Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (63) (entfernen)
Schlagworte
- Gas storage areas (9)
- Membrane-based gas sensing (9)
- Subsurface monitoring (9)
- Autonomous micro UAV (5)
- Gas source localization (5)
- Distributed linear sensor (4)
- Distributed sensor (4)
- Electronic nose (4)
- Embedded sensors (4)
- Nanocomposites (4)
- Structural health monitoring (4)
- Chemical and wind sensing (3)
- Computed tomography (3)
- Cone Calorimeter (3)
- Drop test (3)
- Fire retardancy (3)
- Linear sensor (3)
- Nano aerial robot (3)
- Particle filter (3)
- Artificial potential field (2)
- Behälter (2)
- Chemometric techniques (2)
- Cone calorimetry (2)
- Dangerous goods container (2)
- Fallprüfung (2)
- Fiber Bragg grating (2)
- Fibre optical sensing (2)
- Flame retardance (2)
- Flammability (2)
- Fluorescence (2)
- Gefahrstoffe (2)
- Hopkinson bar (2)
- Hopkinsonstab (2)
- Intumescent coatings (2)
- LOI (2)
- Localization (2)
- Magnetic field (2)
- Magnetostriction (2)
- Mobile robot olfaction (2)
- Monitoring (2)
- Monitoring of CO2 (2)
- Multichannel measuring system (2)
- Nanocomposite (2)
- Numerical analysis (2)
- Organoclay (2)
- Quadrocopter (2)
- RFID sensors (2)
- Sensor planning (2)
- Soil test field (2)
- Strain (2)
- Swarm (2)
- TDLAS (2)
- Trail detection (2)
- Trail following (2)
- Vielkanalmesssystem (2)
- Voltammetric electronic tongue (2)
- Wastewater (2)
- Wireless sensors (2)
- Actuators (1)
- Aerial robot (1)
- Aerial robot olfaction (1)
- Airspeed calibration (1)
- Anemometric sensor (1)
- Auto-validation (1)
- Biologically inspired robots (1)
- CCS (1)
- CO2 (1)
- Calibration (1)
- Carbon capture and storage (1)
- Carbon multiwall nanotube (MWNT) (1)
- Cationic polymerisation (1)
- Chemical sensing (1)
- Civil engineering (1)
- Clay (1)
- Collision-free navigation (1)
- Combustion (1)
- Concept (1)
- Cone Caorimeter (1)
- Cone calorimeter (1)
- Container (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- DDS (1)
- Dangerous goods (1)
- Data bus (1)
- Data mapping (1)
- Data-Mapping (1)
- Datenbus (1)
- Degradation (1)
- Discrimination of multiple gas sources (1)
- Early damage detection (1)
- Early-damage-detection (1)
- Elastoplastic material parameters (1)
- Embedded system (1)
- Embedded systems (1)
- Emission control (1)
- Emissionskontrolle (1)
- Energy harvesting (1)
- Environmental analysis (1)
- Epoxide (1)
- Fiber Bragg gratings (1)
- Fiber bragg grating (1)
- Fiber optic sensing (1)
- Fiber optical sensing (1)
- Fibre optical sensing (1)
- Field conditions (1)
- Finite element methods (1)
- Fire testing (1)
- Flame retardancy (1)
- Fluorescent sensor (1)
- Fluoreszenz (1)
- Gas dispersion simulation (1)
- Gas distribution mapping (1)
- Gas distribution mapping and gas source localization (1)
- Gas distribution modelling (1)
- Gas emission (1)
- Gas measurement (1)
- Gas sensing (1)
- Gas sensors (1)
- Gas tomography (1)
- Gas-sensitive micro-drone (1)
- Gasemission (1)
- Gasmessung (1)
- Guided wave (1)
- High Impact testing (1)
- High impact testing (1)
- Hochdynamische Prüfung (1)
- Indentation (1)
- Indoor air quality (1)
- Inertial measurement unit (1)
- Inertial measurement unit (IMU) (1)
- Inertial navigation system (1)
- Intumescence (1)
- Intumescent coating materials (1)
- Lamb wave (1)
- Lamb-waves (1)
- Large scale soil test field (1)
- Leak detection (1)
- Leakage (1)
- Long-term requirements (1)
- Magnetostrictive metal coating (1)
- Membrane-based linear gas sensor (1)
- Metal oxide semiconductor (1)
- Mg(OH)2 (1)
- Micro unmanned aerial vehicle (UAV) (1)
- Micro-drone (1)
- Mikrodrohne (1)
- Mobile Robot Olfaction (1)
- Mobile sensing system (1)
- Modeling and simulation (1)
- Moisture (1)
- Monitoring of CO 2 (1)
- Multichannel measuring (1)
- Multifunctional sensor (1)
- Multivariate analysis (1)
- Non-destructive evaluation (1)
- Oil (1)
- Oil spills (1)
- Outdoor odor emissions (1)
- PCA (1)
- PH monitoring in concrete (1)
- PLS regression (1)
- Passive RFID (1)
- Passive sensors (1)
- Person tracking (1)
- Petrol (1)
- Petroleum (1)
- Plume (1)
- Porous building materials (1)
- Portable (1)
- Quantification (1)
- RFID based sensors (1)
- RFID-based sensors (1)
- Rapid test (1)
- Ratiometric fluorescence (1)
- Reactive plume tracking (1)
- Real-time (1)
- Red Phosphorus (1)
- Reinforced concrete (1)
- Remote gas sensor model (1)
- SHM (1)
- Safety region model (1)
- Self-diagnosis (1)
- Self-diagnostic fiber optical sensor (1)
