Filtern
Dokumenttyp
Schlagworte
- Drop test (4)
- Behälter (3)
- Fallprüfung (3)
- Gefahrstoffe (3)
- Hopkinsonstab (3)
- Dangerous goods container (2)
- Energy harvesting (2)
- Funksensorik (2)
- Hopkinson bar (2)
- Multichannel measuring (2)
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.
Dehnungsmessstreifen (DMS) gehören zu den Standardsensoren beim Messen mechanischer Größen.
Sie finden Ihre Anwendung auf unterschiedlichen Gebieten, als sensorische Komponente in
Messaufnehmern (z.B. Wägezelle, Kraftaufnehmer) oder für Dehnungsmessungen im Bereich der
Strukturüberwachung unter anderem an Brücken oder Bauwerken. Sie werden in verschiedenen Größen
geliefert und mit entsprechenden Klebstoffen auf der Objektoberfläche des Messobjekts an der jeweiligen
Messstelle angebracht und an das Messsystem angeschlossen. Dieser Aufbau wird bei den
verschiedenen Anwendungen unterschiedlichen Temperaturen und Umwelteinflüssen ausgesetzt. Dabei
wird das System DMS/Klebstoff in seinen Eigenschaften verändert und das Ergebnis der
Dehnungsmessung beeinflusst. Beispielsweise kann es zu einer Verfälschung der Messergebnisse
kommen, wenn der Klebstoff die Dehnung des Messobjekts nicht vollständig auf den DMS überträgt, oder
es kann eine Nullpunktverschiebung der Dehnungsmessung auftreten.
An der Bundesanstalt für Materialforschung und -prüfung werden Fallversuche von Lager- und
Transportbehältern durchgeführt. Für diese werden Dehnungsmessstreifen auf den Behälter angebracht
um die Dehnung bzw. Verformung zu messen. Bei den Versuchen werden verschiedene Parameter
berücksichtigt: Neben unterschiedlichen Fallhöhen (u.a. 9 m und 1 m) wird auch der Temperatureinfluss
auf den Fallversuch z.B. bei -40 °C oder +100 °C untersucht. Zur Applizierung von DMS auf
Objektoberflächen gibt es für verschiedene Anwendungsbedingungen (DMS-Typ, Objektoberflächenbeschaffenheit,
Einsatztemperatur) von den DMS-Herstellern jeweils empfohlene Klebstoffe.
Insbesondere für Anwendungsfälle mit hochdynamischer Belastung (Fallversuche, Crash-Tests) und
großem Temperaturbereich ist es erforderlich, dass die Dehnungsmessstreifen zuverlässige Werte
ausgeben. Dies ist nur gegeben, wenn der Klebstoff eine gute Verbindung zwischen Messobjekt und
Dehnungsmessstreifen herstellt.
Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were presented in a previous study. This paper follows up with results from laboratory and full-scale testing of an further enhanced single cable system for the application in drop tests.----------------------------------------------------------------------------------------------------------------------------------------------------------------
Vielkanalmesssysteme werden zur Messung von Dehnungen und Beschleunigungen bei Fallversuchen von Gefahrstoffbehältern eingesetzt. Konventionelle Systeme erfordern die Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. In einer vorangegangenen Studie wurden vielversprechende Ergebnisse durch Verwendung eines 1-Kabelmesssystems mit Datenbus und dezentraler Datenspeicherung erzielt. Dieser Artikel beinhaltet weiterführende Ergebnisse aus Labor- und Realversuchen mit einem weiterentwickelten System zur Anwendung bei Fallversuchen.
One of the main unsolved issues of under-ground storages for, e.g., CO2, H2, and natural gas is the comprehensive surveillance of these areas with reasonable effort and costs. Conventional sensors (e.g., soil air probes or borehole probes), however, can only be used for punctual or locally limited measurements; further their application can cause structural influences (invasive application).
In this paper, we describe in detail the setup of a CO2 injection soil test field. This test field will be used to enhance and validate an innovative ap-proach for distributed subsurface monitoring of gas storage areas. To the author’s knowledge, this is the first time that, for this purpose, a test field is built in an application relevant scale.
Long-term completely embedded sensor systems offer innovative possibilities for structural health monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors. This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external reader device. To evaluate characteristics and conditions of this concept, a systematical investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were obtained in laboratory investigations and full-scale drop tests.
The measurement characteristics of every conventional accelerometer are temperature dependent - often to an extent which is highly relevant for the addressed application. For instance, at BAM Container drop tests are performed to investigate and evaluate the structural integrity of Containers for transport and storage of dangerous goods. Often, the test program includes drop tests at specific temperatures, also as part of approval procedures. The applied sensors are exposed to these test conditions and get influenced by them. Acceleration sensors show a considerable temperature influence on their fünction and characteristics. Particularly the damping mechanism of the seismic mass is a critical part. In regard to such applications, capable equipment and methods are required to consider and investigate this aspect in an adequate way. A fortiori as Manufacturer’s infonnation often is deficient. This study presents the setup and results of a method for testing and calibration of acceleration sensors under high dynamic irnpact. It combines a Hopkinson Bar with a temperature chamber.
Strain and acceleration measurement during high dynamic drop tests, e.g., of containments for dangerous goods is performed using high speed multichannel measuring systems. So far established and operated systems need a cable connection of every strain gauge and acceleration sensor with the measuring device, often counting up to a number of more than 100 cables, corresponding to the number of applied sensors. The result is a massive cable harness consisting of all single cables, which is difficult to handle and causes a number of practical problems. An innovative approach is proposed by using a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition. Promising results were presented in a previous study. This paper follows up with additional results from full-scale testing of a further enhanced single cable system for the application in drop tests.