Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (56) (entfernen)
Sprache
- Englisch (48)
- Deutsch (7)
- Mehrsprachig (1)
Referierte Publikation
- nein (56) (entfernen)
Schlagworte
- Nano aerial robot (5)
- Drop test (4)
- Gas sensors (4)
- Monitoring (4)
- RFID sensors (4)
- Structural health monitoring (4)
- Swarm (4)
- Air quality monitoring (3)
- Gas source localization (3)
- Hazardous scenarios (3)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (22)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (22)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.9 Chemische und optische Sensorik (2)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.3 Sicherheit von Transportbehältern (1)
- 6 Materialchemie (1)
- 6.7 Materialsynthese und Design (1)
- 8.6 Faseroptische Sensorik (1)
Temperature characteristics of a piezoresistive accelerometer for high impact shock application
(2018)
This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison.
In preliminary work, gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. In this study, first experimental results are presented for adapting the technology for measuring methane (CH4). A material with suitable selective permeability was identified and utilized in a sensor setup containing the gas selective membrane and a reference membrane, both integrated in a measuring cell, to which a gas stream with defined CH4 concentrations was applied. The results prove the sensor's capability for measuring methane and indicate further application potential of the method, e.g., as a robust field monitoring technology, since CH4 is the major component of natural gas, town gas, and fracking gas.
Long-term completely embedded sensor systems offer innovative possibilities for structural health monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors. This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external reader device. To evaluate characteristics and conditions of this concept, a systematical investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper.
Embedded wireless sensor systems for long-term SHM and corrosion detection in concrete components
(2017)
State-of-the-art communication standards like RFID and Bluetooth Low Energy enable the development of sensor systems which can be completely embedded into concrete components for long-term SHM and early damage detection. Objective of the project KonSens which is carried out at BAM is the development, implementation, and validation of sensors for measuring of Parameters relevant for corrosion, like moisture, pH value, and electrical conductivity, inside steel reinforced concrete components. The primarily addressed application is detection and evaluation of corrosion processes in concrete bridges.
In contrast to cable connected sensors, embedded wireless sensors avoid any pathways for intrusion of moisture and chemicals, e.g., chlorides which could trigger corrosion activity. To allow for long-term, ideally life-time operation, the once embedded sensor systems must work highly energy efficient. One option are passive RFID sensor systems, which work without battery. The energy is transmitted to the system through the electromagnetic field, even to operate sensors. A crucial parameter is the transmission depth in concrete. First experiments with RFID sensors working at frequencies of 13.56 MHz (HF) and 868 MHz (UHF) embedded in concrete specimen resulted positive for transmission depths of up to 13 cm, which is quite promising, considering that corrosion would appear first at the top level of rebars.
A second generation of passive RFID sensor systems has been implemented with improved antenna design. Current experiments using these systems focus on the Transmission characteristics in terms of transmission depths and the impact of concrete moisture. Low-energy humidity sensors are used and analysed regarding their capability for measuring the material moisture. Additionally, a relation between transmitted power to the embedded sensor and the moisture content of the concrete specimen caused by energy absorption can be presumed and is under systematic investigation.
Wireless sensor network for long-term structural health monitoring of buildings and infrastructures
(2009)
Damage commonly occurs in buildings when a component fails suddenly with a
partial or total collapse as a consequence. This type of event leads to serious damage to property
and if it is a bridge or a large hall, then people in particular are at risk. The often great age of
bridges and the increasing volume of traffic (particularly heavy traffic) which they are expected
to carry are in clear contradiction to each other. Thus the probability increases that the loadbearing
capacity of a bridge decreases rapidly and often unnoticed with sometimes dire
consequences.
In order to prevent such accidents, the Federal Institute for Materials Research and Testing is
currently developing a special radio-based, self-configuring measuring system in cooperation
with the Berlin-based ScatterWeb Company. This measuring system consists of a number of
identically designed sensor nodes which are self-sustaining, need no wiring, can act as both
transmitters and receivers and are equipped with a special sensor technology making long-term
monitoring of buildings or engineering facilities possible. The sensor unit uses strain gauges for
stress analysis and contains interfaces for additional sensors. The system in particular applies to
buildings and structures for transport and traffic and large-scale industrial facilities, where a
subsequent wiring installation is difficult or impossible.
The combination of radio-frequency identification (RFID) tags with different types of sensors offers excellent potential for applications with regard to identification, diagnosis, and monitoring. This should be demonstrated by means of two examples of actual developments carried out by the Federal Institute for Materials Research and Testing (BAM). The Identification and diagnosis of concrete components is a major task in the maintenance of critical infrastructure, for instance concrete bridges with heavy traffic volume. A feasibility study investigates the application of RFID sensor systems for this task. The second example reviews the transportation of dangerous goods. Using modern technologies enables promising possibilities to reduce accidents and to avoid non-conformity with transportation regulations. Project results demonstrate an innovative technical solution for monitoring of dangerous goods transports with RFID sensor systems.
Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration.
Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity.
This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g.
This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C.
Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were obtained in laboratory investigations and full-scale drop tests.