Thermographic super resolution techniques allow the spatial resolution of defects/inhomogeneities below the classical limit, which is governed by the diffusion properties of thermal wave propagation. In this work, we report on the extension of this approach towards a full frame 2D super resolution technique. The approach is based on a repeated spatially structured heating using high power lasers. In a second post-processing step, several measurements are coherently combined using mathematical optimization and taking advantage of the (joint) sparsity of the defects in the sample
In diesem Beitrag werden die Möglichkeiten der Ortung von Fehlstellen in Cu Lötverbindungen unterhalb verschiedener Cu Blechdicken mit aktiver Thermografie demonstriert. Dabei wurden die Anregung mit Blitzlicht und die periodische Anregung mit der Lock-In Technik miteinander verglichen. Die Vor- und Nachteile der Anwendung unterschiedlicher IR-Kamerasysteme, einer gekühlten InSb-Quantendetektor IR-Kamera und einer Mikrobolometer IR-Kamera, werden dargestellt. Als objektives Kriterium wurde das SNR für unterschiedliche Fehlstellengrößen herangezogen.
Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden.
Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden.
Optical lock-in thermography is a completely contactless and very sensitive NDE technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive, do not need any work safety measures and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Altogether using lasers considerably increases the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in testing [1, 2]. We report on the mentioned benefits of using such high-power lasers and analyze the range of materials to be tested using lock-in thermography in dependence on the laser irradiance, the modulation frequency, the infrared camera as well as the optical and thermal material parameters. In this context, we also address a number of systematic errors caused by the use of ideal and non-ideal heat sources. For example, the measured phase angle in lock-in thermography depends on the irradiance and the modulation bandwidth of the source. This in turn has a decisive influence on the uncertainty in the quantification of, e.g. layer thicknesses.
Using an infrared camera for radiometric imaging allows the contactless temperature measurement of multiple surface pixels simultaneously. From the measured surface data, a sub-surface structure, embedded inside a sample or tissue, can be reconstructed and imaged when heated by an excitation light pulse. The main drawback in radiometric imaging is the degradation of the spatial resolution with increasing depth, which results in blurred images for deeper lying structures. We circumvent this degradation with blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The ground-breaking concept of super-resolution can be transferred from optics to thermographic imaging.
Photothermal radiometry with an infrared camera allows the contactless temperature measurement of multiple surface pixels simultaneously. A short light pulse heats the sample. The heat propagates through the sample by diffusion and the corresponding temperature evolution is measured at the sample’s surface by an infrared camera. The main drawback in radiometric imaging is the loss of the spatial resolution with increasing depth due to heat diffusion, which results in blurred images for deeper lying structures. We circumvent this information loss due to the diffusion process by using blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The structured illumination is realized by parallel laser lines from a vertical-cavity surface-emitting laser (VCSEL) array controlled by a random binary pattern generator. By using 150 different patterns of structured illumination and our iterative joint sparsity algorithm, it was possible to resolve 1 mm thick lines at a distance down to 0.5 mm, which results in a resolution enhancement of approximately a factor of four compared to the resolution of 5.9 mm for homogenous illuminated thermographic reconstruction.
The paper presents an attempt for the calibration of an active
thermography method that is suitable for the non-destructive
evaluation of spot welds. Nowadays, the quality of spot welds is
commonly characterised by the application of random chisel tests,
which are time consuming, expensive and destructive. Recently a
non-destructive testing method by means of active thermography
was proposed that relies on the fact that the mechanical connection
formed by the spot weld also serves as a thermal bridge between
the two steel sheets joined in the welding process. It is shown in this
paper that this thermal bridge can be thermographically characterised
by extracting a measure for the spot weld diameter and hence the
quality of the spot weld. The determination of the absolute value
of the diameter hereby relies on a calibration of the testing system,
which is performed by means of X-ray computed tomography in this
study. The experiments were carried out using different experimental
approaches, namely transmission as well as reflection geometry
wSetup in reflectionith laser illumination. A comprehensive evaluation
of samples produced using different welding currents, hence different
quality, was carried out in order to validate the thermographic results.
Single-pulse tests of the catastrophic optical damage (COD) are performed for three batches of diode lasers with different gain-regions. The tests involve in situ inspection of front, rear, and side of the devices by a thermocamera. Devices with an Al-containing gain-region show COD at the front facet, as expected for strong facet heating via surface recombination and reabsorption of laser light. In contrast, Al-free devices with low surface recombination rates tend to fail at the rear facet, pointing to a different heating scenario. The high carrier density at the rear facet favors heating and COD via Auger recombination processes.