Impulse-thermography has been established as a fast and reliable tool in many areas of non-destructive testing. In recent years several investigations have been done to apply active thermography to civil engineering. For quantitative investigations in this area of application, finite difference calculations have been performed for systematic studies on the influence of environmental conditions, heating power and time, defect depth and size and thermal properties of the bulk material (concrete). The comparison of simulated and experimental data enables the quantitative analysis of defects.
New thermography systems enable the application of active investigation techniques, i.e. the observation of the cooling down process after heating the surface of a structure under investigation. Defects like voids in concrete having a different thermal diffusivity in comparison to the bulk material are visualised by different surface temperatures. The differences between temperature transient curves above sound regions and above inhomogeneities are expected to include information about the defect parameters.
Experimental investigations with impulse thermography and radar on a concrete test specimen containing voids were analysed. Radar was used to determine the depth of the voids. The influence of size and depth of the voids on the temperature transient curves was studied for different heating times. The transient curves were also fitted with a simple semi-empirical model.
Impulse-thermography is an active method for quantitative investigations of the near surface region of various structures. It has recently been applied and optimised to applications in civil engineering. By using either an internal or external heat source, parts of the structure under investigation are heated up and the transient heat flux is observed by recording the temperature change at the surface as a function of time. This method is very well suited for the detection of voids and honeycombing in concrete, up to concrete covers of 10 cm as well as for the location of delaminations in multi-layered systems (e.g. plaster on concrete, CFRP-laminates on concrete, asphalt on concrete). Also safety relevant defects like voids in tendon ducts and cracks in concrete could be recognised.
Impulse-thermography is an active method for quantitative investigation of the near surface region of various structures which has recently been applied to civil engineering. It is well suited for the detection of voids and honeycombing in concrete up to concrete covers of 10 cm and more. For quantitative analysis, a computer program for numerical simulation of the heating up and cooling down processes was developed based on Finite Differences. With this program parameter studies have been performed for investigating the influence of environmental conditions, material parameters and geometry on the thermal behaviour. The comparison between experimental and simulated results enables the Inverse Solution.