf thermoakustischen Wandlern, welche derzeit in einen thermoakustischen Gruppenstrahler münden. Gruppenstrahler erlauben die simultane Änderung des Einschallwinkels, sowie die Verschiebung des Fokuspunktes während der Verwendung.
Durch die Verbindung beider Schlüsseltechnologien, der thermoakustischen Anregung und des Gruppenstrahlerprinzips, wird das Spektrum der klassischen ZfP-Anwendungen, sowie moderner Ansätze wie der Anregung von geführten Wellen oder der Strukturüberwachung erheblich erweitert und bereichert.
Dabei soll innerhalb dieses Beitrages auf die Modellierung des Schallfeldes, die elementweise Charakterisierung und verschiedene Anwendungsszenarien eingegangen werden.
Critical defects, also known as device killers, in wide bandgap semiconductors significantly affect the performance of power electronic devices. We used the methods imaging ellipsometry (IE) and white light interference microscopy (WLIM) in a hybrid optical metrology study for fast and non-destructive detection, classification, and characterisation of defects in 4H–SiC homoepitaxial layers on 4H–SiC substrates. Ellipsometry measurement results are confirmed by WLIM. They can be successfully applied for wafer characterisation already during production of SiC epilayers and for subsequent industrial quality control.
Bewertung der Innenhydrophobierung als neuartige AKR-Vermeidungsstrategie bei Betonfahrbahndecken
(2023)
Zur Vermeidung von AKR-Schäden an Betonfahrbahndecken im deutschen Autobahnnetz wurden mit dem ARS 04/2013 verbindliche Eignungsprüfungen zum Ausschluss alkaliempfindlicher Gesteinskörnungen bei Neubau- und Erhaltungsmaßnahmen eingeführt. Das hatte eine signifikante Reduzierung geeigneter Gesteinskörnungen zur Folge. Deshalb wird geprüft, ob durch die Zugabe eines Hydrophobierungsmittels während der Betonherstellung grenzwertig alkaliempfindliche Gesteinskörnungen nutzbar gemacht werden können. In diesem Beitrag wird der Einfluss der Dosierung eines Compounds mit Hydrophobierungsmittel (HM) auf die Frisch- und Festbetoneigenschaften eines Waschbetons mit einer reaktiven Grauwacke dargestellt. Es zeigt sich, dass aufgrund des Antagonismus die zunehmende Dosierung des HM-Compounds eine signifikante Erhöhung der Zugabe des Luftporenbildners auf Wurzelharzbasis erfordert. Der AKR-Schädigungsprozess wird ab einer Dosierung des HM-Compounds von 0,75 M.-%, bezogen auf den Zementgehalt, hinreichend vermindert. Die mechanischen Eigenschaften des hydrophobierten Waschbetons verschlechtern sich im betrachteten Dosierungsbereich des HMCompounds nur geringfügig. Auch der Frost-Tausalz-Widerstand vermindert sich, ohne den normativen Grenzwert für die Abwitterung zu überschreiten.