Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (22)
- Vortrag (19)
- Zeitschriftenartikel (12)
- Buchkapitel (1)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
- Sonstiges (1)
Schlagworte
- Fatigue (22)
- Concrete (11)
- Ermüdung (8)
- Beton (5)
- Damage evolution (5)
- Gründungsstrukturen (4)
- High-cycle (4)
- Ultrasonic testing (4)
- Acoustic emission (3)
- Crack detection (3)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (27)
- 7.2 Ingenieurbau (26)
- 7.1 Baustoffe (6)
- 9 Komponentensicherheit (5)
- 9.3 Schweißtechnische Fertigungsverfahren (5)
- 8 Zerstörungsfreie Prüfung (3)
- 7.0 Abteilungsleitung und andere (2)
- 8.3 Thermografische Verfahren (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 7.3 Brandingenieurwesen (1)
Paper des Monats
- ja (1)
Bei Monopfahlgründungen von Offshore-Windenergieanlagen wird die Verbindung zwischen Monopfahl und Übergangsstück als geschraubter Ringflansch ausgeführt. Die zunehmende Leistungsfähigkeit der Windenergieanlagen führt zu immer größeren Schnittgrößen in diesem Anschluss. In der Folge erhöhen sich nicht nur die Querschnittsabmessungen, sondern es kommen auch zunehmend größere Schrauben zum Einsatz. Da die einschlägigen Regelwerke zur Bemessung dieser Verbindungen nicht für Schrauben der Größen M64 oder M72 konzipiert wurden, stellt sich die Frage der Übertragbarkeit auf solche Anwendungsfälle.
Im Rahmen des Aufsatzes werden Einflüsse diskutiert, die eine Herabsetzung der Schraubentragfähigkeit verursachen könnten. Diese Einflüsse, vornehmlich geometrische Imperfektionen, werden systematisch untersucht und ergänzend in praxisrelevanten Beispielen bewertet. Die somit gewonnenen Erkenntnisse werden für die abschließende Beurteilung der großen Schrauben in Ringflanschverbindungen herangezogen.
Monitoring an Türmen von Onshore Windenergieanlagen in Betonbauweise im Hinblick auf Ermüdung
(2024)
Der Beitrag stellt das Messkonzept sowie dessen Umsetzung für ein umfassendes Monitoringsystem an einer onshore Windenergieanlage mit einem Hybridturm vor. Dieses ist Bestandteil des Forschungsvorhabens Win-ConFat – Structure, welches neben der Validierung geeigneter Sensorik auch die Bewertung des Zustands und der möglichen Restlebensdauer der ermüdungsbeanspruchten Betonstruktur zum Ziel hat. Neben dem Monitoringsystem werden erste Messergebnisse aus den Betriebsdaten sowie vom Verhalten der Turmstruktur vorgestellt.
The fatigue damage evolution and the fatigue life of quasi-brittle materials such as concrete are not yet completely understood. Accordingly to get better insights, researchers have recently been incorporating advanced measuring techniques in their fatigue experiments. In this research, acoustic emission techniques (AET), active ultrasonic, and deformation measurements are used to track the damage evolution of concrete samples subjected to fatigue loading. The samples are subjected to constant amplitude and stepwise fatigue loading in Brazilian splitting test set-ups. Initially, a good agreement is observed between the deformation and the ultrasonic measurements in capturing the crack propagation during Brazilian splitting tests. The three fatigue damage phases could be identified with all of the three techniques. The Phase II damage rates quantified by deformation measurements and AET in stepwise fatigue tests were used to predict the number of cycles to failure at various stress
levels. The predictions were validated using the number of cycles to failure of the constant amplitude fatigue tests.
The aim of the presented study is to investigate the dynamic loading strength of an external bonded fiber-reinforced polymers (FRP) system under seismic loading. 16 bonded FRP samples under different loading speeds ranging as 0.0000167–0.8 m /s were examined to determine the characteristics of the FRP bond strength on the concrete. The mechanical tests involved measuring the concrete/FRP shear properties using a double-lap shear test. Sixteen concrete specimens were cast, strengthened and surface preparation, instrumented, and driven to failure in the LMC laboratory and the BAM laboratory (Germany). Dynamic loading increased the bonded strength mainly because of an increase in the concrete tensile strength. Experimental data are then analysed and competed with the equation given by the new European standard that develop the design of external bonded FRP. The characteristic properties and bonded strength obtained by design equation were compared. Based on the results design equation are modified.
Die heute in der Anwendung befindlichen Bemessungskonzepte für Ermüdung von Beton stammen zum Teil noch aus den 1990er Jahren und sind speziell hinsichtlich hochfester Betone konservativ ausgelegt. Um die Vorteile von Türmen für Windkraftanlagen, vor allem auch aus hochfesten Betonen, im Zuge des geplanten Ausbaus der Windenergieversorgung in Deutschland wirtschaftlich nutzbar zu machen, müssen diese Bemessungskonzepte weiterentwickelt werden. Dafür sind umfangreiche Untersuchungen zur Ermittlung von Bruchlastwechselzahlen und zur Charakterisierung der Schädigungsentwicklung unter Ermüdungsbeanspruchung erforderlich. Allgemein anerkannte bzw. verbindliche Regelwerke oder Verfahren zur experimentellen Bestimmung der Ermüdungsfestigkeit (Bruchlastwechselzahlen) an Betonproben gibt es zurzeit aber nicht und die bisher durchgeführten Untersuchungen variieren in Parametern wie Probengeometrie, Probengröße und Prüffrequenz. Eine vergleichende Analyse der Ergebnisse der Studien und insbesondere die Übertragbarkeit auf bauteilrelevante Abmessungen ist auf dieser Grundlage nur sehr eingeschränkt möglich.
In structural parts under vibrational loading fatigue cracks can initiate and grow, which can lead to structural failure. Conventional non-destructive testing methods for crack detection provide just a snapshot of fatigue crack evolution, whereas crack luminescence coating realizes clear visibility of the entire crack formation. Fatigue causing cyclic tensile tests and examinations on special test bodies allowing control of the crack opening width demonstrate a high sensitivity of the coating.
Wind turbines are exposed to a high number of load cycles during their service lifetime. Therefore, the fatigue strength verification plays an important role in their design. In general, the nominal stress method is used for the fatigue verification of the most common used butt-welded joints. The Eurocode 3 part 1–9 is the current design standard for this field of application. This paper presents recent results of fatigue tests on small-scaled specimens and large components with transverse butt welds to discuss the validity of the FAT-class. Furthermore, results from numerical simulations for the verification with the effective notch stress and the crack propagation approach are used for comparison. Based on the consistency between the numerical results and the fatigue tests, the influence of the seam geometry on the fatigue resistance was investigated. Finally, a prediction of the fatigue strength of butt-welded joints with plate thicknesses up to 80 mm was carried out.
Acoustic emission for monitoring of fatigue damage in concrete elements of wind turbine towers
(2024)
Wind energy has become an important player in the energy transition in Germany. Towers of onshore wind turbines are often designed as hybrid structures: the lower part is made of prestressed concrete whereas the upper part is made of steel tubes. The tall structures are permanently subjected to cyclic loads. A research project of BAM as part of the joint project WinConFat - Structure focusses on the evelopment of techniques to monitor fatigue damage evolution in the concrete part. Results of a previous project show that a combination of ultrasonic and acoustic emission testing can give an indication for critical conditions near the end of the fatigue life of the concrete. In the ongoing project acoustic emission sensors have been installed at the base and at the transition piece between concrete and steel of a hybrid wind turbine tower. Beside of acoustic emission measurement the sensor spacing allows for measuring the concrete ultrasonic velocity along the circumference in both levels. Additional measurements like strain, temperature, inclination, or acceleration allow for comparison of environmental loads and change of acoustic properties of the concrete. The paper focusses on first acoustic measurements recorded since December 2023 in comparison to operating data of the wind turbine.
Im Mittelpunkt der vorliegenden Arbeit steht das Ermüdungsverhalten von Beton unter hochzyklischen Druckschwellbeanspruchungen. Der aktuelle Wissensstand bezüglich des Ermüdungsverhaltens ist nach wie vor sehr lückenhaft. Ganz besonders trifft das auf den eigentlichen Ermüdungsprozess zu, der dem abschließenden Ermüdungsversagen vorausgeht. Dem Defizit im Wissen um das Ermüdungsverhalten steht allerdings eine zunehmende Bedeutung der Thematik in der Baupraxis gegenüber. Daher wurde im Rahmen dieser Arbeit eine systematische Untersuchung des Ermüdungsprozesses vorgenommen. Damit wird ein Beitrag geleistet, um einen tieferen Einblick und ein besseres Verständnis für den Schädigungsprozess und die damit verbundenen Vorgänge innerhalb des Betons zu gewinnen.
