Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (109)
- Vortrag (75)
- Posterpräsentation (23)
- Sonstiges (14)
- Beitrag zu einem Sammelband (10)
- Beitrag zu einem Tagungsband (7)
- Buchkapitel (1)
- Preprint (1)
- Forschungsbericht (1)
Schlagworte
- Synchrotron (52)
- XRF (45)
- BAMline (42)
- Gold (30)
- XANES (12)
- Synchrotron radiation (11)
- Archaeometry (9)
- BESSY (8)
- X-ray fluorescence (8)
- Machine learning (7)
Organisationseinheit der BAM
- 6 Materialchemie (55)
- 6.3 Strukturanalytik (55)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 8 Zerstörungsfreie Prüfung (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 5 Werkstofftechnik (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (75)
Compact pnCCD-based X-ray camera with high spatial and energy resolution: a color X-ray camera
(2011)
For many applications there is a requirement for nondestructive analytical investigation of the elemental distribution in a sample. With the improvement of X-ray optics and spectroscopic X-ray imagers, full field X-ray fluorescence (FF-XRF) methods are feasible. A new device for high-resolution X-ray imaging, an energy and spatial resolving X-ray camera, is presented. The basic idea behind this so-called 'color X-ray camera' (CXC) is to combine an energy dispersive array detector for X-rays, in this case a pnCCD, with polycapillary optics. Imaging is achieved using multiframe recording of the energy and the point of impact of single photons. The camera was tested using a laboratory 30 µm microfocus X-ray tube and synchrotron radiation from BESSY II at the BAMline facility. These experiments demonstrate the suitability of the camera for X-ray fluorescence analytics. The camera simultaneously records 69696 spectra with an energy resolution of 152 eV for manganese Kα with a spatial resolution of 50 µm over an imaging area of 12.7 × 12.7 mm². It is sensitive to photons in the energy region between 3 and 40 keV, limited by a 50 µm beryllium window, and the sensitive thickness of 450 µm of the chip. Online preview of the sample is possible as the software updates the sums of the counts for certain energy channel ranges during the measurement and displays 2-D false-color maps as well as spectra of selected regions. The complete data cube of 264 × 264 spectra is saved for further qualitative and quantitative processing.
Naturwissenschaftliche Informationen, insbesondere die chemische Zusammensetzung der Objekte, können Hinweise auf die Hintergründe der Objektherstellung liefern, die der alleinigen kunsthistorischen Begutachtung verborgen blieben. Es können nicht nur Fragen nach dem Prozess, Zeitpunkt und Ort der Herstellung beantwortet werden. Die chemische Analyse gibt auch Hinweise auf Ereignisse und Veränderungen, die erst nach der Fertigstellung des Objektes erfolgten. So werden Alterungsphänomene oder historische Überarbeitungen und Restaurierungen aufgedeckt, aber auch Konservierungsstrategien zur Erhaltung der Kunstwerke unterstützt. Durch den technologischen Fortschritt im Bereich der röntgenanalytischen Methoden, die berührungsfrei, ohne Probennahme und ohne Schädigung für das Untersuchungsobjekt arbeiten, erschließen sich dem Analytiker erstmalig Möglichkeiten, auch sehr wertvolle und fragile Objekte zerstörungsfrei zu untersuchen.
Chemical state of chromium, sulfur, and iron in sewage sludge ash based phosphorus fertilizers
(2015)
As an essential element of all life forms, phosphorus (P) is vital to the fertilizer industry. With decreasing quantity and quality of phosphate rock resources, recycling P-fertilizers from wastewater is of increasing interest. The P-fertilizer products of a recently developed thermochemical process for P recovery from sewage sludge ash (SSA) were investigated by chromium, sulfur, and iron K-edge X-ray near-edge structure (XANES) spectroscopy. This paper focuses the formation and prevention of toxic chromium(VI) and toxic sulfides during the thermochemical processes. Reducing conditions prevent the oxidation of chromium(III) in the SSA to toxic chromium(VI). Sulfides formed under the reducing conditions are nontoxic iron sulfides. Hematite (Fe2O3) present in the SSA is reduced to magnetite (Fe3O4). A gentle post-treatment at 400 °C under oxidizing conditions converts the iron sulfides into plant-available iron sulfates. This oxidative post-treatment does not form undesired chromium(VI) compounds.
Four hundred sixteen silver coins stemming from the Ottoman Empire (16th and 17th centuries) were analyzed in order to confirm the fineness of the coinage as well as to study the provenance of the alloy used for the coins. As most of the coins showed the typical green patina on their surfaces due to corrosion processes which have led to the depletion of copper in the near-surface domains of the silver coins in comparison to their core composition, small samples by cutting splinters from the coins had to be taken, embedded in synthetic resin and cross-sectioned in order to investigate the true-heart metal composition. The type of the alloy was investigated as well as if coins minted in different locations demonstrated homogeneous traits concerning the predominant impurities which could suggest a common ore. Several X-ray based techniques (µ-XRF, µ-SRXRF and µ-PIXE) could be applied in order to determine the silver contents as well as the minor and trace elements. Finally, SEM/EDX was applied in order to study the homogeneity/heterogeneity of the coins and the presence of surface enrichments. In general, the silver content of the analyzed specimen varies between 90% and 95%. These outcomes have not supported the historical interpretations, which predict that during the period studied a debasement of approximately 44% of the silver content of the coins should have occurred.