- Sensor (1)
- Sensor calibration and validation (1)
- Sensor requirements (1)
- Sensoren (1)
- Sensors in concrete (1)
- Single cable measuring (1)
- Single cable serial connection (1)
- Small scale test furnace (1)
- Smart structures (1)
- Smartphone (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- Subsurface (1)
- TD-GC-MS (1)
- TG (1)
- TG-FTIR (1)
- TG-MS (1)
- Test Streifen (1)
- Test strip (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thermal resistance (1)
- Transmission characteristics (1)
- UAV (1)
- UL94 (1)
- Ultrasound (1)
- Uncertainty (1)
- Validation (1)
- Water quality (1)
- Water quality control (1)
- Wind estimation (speed and direction) (1)
- Wind vector (1)
- Windvektor (1)
- Wireless mobile sensor device (1)
- Wireless sensor network (WSN) (1)
- agricultural economy (1)
- embedded sensor (1)
- environment (1)
- fluorescence (1)
- gas analysis (1)
- poly(propylene) (PP) (1)
- spectroscopy (1)
- Öl (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (17)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (17)
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.9 Chemische und optische Sensorik (4)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 1.2 Biophotonik (1)
- 8.0 Abteilungsleitung und andere (1)
- VP Vizepräsident (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (1)
Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were presented in a previous study. This paper follows up with results from laboratory and full-scale testing of an further enhanced single cable system for the application in drop tests.----------------------------------------------------------------------------------------------------------------------------------------------------------------
Vielkanalmesssysteme werden zur Messung von Dehnungen und Beschleunigungen bei Fallversuchen von Gefahrstoffbehältern eingesetzt. Konventionelle Systeme erfordern die Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. In einer vorangegangenen Studie wurden vielversprechende Ergebnisse durch Verwendung eines 1-Kabelmesssystems mit Datenbus und dezentraler Datenspeicherung erzielt. Dieser Artikel beinhaltet weiterführende Ergebnisse aus Labor- und Realversuchen mit einem weiterentwickelten System zur Anwendung bei Fallversuchen.
A 400 m² soil test field with gas injection system was built up for the purpose of large-scale validation, optimization, and characterization of a novel comprehensive monitoring method for underground gas storage areas. The method combines gas sensing technology with linear form factor for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct time-series of gas distribution maps based on samples of orthogonally-aligned linear gas sensors. Several injection experiments with carbon dioxide (CO2) at different days with varying boundary conditions indicates the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues.
One of the main unsolved issues of under-ground storages for, e.g., CO2, H2, and natural gas is the comprehensive surveillance of these areas with reasonable effort and costs. Conventional sensors (e.g., soil air probes or borehole probes), however, can only be used for punctual or locally limited measurements; further their application can cause structural influences (invasive application).
In this paper, we describe in detail the setup of a CO2 injection soil test field. This test field will be used to enhance and validate an innovative ap-proach for distributed subsurface monitoring of gas storage areas. To the author’s knowledge, this is the first time that, for this purpose, a test field is built in an application relevant scale.
This paper describes the development of a semi-automatic gas measurement device presenting potentially a broad range of applications, noteworthy in the agricultural sector. Non-reversible fluorescent molecular sensors were designed and syn-thesized. Upon, integration into a hydrogel matrix with an optimal ratio of co-solvents, the sensors reacting selectively to ammonia were illuminated by excitation light to produce a concentration-correlated fluorescence emission. An automated mechanical-elec-trical device initiates a given gas mixture and thus simulates con-centrations similar to a threshold value. The aim of this project is to develop a sensor or a low-cost method which can monitor low concentrations of harmful gases and aid in their elimination or regulation in livestock housing, barns or stables.
