Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (55)
- Vortrag (51)
- Zeitschriftenartikel (18)
- Posterpräsentation (14)
- Beitrag zu einem Sammelband (7)
- Forschungsbericht (2)
- Dissertation (1)
- Sonstiges (1)
Sprache
- Deutsch (76)
- Englisch (72)
- Mehrsprachig (1)
Schlagworte
- Ferroelectret (26)
- Luftultraschall (21)
- Air-coupled (14)
- Transducer (14)
- Cellular polypropylene (13)
- Ferroelektret (12)
- Luftgekoppelte Ultraschallprüfung (11)
- Air-coupled ultrasound (10)
- Thermoakustik (10)
- Ultraschallwandler (9)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (56)
- 8.4 Akustische und elektromagnetische Verfahren (51)
- 6 Materialchemie (6)
- 6.1 Oberflächen- und Dünnschichtanalyse (6)
- 5 Werkstofftechnik (5)
- 5.3 Polymere Verbundwerkstoffe (5)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (5)
- 8.0 Abteilungsleitung und andere (3)
- 8.5 Röntgenbildgebung (1)
- 9 Komponentensicherheit (1)
- 9.5 Tribologie und Verschleißschutz (1)
Eingeladener Vortrag
- nein (51)
Die übergeordnete Zielsetzung unserer Untersuchung bestand darin,
am Beispiel von Prüfungen mit Ultraschall eine belastbare Aussage zum Einfluss der Arbeitsbedingungen des Prüfers auf die Qualität der Ergebnisse von zerstörungsfreien Prüfungen zu ermitteln und Möglichkeiten zur Minimierung ungünstiger Einflussfaktoren aufzuzeigen.
Der Schwerpunkt der Untersuchung wurde auf die manuelle Ultraschallprüfung gelegt und der Faktor 'Zeitdruck' (in drei Stufen variiert) als die zu variierende physische Einflussgröße gewählt. Die Variation des Faktors Zeitdruck wurde gemäß dem Prozessmodell von der Erhebung psychologischer Faktoren, die das Individuum und die Organisation beschreiben, begleitet.
Die Ultraschallprüfungen erfolgten mit zehn Prüfern am Großbehälter und an Vergleichskörpern mit eingebrachten Testfehlern (Nuten, Risse). Die ausgewählten Fehler waren typisch für Prüfaufgaben, die bei wiederkehrenden Ultraschallprüfungen in Kernkraftwerken von den Prüfern zu lösen sind. Die Prüfaufgabe bestand darin, die in den vorgegebenen Prüfabschnitten vorhandenen Reflektoren aufzufinden und deren Amplituden, Ortskoordinaten und Längenerstreckungen zu ermitteln. Als Bewertungsmaßstab für die Qualität der Prüfaussage und für den Einfluss des menschlichen Faktors diente die Präzision der gemessenen Werte. Die Ergebnisse zeigen einen hohen Einfluss des menschlichen Faktors auf das Prüfergebnis und eine Einwirkung des Zeitdrucks besonders auf die Präzision der Messwerte. Hierbei war die Wirkung des individuell wahrgenommenen Zeitdrucks zusammen mit der psychischen Arbeitsbeanspruchung signifikant. Es wurde unter anderem herausgearbeitet, dass durch eine gute Vorbereitung auf die Prüfung, z.B. durch die sorgfältige Einweisung und ein vorgeschaltetes Fertigkeitstraining an Vergleichskörpern, die Zuverlässigkeit der Prüfergebnisse verbessert werden kann.
Insgesamt hatte der Faktor 'Organisation' neben der 'Erfahrung' einen hohen Einfluss auf das Leistungsvermögen der Prüfer.
Die Projektergebnisse wurden im Abschlussbericht des Forschungsvorhabens SR2514 dargestellt, es wurden drei Empfehlungen zur Vorbereitung und Einweisung der Prüfer, zur Stärkung der Verantwortung der Prüfaufsicht und zum 4-Augen-Prinzip formuliert. Die Empfehlungen wurden in der KTA- Regel 3201.4 'Komponenten des Primärkreises von Leichtwasserreaktoren; Teil 4: Wiederkehrende Prüfungen und Betriebsüberwachung (RÄE Fassung 2010-11)', umgesetzt.
