Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (79)
- Zeitschriftenartikel (51)
- Posterpräsentation (46)
- Vortrag (33)
- Beitrag zu einem Sammelband (8)
- Forschungsbericht (4)
- Sonstiges (2)
- Dissertation (1)
Sprache
- Englisch (151)
- Deutsch (70)
- Mehrsprachig (2)
- Polnisch (1)
Schlagworte
- Structural health monitoring (16)
- RFID sensors (14)
- Gas storage areas (12)
- Membrane-based gas sensing (12)
- Subsurface monitoring (12)
- Monitoring (11)
- Mobile Robot Olfaction (10)
- Nano aerial robot (10)
- Smart structures (10)
- Drop test (9)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (67)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (67)
- 1 Analytische Chemie; Referenzmaterialien (9)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (8)
- 1.9 Chemische und optische Sensorik (7)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 3 Gefahrgutumschließungen; Energiespeicher (2)
- 6 Materialchemie (2)
- 6.7 Materialsynthese und Design (2)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (33)
With the reduction of large oil spills because of stricter regulations and safety measures, the question of how to manage smaller oil spills arises. Few on-site analytical tools are available for first responders or other law enforcement personnel to rapidly test for crude oil in the early management of localized polluted areas. The approach reported here relies on well-described computer-assisted multivariate data analysis of the intrinsic fluorescence fingerprints of crude oils to build a multivariate model for the rapid classification of crude oils and the prediction of their properties. Thanks to a dedicated robust portable reader, the method allowed classification and accurate prediction of various properties of crude oil samples like density (according to API, the American Petroleum Institute and viscosity as well as composition parameters such as volume fractions of paraffins or aromatics. In this way, autonomous operation in on-site or in-the-field applications becomes possible based on the direct (undiluted and untreated) measurement of samples and a rapid, tablet-operated readout system to yield a robust and simple analytical test with superior performance. Testing in real-life scenarios allowed the successful classification and prediction of a number of oil spill samples as well as weathered samples that closely resemble samples collected by first responders.
Structural Health Monitoring (SHM) has become very important in today's rapidly developing time. High buildings, large bridges and complex technical structures need to be monitored continuously and this over long periods.
Visual monitoring cannot evaluate the internal condition of building structures. Thus, material embedded sensors are needed. Cable connection of these sensors pose the disadvantage of weak spots and water intrusion. For concrete embedded sensors the use of batteries is not convenient, because of limited lifetime, difficult charging, and generation of electrical waste.. Hence, monitoring should be implemented preferentially with firmly embedded passive RFID sensor modules. However, since the concrete structure forms an electromagnetically reflective and absorbing barrier, only limited energy can be transmitted to the module. This project requires a highly energy-saving system, which can record different sensor parameters at critical points.
Comprehensive monitoring of pipelines over their full length is technically difficult and expensive. Considering a cost-benefit ratio it is reasonable to implement monitoring solutions in pipeline segments, which bear a high risk potential, like residential areas, construction sites, slopes, street or river crossings. Still such segments can measure up to several hundred meters in length, demanding for monitoring solutions that extend along such distances and enable fast response. Point wise sensing and periodical surveillance have clear drawbacks, particularly regarding early damage detection. Fibre optic sensors enable distributed sensing of temperature and strain, but they offer very limited possibilities for measuring gas concentrations. Linear membrane-based gas sensors enable the monitoring of gas concentrations alongside a pipeline. Such line-sensors are implemented in form of flexible tubes and can be arranged inside or outside the pipeline (also underwater or within the subsurface), corresponding to the technical requirements. The measuring method combines the gas specific diffusion rates through a membrane with Dalton’s law of partial pressures and enables the calculation of gas concentrations or the detection of a change of the gas composition. The objective is to detect gas leakages fast and with high reliability. Furthermore, the calibrated system enables to estimate the spatial extent of a leakage. So far the gas concentration measurement is tested for oxygen, carbon dioxide, methane; further gases should follow, e.g. hydrogen, carbon monoxide or mixtures like natural gas. The paper introduces in the different operating modes of line-sensors. A near real-time approach will be demonstrated to quantify the impact of a gas leak on the near environment. This approach is based on a critical length describing the expansion of the leaking gas.
