Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (51)
- Deutsch (7)
- Mongolisch (1)
Schlagworte
- Lab-on-a-chip (6)
- SAFT (4)
- BAMline (3)
- Biosensor (3)
- Electromagnetic testing (3)
- Finite element method (3)
- Microfluidics (3)
- Ring resonator (3)
- Spherical defects (3)
- XRF (3)
Organisationseinheit der BAM
Scanning force microscopy (SFM) has been used to assess the local mechanical properties of fibre-reinforced polymers. Using a sinusoidal displacement modulation (DM) and lock-in technique the method allows to characterize local viscoelastic properties with a high lateral resolution. The simultaneous measurement of the local electrical conductivity is proposed which facilitates the interpretation of the mechanical data. The investigation of cross-sections perpendicular to the axis of carbon fibres embedded in PPS delivers some information about the change in local stiffness within the interfacial region. As a first approach, assuming a single-exponential decrease in local stiffness along a radial line from fibre to polymer we find characteristic decay lengths which are distributed in a range between 20 and 80nm. Further, a modified DM-mode is proposed which is expected to provide a contrast enhancement of the signal which is related to local stiffness. This can be achieved by installing an additional feedback loop which keeps constant the amplitude of dynamic indentation (CDI-mode).
Cardiac troponin I (cTnI) is a crucial biomarker for diagnosing cardiac vascular diseases, including acute myocardial infarction (AMI). This study presents a proof-of-concept chemiluminescence-based immunosensor for rapid and accurate measurement of cTnI, with the potential for online monitoring. The immunosensor incorporates a flow cell design and a sensitive complementary metal-oxide-semiconductor (CMOS) camera for optical readout. A microfluidic setup was established to enable selective and quasi-online determination of cTnI within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer, demonstrating measurements in the concentration range of 2–25 µg/L, with a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) achieved using the optimized system. The immunosensor exhibited high selectivity, as no cross-reactivity was observed with other recombinant proteins such as cTnT and cTnC at a concentration of 16 µg/L. Measurements with diluted blood plasma and serum yielded an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively. This biosensor offers a promising approach for the rapid and sensitive detection of cTnI, contributing to the diagnosis and management of acute myocardial infarction and other cardiac vascular diseases.
The limited availability of accurate experimental data in wide ranges of pressure, temperature, and composition is the main constraining factor for the proper development and assessment of thermodynamic models and equations of state. In the particular case of carbon capture and storage (CCS) processes, there is a clear need for data sets related to the (carbon dioxide + oxygen) mixtures that this work aims to address. This work provides new experimental (p, rho, T) data for three binary (CO2 + O2) mixtures with mole fractions of oxygen x(O2) = (0.05, 0.10, and 0.20) mol/mol, in the temperature range T = (250 to 375) K and pressure range p = (0.5 to 13) MPa. The measurements were performed with a high-precision single-sinker densimeter with magnetic suspension coupling. The density data were obtained with estimated expanded relative uncertainties of 0.02 % for the highest densities and up to 0.3 % for the lowest ones.The results were compared to the corresponding results calculated by the current reference equations of state for this kind of mixtures, namely the EOS-CG (combustion gases) and the GERG-2008 equation of state, respectively. The EOS-CG yields better estimations in density than the GERG-2008 equation of state. The results from the EOS-GC model show no systematic temperature dependence. For the GERG-2008 model, however, this criterion is significantly less fulfilled.
Methane dry reforming (DRM) was investigated over highly active Ni catalysts with low metal content (2.5wt%) supported on Mg-Al mixed oxide. The aim was to minimize carbon Deposition and metal sites agglomeration on the working catalyst which are known to cause catalyst deactivation.