Die experimentellen Untersuchungen bestehen im Wesentlichen aus einstufigen Dauerschwingversuchen im Druckschwellbereich an zylindrischen Probekörpern aus Normalbeton. Verwendet wurden zwei verschiedene Ermüdungslastniveaus, die Bruchlastzyklen zwischen 10⁶ und 10⁷ sowie zwischen 10³ und 10⁴ erzeugten. Die Untersuchung des Ermüdungsvorgangs erfolgte durch den Einsatz verschiedener ZfP- und ZP-Methoden, wie der Dehnungsmessung, der Messung flächiger Oberflächenverformungen, der Ultraschallmessung, der Schallemissionsmessung, der Lichtmikroskopie und des Rasterelektonenmikroskops. Zur Bewertung einiger Einflussgrößen im Zusammenhang mit dem Ermüdungsverhalten fanden zudem ergänzende Versuche zum Kriecheinfluss sowie zum Einfluss der Probengröße statt.
Es konnte festgestellt werden, dass es sich bei dem Ermüdungsvorgang um eine von Beginn an einsetzende Schädigungsevolution innerhalb des Betons handelt. Diese beeinflusst die verschiedenen Materialeigenschaften des Betons in vielfältiger und sehr unterschiedlicher Weise. Die wesentlichste Feststellung in diesem Zusammenhang ist, dass die ermüdungsbedingte Materialschädigung zu einer Veränderung der gesamten Spannungs-Dehnungs-Beziehung führt, die sich ebenfalls in einem fortlaufenden Evolutionsprozess äußert.
Aus den Untersuchungen konnten als entscheidende Ursache für die beobachteten Veränderungen im makroskopischen Materialverhalten Veränderungen in der Mikrorissstruktur nicht festgestellt werden. Vielmehr weisen die Ergebnisse der Untersuchungen darauf hin, dass die ermüdungsbedingten Veränderungen speziell in den Phasen I und II vorrangig das Resultat von viskosen Prozessen innerhalb des Zementsteins sind. Darüber hinaus geht aus den Versuchen hervor, dass auch das Kriechen zu relativ ähnlichen, aber weniger stark ausgeprägten Veränderungen im Material führt. Ein Einfluss der Probengröße auf das resultierende Verhalten konnte sowohl im statischen als auch im zyklischen Fall beobachtet werden.
Aus den gewonnenen experimentellen Erkenntnissen wird eine Beschreibung der Vorgänge abgeleitet, die während des Ermüdungsprozesses im Materialgefüge ablaufen und zu den beobachteten makroskopischen Veränderungen führen. In diesem Zusammenhang hat sich herausgestellt, dass eine Erfassung der ermüdungsbedingten Schädigung anhand einer skalaren Größe über die Steifigkeit der tatsächlichen Veränderung der Spannungs-Dehnungs-Beziehung nicht gerecht wird. Eine Betrachtung im Hinblick auf einen zuverlässigen Schädigungsindikator im Zusammenhang mit den gemessenen Größen liefert zudem einen Überblick über die Eignung verschiedener Größen zur Erfassung des Ermüdungsschädigungsgrades im Beton. Abschließend wird ein Ansatz vorgestellt, der die beobachteten Entwicklungen entscheidender Größen im Ermüdungsvorgang abzubilden vermag.
Reinforced concrete is a widely used material for power generation structures, where load scenarios like impact loadings need to be considered. In this context mechanical splicing systems for the connection of reinforcement bars are of specific interest and impact resistance for the splicing systems has to be verified. High speed tensile tests need to be performed on splicing systems for reinforcement bars to confirm the capability of the coupler to resist impact loading. Furthermore, the ability of the reinforcement steel to dissipate energy by ductile behaviour with pronounced plastic strains should be confirmed by these tests. During the last decades comprehensive experiences were developed at BAM performing high speed tensile tests on reinforcement bars as well as on several splicing systems. For the lack of available standards defining these tests in detail an appropriate test procedure was developed and continuously optimized during this period at BAM. The test procedure is partially based on testing principles adapted from available standards. The main intention behind this test procedure is to perform high-speed tensile tests with a specific constant strain rate generated at the specimen. Furthermore, main objective was to establish a procedure to guarantee the comparability of test results for different diameter of reinforcement as well as for different types of couplers. Besides the pure execution of the high-speed tensile tests, the test specification also declares how to evaluate the measurements and the test results. Finally, some typical results will be presented in this contribution.