Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (9)
- Zeitschriftenartikel (6)
- Vortrag (4)
- Posterpräsentation (3)
Schlagworte
- Distributed fiber sensing (6)
- Distributed acoustic sensing (5)
- Structural health monitoring (5)
- Distributed fiber optic sensing (4)
- Acoustic sensing (3)
- Leakage detection (3)
- Optical backscatter reflectometry (3)
- Aqueous polymer solution (2)
- Composite structures (2)
- Distributed fibre optic sensors (2)
Organisationseinheit der BAM
- 8.6 Faseroptische Sensorik (22) (entfernen)
Eingeladener Vortrag
- nein (4)
Kurzfassung. Die meisten Faserverbundbehälter, die in Europa für den Transport gefährlicher Stoffe oder als Speicherbehälter für Wasserstoff oder Erdgas in Fahrzeugen Verwendung finden, werden für eine nicht begrenzte Lebensdauer ausgelegt. In regelmäßigen Abständen sind für diese Druckbehälter wiederkehrende Prüfungen vorgeschrieben, die in der Regel aus visuellen Inspektionen und hydraulischen Innendruckprüfungen bestehen. Die wiederkehrenden Prüfungen sind jedoch weder geeignet, die sichere Betriebsdauer festzulegen noch den Alterungszustand der Druckbehälter zu beurteilen. Aufgrund des weiter steigenden Drucks zur Kosten- und Gewichtsreduktion von Faserverbundbehältern und der damit einhergehenden Ausnutzung der existierenden Sicherheitsmargen gewinnen Methoden zur Beurteilung des Alterungsverhaltens dieser Druckbehälter immer mehr an Bedeutung.
Vor diesem Hintergrund wurde in der BAM das Vorhaben „Alterungsverhalten von Composite-Druckgefäßen mit Carbonfaser-Compositen unter gekoppelten Beanspruchungen (COD-AGE)“ gestartet, um die Alterung von Faserverbundbehältern mittels verschiedener zerstörungsfreier Prüfverfahren zu untersuchen. Die hier vorgestellten Ergebnisse wurden an einem Typ 4 Hybridbehälter mit Kunststoffliner gewonnen, in den im Rahmen des Herstellungsprozesses optische Glasfasern in verschiedenen Schichten integriert wurden. Der Behälter wurde mittels hydraulischem Innendruck und erhöhter Umgebungstemperatur zyklisch bis zum Lebensende belastet. Zwischen den einzelnen Lastsequenzen erfolgte eine an die wiederkehrende Prüfung im Betrieb angelehnte hydraulische Druckbelastung.
Sowohl die hydraulische Alterung als auch die Druckrampen wurden mittels Schallemissionsprüfung (SEP) und verteilter faseroptischer Sensorik mit dem Ziel einer frühzeitigen Versagensvorhersage überwacht. Durch die Schallemissionsanalyse sollte untersucht werden, ob zum Lebensende hin ein signifikanter Anstieg der Schallemissionsaktivität und -intensität, unterteilt in verschiedene Lastbereiche, beobachtet werden kann. Zusätzlich zum kontinuierlichen Monitoring der Zyklierung sollten die Druckrampen separat untersucht werden, um hier Potenziale für die wiederkehrende Prüfung zu erkennen.
Fibre-reinforced plastics (FRP) especially carbon-fibre-reinforced polymer (CFRP) and glass-fibre-reinforced polymer (GFRP) are commonly used materials in high pressure vessels and storage units for automotive and aerospace purposes. Optical fibres are suitable to be integrated or directly applied to the surface of FRP components. Using optical fibres it is possible to monitor the distributed strain profiles and changes within the fatigue life of a pressure vessel to ensure the operational safety. Within artificial ageing experiments we used swept wavelength interferometry (SWI) based distributed strain sensing for the monitoring of commercial high-pressure composite cylinder. This artificial ageing was performed using test conditions of 503bar pressure load (service pressure 300 bar) and 89 °C for 100 h. The polyimide coated optical fibres were glued to the surface externally in circumferential and axial direction. Using distributed strain sensing (DSS) material expansion of over 0.5% were monitored with sub-centimetre spatial resolution. Within the circumferential direction we observed up to 10 % local fluctuation compared to the median strain caused by inhomogeneous material expansion, which could cause local material fatigue. In addition, we determined material degradation manifested itself as localized remaining material expansion and/or contraction. Results have been validated by other non-destructive methods like digital strip projection.
Glass-fibre-reinforced plastics (GFRP) are commonly used for the construction of pressure vessels and tanks for example in automotive and aerospace industries. Especially for pressure vessels used for the storage of natural gas or hydrogen with operation pressures up to 700 bar, an early material fatigue detection is of great interest. Measuring the distributed strain profile of GFRP structures helps to understand and detect material fatigue. In this article, we demonstrate the great potential of swept wavelength interferometry (SWI) based distributed strain sensing for the monitoring of pressure vessels made from GFRP. A resin transfer molding (RTM) process was used to manufacture GFRP-tube specimens. Commercial optical fibres with polyimid coating were glued to the surface externally in circumferential and axial direction. A cyclic load of up to 150 bar was applied to the samples using a servo-hydraulic test bench. Comparing the loaded and unloaded test conditions, we determined up to 2 % elongation in circumferential direction. We demonstrate reliable distributed strain measurements with sub-centimetre spatial resolution. By monitoring these high-resolution strain profiles, we were able to detect local material degradation that manifested itself as localized strain changes. Crucially, the material Degradation could be detected already after 75 % of dat the fatigue life before a crack appeared that led to leakage.
While hydrogen is one of the most promising energy carriers, the safety of hydrogen storage technology remains one of the most important factors for technological and societal approval. While the engineering safety factors of the pressure vessels are kept high, the periodic inspection and the limited lifetime are making the application very costly considering manpower, time, money, and material waste. The development of an integrated structural health monitoring system can allow an easy transition from the current situation to cost-effective predictive maintenance. Hence, we propose to integrate three different SHM systems into hydrogen pressure vessels, namely guided wave ultrasonics, acoustic emission, and fibre optic sensing, to continuously monitor the condition and integrity.
In this work, we evaluated the condition of a Type IV composite overwrapped pressure vessel using ultrasonic guided wave propagation. We mounted fifteen piezo-electric wafers on the composite cylinder by shaping three rings containing five sensors each. We acquired data from the sensor network following different boundary conditions with artificial damages on the selected locations. The data were evaluated with guided wave tomography techniques using ultrasonic features (amplitude, frequency, etc.) as well as artificial intelligence (AI). The results suggest that both traditional guided wave fusion techniques and AI-based characterization methods can detect artificial damages. In future work, it is planned to integrate acoustic emission and fibre optic sensing. Moreover, the measurement and the test results will be implemented into a digital twin to derive trends and make predictions on the damage propagation as well as the remaining useful lifetime.
This work has received funding from German Ministry of Economic Affairs and Climate Actions within the QI-Digital initiative (www.qi-digital.de).
Distributed fiber optic sensors for structural health monitoring of composite pressure vessels
(2024)
In diesem Beitrag geben wir einen umfassenden Überblick über unsere Forschung auf dem Gebiet der verteilten faseroptischen Sensorik für die strukturelle Zustandsüberwachung von Wasserstoffdruckbehältern aus Verbundwerkstoffen. Insbesondere zeigen wir, wie die Integration von faseroptischen Sensoren in Druckbehälter aus Verbundwerkstoffen die Sicherheit erhöht und gleichzeitig die Wartungskosten senkt. Die geringe Größe von Lichtwellenleitern ermöglicht ihre Integration in Verbundwerkstoffstrukturen während des Herstellungsprozesses, wodurch eine kontinuierliche Überwachung sowie eine präzise Erkennung und Lokalisierung von Strukturschäden während des Betriebs der Druckbehälter ermöglicht wird. Wir erörtern auch das Potenzial modernster Signalverarbeitungsmethoden und des maschinellen Lernens für die Weiterentwicklung der vorausschauenden Instandhaltung. Die von uns vorgestellten Anwendungen von faseroptischen Sensoren zeigen, dass sie einen wichtigen Beitrag zur Energiewende hin zu erneuerbaren Energien leisten können.
Kombinierte faseroptische Messungen in Bohrlöchern helfen bei der Detektion von Kleinstleckagen
(2020)
Seit November 2019 läuft ein breit angelegtes und vom BMWi gefördertes ZIM-Kooperationsprojekt zwischen der Bundesanstalt für Materialforschung und -prüfung (BAM), der IAB'Weimar gGmbH, der GKSO GmbH & Co. Projekt KG, der DEEP.KBB GmbH sowie der Rembe Consulting PartG mbB. Ziel des Forschungsvorhabens sind sowohl die Lokalisierung als auch die Quantifizierung insbesondere sehr kleiner Leckagen in einer Bohrlochverrohrung durch die Nutzung faseroptischer Messtechnik. Durch Messdatenkopplung und den Wegfall bewegungsbedingter Nachteile einer Messsonde werden wesentlich präzisere Ergebnisse zur Bewertung der Bohrlochintegrität als üblich
erwartet.
Application of Intensity-Based Coherent Optical Time Domain Reflectometry to Bridge Monitoring
(2022)
Although distributed fiber sensing techniques have been widely used in structural health monitoring, the measurement results of bridge monitoring, particularly under destructive testing, have rarely been reported. To the best of our knowledge, this paper is the first report of distributed vibration measurement results, which we obtained during a three-day destructive test on an abolished bridge. A coherent optical time domain reflectometry (COTDR) was used to acquire the vibration information while the bridge was being sawed. The obtained signal was analyzed in time and frequency domain. Some characteristics of the sawing-induced vibration were retrieved by the short-time Fourier transform; the vibration exhibited several high frequency components within the measured range up to 20 kHz and all the components appeared in the same time slot. Some unexpected signals were also detected. Thorough analysis showed that they are quite different from the sawing-induced vibration and are believed to originate from internal damage to the bridge (probably the occurrence of cracks).
A distributed acoustic sensor (DAS) based on wavelength-scanning coherent optical time domain reflectometer (WS-COTDR) is tested in an underground gas storage based on a multimode fiber for the first time to the best of our knowledge. The WS-COTDR acquires the reflection spectrum by scanning the wavelength of the laser and uses the spectra to calibrate strain. It overcomes the fading problem which is common for all DAS systems, and possesses the advantage of simple configuration and low-cost. The working principle of the system is well explained and the measurement results are presented. Various artificial and natural acoustic events have been successfully detected by the WS-COTDR. Such a sensor demonstrates several advantages over the traditional DAS systems, so it is supposed to be widely used in the oil and gas industry.
A distributed acoustic sensor (DAS) based on wavelength-scanning coherent optical time domain reflectometer (WS-COTDR) is tested in an underground gas storage based on a multimode fiber for the first time to the best of our knowledge. The WS-COTDR acquires the reflection spectrum by scanning the wavelength of the laser and uses the spectra to calibrate strain. It overcomes the fading problem which is common for all DAS systems, and possesses the advantage of simple configuration and low-cost. The working principle of the system is well explained and the measurement results are presented. Various artificial and natural acoustic events have been successfully detected by the WS-COTDR. Such a sensor demonstrates several advantages over the traditional DAS systems, so it is supposed to be widely used in the oil and gas industry.