A core component of energy storage systems like vanadium redox flow batteries (VRFB) is the polymer electrolyte membrane (PEM). In this work, the frequently used perfluorosulfonic-acid (PFSA) membrane Nafion™ 117 and a novel poly (vinylidene difluoride) (PVDF)-based Membrane are investigated. A well-known problem in VRFBs is the vanadium permeation through the membrane. The consequence of this so-called vanadium crossover is a severe loss of capacity. For a
better understanding of vanadium transport in membranes, the uptake of vanadium ions from electrolytes containing Vdimer(IV–V) and for comparison also V(II), V(III), V(IV), and V(V) by both membranes was studied. UV/VIS spectroscopy, X-ray absorption near edge structure spectroscopy (XANES), total reflection X-ray fluorescence spectroscopy (TXRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and micro X-ray fluorescence spectroscopy (microXRF) were used to determine the vanadium concentrations and the species inside the membrane. The results strongly support that Vdimer(IV–V), a dimer formed from V(IV) and V(V), enters the nanoscopic water-body of Nafion™ 117 as such. This is interesting, because as of now, only the individual ions V(IV) and V(V) were considered to be transported through the membrane. Additionally, it was found that the Vdimer(IV–V) dimer partly dissociates to the individual ions in the novel PVDF-based membrane.
The Vdimer(IV–V) dimer concentration in Nafion™ was determined and compared to those of the other species. After three days of equilibration time, the concentration of the dimer is the lowest compared to the monomeric vanadium species. The concentration of vanadium in terms of the relative uptake λ = n(V)/n(SO3
) are as follows: V(II) [λ = 0.155] > V(III) [λ = 0.137] > V(IV) [λ = 0.124] > V(V) [λ = 0.053] > Vdimer(IV–V) [λ = 0.039]. The results show that the Vdimer(IV–V) dimer Needs to be considered in addition to the other monomeric species to properly describe the transport of vanadium through Nafion™ in VRFBs.
This Report describes the certification of the reference material antimony implanted in Si/SiO2 intended to be used for calibration of surface and near surface analytical methods. It describes the preparation, homogeneity measurements and the analytical work performed for the certification of both Areal density of antimony Atoms (retained dose) and the isotope amount Ratio as well as giving considerations on the stability of the material.
Bundling analytical capacities to understand phase formation in recycling of functional materials
(2019)
Transitioning from combustion engine-driven transportation to e-mobility demands a paradigm shift – from a system geared to maximize energy efficiency (i.e. fuel consumption) to a system that may be constrained by the availability of high technology (critical) metals required for electrical energy storage systems and drives. In the wake of these developments efforts in securing new resources of these metals from recycling of end-of-life products are increasing steadily.
Recycling of Li-Ion batteries has recently been evaluated. The results pinpoint to a critical need for understanding slag Formation and its dependence on metal components like Mn under extreme conditions. This will allow researchers to predict optimal Operation setting and to react quickly to changing market demands (which may be Li or Co at one point but may also shift to Ni or rare earth elements (REE)). The long-term goal is to control the formation of specific phases in slags allowing for a Maximum yield of elements of interest and optimal recovery in the separation processes that follows. The combination of data on the physical micro structure and local chemistry of the multi-Phase products during and after processing will help to understand and derive thermodynamic and kinetic data on its formation.
In this paper we are giving an overview on the analytical challenges and approaches to provide robust data on local element concentration and species (especially Mn which is a common component of next generation Li-ion batteries cathodes), spanning the dimensions from the nanometer scale to the bulk material. The complementary interactions of X-rays and electrons make them ideal probes to collect Interface and “in-depth” information. Before- and -after studies as well as in situ structural changes and Phase (trans)formation, changes in elemental and elemental species (e.g. oxidation state) distribution may be tracked by X-ray diffraction (XRD), X-ray fluorescence microscopy and X-ray Absorption spectroscopy. The application of such advanced analytical tools will not only provide essential clues during early lab-based experiments towards the development of new recycling technologies, but may also be deployed for on-line and in-line monitoring of industrial processes.
In this talk an overview about artificial intelligence/machine learning applications @BAMline is given. In the first part, the use of neural networks for the quantification of XRF measurements and the decoding of coded-aperture measurements are shown. Then it is shown how Gaussian processes and Bayesian statistics can be used to achieve an optimal alignment of the set-up and in general for optimization of measurements.
Fingerprinting ancient gold work requires the use of nondestructive techniques with high spatial resolution (down to 25 µm) and good detection limits (micrograms per gram level). In this work experimental setups and protocols for synchrotron radiation induced X-ray fluorescence (SRXRF) at the BAMline of the Berlin electron storage ring company for synchrotron radiation (BESSY) in Berlin for the measurement of characteristic trace elements of gold are compared considering the difficulties, shown in previous works, connected to the quantification of Pt. The best experimental conditions and calculation methods were achieved by using an excitation energy of 11.58 keV, a silicon drift chamber detector (SDD) detector, and pure element reference standards. A detection limit of 3 µg/g has been reached. This newly developed method was successfully applied to provenancing the Xiongnu gold from the Gol Mod necropolis, excavated under the aegis of the United Nations Educational, Scientific and Cultural Organization (UNESCO). The composition of the base alloys and the presence of Pt and Sn showed that, contrary to what is expected, the gold foils from the first powerful empire of the steppes along the Great Wall were produced with alluvial gold from local placer deposits located in Zaamar, Boroo, and in the Selenga River.