Wastewater contains harmful chemicals and heavy metals that are known to cause various environmental and health problems. Therefore, the water quality control using sensitive, simple, fast, accurate, and portable tools is of great importance. This study aimed to evaluate the pollution parameters of wastewaters collected at different treatment stages from a wastewater treatment plant (WWTP) that treats domestic and industrial wastewaters by using an electronic nose (E-nose) and a voltammetric electronic tongue (E-tongue) combined with chemometric techniques. Water and wastewater pollution parameters determination were performed using inductively coupled plasma optical emission spectrometry for the determination of cations, and anions by using ion chromatography. Chemometric techniques, such as Principal Component Analysis (PCA), Discriminant Function Analysis (DFA), Support Vector Machines (SVMs), and Hierarchical Cluster Analysis (HCA), were used to process the E-nose and E-tongue datasets to describe the similarities between the samples. In addition, Partial Least Squares Regression (PLSR) model was constructed using electronic sensing data to simultaneously predict the concentration values of physicochemical parameters. The obtained correlation coefficient, for training and testing sets, is higher than 0.91 for the prediction of the concentration of all physicochemical parameters, except for iron (Fe) which remains 0.84. These results suggest that simple, portable, and inexpensive tools such as electronic nose and tongue are suitable for wastewater analysis.
Sensor based person tracking is a challenging
topic. The main objective is positioning in areas without
GPS connection, i.e. indoors. A research project is carried
out at BAM, Federal Institute for Materials Research and
Testing, to develop and to validate a multi-sensor system for
3D localization. It combines body motion sensing and a
guard system for the tracking and recording of the status of
persons. The so named BodyGuard system was designed for
sensor-based monitoring and radio-based transmission of
the movement of a person. Algorithms were developed to
transform the sensor data into a spatial coordinate. This
paper describes how the BodyGuard system operates, which
main components were used in the system, how the
individual sensor data are converted into 3D motion data,
with which algorithms the individual sensors are processed,
how individual errors are compensated and how the sensor
data are merged into a 3D Model. Final objective of the
BodyGuard system is to determine the exact location of a
person in a building, e.g. during fire-fighting operations.
Real-time wind estimation on a micro unmanned aerial vehicle using its inertial measurement unit
(2015)
This paper presents an approach for a quadrocoper-based micro unmanned aerial vehicle (UAV) that estimates the wind vector (speed and direction) in real-time based on measurement data of its on-board sensors only. This method does not need any additional airspeed sensor or dedicated anemometer, and thus the micro UAV's valuable payload remains free for other sensors. Wind tunnel and field tests were used to evaluate the performance of the approach. In order to quantify its accuracy, experiments are presented where data was collected with an anemometer placed in an open field with the micro UAV in flight following a predefined trajectory around the anemometer and hovering at a defined position close to it.
This presentation gives an introduction to the gas-sensitive aerial robots developed at BAM, including various application examples in the field of mobile robot olfaction: gas source localization and gas distribution mapping.
The exploration of condensed phase mechanisms such as charring and intumescence has been pushed forward in the last decades, since it is believed that focusing on these concepts will bring materials closer to an efficient and ecologically friendly fire retardancy. They promise to concentrate efficient fire retardancy at the key position between pyrolysis zone and gas phase. Examples of residue/char forming and intumescent materials are used to illustrate the influence of mass and heat barrier effects on the fire behavior of materials and general results are presented. A comprehensive understanding of the mechanisms and structure-property relationships in fire retardancy is presented.
This paper is a further research on the topic of the complete embedding of radio frequency identification (RFID) sensors in concrete. The focus is on the antenna of the transponder. Earlier investigations of different RFID technologies, embedded in concrete, showed a difference in energy transmission. The transmission through concrete at ultra high frequency (UHF), in spite of the large signal range, does not match the targeted application specific task. Therefore, the antenna characteristics have been examined more closely. The antenna is an important component for the application of RFID. Through the antenna, energy and data transfer takes place, so it is important to design an optimal antenna to accomplish a maximum embedding depths in concrete. To identify the optimal antenna geometry, different UHF antenna types were selected and investigated. An experimental comparison was performed to gain more information about the damping behavior and antenna characteristics in concrete.
Long-term completely embedded sensor systems offer innovative possibilities for structural health monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors. This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external reader device. To evaluate characteristics and conditions of this concept, a systematical investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
One of the more difficult tasks for structural health monitoring is the continuous evaluation of the stability and load capacity of the building materials. This knowledge can be won, e.g., by taking material samples at the examining place with the drawback of partly destroying the structure. To avoid this, modern sensor and communication technologies offer promising methods for non-destructive testing. To address the tasks for monitoring of concrete structures, in the presented study, different sensors were combined with RFID transponders and embedded in concrete components.
Structural Health Monitoring (SHM) is an important topic for Industry 4.0. More and more systems are embedded in different materials and are connected to each other. To embed sensors for a long time in concrete, an exact preparation is required. In this paper, we identify Radio-Frequency Identification (RFID) as promising technology for monitoring of concrete structures. This paper present the concept for long term monitoring, defines the requirements and shows first development steps, for example, the system design, the possibilities of sensor connection, and an encapsulation for embedding in concrete.