This paper gives an introduction to the field of human factors with the focus on their influence on the reliability of NDT in the nuclear energy production (in-service inspections) and final storage of highly radioactive nuclear waste. A set of methodological tools has been developed in the scope of three projects, namely: 1) a theoretical model describing potential human factors influencing manual ultrasonic inspection performance during inservice inspections in nuclear power plants; 2) a method for identifying potential human errors during acquisition and evaluation of data gathered with mechanized ultrasonic, radiographic and eddy-current systems, as well as visual testing with a remote camera (Failure Modes and Effects Analysis, FMEA); and 3) use of eye tracking methodology to optimize existing procedures and practices. The experimental results have shown that time pressure, mental workload and experience influence the quality of the inspection performance. Noticeable were influences from the organization of the working schedule, communication, procedures, supervision and demonstration task. Implementing human redundancy in critical tasks, such as defect identification, as well as using an automated aid (software) to help operators in decision making about the existence and size of defects, could lead to other kinds of problems, namely social loafing (excerpting less effort when working on tasks collectively as compared to working alone) and automation bias (uncritical reliance on the proper function of an automated system without recognizing its limitations and the possibilities of automation failure) that might affect the reliability of NDT in an undesired manner.
Ferroelectrets are promising materials for air-coupled ultrasonic transducers. A transducer made of polarized cellular polypropylene, including its electronic interface, was developed and compared with conventional air-coupled probes. Test pieces of fiber-reinforced polymer containing impact flaws and flat-bottom holes were inspected in transmission. The ferroelectret transducers achieved a considerably higher signal-to-noise ratio. The impacts were clearly visible with all transducers, but less noisy with ferroelectret transducers. The flat-bottom holes were better detectable than with a conventional probe with about the same focus size.
Für die luftgekoppelte Ultraschall-Prüfung wird der Prototyp eines neuartigen Prüfkopfes vorgestellt. Statt eines piezokeramischen Ultraschall-Wandlers mit einer λ/4-Anpassschicht wird eine Ferroelektret-Folie aus schaumförmigem Polypropylen eingesetzt. Durch die außerordentlich geringe akustische Impedanz der Folie reduzieren sich die Reflexionsverluste an den Grenzschichten zur Luft so stark, dass bei diesem Prüfkopf auf eine λ/4-Anpassschicht verzichtet werden kann. Außerdem ist die Folie hochspannungsfest. Sie konnte mit Spannungen von mehr als 3500 V angesteuert werden und erlaubte eine Vorspannung am Ultraschall-Wandler des Empfangsprüfkopfes von 2000 V. Mithilfe der hohen Anregungsspannung stieg die Amplitude des akustischen Prüfimpulses auf das 11,2-Fache. Die Empfindlichkeit des Empfängers erhöhte sich durch die Vorspannung weiter um den Faktor 4,3. Insgesamt steigt die Amplitude am Empfänger also auf das 48-Fache, bei gleichbleibendem Rauschpegel. Ein abschließender Vergleich mit kommerziellen Luftultraschall-Prüfköpfen belegt die Überlegenheit der Folien-Prüfköpfe. Damit rückt der Einsatz einer vollwertigen Impuls-Echo-Technik auch bei der luftgekoppelten Ultraschallprüfung deutlich näher.
The total reliability of a mine searching system is driven by the triple of intrinsic
capability, which describes the physical-technical basis capability, the application and
environmental factors and the human factors. Some of them can be determined in
laboratory measurements but the human factor and a part of environment conditions
and their interaction with the device need to be treated statistically. That is why the
test & evaluation procedure described in CEN CWA 14747:2003, includes in addition
to parameter tests of metal detectors also the reliability or blind field tests under local
conditions with local personnel. A series of three big field trials had been
accomplished in the ITEP-project 2.1.1.2 Reliability Model for Test & Evaluation of
Metal Detectors to specify the optimum conditions for reliable trial results with
affordable effort. For each set of specific working conditions, characterized in terms
of a combination of one mine type in one soil with one detector handled by local
personnel, the searching system will show up a working performance in mine
detection rates as a function of mine depth and show up a certain overall false call
rate. During the ITEP-trials in Benkovac and Oberjettenberg the authors learnt to
determine this function separately for each mine type in each soil, which is especially
important for low metal mines in uncooperative soil which will be illustrated for the
mine PMA2 in different types of soil. The question of representativeness for field
conditions on the one hand and necessary statistical set up for the possibility to
distinguish between individual detector performances is still under discussion.