Damage to buildings occurs if a construction component fails. The result is a partial or total collapse which can be dangerous for people for example if it's a bridge or a large hall. The collapse of the terminal building at the Airport Charles de Gaulle in Paris and the damage at the historic City Archives of Cologne are typical examples of such accidents. Another problem is the contradiction of the increasing volume of traffic (particularly heavy traffic) and the great age of bridges. The probability increases that the load-bearing capacity of a bridge decreases. For example the collapses of the Mississippi Bridge and of the Inntal Motorway Bridge can be seen as results. Therefore it is necessary to control endangered structures during their life span.
In order to prevent these kinds of accidents, the Federal Institute for Materials Research and Testing developed a radio-based, self-configuring measuring system in cooperation with the ScatterWeb Company, Berlin (Germany). This measuring system consists of identically designed sensor modules which are self-sustaining, wireless, act as transmitters and receivers and are equipped with a special sensor technology for long-term monitoring of buildings or engineering facilities. The sensor unit uses strain gauges for stress analysis and contains interfaces for additional sensors. The system in particular applies to buildings and structures for transport and traffic and large-scale industrial facilities, where a subsequent wiring installation is difficult or impossible.
Increasing traffic volume on the one hand and ageing infrastructure on the other hand have created many new challenges for maintenance and structural health monitoring of roads and bridges. In the past, many bridges and road structures have been neglected, often resulting in traffic congestion, road closure, and increased repair costs.
This research is concerned with the development of a system to improve the challenge of maintenance and early detection of damage, particularly moisture penetration and corrosion of steel reinforced concrete components. The objective is to develop a method that will also work after 30 years and longer. Many new IoT solutions are equipped with internal energy storage elements (accumulators or batteries) which are inappropriate here, since most relevant signs of concrete degradation occur after decades, where the functioning of such elements are more than questionable. The presented technology approach uses radio-frequency identification (RFID) and enables connectivity to sensors. It offers the advantage of an passive, completely independent energy supply without any energy storage components.
Since the system should be permanently embedded in concrete, it is crucial to develop a long-term stable device which is adapted to the environmental influences of the structure, e.g., long-term resistance in very alkaline environment of pH 13. In numerous experiments, the robustness of the system was tested and evaluated. Various tests with encapsulations to protect the electronics were performed, and for long-term validation different concrete specimens were instrumented with RFID-sensor-systems. Their operating time is now around two years and investigations for signs of fatigue and damage to the encapsulation and the electronics are ongoing.
In this study a method for early damage detection is investigated based on the directed excitation and measuring of Lamb waves (guided waves). The objective is to make a statement about the practicability of a Lamb wave generator (LWG) and about the application relevant parameters (specimen materials and dimensions, wave characteristics, excitation, transmission und reflection). Guided waves enable an effective differentiation of structural and defective indications as well as a classification of different defect types. For the investigations, a LWG was developed which combines the advantages of the single excitation of a piezoelectric actuator and the possibility of a group excitation. Algorithms were developed to identify and analyze damage patterns (cracks, wholes, weakening).