Conventional ultrasonic testing involves the application of a fluid couplant for impedance matching. Increasing use of lightweight structures, composite materials and adhesive joints mostly in aerospace and automotive industry created an increasing interest in air-coupled ultrasonic testing methods, to protect sensitive surfaces and simplify maintenance. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers to reduce the impedance mismatch between the transducer and air. This contribution is an overview of innovative approaches using new piezoelectric materials and other physical principles to transmit and receive an ultrasonic pulse in air.
Capacitive and piezoelectric micromachined ultrasonic transducers (CMUTs and PMUTs) produce high pressure levels, but they exhibit a very narrow bandwidth. Optical laser-based methods for transmitting and receiving ultrasound promise a higher bandwidth, but do not achieve the same sensitivity as conventional air-coupled transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties, having a very small acoustic impedance well matched to air. Ferroelectret transducers achieve about the same bandwidth as the most broadband conventional air-coupled transducers, having a higher sensitivity. Thermoacoustic transducers use heat to initiate an acoustic wave, acting as transmitters in ultrasonic range. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing. The newest member of the family of air-coupled ultrasonic transmitters is the plasma-based transducer, using both the thermoacoustic effect and the movements of the ions (so called ionic wind) to create acoustic waves.
Common air-coupled transducers for non-destructive testing consist of a piezocomposite material and several matching layers. Better acoustical matching to air is achieved by transducers based on charged cellular polypropylene (PP). This material has about hundred times lower acoustic impedance than any piezocomposite, having about the same piezoelectric coefficient. The piezoelectric properties of cellular PP are caused by the polarization of air cells. Alternatively, a ferroelectret receiver can be understood as a capacitive microphone with internal polarization creating permanent internal voltage. The sensitivity of the receiver can be increased by applying additional bias voltage. We present an ultrasonic receiver based on cellular PP including a high-voltage module providing bias voltage up to 2 kV. The application of bias voltage increased the signal by 12 to 15 dB with only 1 dB increase of the noise.
This receiver was combined with a cellular PP transmitter in through transmission to inspect several test specimens consisting of glass-fiber-reinforced polymer face sheets and a porous closed-cell PVC core. These test specimens were inspected before and after load. Fatigue cracks in the porous PVC core and some fatigue damage in the face sheets were detected. These test specimens were originally developed to emulate a rotor blade segment of a wind power plant. Similar composite materials are used in lightweight aircrafts for the general aviation. The other inspected test specimen was a composite consisted of glass-fiber-reinforced polymer face sheets and a wooden core. The structure of the wooden core could be detected only with cellular PP transducers, while commercial air-coupled transducers lacked the necessary sensitivity. Measured on a 4-mm thick carbon-fiber-reinforced polymer plate, cellular PP transducers with additional bias voltage achieved a 32 dB higher signal-to-noise ratio than commercial air-coupled transducers.
Die physikalische Komplexität der Gasentladungen führt zu vielen Möglichkeiten für die Interaktion der Entladung mit ihrer Umgebung. Zu den typischen Anwendungen zählen Modifikationen der Materialoberflächen und Erzeugung von Ionen für Massenspektroskopie. Atmosphärendruckplasma generiert eine große Menge thermischer Energie wegen der Kollisionen in der Plasmarandschicht. Eine rasche Temperaturänderung kann in dem umgebenden Gas eine akustische Welle erzeugen, wie beim Blitz und Donner, was als thermoakustischer Effekt bekannt ist. Außerdem kann auch die Bewegung der Ladungsträger im elektrischen Feld, bekannt als ionischer Wind, eine akustische Welle erzeugen.
In diesem Beitrag werden Versuche mit akustischer Emission von Plasma bei dielektrischer Oberflächenentladung und bei Mikrohohlkathoden dargestellt. Es werden auch mögliche Anwendungen für Plasmadiagnostik, sowie für den Bau von Schallwandlern für den Hör- und Ultraschallbereich präsentiert. Verglichen mit anderen Methoden der Schallerzeugung, hat die thermoakustische Anregung den Vorteil, dass sie auch ohne eine schwingende Masse auskommt, womit eine große Bandbreite erreicht wird, sowie den Vorteil einer guten Anpassung der akustischen Impedanz.
The application of phased arrays in either linear or matrix arrangement in combination with signal processing opens the door for the mechanized inspection of different thin wall materials itself as well as their joining methods.
Modern lightweight components are typically manufactured by a composition of different types of e.g. steels, metals, fiber reinforced plastics and glass. Dependent on the material combinations e.g. welding, brazing, bonding, cladding or coating may be applied during the manufacturing process to join different semi-finished products to form the component.
The resulting complex material composition and different damage mechanisms pose new challenges to non-destructive testing with ultrasound due to the different material properties and the overall arrangement of the materials employed.
The sound field variation capabilities of array probes may be helpful to overcome some of these challenges if adapted to the specific inspection task.
Examples for the non-destructive mechanized phased array inspection of different types of materials and joining methods will be presented.
Luftultraschall
(2020)
Air-coupled ultrasonic testing (ACUT) has experienced rapid growth within the last years. It is especially well suited to inspection of lightweight structures consisting of composite materials and adhesive joints. Uniform coupling and easy maintenance are its advantages compared to contact technique. However, the impedance mismatch between the transducer and air poses a major challenge to the development of ACUT transducers. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers. Their fabrication is difficult in handling and their signal-to-noise ratio sometimes not sufficient for various testing requirements. However, there are several innovative approaches using other materials and other physical principles to transmit and receive an ultrasonic pulse. We present a review of the latest advances in research on air-coupled transducers for non-destructive testing, including previously unpublished results. We recognize two major directions as most promising: ferroelectrets and thermoacoustic transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties. Their small acoustic impedance is matched to air better than matching layers applied in conventional air-coupled transducers. Applying bias voltage to a ferroelectret receiver is the latest development in this field, which increased the received signal by 12 to 15 dB. Thermoacoustic transducers use heat to initiate an ultrasonic wave, acting as transmitters. The working principle is known from nature as thunder and lightning: thermal energy of an electrically heated material, which can also be air, is converted into acoustic energy. Some thermoacoustic transmitters consist of a conductive layer with a thickness in the nanometer range deposited on a solid substrate. Another possibility is to use an electric spark. For the first time, measurements of the sound field of an electric spark up to 500 kHz were performed. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing.
Phased-Array-Prüfköpfe für luftgekoppelte Ultraschallprüfung auf Basis von zellulären Kunststoffen
(2023)
Luftgekoppelte Ultraschallprüfung setzt sich immer häufiger gegen die konventionelle Ultraschallprüfung von Leichtbaukomponenten durch, und zwar in vielen Industriezweigen von der Holzindustrie bis zur Luftfahrt. aWährend die Phased-Array-Technik mittlerweile zu dem industriellen Standard im Bereich der Prüfung mit Ankopplung gehört, wird luftgekoppelte Ultraschallprüfung meist mit zwei Wandlern in Durchschallung durchgeführt. Deswegen werden Vorteile der Phased-Array-Technik wie beispielsweise elektronische Fokussierung oder Schwenkung des Einschallwinkels für luftgekoppelte Prüfung selten genutzt.
In diesem Beitrag werden die laufenden Arbeiten an der Entwicklung eines neuen Phased-Array-Geräts vorgestellt, mit dem Schwerpunkt an der Charakterisierung der Prüfköpfe und ihrer Schallfelder. Das Gerät besteht aus einem linearen Phased-Array-Prüfkopf, einer Sende- und einer Empfangseinheit. Die Hauptinnovation unserer Arbeit ist die Anwendung von zellulären Kunststoffen für den Bau eines Arrays, wobei der Sender mit Hochspannung von ca. 1500 V angeregt wird. Geladene zelluläre Polymere werden auch Ferroelektrete oder Piezoelektrete genannt. Sie weisen einen sehr niedrigen Elastizitätsmodul und dadurch eine niedrige akustische Impedanz auf, so dass auf den Einbau von Anpassschichten verzichtet werden kann.
Eine sehr niedrige mechanische Kreuzkopplung bei Ferroelektreten ermöglicht eine unabhängige Anregung einzelner Elemente, was bei Piezokompositen deutlich schwieriger wäre. Die Entwicklung der Array-Prüfköpfe wurde durch Berechnungen des Schallfeldes unterstützt, die auf Punktquellensynthese basieren. Die beabsichtigte Anwendung von Phased-Array-Prüfköpfen und des Prüfsystems sind die Durchschallung mit Fokussierung, elektronischer Scan und die Schwenkung des Einschallwinkels zur Anregung von geführten Wellen, angewandt an carbonfaserverstärkten Kunststoffen und ähnlichen Materialien. Die Anwendung von geführten Wellen bietet die Perspektive, Bauteile mit einseitiger Zugänglichkeit zu prüfen.