Long-term completely embedded sensor systems offer innovative possibilities for structural health Monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors.
This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external Reader device. To evaluate characteristics and conditions of this concept, a systematical Investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH 13 solution for 14 days
- 3D-Printer-Polymer was completely resolved
- PVC has no noticeable decrease in weight
- (VitaPro) glass filter for the sensor protector, has weight loss 2.7 %
- The epoxy resin has increased by 1.8 % due to moisture expansion
Different concrete samples were prepared for the validation of the systems.
RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH 13 solution for 14 days
- 3D-Printer-Polymer was completely resolved
- PVC has no noticeable decrease in weight
- (VitaPro) glass filter for the sensor protector, has weight loss 2.7 %
- The epoxy resin has increased by 1.8 % due to moisture expansion
Different concrete samples were prepared for the validation of the systems.
RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
Structural Health Monitoring (SHM) is an important part of buildings surveillance and maintenance to detect material failure as early as possible and to contribute in protection of structures and their users.
The implementation of Radio Frequency Identification (RFID) sensor systems without cable connection and battery into building components offers innovative possibilities to enable long-term in-situ SHM of addressed structures, bridges. The objectives of the presented study are complete embedding of RFID sensors systems in concrete, full passive communication with the systems, at best for the whole life span of structures. One challenge for this task is the highly alkaline environment in concrete, which requires non-degrading and robust encapsulation. Further Requirements are passive communication and energy supply, appropriate antenna design, placement and fixation in concrete, and the selection and implementation of sensors and connections. The concept is to develop and optimize a simple and robust system, which meets the requirements, as well as comprehensive validation in concrete specimen and real world applications. Two different systems were developed (HF and UHF RFID, respectively).
First tasks were the implementation of analog sensors using the superposition principle for the signal adaption. Investigation of suitable materials for robust encapsulation and sensor protection against basic environments.
Four materials were investigated in pH13 solution for 14 days - 3D-Printer-Polymer was completely resolved - PVC has no noticeable decrease in weight - (VitaPro) glass filter for the sensor protector, has weight loss 2.7% - The epoxy resin has increased by 1.8% due to moisture expansion Different concrete samples were prepared for the validation of the systems. RFID sensors were embedded in different integration depths. Investigate the energy- and data transfer through concrete, also with varying moisture content. Additionally, signal strength data was used to optimize and validate the antenna characteristics in concrete. Next steps are to guarantee a sufficient energy supply for UHF RFID systems embedded in different concrete mixtures and further embedding the HF and UHF RFID systems in real bridges and buildings to validate the long term monitoring.
The project SIGRID investigates and assesses possibilities to enhance the safety and security of
dangerous goods transports through the use of the latest RFID-technology. This technology can be used to
greatly enhance the transparency of the supply chain and aid logistics companies in complying with regulations.
In the context of SIGRID, customized RFID-Sensor-Tags have been developed that monitor dangerous
goods during transport and help to prevent hazards by allowing timely countermeasures. In the case of a dangerous
goods accident, the available information about the type, amount and condition of the dangerous goods
can be used to accurately inform the relief forces. Unavailable or inaccurate information represents a significant
problem for the relief forces. This often leads to a delay in the rescue operation, because relief forces
must be aware of the substances involved to protect themselves effectively against them. SIGRID aims to
close this information gap. To verify the practicability of the underlying concepts, a demonstrator will be
build and tests of realistic scenarios will be conducted.
This paper describes the development of a semi-automatic gas measurement device presenting potentially a broad range of applications, noteworthy in the agricultural sector. Non-reversible fluorescent molecular sensors were designed and syn-thesized. Upon, integration into a hydrogel matrix with an optimal ratio of co-solvents, the sensors reacting selectively to ammonia were illuminated by excitation light to produce a concentration-correlated fluorescence emission. An automated mechanical-elec-trical device initiates a given gas mixture and thus simulates con-centrations similar to a threshold value. The aim of this project is to develop a sensor or a low-cost method which can monitor low concentrations of harmful gases and aid in their elimination or regulation in livestock housing, barns or stables.
In the present paper the development of a semi-automated device for long-term monitoring of gaseous ammonia is described. A sensor material was produced that changes its optical properties in the pres-ence of low concentrations of ammonia in air. The implementation into an electronic device enables precise, simple, economic and fast monitoring of low concentrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.
The present paper describes the development of a sensor material that changes its fluorescence in the presence of gaseous ammonia in a relevant concentration range. The implementation into a semi-automatic gas measurement device enables low-cost, precise, simple and fast monitoring of low con-centrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.
Sensor network deployment
(2018)
One of the main unsolved issues of under-ground storages for, e.g., CO2, H2, and natural gas is the comprehensive surveillance of these areas with reasonable effort and costs. Conventional sensors (e.g., soil air probes or borehole probes), however, can only be used for punctual or locally limited measurements; further their application can cause structural influences (invasive application).
In this paper, we describe in detail the setup of a CO2 injection soil test field. This test field will be used to enhance and validate an innovative ap-proach for distributed subsurface monitoring of gas storage areas. To the author’s knowledge, this is the first time that, for this purpose, a test field is built in an application relevant scale.
A 400 m² soil test field with gas injection system was built up for the purpose of large-scale validation, optimization, and characterization of a novel comprehensive monitoring method for underground gas storage areas. The method combines gas sensing technology with linear form factor for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct time-series of gas distribution maps based on samples of orthogonally-aligned linear gas sensors. Several injection experiments with carbon dioxide (CO2) at different days with varying boundary conditions indicates the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues.
Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were presented in a previous study. This paper follows up with results from laboratory and full-scale testing of an further enhanced single cable system for the application in drop tests.----------------------------------------------------------------------------------------------------------------------------------------------------------------
Vielkanalmesssysteme werden zur Messung von Dehnungen und Beschleunigungen bei Fallversuchen von Gefahrstoffbehältern eingesetzt. Konventionelle Systeme erfordern die Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. In einer vorangegangenen Studie wurden vielversprechende Ergebnisse durch Verwendung eines 1-Kabelmesssystems mit Datenbus und dezentraler Datenspeicherung erzielt. Dieser Artikel beinhaltet weiterführende Ergebnisse aus Labor- und Realversuchen mit einem weiterentwickelten System zur Anwendung bei Fallversuchen.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
In civil engineering, many structures are made of reinforced concrete. Most Degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture.
Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days.
Moreover, long-term moisture monitoring is performed for more than 1000 days. The Experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.
Barrier formation and increasing the melt viscosity are addressed as the two main general fire retardancy mechanisms of polymer nanocomposites. They result in specific impacts on fire properties that consequentially cause varying flame retardancy efficiency in different fire tests. The barrier formation retards mainly flame spread (peak of heat release rate) in developing fires, but does not reduce fire load (total heat evolved), ignitability or flammability (limiting oxygen index, UL 94). Furthermore, this flame retardancy effect increases with increasing irradiation and vanishes with decreasing irradiation. The increased melt viscosity prevents dripping, which is beneficial or disadvantageous depending on the fire test used. In some test, it become the dominant influence, transforming self-extinguishing samples into flammable materials or causing wicking. Advantages and the limits are sketched comprehensively for exploiting the main general fire retardancy mechanisms of polymer nanocomposites. It is concluded that barrier formation and changing the melt viscosity in nanocomposites are not sufficient for most applications, but must be accompanied by additional mechanisms in special systems or in combination with other flame retardants.
The cone calorimeter has become one of the most important and widely used instruments for the research and development of fire retarded polymeric materials. The paper addresses three important ways in which the principal setup influences the results factors which sometimes do not receive due consideration when drawing conclusions. The paper discusses in detail the impact on cone calorimeter results of the choice of external heat flux, the influence on the peak of heat release rate of sample thickness and thermal feedback from the back of the sample, and the influence on irradiance of the horizontal and vertical distances from the cone heater.
Ständig überwacht
(2012)
Dehnungsmessstreifen (DMS) gehören zu den Standardsensoren beim Messen mechanischer Größen.
Sie finden Ihre Anwendung auf unterschiedlichen Gebieten, als sensorische Komponente in
Messaufnehmern (z.B. Wägezelle, Kraftaufnehmer) oder für Dehnungsmessungen im Bereich der
Strukturüberwachung unter anderem an Brücken oder Bauwerken. Sie werden in verschiedenen Größen
geliefert und mit entsprechenden Klebstoffen auf der Objektoberfläche des Messobjekts an der jeweiligen
Messstelle angebracht und an das Messsystem angeschlossen. Dieser Aufbau wird bei den
verschiedenen Anwendungen unterschiedlichen Temperaturen und Umwelteinflüssen ausgesetzt. Dabei
wird das System DMS/Klebstoff in seinen Eigenschaften verändert und das Ergebnis der
Dehnungsmessung beeinflusst. Beispielsweise kann es zu einer Verfälschung der Messergebnisse
kommen, wenn der Klebstoff die Dehnung des Messobjekts nicht vollständig auf den DMS überträgt, oder
es kann eine Nullpunktverschiebung der Dehnungsmessung auftreten.
