Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (39)
- Zeitschriftenartikel (25)
- Vortrag (18)
- Posterpräsentation (4)
- Beitrag zu einem Sammelband (2)
- Amtliche Bekanntmachung (2)
- Dissertation (1)
Sprache
- Englisch (65)
- Deutsch (25)
- Mehrsprachig (1)
Schlagworte
- Radioactive material (15)
- Impact limiter (13)
- Transport (13)
- Wood (11)
- FEM (7)
- Behälterversagen (6)
- Package (6)
- Consequences (4)
- Drop test (4)
- Explosion (4)
Organisationseinheit der BAM
- 3 Gefahrgutumschließungen; Energiespeicher (25)
- 3.3 Sicherheit von Transportbehältern (23)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 8 Zerstörungsfreie Prüfung (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 9 Komponentensicherheit (4)
- 9.5 Tribologie und Verschleißschutz (4)
- 2.2 Prozesssimulation (2)
- 3.0 Abteilungsleitung und andere (2)
Eingeladener Vortrag
- nein (18)
Im Rahmen des Projekts „Complex Fires – Auswirkung von Behälterversagen“ (CoFi-ABV) sollen die Auswirkungen des Versagens von Gasbehältern für alternative Treibstoffe in Fahrzeugen unter Berücksichtigung komplexer Brand- und Explosionsszenarien untersucht werden. Es wird der aktuelle Hintergrund des Forschungsvorhabens erläutert sowie die geplanten Untersuchungen und beabsichtigten Ergebnisse vorgestellt. Hauptbestandteil des Projekts ist eine Vielzahl von zerstörenden Großversuchen. Im Vorfeld dieser Großversuche werden zur Weiterentwicklung und Adaptierung von Messtechnik Versuche im kleineren Maßstab durchgeführt. Im Folgenden werden Teile dieser Ver-suchsaufbauten im „mid-scale“ sowie die dabei verwendete Messtechnik dargestellt. Weiterhin werden erste Ergebnisse aus Wärmeeintragsversuchen zur Quantifizierung verschiedener Unterfeuerungsmethoden für die zerstörenden Großversuche vorgestellt.
Commercial, off-the shelf propane cylinders are subjected to high safety regulations. Furthermore, those cylinders are equipped with safety devices like pressure relief valves (PRV). Despite these regulations and safety measures, a failure of the Container is possible if exposed to an intense fire. The result of this is severe hazard for users, rescue forces and infrastructure. Within the framework of a destructive test series, 15 identical propane cylinders, without pressure relief devices, were exposed to an intensive fire in horizontal Position until failure. Each cylinder was filled with a mass of m =11 kg of liquid propane. Three different fire sources were used (wood, petrol, propane). The experiments revealed the failure of all cylinders in a time period t < 155 s. The failure lead to a fragmentation into several major parts with throwing distances of up to l =262 m. In all trials, the temperature of the cylinder wall (top, side, bottom), of the liquid phase inside and of the surrounding fire (top, side, bottom) was recorded. In addition, the inner cylinder pressure and the induced overpressure of the blast wave after the failure were recorded. Overpressures of up to p=0.27 bar were recorded close to the cylinder (l =5 m). AM tests were documented hy video from several positions (general view, close-up, high-speed 5000 fps). This test series creates the basis for further experimental studies in the field of alternative fuels for vehicles. The aim of this test series is to assess and analyse the consequences of the failure of gas vessels (for LPG, CNG, CGH2) in the aftermath of severe incidents.
Commercial, off-the shelf propane cylinders are subjected to high safety regulations. Furthermore, those cylinders are equipped with safety devices like pressure relief valves (PRV). Despite these regulations and safety measures, a failure of the container is possible if exposed to an intense fire. The result of this is severe hazard for users, rescue forces and infrastructure. Within the framework of a destructive test series, 15 identical propane cylinders, without pressure relief devices, were exposed to an intensive fire in horizontal position until failure. Each cylinder was filled with a mass of m =11 kg of liquid propane. Three different fire sources were used (wood, petrol, propane). The experiments revealed the failure of all cylinders in a time period t < 155 s. The failure lead to a fragmentation into several major parts with throwing distances of up to l =262 m. In all trials, the temperature of the cylinder wall (top, side, bottom), of the liquid phase inside and of the surrounding fire (top, side, bottom) was recorded. In addition, the inner cylinder pressure and the induced overpressure of the blast wave after the failure were recorded. Overpressures of up to p=0.27 bar were recorded close to the cylinder (l =5 m). All tests were documented by video from several positions (general view, close-up, high-speed 5000 fps). This test series creates the basis for further experimental studies in the field of alternative fuels for vehicles. The aim of this test series is to assess and analyse the consequences of the failure of gas vessels (for LPG, CNG, CGH2) in the aftermath of severe incidents.
In Deutschland gibt es eine große Anzahl von Kraftfahrzeugen, die mit alternativen Antrieben (z. B. LPG (Liquefied Petroleum Gas), CNG (Compressed Natural Gas)) ausgerüstet sind. In zahlreichen Großversuchsserien untersucht die Bundesanstalt für Materialforschung und -prüfung (BAM) im Rahmen des internen Forschungsprojekts CoFi-ABV (Complex Fires – Auswirkungen von Behälterversagen) die Auswirkungen beim Versagen der Treibstoffbehälter dieser alternativen Antriebe. Ziel dieser Untersuchungen ist eine ganzheitliche Auswirkungsbetrachtung, um die Risiken für Feuerwehren und Rettungskräfte besser abschätzen zu können. Im Vorfeld zu den Versuchen für LPG- und CNG-Tanks wurden in einer weiteren Versuchsserie 15handelsübliche 11-kg-Propangasflaschen ohne Sicherheitseinrichtung unterfeuert. Alle 15 Behälter haben – wie zu erwarten war – versagt. Neben den Zustandsdaten des Behälters zum Versagenszeitpunkt (Temperatur des Behältermantels, Innendruck und -temperatur) wurden die Auswirkungen auf die Umgebung hinsichtlich Druckwirkung und Fragmentierung (Anzahl, Masse, Distanz, Richtung) dokumentiert.
In einer Großversuchsserie wurden auf dem BAM-TTS 15 11-kg-Propangasflaschen ohne Sicherheitseinrichtung mit drei verschiedenen Methoden (Holz, Benzinpool, Gas) unterfeuert. Der Beitrag beschreibt die dokumentierten Auswirkungen (z. B. Fragmentierung, Überdruck), die Art des Versagens sowie den Behälterzustand zum Zeitpunkt des Versagens.
In case of a vehicle fire, an installed LPG (liquefied petroleum gas) tank with a malfunctioning safety device poses severe hazards. To investigate the consequences in case of tank failure, we conducted 16 tests with toroidal shaped LPG vehicle tanks. Three tanks were used for a Hydraulic Burst Test under standard conditions. Another three tanks were equipped with a statutory safety device and were subjected to a gasoline pool fire. The safety device prevented tank failure, as intended. To generate a statistically valid dataset on tank failure, ten tanks without safety devices were exposed to a gasoline pool fire. Five tanks were filled to a level of 20 %; the re-maining five were filled to a level of 100 %. In order to gain information on the heating process, three tem-perature readings at the tank surface, and three nearby flame temperatures were recorded. At distances of l = (7; 9; 11) m to the tank, the overpressure of the shock wave induced by the tank failure and the unsteady tem-peratures were measured. All ten tanks failed within a time of t < 5 min in a BLEVE (boiling liquid expanding vapor explosion). Seven of these resulted directly in a catastrophic failure. The other three resulted in partial failure followed by catastrophic failure. A near field overpressure at a distance of l = 7 m of up to p = 0.27 bar was measured. All ten tests showed massive fragmentation of the tank mantle. In total, 50 fragments were found. These 50 fragments make-up 88.6 % of the original tank mass. Each fragment was georeferenced and weighed. Fragment throwing distances of l > 250 m occurred. For the tanks with a fill level of 20 %, the average number of fragments was twice as high as it was for the tanks that were filled completely.
