Absorption effects in total reflection X-ray fluorescence (TXRF) analysis are important to consider, especially if external calibration is to be applied. With a color X-ray camera (CXC), that enables spatially and energy resolved XRF analysis, the absorption of the primary beam was directly visualized for mL-droplets and an array of pL-droplets printed on a Si-wafer with drop-on-demand technology. As expected, deposits that are hit by the primary beam first shade subsequent droplets, leading to a diminished XRF signal. This shading effect was quantified with enhanced precision making use of sub-pixel analysis that improves the spatial resolution of the camera. The measured absorption was compared to simulated results using three different model calculations. It was found they match very well (average deviation < 10%). Thus errors in quantification due to absorption effects can be accounted for in a more accurate manner.
Chemical state of chromium, sulfur, and iron in sewage sludge ash based phosphorus fertilizers
(2015)
As an essential element of all life forms, phosphorus (P) is vital to the fertilizer industry. With decreasing quantity and quality of phosphate rock resources, recycling P-fertilizers from wastewater is of increasing interest. The P-fertilizer products of a recently developed thermochemical process for P recovery from sewage sludge ash (SSA) were investigated by chromium, sulfur, and iron K-edge X-ray near-edge structure (XANES) spectroscopy. This paper focuses the formation and prevention of toxic chromium(VI) and toxic sulfides during the thermochemical processes. Reducing conditions prevent the oxidation of chromium(III) in the SSA to toxic chromium(VI). Sulfides formed under the reducing conditions are nontoxic iron sulfides. Hematite (Fe2O3) present in the SSA is reduced to magnetite (Fe3O4). A gentle post-treatment at 400 °C under oxidizing conditions converts the iron sulfides into plant-available iron sulfates. This oxidative post-treatment does not form undesired chromium(VI) compounds.
Examples of XRF and PIXE imaging with few microns resolution using SLcam® a color X-ray camera
(2015)
We present results of recent development of the color X-ray camera, type SLcam®, allowing detection of X-ray images with few microns resolution. Such spectral resolution is achieved with the use of high-quality polycapillary optics combined with sub-pixel resolution. Imaging of Siemens star resolution test chart reveals that the resolution limit of SLcam® can go down to nearly 5µm. Several real sample examples of measurements carried out at the laboratory, synchrotron, and particle-induced X-ray emission beamlines are shown. This is the first time SLcam® is used as particle-induced X-ray emission detector.
Recent results from a three-year multi-disciplinary project on Ancient Egyptian gold jewellery revealed that items of jewellery from the Middle Kingdom to the New Kingdom were manufactured using a variety of alluvial gold alloys. These alloys cover a wide range of colours and the majority contain Platinum Group Elements inclusions. However, in all the gold foils analysed, these inclusions were found to be absent. In this work a selection of gilded wood and leather items and gold foil fragments, all from the excavations by John Garstang at Abydos (primarily from Middle Kingdom graves), were examined using Scanning Electron Microscopy-Energy Disperse Spectroscopy (SEM-EDS), X-Ray Fluorescence (µXRF), Particle Induced X-Ray Emission (µPIXE) and Double Dispersive X-Ray Fluorescence (D²XRF). The work allowed us to characterise the composition of the base-alloys and also to reveal the presence of Pt at trace levels, confirming the use of alluvial gold deposits. Corrosion products were also investigated in the foils where surface tarnish was visually observed. Results showed that the differences in the colour of corrosion observed for the foils are related not only to the thickness of the corrosion layer but also to a multi-layer structure containing the various corrosion products.
This work presents a complex evaluation of a series of Geto-Thracian silver adornments found on Romanian territory, part of the 4th century BC Agighiol (Northern Dobruja) hoard and of an ingot from the 1st century BC Geto-Dacian Surcea (Transylvania) hoard, using Synchrotron Radiation X-Ray Fluorescence and micro- Proton Induced X-ray Emission analysis and mapping in order to investigate aspects related to the elemental composition of the metal and the metallurgy implied in their manufacture. One of the samples can be linked to Laurion as the source of metal, and several items contain silver probably originated in Macedonia. The set of silver items was found to be heteregenous as composition and microstructure, and corrosion-related elements could be also identified in the X-Ray maps.
The color X-ray camera SLcam® is a full-field, single photon detector providing scanning-free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a charged-coupled device detector. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Therefore, the SLcam® spatial resolution, which is normally limited to the pixel size of the charge-coupled device, can be improved to the size of individual polycapillary channels. In this work a new approach to a sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed.
The reaction of iron chlorides with an alkaline reagent is one of the most prominent methods for the synthesis of iron oxide nanoparticles. We studied the particle formation mechanism using triethanolamine as reactant and stabilizing agent. In situ fast-X-ray absorption near edge spectroscopy and small-angle X-ray scattering provide information on the oxidation state and the structural information at the same time. In situ data were complemented by ex situ transmission electron microscopy, wide-angle X-ray scattering and Raman analysis of the formed nanoparticles. The formation of maghemite nanoparticles (γ-Fe2O3) from ferric and ferrous chloride was investigated. Prior to the formation of these nanoparticles, the formation and conversion of intermediate phases (akaganeite, iron(II, III) hydroxides) was observed which undergoes a morphological and structural collapse. The thus formed small magnetite nanoparticles (Fe3O4) grow further and convert to maghemite with increasing reaction time.