Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (67)
- Beitrag zu einem Tagungsband (52)
- Beitrag zu einem Sammelband (45)
- Vortrag (34)
- Sonstiges (7)
- Posterpräsentation (6)
- Buchkapitel (3)
Schlagworte
- Computed tomography (25)
- X-ray refraction (19)
- Reconstruction algorithm (12)
- Computer-Tomographie (10)
- DIRECTT (8)
- Electron tomography (8)
- Rekonstruktionsalgorithmen (8)
- Computertomographie (7)
- Keramik (6)
- Synchrotron radiation (6)
- Composites (5)
- Radiography (5)
- Refraction (5)
- Tomography (5)
- Catalyst (4)
- Ceramics (4)
- Computed Tomography (4)
- Diffuse background (4)
- Fluorescent screen (4)
- Fuel cell (4)
- Komposite (4)
- Missing wedge (4)
- Neutron tomography (4)
- Neutronen-Tomographie (4)
- Phase contrast (4)
- Pore size (4)
- Porous ceramics (4)
- Röntgenrefraktion (4)
- Synchrotron (4)
- X-ray refraction topography (4)
- Aerospace (3)
- Computertomographie (CT) (3)
- Elektronen-Tomographie (3)
- Explosivstoffe (3)
- Hinterleuchten (3)
- Iterative reconstruction (3)
- Limited view (3)
- Materialcharakterisierung (3)
- NDE (3)
- Non-destructive testing (3)
- Polymer electrolyte membrane fuel cell (PEMFC) (3)
- Pore orientation (3)
- Porosity (3)
- Rekonstruktionsalgorithmus (3)
- Röntgen-Refraktions-Topographie (3)
- Soft matter radiography (3)
- Statistische Bewertung (3)
- Synchrotron Radiation (3)
- WAXS (3)
- X-ray (3)
- X-ray Refraction (3)
- X-ray detector backlighting (3)
- X-ray tomography (3)
- X-ray topography (3)
- BAMline (2)
- Bragg magnification (2)
- Cartilage (2)
- Characterization (2)
- Computed Tomography (CT) (2)
- DEI (2)
- Diesel particulate filters (2)
- Diffraction Enhanced Imaging (DEI) (2)
- Diffraction enhanced imaging (2)
- Edge artefact (2)
- Elektronentomographie (2)
- Explosives (2)
- Fluoreszenzschirm (2)
- Foams (2)
- Focal smearing (2)
- Gas diffusion layer (GDL) (2)
- Grating interferometry (2)
- Huygens elementary waves (2)
- Iterative Rekonstruktion (2)
- Kleinwinkelstreuung (2)
- Lightweight Materials (2)
- Lightweight materials (2)
- MMC (2)
- Magnetic domains (2)
- Metal Matrix Composites (MMC) (2)
- Metal matrix composites (2)
- Neutron imaging (2)
- Neutronentomographie (2)
- Nichtmetallische Werkstoffe (2)
- Non-Destructive Inspection (NDI) (2)
- Ortsauflösung (2)
- PEM fuel cell (2)
- Radiographie (2)
- Refraction enhanced imaging (REI) (2)
- Refraction topography (2)
- Region of interest (2)
- Röntgen-Streuung (2)
- Röntgendetektor (2)
- Röntgentomographie (2)
- Spatial resolution (2)
- Specific surface (2)
- Synchrotron Refraction CT (2)
- Synchrotron refraction computed tomography (2)
- Synchrotronstrahlung (2)
- Terahertz-Radiographie (2)
- Ti-MMC (2)
- Tomographische Rekonstruktionsalgorithmen (2)
- Topography (2)
- Water management (2)
- X-Ray Refraction (2)
- X-ray compton scattering (2)
- X-ray refraction tomography (2)
- X-ray scattering (2)
- 3D microstructure (1)
- 3D topography (1)
- 3D-Mikrostruktur (1)
- Advanced Composite (1)
- Advanced ceramics (1)
- Al2O3 ceramics (1)
- Algorithm (1)
- Analyser based imaging (1)
- Analyser-based imaging (1)
- Analyzer based imaging (1)
- Average pore size (1)
- Backlight (1)
- Beta-eucryptite (1)
- Beton (1)
- Bildgebende Radiologie (1)
- Bildgebende Röntgenverfahren (1)
- Bragg Magnification (1)
- Bragg-Magnification (1)
- Bragg-Vergrößerung (1)
- Brennfleck (1)
- Brennstoffzelle (1)
- Brennstoffzellen (1)
- C/C Keramiken (1)
- CFK (1)
- CFRP (1)
- CT (1)
- CT-Algorithmus (1)
- Cavitation (1)
- Coherent imaging (1)
