Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (109)
- Vortrag (75)
- Posterpräsentation (23)
- Sonstiges (14)
- Beitrag zu einem Sammelband (10)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (1)
- Preprint (1)
- Forschungsbericht (1)
Schlagworte
- Synchrotron (52)
- XRF (45)
- BAMline (42)
- Gold (30)
- XANES (12)
- Synchrotron radiation (11)
- Archaeometry (9)
- BESSY (8)
- X-ray fluorescence (8)
- Machine learning (7)
Organisationseinheit der BAM
- 6 Materialchemie (55)
- 6.3 Strukturanalytik (55)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 8 Zerstörungsfreie Prüfung (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 5 Werkstofftechnik (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (75)
We report the results of an analytical investigation
on 416 silver-copper coins stemming from the Ottoman
Empire (end of 16th and beginning of 17th centuries), using
synchrotron micro X-ray fluorescence analysis (SRXRF).
In the past, analyses had already been conducted with energy
dispersive X-ray fluorescence analysis (EDXRF), scanning
electron microscopy with energy dispersive X-ray spectrometry
(SEM/EDX) and proton induced X-ray emission spectroscopy (PIXE).With this combination of techniques it was
possible to confirm the fineness of the coinage as well as to
study the provenance of the alloy used for the coins.
For the interpretation of the data statistical analysis
(principal component analysis—PCA) has been performed.
A definite local assignment was explored and significant
clustering was obtained regarding the minor and trace elements
composing the coin alloys.
The Color X-ray Camera CXC or SLcam® is an energy-resolving X-ray camera capable of energy- and space-resolved measurements. It consists of a high-speed CCD detector coupled to a polycapil-lary optic that conducts the X-ray photons from the probe to distinct pixels onto the detector. The camera is capable of fast acquisition of spatially and energy resolved fluorescence images. A dedicated software enables the acquisition and the online processing of the spectral data for all 69696 pixels, leading to a real-time visualization of the elements distribution in a sample. It was developed in a joint project with BAM, IFG Berlin and PN Sensors. In this contribution we will mainly discuss the use of the CXC at our beamline, the BAMline at BESSY II and imaging applications of the CXC from different areas, like biology and archaeometry. Additionally new developments for the use of the detector without optics, like wavelength dispersive detection or 1shot-XANES, will be presented.
The Color X-ray Camera CXC or SLcam® is an energy-resolving X-ray camera capable of energy- and space-resolved measurements. It consists of a high-speed CCD detector coupled to a polycapil-lary optic that conducts the X-ray photons from the probe to distinct pixels onto the detector.
The camera is capable of fast acquisition of spatially and energy resolved fluorescence images. A dedicated software enables the acquisition and the online processing of the spectral data for all 69696 pixels, leading to a real-time visualization of the elements distribution in a sample. It was developed in a joint project with BAM, IFG Berlin and PN Sensors.
In this contribution we will mainly discuss the use of the CXC at our beamline, the BAMline at BESSY II and imaging applications of the CXC from different areas, like biology and archaeometry. Additionally new developments for the use of the detector without optics, like wavelength dispersive detection or 1shot-XANES, will be presented.
Measurements of ion distributions at a charged solid–liquid interface using X-ray standing waves (XSW) are presented. High energy synchrotron radiation (17.48 keV) is used to produce an XSW pattern inside a thin water film on a silicon wafer. The liquid phase is an aqueous solution containing Br and Rb ions. The surface charge is adjusted by titration. Measurements are performed over a pH range from 2.2–9, using the native Si oxide layer and functional (amine) groups as surface charge. The Debye length, indicating the extension of the diffuse layer, could be measured with values varying between 1–4 nm. For functionalized wafers, the pH dependent change from attraction to repulsion of an ion species could be detected, indicating the isoelectric point. In combination with the measurement of the streaming current, the surface charge of the sample could be quantified.
The gold finds from Bernstorf, in the Freising district of Bavaria, were discovered in 1998, in the area of a Bronze Age settlement. First analyses with X-ray fluorescence (XRF) revealed gold of an unusually high purity grade, which was explained by using cementation techniques.
A newer analysis with laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) indicated an even higher purity. These analytical results were the starting point of an ongoing discussion. The amount and type of the detected contaminants were highly controversial and led to contradictory interpretations.
We reanalysed 11 gold samples with synchrotron radiation induced X-ray fluorescence (SRXRF) at the BAMline at BESSY-II. To reach the desired detection limits a thorough analysis with three different excitation energies and detection conditions were applied to confirm or disprove the previous results.
In this contribution we will get into the details for the need of the different measurement conditions and the virtues of the use of synchrotron radiation. The use and effectiveness of cementation techniques will be addressed. Finally we will present the achieved results and their impact on the discussion.
n this study, two green synthesis routes were used for the synthesis of Ag/ZnO nanoparticles, using cassava starch as a simple and low-cost effective fuel and Aloe vera as a reducing and stabilizing agent. The Ag/ZnO nanoparticles were characterized and used for bacterial dis-
infection of lake water contaminated with Escherichia coli (E. coli). Characterization indicated the formation of a face-centered cubic structure of metallic silver nanoparticles with no insertion of Ag into the ZnO hexagonal wurtzite structure. Physicochemical and bacteriological analyses described in “Standard Methods for the Examination of Water and Wastewater” were used to evaluate the efficiency of the treatment. In comparison to pure ZnO, the synthesized Ag/ZnO nanoparticles showed high efficiencies against Escherichia coli (E. coli) and general coliforms present in the lake
water. These pathogens were absent after treatment using Ag/ZnO nanoparticles. The results indicate that Ag/ZnO nanoparticles synthesized via green chemistry are a promising candidate for the treatment of wastewaters contaminated by bacteria, due to their facile preparation, low-cost synthesis,and disinfection efficiency.
The gold finds from Bernstorf, in the Freising district of Bavaria, were discovered in 1998, in the area of a Bronze Age settlement. First analyses with X-ray fluorescence (XRF) revealed gold of an unusually high purity grade, which was explained by the use of cementation techniques. A newer analysis with laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) indicated an even higher purity. The analytical results were the starting point of an ongoing discussion. In this study, we re-analysed 11 gold samples with Synchrotron radiation–induced X-ray fluorescence at the BAMline at BESSY. In a thorough analysis, different excitation and detection conditions were applied to confirm or disprove the previous results. It was shown that the purity of the gold from the specimen is higher than 99.9%. The main impurities are silver in a range between 20 and 200 μg/g and copper between 1 and 10 μg/g. The results are in very good agreement with the LA–ICP–MS measurements and provide basic information for discussions about provenance, processing techniques or considerations of authenticity.
In the quest for finding the ideal synchrotron-radiation-induced imaging method for the investigation of trace element distributions in human bone samples, experiments were performed using both a scanning confocal synchrotron radiation micro X-ray fluorescence (SR-mXRF) (FLUO beamline at ANKA) setup and a full-field color X-ray camera (BAMline at BESSY-II) setup. As zinc is a trace element of special interest in bone, the setups were optimized for its detection. The setups were compared with respect to count rate, required measurement time and spatial resolution. It was demonstrated that the ideal method depends on the element of interest. Although for Ca (a major constituent of the bone with a low energy of 3.69 keV for its K alpha XRF line) the color X-ray camera provided a higher resolution in the plane, for Zn (a trace element in bone) only the confocal SR-µXRF setup was able to sufficiently image the distribution.
Synchrotron radiation induced X-ray fluorescence for the characterization of ancient gold objects
(2009)
Several glazed ceramic fragments (XVIth to XVIIIth centuries) from two production centers in Portugal (Coimbra and Lisbon) were the object of this study. The ones from Coimbra comprise two sets of samples: faiences and tiles. The ones from Lisbon are only tiles (azulejos, in Portuguese). The three main divisions of such pieces are the ceramic support (body), glaze and surface decoration. The system decoration/glaze is not easy to investigate, due to the high heterogeneity resulting from the mixing procedures and firing temperatures used. Moreover, the ability of the pigment to diffuse into the base glaze varies depending on the composition of both the pigment and the glaze in terms of fusibility. In order to raster these effects, high resolution techniques are required. In this work, synchrotron micro-X-ray fluorescence (µ-XRF) analysis was performed to monitor the profiles of the characteristic elements from the colors used and the glaze in well prepared cross-sections of the samples. Key elements are: Co for blue, Mn for purple, Cu for green, Sb for yellow, Pb for the glaze and Fe for the body. The major difference observed is that faiences have glaze thicknesses between 150 and 200 µm and tiles have glaze thicknesses between 350 and 400 µm. Furthermore, in faiences all the pigments except the yellow ones are well dispersed into the glassy matrix, while in tiles, all of them are just partially diffused throughout the glaze. However, differences between the tiles from Coimbra and Lisbon were observed. In the samples from Lisbon, a higher intake from the pigment throughout the glaze is observed.