Compressed natural gas (CNG) is a widely used automotive fuel in a variety of countries. In case of a vehicle fire where the safety device also malfunctions, a failure of the CNG automotive cylinder could occur. Such a cylinder failure is associated with severe hazards for the surrounding environment. Firstly, a comprehensive analysis is given below, summarizing various accidents involving CNG automotive cylinders and their consequences. In an extensive experimental program, 21 CNG automotive cylinders with no safety device were tested. Of the 21, burst tests were carried out on 5 Type III and 5 Type IV cylinders. Furthermore, fire tests with 8 Type III and 3 Type IV cylinders were conducted. Apart from cylinder pressure, inner temperature and cylinder mantle temperature, the periphery consequences, such as nearfield blast pressure and fragmentation are documented. The maximum measured overpressure due to a Type III cylinder failure was p = 0.41 bar. Each traceable fragment was georeferenced. All-in-all, fragment throw distances of d > 300 m could be observed. As one key result, it can be stated that the tested Type IV CNG cylinders showed less critical failure behavior then the Type III cylinders under fire impingement.
With integration of the new para 613A into SSR-6 [1] the consideration of ageing mechanisms is now obligatory for the design of packages and their approval. In addition, para 809(f) of SSR-6 [1] requires consideration of the effects of storage on ageing mechanisms, safety analyses and operation and maintenance instructions.
German competent authorities Bundesanstalt für Materialforschung und -prüfung (BAM) and Bundesamt für die Sicherheit der nuklearen Entsorgung (BASE) are considering the aspect of ageing in approval procedures. Ageing assessment is mainly focused on dual purpose casks (DPC) package designs which are long-term stored in interim storage facilities. For these package designs, the evaluation of ageing management is now mandatory for the maintenance of the package design approvals with a validity period of 5 years and beyond. The ageing management includes amongst others a gap analysis, the assessment of ageing effects and operational experiences during operation and interim storage.
BAM works on the compilation of a guideline for implementation of paras 613A, 809(f) and 809(k) for packages requiring competent authority approval at the application procedure in Germany. The paper describes essential items of ageing mechanisms and will give a foresight to the ageing management evaluation by BAM.
The consideration of ageing mechanisms is with integration of the new para 613A into IAEA SSR-6 (Rev. 1) now obligatory for the design of transport packages. In addition, para 809(f) requires for packages intended to be used for shipment after storage the consideration of the effects of ageing mechanisms during storage in safety analyses and the implementation of corresponding instructions for operation and maintenance. Para 503(e) requires that all packaging components and radioactive contents have been maintained during storage in a manner that all requirements specified in IAEA SSR-6 (Rev.1) and in the applicable certificates of approval have been fulfilled.
The evaluation of ageing mechanisms and their effects including monitoring are part of BAM’s authority assessment tasks related to the mechanical and thermal package design and quality assurance aspects. BAM has compiled a guideline for the implementation of ageing assessment and of the measures for ageing management of the approval procedure based on requirements of IAEA SSR-6 (Rev.1). The guideline is applicable only for packages requiring a competent authority approval.
The paper aims to describe the structure of the guideline and the general approach for ageing management requirements. The type and amount of measures for ageing management depend mainly on the use of the package and on the ageing effects for the component, which result from relevant ageing mechanisms during package operation time.
The implementation of measures for ageing management is divided into three levels – systemic measures, package design related measures and documentation. The systemic measures are attributed to the general management system and define the whole activities for organization of ageing management like structure, responsibilities, documentation, reports and evaluation. The package design related measures are defined in an ageing management plan (AMP). These measures shall ensure that the anticipated changes of the package design under consideration of ageing effects still complies with the design approval specification. Therefore, an ageing surveillance program (ASP) and, if necessary, a gap analysis program shall be developed. The ageing management documentation (AMD) ensures the continuous documentation of the compliance of a specific package to the approved package design, comprising mainly records resulting from operation and surveillance.