- Complex microstructure (1)
- Composite damaging (1)
- Compounds (1)
- Compression device (1)
- Comptonstreuung (1)
- Computed topography (1)
- Computer Tomographie (1)
- Computer tomography (1)
- Computerised tomography (1)
- Computertomografie (1)
- Concrete (1)
- Cordierit (1)
- Crack Density (1)
- Crack density (1)
- Crystal Texture (1)
- DIVA Algorithm (1)
- DIVA algorithm (1)
- Darkfield imaging (1)
- Detector backlighting (1)
- Detector calibration (1)
- Detektor (1)
- Diesel Fuel (1)
- Diffraktion (1)
- Double-Crystal-Monochromator with sagittal bender (1)
- Double-Multilayer-Monochromator with meridional bender (1)
- Dual Energy (1)
- Dunkelfeldabbildung (1)
- Electronic Power Device IC (1)
- Ermüdung (1)
- Ermüdungsrisse (1)
- FAXOT (1)
- Fatigue (1)
- Few angles (1)
- Fibre Debonding (1)
- Fibre orientation (1)
- Filtering (1)
- Fluorescence screen (1)
- Fuel cell stack (1)
- Gefilterte Rückprojektion (1)
- Geometrical tortuosity (1)
- High pressure mercury intrusion (1)
- Hochleistungswerkstoffe (1)
- Holotomography (1)
- Image morphology (1)
- Impact (1)
- In-Situ Radiologie (1)
- Inhomogeneous materials (1)
- Inner surface (1)
- Inner surface density (1)
- Interface (1)
- Interfaces (1)
- Internal Surfaces (1)
- Internal surface density (1)
- Iterative CT reconstruction (1)
- Konvergenz (1)
- Kurzzeit-Radiometrie (1)
- Limited View (1)
- Limited tomographic data (1)
- Manifold stack (1)
- Materialcharakterisierung und -identifizierung (1)
- Mehrphasige Materialien (1)
- Mercury intrusion porosimetry (1)
- Metal Matrix Composites (1)
- Metal matrix composite (MMC) (1)
- Metrology (1)
- Micro cracks (1)
- Micro-CT (1)
- Micro-computed tomography (1)
- Microcracked ceramics (1)
- Microstructure (1)
- Microstructures (1)
- Microtomography (1)
- Mikroriß (1)
- Missing Wedge (1)
- Modulations-Transfer-Funktion (1)
- Modulations-Transfer-Funktion (MTF) (1)
- Molecular probe (1)
- Monochromatische Radiometrie (1)
- Montmorillonites (1)
- Morphological image analysis (1)
- Multiple View Inspection (1)
- Nanocomposites (1)
- Nanocracks (1)
- Nanostructures (1)
- Nanostrukturen (1)
- Neues Prinzip der computer-tomographischen Rekonstruktion ohne Fourier-Filterung (1)
- Neutron computed tomography (1)
- Neutronen-Radiographie (1)
- Neutrons (1)
- Non-destructive evaluation (1)
- Non-metallics (1)
- Nondestructive characterization (1)
- Nondestructive materials characterisation (1)
- Nondestructive testing (1)
- Oberfläche, innen (1)
- Opacity (1)
- Oxidative Schädigung (1)
- PE-HD Sorption (1)
- Phase boundary (1)
- Phase contrast radiography (1)
- Phase grating (1)
- Phase-contrast X-ray imaging (1)
- Polymers (1)
- Polypropylene-graft-maleic anhydride (1)
- Pore Orientation (1)
- Pore Size (1)
- Pore size analysis (1)
- Porengröße (1)
- Porenorientierung (1)
- Porosity fluctuation (1)
- Porous Ceramics (1)
- Poröse Keramik (1)
- Quantitative image analysis (1)
- Quenching (1)
- Radiology (1)
- Reconstruction (1)
- Reconstruction algorithms (1)
- Reconstruction algrorithm (1)
- Reflectometry (1)
- Refraktion (1)
- Refraktionskontrast (1)
- Refraktionstopographie (1)
- Rekristallisation (1)
- Renewable energy (1)
- Rissdichte (1)
- Risse (1)
- Röntgen-Diffraktions-Mikroskopie (1)
- Röntgen-Kanten-Tomographie (1)
- Röntgen-Refraktion (1)
- Röntgen-Refraktions-Computer-Tomographie (1)
- Röntgen-Szintillationsdetektor hoher Zählraten (1)
- Röntgen-Topographie (1)
- Röntgen-Topographie und -Streuung (1)
- Röntgenstreuverfahren (1)
- SAXS (1)