Structural Health Monitoring (SHM) is an important topic for Industry 4.0. More and more systems are embedded in different materials and are connected to each other. To embed sensors for a long time in concrete, an exact preparation is required. In this paper, we identify Radio-Frequency Identification (RFID) as promising technology for monitoring of concrete structures. This paper present the concept for long term monitoring, defines the requirements and shows first development steps, for example, the system design, the possibilities of sensor connection, and an encapsulation for embedding in concrete.
Real-time wind estimation on a micro unmanned aerial vehicle using its inertial measurement unit
(2015)
This paper presents an approach for a quadrocoper-based micro unmanned aerial vehicle (UAV) that estimates the wind vector (speed and direction) in real-time based on measurement data of its on-board sensors only. This method does not need any additional airspeed sensor or dedicated anemometer, and thus the micro UAV's valuable payload remains free for other sensors. Wind tunnel and field tests were used to evaluate the performance of the approach. In order to quantify its accuracy, experiments are presented where data was collected with an anemometer placed in an open field with the micro UAV in flight following a predefined trajectory around the anemometer and hovering at a defined position close to it.
Sensor based person tracking is a challenging
topic. The main objective is positioning in areas without
GPS connection, i.e. indoors. A research project is carried
out at BAM, Federal Institute for Materials Research and
Testing, to develop and to validate a multi-sensor system for
3D localization. It combines body motion sensing and a
guard system for the tracking and recording of the status of
persons. The so named BodyGuard system was designed for
sensor-based monitoring and radio-based transmission of
the movement of a person. Algorithms were developed to
transform the sensor data into a spatial coordinate. This
paper describes how the BodyGuard system operates, which
main components were used in the system, how the
individual sensor data are converted into 3D motion data,
with which algorithms the individual sensors are processed,
how individual errors are compensated and how the sensor
data are merged into a 3D Model. Final objective of the
BodyGuard system is to determine the exact location of a
person in a building, e.g. during fire-fighting operations.
Wastewater contains harmful chemicals and heavy metals that are known to cause various environmental and health problems. Therefore, the water quality control using sensitive, simple, fast, accurate, and portable tools is of great importance. This study aimed to evaluate the pollution parameters of wastewaters collected at different treatment stages from a wastewater treatment plant (WWTP) that treats domestic and industrial wastewaters by using an electronic nose (E-nose) and a voltammetric electronic tongue (E-tongue) combined with chemometric techniques. Water and wastewater pollution parameters determination were performed using inductively coupled plasma optical emission spectrometry for the determination of cations, and anions by using ion chromatography. Chemometric techniques, such as Principal Component Analysis (PCA), Discriminant Function Analysis (DFA), Support Vector Machines (SVMs), and Hierarchical Cluster Analysis (HCA), were used to process the E-nose and E-tongue datasets to describe the similarities between the samples. In addition, Partial Least Squares Regression (PLSR) model was constructed using electronic sensing data to simultaneously predict the concentration values of physicochemical parameters. The obtained correlation coefficient, for training and testing sets, is higher than 0.91 for the prediction of the concentration of all physicochemical parameters, except for iron (Fe) which remains 0.84. These results suggest that simple, portable, and inexpensive tools such as electronic nose and tongue are suitable for wastewater analysis.
With the reduction of large oil spills because of stricter regulations and safety measures, the question of how to manage smaller oil spills arises. Few on-site analytical tools are available for first responders or other law enforcement personnel to rapidly test for crude oil in the early management of localized polluted areas. The approach reported here relies on well-described computer-assisted multivariate data analysis of the intrinsic fluorescence fingerprints of crude oils to build a multivariate model for the rapid classification of crude oils and the prediction of their properties. Thanks to a dedicated robust portable reader, the method allowed classification and accurate prediction of various properties of crude oil samples like density (according to API, the American Petroleum Institute and viscosity as well as composition parameters such as volume fractions of paraffins or aromatics. In this way, autonomous operation in on-site or in-the-field applications becomes possible based on the direct (undiluted and untreated) measurement of samples and a rapid, tablet-operated readout system to yield a robust and simple analytical test with superior performance. Testing in real-life scenarios allowed the successful classification and prediction of a number of oil spill samples as well as weathered samples that closely resemble samples collected by first responders.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.