An der Bundesanstalt für Materialforschung und -prüfung werden Fallversuche von Lager- und
Transportbehältern durchgeführt. Für diese werden Dehnungsmessstreifen auf den Behälter angebracht
um die Dehnung bzw. Verformung zu messen. Bei den Versuchen werden verschiedene Parameter
berücksichtigt: Neben unterschiedlichen Fallhöhen (u.a. 9 m und 1 m) wird auch der Temperatureinfluss
auf den Fallversuch z.B. bei -40 °C oder +100 °C untersucht. Zur Applizierung von DMS auf
Objektoberflächen gibt es für verschiedene Anwendungsbedingungen (DMS-Typ, Objektoberflächenbeschaffenheit,
Einsatztemperatur) von den DMS-Herstellern jeweils empfohlene Klebstoffe.
Insbesondere für Anwendungsfälle mit hochdynamischer Belastung (Fallversuche, Crash-Tests) und
großem Temperaturbereich ist es erforderlich, dass die Dehnungsmessstreifen zuverlässige Werte
ausgeben. Dies ist nur gegeben, wenn der Klebstoff eine gute Verbindung zwischen Messobjekt und
Dehnungsmessstreifen herstellt.
Motivation:
- Beschleunigungsaufnehmer (BA) sind in ihrer Funktion und in ihren Messeigenschaften stark temperaturabhängig
- kritisch ist z. B. der Dämpfungsmechanismus der seismischen Masse piezoelektrischer BA
- Anwendung: z. B. Fallversuche mit spezifischer Temperaturvorgabe (- 40 °C, + 100 °C)
- Entwicklung eines geeigneten Prüfverfahrens zur temperaturabhängigen Untersuchung von BA
Temperature characteristics of a piezoresistive accelerometer for high impact shock application
(2018)
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
Temperature characteristics of a piezoresistive accelerometer for high impact shock application
(2018)
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
BAM Federal Institute for Materials Research and Testing, in cooperation with the company MeGaSen UG carries out a research project to enhance and validate an innovative approach for distributed subsurface monitoring of gas storage areas. The concept combines different measurement technologies to one multifunctional sensor: membrane-based gas measurement technology for in-situ monitoring of gases in soil and fiber optical sensing of temperature and strain (as a measure for structural change). Key aspect of the research project is the first-time validation of the system in an application relevant dimension. For this purpose a 20 x 20 m2 test field is build. A comprehensive validation of the system is carried out by systematic variation of different parameters like position-dependent gasinjection, temperature and mechanical impact.
Thermogravimetry (TG), thermogravimetry coupled with mass spectroscopy (TG-MS) and thermogravimetry coupled with Fourier transform infrared spectroscopy (TG-FTIR) were used to characterise the thermo-oxidative behaviour of two intumescent coating materials. The temperature dependence, the corresponding volatile products and the amount of residue of the different processes were determined. Using both TG-MS and TG-FTIR results in an unambiguous interpretation of the volatile products. Characteristics such as the influence of endothermic reactions, the release of non-flammable gases, the dehydrogenation enhancing the char formation and the stability of the cellular char were discussed in detail. It was demonstrated, that TG, TG-MS and TG-FTIR are powerful methods to investigate mechanisms in intumescent coatings and that they are suitable methods in respect to quality assurance and unambiguous identification of such materials.
A monitoring method is introduced that creates twodimensional (2D) maps of the soil gas distribution. The method combines linear gas sensing technology for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct spatial and temporal resolved gas distribution maps. A weighted iterative algebraic reconstruction method based on Maximum Likelihood with Expectation Maximization (MLEM) in combination with a source-by-source reconstruction approach is introduced that works with a sparse setup of orthogonally-aligned linear gas sensors. The reconstruction method successfully reduces artifact production, especially when multiple gas sources are present, allowing the discrimination between true and non-existing so-called ghost source locations. Experimental validation by controlled field experiments indicates the high potential of the proposed method for rapid gas leak localization and quantification with respect to Pipeline or underground gas storage issues.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
A multi-sensor system for 3D localization was developed and named BodyGuard. It combines body movement sensing and a guard system for the tracking and recording of the status of persons. BodyGuard was designed to monitor and transmit the movement of a person radio-based and to transform that data into a spatial coordinate. This paper describes how the BodyGuard system works, what components the system consists of, how the individual sensor data is converted into 3D motion data, with which algorithms the individual sensors are processed, how individual errors are compensated and how the sensor data are fused into a 3D Model.
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.