- SCS6 (1)
- SRCT (1)
- Scanning transmission electron microscopy (STEM) (1)
- Schlagfestigkeit (1)
- Scintillator (1)
- Shearing gratings (1)
- Small angle scattering (1)
- Spatial reslution (1)
- Spatial statistics (1)
- Specific surface area (1)
- Spectral computed tomography (1)
- Statistical analysis (1)
- Strain hardening (1)
- Stromdichtemessung (1)
- Structural (1)
- Structure property relations (1)
- Surface density (1)
- Synchrotron Laue Contrast Radiography (1)
- Synchrotron Laue Contrast Radiography SLCR (1)
- Synchrotron X-ray tomography (1)
- Synchrotron instrumentation (1)
- Synchrotron radiography (1)
- Synchrotron, BAMline (1)
- Synchrotron-CT (1)
- Synchrotron-Radiographie (1)
- Talbot- Lau interferometry (1)
- Talbot-Lau (1)
- Talbot-Lau interferometer (1)
- Talbot-Lau neutron tomography (1)
- Tensile load (1)
- Terahertz Imaging (1)
- Terahertz time domain spectroscopy (1)
- Terahertz-Radiography (1)
- Texture (1)
- Thermal stability (1)
- Thermoplaste (1)
- Threat Detection (1)
- Three-dimensional data quantification (1)
- Ti6242 (1)
- Titanium Metal Matrix Composites (Ti-MMC) (1)
- Tomographic reconstruction (1)
- Tomographische Rekonstruktions-Algorithmen (1)
- Tortuosity (1)
- USAXS (1)
- Verbundwerkstoff (1)
- Vergrößerung mit asymmetrischen Kristallen (1)
- Verschmierung (1)
- Visibility (1)
- Wassermanagement (1)
- Water transport path (1)
- Wavelet transform (1)
- Wavelet transformation (1)
- Wide angle X-ray scattering (1)
- X-Ray Computed Tomography (1)
- X-ray absorption and refraction CT (1)
- X-ray computed tomography (1)
- X-ray detector (1)
- X-ray detector scattering (1)
- X-ray diffraction (1)
- X-ray diffraction microscopy (1)
- X-ray fluorescence analysis (1)
- X-ray imaging (1)
- X-ray microscopy (1)
- X-ray phase contrast (1)
- X-ray refractometry (1)
- X-ray scattering topography (1)
- XROT (1)
- Zerstörungsfrei (1)
- Zerstörungsfreie Materialcharakterisierung (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (34)
High performance composites and other light weight materials are generally a comple problem to the performance of nondestructive testing methods. X-ray refraction provide unconventional X-ray scattering techniques to meet the actual demand for improve nondestructive characterization of these advanced materials. Scanning the samples across collimated narrow incident X-ray beam permits to image integral micro-structures (a present) with a resolution of 10 µm. Investigations of samples after strain-induced micro cracks and fibre debonding in impact damaged epoxy are shown.
The physics of X-ray refraction are analogous to the well known refraction of light b optical lenses and prisms, governed by Snell's law. The special feature is the deflection a very small angles of few minutes of arc, as the refractive index of X-rays in matter i nearly one. Due to the density differences at inner surfaces most of the incident X-rays ar deflected. As the scattered intensity of refraction is proportional to the specific surface of sample, a reference standard gives a quantitative measure for analytical determinations.
Figure 1 represents a two-dimensional damage distribution of an impact in a 0/90° CFR laminate of 3 mm, thickness. Unlike in ultrasonic testing, there is no shadowing effect o the successive layers. By use of X-ray refraction the exact concentration of debonde fibres is calculated for each position. Additionally the refraction allows the selection of th fibre orientation.
X-Ray Refraction Techniques
(2005)