The solids were characterized using N2 adsorption, X-ray diffraction, temperature-programmed reduction, X-ray photoelectron spectroscopy, and UV-Vis diffuse reflectance spectroscopy. The results showed that MgO-Al2O3 solid solution phases are obtained when calcining Mg-Al hydrotalcite precursor in the temperature range of 550–800 °C. Such phases contribute to the high activity of catalysts with low Ni content even at low temperature (500 °C). Modifying the catalyst preparation with citric acid significantly slows the coking rate and reduces the size of large octahedrally coordinated NiO-like domains, which may easily agglomerate on the surface during DRM. The most effective Ni catalyst shows a stable DRM course over 60 h at high weight hourly space velocity with very low coke deposition. This is a promising result for considering such catalyst systems for further development of an industrial DRM technology.
The incorporation of colloidal quantum dots (QDs) into solid matrices, especially ionic salts, holds several advantages for industrial applications. Here, we demonstrated via absolute measurements of photoluminescence quantum yields (PL-QY) that the photoluminescence of aqueous CdTe QDs can be considerably increased upon incorporation into a salt matrix with a simple crystallization procedure. Enhancement factors of up to 2.8 and a PL-QY of 50 to 80%, both in NaCl crystals and incorporated in silicone matrices, were reached. The fact that the achievable PL enhancement factors depend strongly on PL-QY of the parent QDs can be described by the change of the dielectric surrounding and the passivation of the QD surface, modifying radiative and nonradiative rate constants. Time-resolved PL measurements revealed noncorrelating PL lifetimes and PL-QY, suggesting that weakly emissive QDs of the ensemble are more affected by the enhancement mechanism, thereby influencing PL-QY and PL lifetime in a different manner.
In situ secondary ion mass spectrometry (SIMS) analyses of δ7Li, Li/Ca, and Mg/Ca were performed on five synthetic aragonite samples precipitated from seawater at 25°C at different rates. The compositions of δ7Li in bulk aragonites and experimental fluids were measured by multicollector inductively coupled plasmamass spectrometry (MC-ICP-MS). Both techniques yielded similar δ7Li in aragonite when SIMS analyses were corrected to calcium carbonate reference materials. Fractionation factors α7Li/6Li range from 0.9895 to 0.9923, which translates to a fractionation between aragonite and fluid from -10.5‰ to -7.7‰. The within-sample δ7Li range determined by SIMS is up to 27‰, exceeding the difference between bulk δ7Li analyses of different aragonite precipitates. Moreover, the centers of aragonite hemispherical bundles (spherulites) are enriched in Li/Ca and Mg/Ca relative to spherulite fibers by up to factors of 2 and 8, respectively. The Li/Ca and Mg/Ca ratios of spherulite fibers increase with aragonite precipitation rate. These results suggest that precipitation rate is a potentially important consideration when using Li isotopes and elemental ratios in natural carbonates as a proxy for seawater composition and temperature.
Recent results from a three-year multi-disciplinary project on Ancient Egyptian gold jewellery revealed that items of jewellery from the Middle Kingdom to the New Kingdom were manufactured using a variety of alluvial gold alloys. These alloys cover a wide range of colours and the majority contain Platinum Group Elements inclusions. However, in all the gold foils analysed, these inclusions were found to be absent. In this work a selection of gilded wood and leather items and gold foil fragments, all from the excavations by John Garstang at Abydos (primarily from Middle Kingdom graves), were examined using Scanning Electron Microscopy-Energy Disperse Spectroscopy (SEM-EDS), X-Ray Fluorescence (µXRF), Particle Induced X-Ray Emission (µPIXE) and Double Dispersive X-Ray Fluorescence (D²XRF). The work allowed us to characterise the composition of the base-alloys and also to reveal the presence of Pt at trace levels, confirming the use of alluvial gold deposits. Corrosion products were also investigated in the foils where surface tarnish was visually observed. Results showed that the differences in the colour of corrosion observed for the foils are related not only to the thickness of the corrosion layer but also to a multi-layer structure containing the various corrosion products.
Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens.
In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by 'drop on demand' technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation.