Thermographic super resolution techniques allow the spatial resolution of defects/inhomogeneities below the classical limit, which is governed by the diffusion properties of thermal wave propagation. In this work, we report on the extension of this approach towards a full frame 2D super resolution technique. The approach is based on a repeated spatially structured heating using high power lasers. In a second post-processing step, several measurements are coherently combined using mathematical optimization and taking advantage of the (joint) sparsity of the defects in the sample
In diesem Beitrag werden die Möglichkeiten der Ortung von Fehlstellen in Cu Lötverbindungen unterhalb verschiedener Cu Blechdicken mit aktiver Thermografie demonstriert. Dabei wurden die Anregung mit Blitzlicht und die periodische Anregung mit der Lock-In Technik miteinander verglichen. Die Vor- und Nachteile der Anwendung unterschiedlicher IR-Kamerasysteme, einer gekühlten InSb-Quantendetektor IR-Kamera und einer Mikrobolometer IR-Kamera, werden dargestellt. Als objektives Kriterium wurde das SNR für unterschiedliche Fehlstellengrößen herangezogen.
Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden.
Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden.
Optical lock-in thermography is a completely contactless and very sensitive NDE technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive, do not need any work safety measures and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Altogether using lasers considerably increases the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in testing [1, 2]. We report on the mentioned benefits of using such high-power lasers and analyze the range of materials to be tested using lock-in thermography in dependence on the laser irradiance, the modulation frequency, the infrared camera as well as the optical and thermal material parameters. In this context, we also address a number of systematic errors caused by the use of ideal and non-ideal heat sources. For example, the measured phase angle in lock-in thermography depends on the irradiance and the modulation bandwidth of the source. This in turn has a decisive influence on the uncertainty in the quantification of, e.g. layer thicknesses.
Using an infrared camera for radiometric imaging allows the contactless temperature measurement of multiple surface pixels simultaneously. From the measured surface data, a sub-surface structure, embedded inside a sample or tissue, can be reconstructed and imaged when heated by an excitation light pulse. The main drawback in radiometric imaging is the degradation of the spatial resolution with increasing depth, which results in blurred images for deeper lying structures. We circumvent this degradation with blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The ground-breaking concept of super-resolution can be transferred from optics to thermographic imaging.
Photothermal radiometry with an infrared camera allows the contactless temperature measurement of multiple surface pixels simultaneously. A short light pulse heats the sample. The heat propagates through the sample by diffusion and the corresponding temperature evolution is measured at the sample’s surface by an infrared camera. The main drawback in radiometric imaging is the loss of the spatial resolution with increasing depth due to heat diffusion, which results in blurred images for deeper lying structures. We circumvent this information loss due to the diffusion process by using blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The structured illumination is realized by parallel laser lines from a vertical-cavity surface-emitting laser (VCSEL) array controlled by a random binary pattern generator. By using 150 different patterns of structured illumination and our iterative joint sparsity algorithm, it was possible to resolve 1 mm thick lines at a distance down to 0.5 mm, which results in a resolution enhancement of approximately a factor of four compared to the resolution of 5.9 mm for homogenous illuminated thermographic reconstruction.
The paper presents an attempt for the calibration of an active
thermography method that is suitable for the non-destructive
evaluation of spot welds. Nowadays, the quality of spot welds is
commonly characterised by the application of random chisel tests,
which are time consuming, expensive and destructive. Recently a
non-destructive testing method by means of active thermography
was proposed that relies on the fact that the mechanical connection
formed by the spot weld also serves as a thermal bridge between
the two steel sheets joined in the welding process. It is shown in this
paper that this thermal bridge can be thermographically characterised
by extracting a measure for the spot weld diameter and hence the
quality of the spot weld. The determination of the absolute value
of the diameter hereby relies on a calibration of the testing system,
which is performed by means of X-ray computed tomography in this
study. The experiments were carried out using different experimental
approaches, namely transmission as well as reflection geometry
wSetup in reflectionith laser illumination. A comprehensive evaluation
of samples produced using different welding currents, hence different
quality, was carried out in order to validate the thermographic results.
Single-pulse tests of the catastrophic optical damage (COD) are performed for three batches of diode lasers with different gain-regions. The tests involve in situ inspection of front, rear, and side of the devices by a thermocamera. Devices with an Al-containing gain-region show COD at the front facet, as expected for strong facet heating via surface recombination and reabsorption of laser light. In contrast, Al-free devices with low surface recombination rates tend to fail at the rear facet, pointing to a different heating scenario. The high carrier density at the rear facet favors heating and COD via Auger recombination processes.
Impact damages and delaminations in fibre-reinforced composites (FRC) might not be visible at the surface, but could have an influence on the resistance and on the long-term behaviour of the component. Therefore, and especially for safety relevant structures, non-destructive methods are required for the assessment of such damages.
Active thermography methods are suitable to characterize damages after loading using different kind of excitation techniques and various configurations of infrared (IR) camera and heating sources. Here, flash lamps, impulse excitation with infrared radiator and lock-in technique with halogen lamps or widened laser beams are suited. In addition, non-optical sources like sonotrodes (requiring direct contact to the structure) or induction generators (only suited for carbon fibre reinforced polymer (CFRP) structures) could be applied as well. For the investigation of the evolution of the damage during the impact, passive thermography can be applied in-situ. Elastic and plastic deformations alter the temperature of the structure and thus the temperature on the surface.
In this contribution, at first the general principles of quantitative defect characterisation in FRC using active thermography with flash, impulse and lock-in excitation are described. Optical and thermal properties of the FRC material and its anisotropy are considered. Results of phase differences obtained at flat bottom holes with flash and lock-in thermography are compared for qualifying both methods for quantitative defect characterization. Secondly, the damage evolution of CFRP and GFRP structures under impact load and static tensile loading is described. The spatial and temporal evolution of the surface temperature enables us to distinguish matrix cracks or fibre-matrix separation from delaminations between the layers. Afterwards, all results for loading defects, obtained by passive and active thermography, are compared with each other. Fig. 1 and 2 show the difference of passive and flash thermography obtained at impact and tensile loaded CFRP plates, respectively. As one purpose of these investigations is the development of standards within national (DIN) and European (CEN) standardisation bodies, new draft and final standards are presented and further needs are discussed at the end of the presentation.
Classification of Spot-Welded Joints in Laser Thermography Data Using Convolutional Neural Networks
(2021)
Spot welding is a crucial process step in various industries. However, classification of spot welding quality is still a tedious process due to the complexity and sensitivity of the test material, which drain conventional approaches to its limits. In this article, we propose an approach for quality inspection of spot weldings using images from laser thermography data. We propose data preparation approaches based on the underlying physics of spot-welded joints, heated with pulsed laser thermography by analyzing the intensity over time and derive dedicated data filters to generate training datasets. Subsequently, we utilize convolutional neural networks to classify weld quality and compare the performance of different models against each other. We achieve competitive results in terms of classifying the different welding quality classes compared to traditional approaches, reaching an accuracy of more than 95 percent. Finally, we explore the effect of different augmentation methods.
Vertical Cavity Surface Emitting Lasers (VCSELs) sind Diodenlaser, welche Laserstrahlung mit gutem Strahlprofil senkrecht zur Chipoberfläche emittieren. Aufgrund dieser vertikalen Bauweise können sie in großen Arrays zu vielen tausenden einzelnen Lasern zusammengefasst werden. Solch ein VCSEL-Array vereint das schnelle zeitliche Verhalten eines Diodenlasers mit der hohen optischen Bestrahlungsstärke und dem großen Beleuchtungsbereich von Blitzlampen oder LEDs und kann damit potentiell alle herkömmlichen Lichtquellen der Thermografie ersetzen.
Darüber hinaus kann der Prüfkörper mithilfe dieser Lichtquelle strukturiert erwärmt werden, da einzelne Bereiche des VCSEL-Arrays unabhängig voneinander angesteuert werden können. Dieser neue Freiheitsgrad ermöglicht die Entwicklung neuer thermografischer ZfP-Verfahren. Wir demonstrieren diesen Ansatz anhand eines für die konventionelle Thermografie nur sehr bedingt lösbaren Prüfproblems, der Detektion vertikal zur Oberfläche ausgerichteter, sehr dünner, verdeckter Defekte in metallischen Werkstoffen. Wir erzeugen hierzu destruktiv interferierende thermische Wellenfelder. Defekte im Einflußbereich dieser thermischen Wellenfelder stören die destruktive Interferenz und erlauben eine hochsensible Detektion bis in Tiefen jenseits der üblichen thermografischen Faustformel, ohne Referenz und ohne Oberflächenbehandlung.
Crack detection in steel bars at high surface temperatures is a critical problem in any manufacturing industry. Surface breaking cracks are the major problems during the billet casting. Many NDT techniques are proven its capability in crack detection at room temperature. Here, we are demonstrating the possibility of exposure of cracks using laser line thermography at higher surface temperatures (up to 600 °C). A continuous-wave (CW) laser is used to excite the sample kept at higher surface temperatures. The temperature distribution over the sample due to the laser line scanning is captured using a temperature calibrated infrared (IR) thermal camera. The response of the sample temperature in crack detection is investigated using a validated FE model. The impact of the oxide layer in crack detection is investigated by using two types of samples; one without any oxide layer and the second is with the oxide layer. The influence of laser power in the detection of defects at high temperatures is studied. 3D numerical models were developed for the cases; when the sample is with oxide layer and without any oxide layer for a better understanding of physics. The surface temperature rise due to laser heating is higher for the scaled sample compared to the no-scale sample. The presence of the oxide layer above the parent metal will reduce the reflectivity of the surface. Lower reflectivity will lead to increased absorption of incident energy so that the surface temperature rise will be higher than the surface with no scale. Thermal contrast linearly depends on laser power, which means higher laser power will increase the defect detectability even at a higher surface temperature.
In this work, we report on our progress for investigating a new experimental approach for thermographic detection of internal defects by performing 2D photothermal super resolution reconstruction. We use modern high-power laser projector technology to repeatedly excite the sample surface photothermally with varying spatially structured 2D pixel patterns. In the subsequent (blind) numerical reconstruction, multiple measurements are combined by exploiting the joint-sparse nature of the defects within the specimen using nonlinear convex optimization methods. As a result, a 2D-sparse defect/inhomogeneity map can be obtained. Using such spatially structured heating combined with compressed sensing and computational imaging methods allows to significantly reduce the experimental complexity and to study larger test surfaces as compared to the one-dimensional approach reported earlier.
Detection of surface breaking cracks using flying line laser thermography: A Canny-based algorithm
(2021)
In this work, we introduce a new algorithm for effectual crack detection using flying line laser thermography, based on the well-known Canny approach. The algorithm transforms the input thermographic sequence into an edge map. Experimental measurements are performed on a metallic component that contains surface breaking cracks due to industrial use. The specimen is tested using flying line thermography at different scanning speeds and laser input powers. Results obtained with the proposed algorithm are additionally compared with a previously established algorithm for flying spot thermography. The proposed Canny-based algorithm can be used in automated systems for thermographic non-destructive testing.
We present an all-purpose crack detection algorithm for flying spot thermography which is directly applicable to a thermogram sequence without the need of any additional information about the experimental setup. A single image containing distinct crack signatures is derived in two steps. Firstly, the spatial derivative is calculated for each frame of the sequence and, secondly, the resulting data set is sorted pixel wise along the time axis. The feasibility of the proposed procedure is proven by testing a piece of rail that comprises roll contact fatigue cracks and by comparing the results with magnetic particle testing.