For the purpose of increasing payload and reduce freight cost, lightweight composite tank containers used for Transportation have been progressively developed during the last years. Compared to conventionally produced cylindrical steel tanks, the fiber-reinforced solutions allow greater flexibility in the tank design. Despite a number of further material-related benefits of fiber-reinforced composites as non-conductive and non-magnetic behavior as well as corrosion resistance and high strength, the optimization of their thermal degradation properties during combustion is still a challenge. To improve the fire performance of lightweight composite containers, special intumescent fire protection coatings can be applied onto the outside tank surface. This paper presents fire tests on glass-fiber-reinforced plastic transport tanks with complex geometries sheltered with different surface-applied fire protection systems. To evaluate the fire resistance of the tank structures, a fiber optic monitoring system was developed. This system is based on distributed temperature measurements using high-Resolution optical backscatter reflectometry and pointwise reference measurements using fiber Bragg gratings. Thereby, all the fiber optic sensors were directly integrated in the composite layer structure of the tanks. The focus of the presented work is on the demonstration of capability of fiber optic monitoring system in such high-temperature application. Moreover, the fiber optic measurements provide new insights into the efficiency of intumescent coating applied for fire protection of fiber-reinforced plastic transport tanks.
Die Nutzung von Sensortechnologien, insbesondere im Bereich der Gasdetektion mit einem Schwerpunkt auf Wasserstoff, spielt eine entscheidende Rolle in verschiedenen Anwendungsbereichen der Wasserstofftechnologie. Sicherheitsüberwachung, Leckdetektion und Prozesskontrolle gehören zu den prominenten Anwendungsgebieten dieser Sensortechnologien. Ein zentrales Ziel ist die Erkennung von freigesetztem Wasserstoff sowie die genaue Bestimmung des Wasserstoff-Luftverhältnisses mithilfe von Gassensoren. Dies ist von entscheidender Bedeutung, um potenzielle Gefahren frühzeitig zu erkennen und angemessene Maßnahmen zu ergreifen.
Ein weiterer Schwerpunkt dieses Beitrags liegt auf der Analytik und der Verwendung zertifizierter Referenzmaterialien in Verbindung mit Metrologie für die Wasserstoffspeicherung. Dies gewährleistet eine präzise und zuverlässige Charakterisierung von Wasserstoff und unterstützt die Entwicklung sicherer Speichertechnologien. Im Rahmen des Euramet-Vorhabens Metrology for Advanced Hydrogen Storage Solutions (MefHySto) wird eine Kurzvorstellung präsentiert.
Der Vortrag stellt zwei zerstörungsfreie Prüfverfahren zum strukturellen Zustandsüberwachung (Structural Health Monitoring, SHM) für Wasserstofftechnologien vor. Insbesondere die Fehlstellenerkennung mittels geführter Ultraschallwellen spielt eine bedeutende Rolle bei der Lebensdauerüberwachung von Wasserstoffspeichern. Ein weiterer Aspekt ist die Anwendung faseroptischer Sensorik zur Schadensfrüherkennung von Wasserstoffspeichern. Diese zerstörungsfreien Prüfverfahren ermöglichen eine präzise und frühzeitige Identifizierung von Schäden, was die Sicherheit und Effizienz von Wasserstoffspeichersystemen entscheidend verbessert.
Intelligent sensor systems, certified reference materials and instrumental analytical-chemical methods contribute to safety and functionality in hydrogen technologies.
This article gives a brief overview of SensRef activities in the Competence Centre H2Safety@BAM on the issues: Analytical methods for the determination of hydrogen purity, certified reference materials as measurement standards with regard to gas quality (primary calibrators) of BAM, test methods for gas sensor systems to detect hydrogen in air as well as the application of fibre-optic sensor systems to monitor the expansion and ageing behaviour of composite containers in hydrogen technologies.
We present a high-precision fiber-optic temperature sensor based on a polymer possessing a Lower Critical Solution Temperature (LCST) in aqueous solution encapsulated in a capillary. For a temperature higher than the LCST the transparent homogenous polymer solution changes into a suspension which forms an opaque fluid. The resulting temperature-dependent turbidity influences the transmission characteristics measured using a simple fiber-optic system.
The presented development provides a small-sized, robust temperature sensor, patented by the BAM (patent nr.: EP 3 043 161 B1), easy to integrate in many application fields, especially for process monitoring.
We present a temperature sensor based on a polymer exhibiting a Lower Critical Solution Temperature (LCST) in aqueous solution encapsulated in a capillary. Parameters are chosen such that the solution exhibits a cloud point in a temperature range of 30° C to 39°C. The characteristic of thermoresponsive polymers with an LCST, is that above that temperature phase separation of the polymer takes place which leads to a temperature-dependent formation of a cloudy suspension. An optical intensity measurement over the desired temperature range is established by an increase of optical attenuation inside the polymer solution caused by a rising temperature. For our purpose, the polymer capillary is connected to transmitter and receiver via a Polymer Optical Fibre (POF). Our intensity measurement is, to the best of our knowledge, a novel method and can be considered simple when compared to existing fibre-based temperature measurement techniques. Due to the lack of electrical components at the probe, this sensor is suitable for measurements in strong electromagnetic fields and environments for which flying sparks are hazardous, i.e., inflammable fluids or gases. Furthermore, all manufactured sensors share the same temperature dependence and, therefore, are well-suited for comparative measurement, e.g., flow measurement systems. With the given temperature range, a body temperature measurement is also suitable.
The mechanical stress-strain behaviour of polymer optical fibres (POFs) drawn from various materials was measured, both before and after temperature annealing of the POFs. The POFs were drawn from PMMA (GEHR), Zeonex (480R), PC (Makrolon LED2245) and two different grades of Topas (8007S-04 and 5013S-04). With fibre drawing stresses at or above the elastic (uniaxial extensional) plateau modulus, the polymer chains in the POFs have a high degree of alignment, which has a large impact on fibre mechanical behaviour. The testing was performed at straining rates ranging from 0.011%/s, to 1.1%/s for the un-annealed fibres and a straining rate of 1.1%/s for the annealed ones. The elastic modulus of the tested POFs showed no sensitivity toward variation of straining rate. In the case of Topas 5013S-04 and PMMA, the producer-reported values are the same as the one obtained here for the POFs both before and after annealing. The drawn POFs made of Zeonex, PC, and Topas 8007S-04 exhibit larger elastic modulus than the respective materials in the bulk form. The elastic modulus of these fibres is reduced upon annealing by 10-15%, but still remains above the producer-reported values for the bulk polymers. In the nonlinear elastic region, only the PC POF is statistically unaffected by the changes in the straining rate, while Topas 8007S-04 POF shows insensitivity to the straining rate until 3% strain. All other changes affect the stress-strain curves. The annealing flattens all stress-strain curves, making the fibres more sensitive to yield.
We present the results of distributed fiber optic strain sensing for condition monitoring of a hybrid type IV composite fully wrapped pressure vessel using multilayer integrated optical fibers. Distributed strain sensing was performed for a total number of 252,000 load cycles until burst of the vessel. During this ageing test material fatigue could be monitored and spatially localized. Critical material changes were detected 17,000 cycles before material failure. Results have been validated by acoustic emission analysis.