Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (109)
- Vortrag (75)
- Posterpräsentation (23)
- Sonstiges (14)
- Beitrag zu einem Sammelband (10)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (1)
- Preprint (1)
- Forschungsbericht (1)
Schlagworte
- Synchrotron (52)
- XRF (45)
- BAMline (42)
- Gold (30)
- XANES (12)
- Synchrotron radiation (11)
- Archaeometry (9)
- BESSY (8)
- X-ray fluorescence (8)
- Machine learning (7)
Organisationseinheit der BAM
- 6 Materialchemie (55)
- 6.3 Strukturanalytik (55)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 8 Zerstörungsfreie Prüfung (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 5 Werkstofftechnik (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (75)
With increasing demand and environmental concerns, researchers are exploring new materials that can perform as well or better than traditional materials while reducing environmental impact. The BAMline, a real-life sample materials research beamline, provides unique insights into materials’ electronic and chemical structure at different time and length scales. The beamline specializes in x-ray absorption spectroscopy, x-ray fluorescence spectroscopy, and tomography experiments. This enables real-time optimization of material properties and performance for various applications, such as energy transfer, energy storage, catalysis, and corrosion resistance. This paper gives an overview of the analytical methods and sample environments of the BAMline, which cover non-destructive testing experiments in materials science, chemistry, biology, medicine, and cultural heritage. We also present our own synthesis methods, processes, and equipment developed specifically for the BAMline, and we give examples of synthesized materials and their potential applications. Finally, this article discusses the future perspectives of the BAMline and its potential for further advances in sustainable materials research.
Synchrotron radiation X-ray fluorescence spectroscopy, in conjunction with atomic absorption and Raman spectroscopy, was used to analyze a set of top brand tattoo inks to investigate the presence of toxic elements and hazardous substances. The Cr, Cu, and Pb contents were found to be above the maximum allowed levels established by the Council of Europe through the resolution ResAP(2008)1 on requirements and criteria for the safety of tattoos and permanent makeup. Raman analysis has revealed the presence of a set of prohibited substances mentioned in ResAP(2008)1, among which are the pigments Blue 15, Green 7, and Violet 23. Other pigments that were identified in white, black, red, and yellow inks are the Pigment White 6, Carbon Black, Pigment Red 8, and a diazo yellow, respectively. The present results show the importance of regulating tattoo ink composition.
Various applications for artificial intelligence in the context of spectroscopy will be presented. in particular, examples from bamline will be featured. After a short introduction to synchrotron radiation, artificial intelligence algorithms for the quantification of X-ray fluorescence measurement are discussed. In the second example, information retrieval by natural language processing is reviewed. As a last example the reconstruction of measurements with the X-ray color camera and coded apertures is presented.
Ein Konvolut einzelner Schmuckstücke und die Goldbeigaben eines angeblichen Grabfundes wurden technologisch und analytisch untersucht. Die meisten Objekte sind Blecharbeiten, die aus einer Vielzahl von Einzelteilen mit metallischem Goldlot zusammengefügt und mit Granulation oder granulations-imitierendem Perl- oder Kerbdraht verziert wurden. Nur vier kleine Ohrringe sind massiv gegossen.
Zwei Zierbleche dürften über Patrizen (Positivmodeln), die Deckel der Astragale in Matrizen (Negativmodeln) geformt worden sein. Alle Objekte wurden mit Synchrotron- und atmosphärischer Röntgenfluoreszenz analysiert. Die Daten zeigen das breite Spektrum an Goldlegierungen, die im 7./6. Jahrhundert v. Chr. in Kleinasien verarbeitet wurden: vom natürlichen Seifengold (Elektrum) bis zu geläutertem, fast reinem Gold. Eine Korrelation zwischen Goldqualität und Verarbeitungsmethode konnte nicht festgestellt werden. Sowohl hochreines als auch mit viel Silber und Kupfer legiertes Gold wurde zum Schmieden von Blecharbeiten, aber auch zum Massivguss verwendet. Aus der Goldfarbe kann wegen des Phänomens der oberflächlichen Goldanreicherung nicht auf eine Legierungszusammensetzung geschlossen werden. Der 1963 angekaufte Fundkomplex aus lydischen Metallarbeiten und ostionischen Salbgefäßen aus Ton dürfte einen Grabfund des frühen 6. Jahrhunderts v. Chr. darstellen, dessen Herkunft aus Ephesos jedoch nicht zu sichern ist.
The structure and composition of ancient gold objects retain information about their long history of manufacture, from the exploitation of the ore to the finishing touches, as well as evidence of their use, deposition, and degradation. By developing an efficient analytical strategy, it is possible to retrieve that information. This chapter sets the necessary foundation 131to explore fully the analytical results presented in the following chapters of this volume. The techniques employed in the analyses of the Egyptian jewellery are described and the analytical parameters provided. For more established techniques, only brief introductions are presented, while more recent developments are presented in greater detail.
Measuring in a non-destructive way the characteristic trace elements of the metal allows following the circulation of gold in the past. The aim of this work is to probe the possibilities of X-ray fluorescence with high energy synchrotron radiation (SR-XRF) at the BAMline at BESSY II to determine the concentration of Pt in ancient gold alloys. A HP-Ge detector was used to measure the Pt K-lines excited with an incident energy of 79.5 keV. Data processing was done by subtraction of a Pt free gold standard spectrum from the spectrum of the sample. Depending on the sample composition, the MDL ranges between 40 and 90 ppm. The first results obtained for a small set of gold alloys of different thickness, size and composition showed that high energy SR-XRF is a significant method for the non-destructive determination of Pt in gold.
Four hundred and sixteen silver coins stemming from the Ottoman Empire (16th and 17th centuries) were analyzed to confirm the fineness of the coinage as well as to study the provenance of the alloy used for the coins. As most of the coins showed the typical green patina on their surfaces due to corrosion processes that have led to the depletion of copper in the near surface domains of the silver coins in comparison to their core composition, small samples had to be taken, embedded in synthetic resin, and cross sectioned to investigate the true-heart metal composition. µ-synchrotron micro X-ray fluorescence analysis and µ-proton-induced X-ray emission were applied to determine the silver contents as well as the minor and trace elements. The type of the alloy was investigated as well as if coins minted in different locations demonstrated homogeneous traits concerning the predominant impurities (Au and Bi), which could suggest a common ore. Finally, energy-dispersive microanalysis in a scanning electron microscope was applied to study the homogeneity/heterogeneity of the coins and the presence of surface enrichments and to explain differences between the µ-synchrotron micro X-ray fluorescence analysis and µ-proton-induced X-ray emission measurements concerning the main component. In general, the silver content of the analyzed specimen varies between 90 and 95%. These outcomes have not supported the historical interpretations, which predict that during the period studied, a debasement of approximately 44% of the silver content of the coins should have occurred.
Pilot studies have been carried out at the BAMline at BESSY II in collaboration with the Bundesanstalt
für Materialforschung und -prüfung (BAM) on metal- and metalloid-containing compounds in biological
samples after electrophoretic protein separation. After sodium dodecylsulfate polyacrylamide gel
electrophoresis (SDS-PAGE) and transfer onto a blotting membrane the distribution of selenium among
the proteins of testis homogenate of a rat and a wallaby was determined. The comparison with the
autoradiogram of 75Se-labeled proteins separated in the same way showed that of nine seleniumcontaining
proteins found in rat testis homogenate by autoradiography four could be detected by
synchrotron radiation X-ray fluorescence analysis (SRXRF).
Increasing numbers of implant revisions are a current clinical issue. Interactions of the endoprosthesis biomaterial with the body affect implantation time by wear processes, i.e. corrosion and abrasion. Previously, cobalt-chrome implants were shown to cause high levels of cobalt ions being deposited in the bone matrix. To determine a poten- tial functional role of these ions on bone homeostasis, we have developed a non-destructive dual analysis of highly sensitive elemental analysis by synchrotron XRF directly in undecalcified histological bone thin sections (4 μm). In this study, samples from 28 bone samples from hip endoprosthesis carriers (Surface Replacement Arthroplasty, metal-on-metal bearing) with an implant lifetime of 17–1750 days were used. Results were compared to age- matched control specimens. The histological analysis identified areas of bone cell activity and assigned them for XRF measurements. Co-Cr wear particles were identified in the bone marrow. In addition, Co ions were highly enriched in the mineralized bone matrix. The cobalt deposits were not homogeneously distributed, and areas of high signal intensity were identified. Co was distinctly deposited in the newly formed osteoid layer, but also within deeper layers of the bone matrix, whereby the Co concentration increased with higher degrees of bone matrix mineralization. In the current study, we determined cobalt accumulations in the bone matrix and showed for the first time via synchrotron XRF with a high spatial resolution direct on histological slides, that cobalt deposits in the mineralized bone matrix in a mineral-specific way that is dependent upon the implant lifetime.
Adaptive Kanalreduktion eines hyperspektralen Bilddatensatzes kombiniert mit k-mean Clustering
(2014)
Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA.