Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (55)
- Vortrag (51)
- Zeitschriftenartikel (18)
- Posterpräsentation (14)
- Beitrag zu einem Sammelband (7)
- Forschungsbericht (2)
- Dissertation (1)
- Sonstiges (1)
Sprache
- Deutsch (76)
- Englisch (72)
- Mehrsprachig (1)
Schlagworte
- Ferroelectret (26)
- Luftultraschall (21)
- Air-coupled (14)
- Transducer (14)
- Cellular polypropylene (13)
- Ferroelektret (12)
- Luftgekoppelte Ultraschallprüfung (11)
- Air-coupled ultrasound (10)
- Thermoakustik (10)
- Ultraschallwandler (9)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (56)
- 8.4 Akustische und elektromagnetische Verfahren (51)
- 6 Materialchemie (6)
- 6.1 Oberflächen- und Dünnschichtanalyse (6)
- 5 Werkstofftechnik (5)
- 5.3 Polymere Verbundwerkstoffe (5)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (5)
- 8.0 Abteilungsleitung und andere (3)
- 8.5 Röntgenbildgebung (1)
- 9 Komponentensicherheit (1)
Eingeladener Vortrag
- nein (51)
We designed micro-hollow cathode discharge prototypes under atmospheric pressure and investi-gated their acoustic characteristics. For the acoustic model of the discharge, we correlated the self-organisation effect of the current density distribution with the ideal model of an acoustic membrane. For validation of the obtained model, sound particle velocity spectroscopy was used to detect and analyse the acoustic emission experimentally. The results have shown a behaviour similar to the ideal acoustic membrane. Therefore, the acoustic excitation is decomposable into its eigenfrequencies and predictable. The model was unified utilising the gas exhaust velocity caused by the electrohydrodynamic force. The results may allow a contactless prediction of the current density distribution by measuring the acoustic emission or using the micro-discharge as a tunable acoustic source for specific applications as well.
Air-coupled ultrasound (ACU) is increasingly used for automated and contactless inspection of large-scale composite structures as well as for non-destructive testing (NDT) of water-sensitive or porous materials. The major challenge to overcome using ACU in NDT is the enormous loss of ultrasonic energy at each solid-air interface caused by the high acoustic impedance mismatch. Resonant low-frequency piezoceramic transducers are specially designed to achieve high sound pressure levels. For an expanded use of this technique, however, the spatial resolution needs to be increased.
Recent studies of our collaborative research group demonstrated the successful application of a resonance-free, highly sensitive receiver that uses a Fabry-Pérot etalon instead of piezoceramic materials or membranes. However, to reach the full potential of this broadband small-aperture optical microphone, novel transmitter concepts have to be developed and evaluated for advanced NDT applications.
Different types of transmitter were tested in combination with the optical microphone acting as receiver and they were compared to conventional piezoceramic transducers in through-transmission mode. Monolithic carbon fiber-reinforced plastics (CFRP) and CFRP sandwich structures containing different defect types were inspected. Presented results are processed as C-scan images and further evaluated for spatial resolution, signal-to-noise ratio and sensitivity of each measurement setup. Novel transmitter concepts, such as ferroelectret and thermoacoustic emitters, show promising findings with a considerably improved time and spatial resolution for ACU-NDT.
Commercially available air-coupled transducers applied in non-destructive testing consist of a piezocomposite material and matching layers to reduce the impedance mismatch between the transducer and air. This contribution is an overview of innovative approaches using new piezoelectric materials and other physical principles to transmit and receive an ultrasonic pulse in air. Capacitive and piezoelectric micromachined ultrasonic transducers (CMUTs and PMUTs) produce high pressure levels, but they exhibit a very narrow bandwidth. Optical laser-based methods for transmitting and receiving ultrasound promise a higher bandwidth, but do not achieve the same sensitivity as conventional air-coupled transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties, having a very small acoustic impedance well matched to air. Ferroelectret transducers achieve about the same bandwidth as the most broadband conventional air-coupled transducers, having a higher sensitivity. Thermoacoustic transducers use heat to initiate an acoustic wave, acting as transmitters in ultrasonic range. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing. The newest member of the family of air-coupled ultrasonic transmitters is the plasma-based transducer, using both the thermoacoustic effect and the movements of the ions (so called ionic wind) to create acoustic waves.
Conventional ultrasonic testing involves the application of a fluid couplant for impedance matching. Increasing use of lightweight structures, composite materials and adhesive joints mostly in aerospace and automotive industry created an increasing interest in air-coupled ultrasonic testing methods, to protect sensitive surfaces and simplify maintenance. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers to reduce the impedance mismatch between the transducer and air. This contribution is an overview of innovative approaches using new piezoelectric materials and other physical principles to transmit and receive an ultrasonic pulse in air.
Capacitive and piezoelectric micromachined ultrasonic transducers (CMUTs and PMUTs) produce high pressure levels, but they exhibit a very narrow bandwidth. Optical laser-based methods for transmitting and receiving ultrasound promise a higher bandwidth, but do not achieve the same sensitivity as conventional air-coupled transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties, having a very small acoustic impedance well matched to air. Ferroelectret transducers achieve about the same bandwidth as the most broadband conventional air-coupled transducers, having a higher sensitivity. Thermoacoustic transducers use heat to initiate an acoustic wave, acting as transmitters in ultrasonic range. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing. The newest member of the family of air-coupled ultrasonic transmitters is the plasma-based transducer, using both the thermoacoustic effect and the movements of the ions (so called ionic wind) to create acoustic waves.
Air-coupled ferroelectret ultrasonic transducers applied to testing of fiber-reinforced polymers
(2013)
The necessity and demand for nondestructive testing of wood-based materials which can automatically scan huge areas of wood is increasing. Air-coupled ultrasound (ACU) is used to detect defects and damage without altering the structure permanently. Using through transmission it is possible to detect even small holes and missing adhesive. If only one side of an object is accessible the reflection mode is preferred at the expense of a reduced resolution and penetration depth. Novel ferroelectret transducers with a high signal-to-noise ratio (SNR) enable a high-precision structure recognition. The transducers made of cellular polypropylene (PP) are quite suitable for ACU testing due to their extremely low Young’s modulus and low density which result in a favorable acoustic impedance for the transmission of ultrasonic waves between the transducer and air. Thus, defects such as delamination, rot, and cracks can be detected. Promising results were obtained under laboratory conditions with frequencies from 90 kHz to 200 kHz. The advantage of these ACU transducers is that they do not require contact to the sample, are accurate, and cost effective. Ultrasonic quality assurance for Wood is an important attempt to increase the acceptance of wooden structures and towards sustainability in civil engineering in general.
High sensitivity is an important requirement for air-coupled ultrasonic sensors applied to materials testing. With a lower acoustic impedance than any piezoelectric material, charged cellular polypropylene (PP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric properties of charged cellular PP originate from their polarization, creating permanent internal voltage. The sensitivity of the sensor can be increased by applying additional dc bias voltage, as it has been done already for transmitters. This work presents the first ultrasonic sensor based on charged cellular PP including a high-voltage module providing dc bias voltage up to 2 kV. This bias voltage led to an increase in the signal-to-noise ratio of up to 15 ± 1 dB. The measurement of the received signal depending on the applied bias voltage is proposed as a new method of determining the internal voltage of ferroelectrets. The sensor combined with a cellular PP transmitter was applied to nondestructive testing of a rotor blade segment and glued-laminated timber, enabling imaging of the internal structure of these specimens with a thickness around 4 cm.
Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio.
Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio.
Common air-coupled transducers for non-destructive testing consist of a piezocomposite material and several matching layers. Better acoustical matching to air is achieved by transducers based on charged cellular polypropylene (PP). This material has about hundred times lower acoustic impedance than any piezocomposite, having about the same piezoelectric coefficient. The piezoelectric properties of cellular PP are caused by the polarization of air cells. Alternatively, a ferroelectret receiver can be understood as a capacitive microphone with internal polarization creating permanent internal voltage. The sensitivity of the receiver can be increased by applying additional bias voltage. We present an ultrasonic receiver based on cellular PP including a high-voltage module providing bias voltage up to 2 kV. The application of bias voltage increased the signal by 12 to 15 dB with only 1 dB increase of the noise.
This receiver was combined with a cellular PP transmitter in through transmission to inspect several test specimens consisting of glass-fiber-reinforced polymer face sheets and a porous closed-cell PVC core. These test specimens were inspected before and after load. Fatigue cracks in the porous PVC core and some fatigue damage in the face sheets were detected. These test specimens were originally developed to emulate a rotor blade segment of a wind power plant. Similar composite materials are used in lightweight aircrafts for the general aviation. The other inspected test specimen was a composite consisted of glass-fiber-reinforced polymer face sheets and a wooden core. The structure of the wooden core could be detected only with cellular PP transducers, while commercial air-coupled transducers lacked the necessary sensitivity. Measured on a 4-mm thick carbon-fiber-reinforced polymer plate, cellular PP transducers with additional bias voltage achieved a 32 dB higher signal-to-noise ratio than commercial air-coupled transducers.