Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (67)
- Beitrag zu einem Tagungsband (52)
- Beitrag zu einem Sammelband (45)
- Vortrag (34)
- Sonstiges (7)
- Posterpräsentation (6)
- Buchkapitel (3)
Schlagworte
- Computed tomography (25)
- X-ray refraction (19)
- Reconstruction algorithm (12)
- Computer-Tomographie (10)
- DIRECTT (8)
- Electron tomography (8)
- Rekonstruktionsalgorithmen (8)
- Computertomographie (7)
- Keramik (6)
- Synchrotron radiation (6)
- Composites (5)
- Radiography (5)
- Refraction (5)
- Tomography (5)
- Catalyst (4)
- Ceramics (4)
- Computed Tomography (4)
- Diffuse background (4)
- Fluorescent screen (4)
- Fuel cell (4)
- Komposite (4)
- Missing wedge (4)
- Neutron tomography (4)
- Neutronen-Tomographie (4)
- Phase contrast (4)
- Pore size (4)
- Porous ceramics (4)
- Röntgenrefraktion (4)
- Synchrotron (4)
- X-ray refraction topography (4)
- Aerospace (3)
- Computertomographie (CT) (3)
- Elektronen-Tomographie (3)
- Explosivstoffe (3)
- Hinterleuchten (3)
- Iterative reconstruction (3)
- Limited view (3)
- Materialcharakterisierung (3)
- NDE (3)
- Non-destructive testing (3)
- Polymer electrolyte membrane fuel cell (PEMFC) (3)
- Pore orientation (3)
- Porosity (3)
- Rekonstruktionsalgorithmus (3)
- Röntgen-Refraktions-Topographie (3)
- Soft matter radiography (3)
- Statistische Bewertung (3)
- Synchrotron Radiation (3)
- WAXS (3)
- X-ray (3)
- X-ray Refraction (3)
- X-ray detector backlighting (3)
- X-ray tomography (3)
- X-ray topography (3)
- BAMline (2)
- Bragg magnification (2)
- Cartilage (2)
- Characterization (2)
- Computed Tomography (CT) (2)
- DEI (2)
- Diesel particulate filters (2)
- Diffraction Enhanced Imaging (DEI) (2)
- Diffraction enhanced imaging (2)
- Edge artefact (2)
- Elektronentomographie (2)
- Explosives (2)
- Fluoreszenzschirm (2)
- Foams (2)
- Focal smearing (2)
- Gas diffusion layer (GDL) (2)
- Grating interferometry (2)
- Huygens elementary waves (2)
- Iterative Rekonstruktion (2)
- Kleinwinkelstreuung (2)
- Lightweight Materials (2)
- Lightweight materials (2)
- MMC (2)
- Magnetic domains (2)
- Metal Matrix Composites (MMC) (2)
- Metal matrix composites (2)
- Neutron imaging (2)
- Neutronentomographie (2)
- Nichtmetallische Werkstoffe (2)
- Non-Destructive Inspection (NDI) (2)
- Ortsauflösung (2)
- PEM fuel cell (2)
- Radiographie (2)
- Refraction enhanced imaging (REI) (2)
- Refraction topography (2)
- Region of interest (2)
- Röntgen-Streuung (2)
- Röntgendetektor (2)
- Röntgentomographie (2)
- Spatial resolution (2)
- Specific surface (2)
- Synchrotron Refraction CT (2)
- Synchrotron refraction computed tomography (2)
- Synchrotronstrahlung (2)
- Terahertz-Radiographie (2)
- Ti-MMC (2)
- Tomographische Rekonstruktionsalgorithmen (2)
- Topography (2)
- Water management (2)
- X-Ray Refraction (2)
- X-ray compton scattering (2)
- X-ray refraction tomography (2)
- X-ray scattering (2)
- 3D microstructure (1)
- 3D topography (1)
- 3D-Mikrostruktur (1)
- Advanced Composite (1)
- Advanced ceramics (1)
- Al2O3 ceramics (1)
- Algorithm (1)
- Analyser based imaging (1)
- Analyser-based imaging (1)
- Analyzer based imaging (1)
- Average pore size (1)
- Backlight (1)
- Beta-eucryptite (1)
- Beton (1)
- Bildgebende Radiologie (1)
- Bildgebende Röntgenverfahren (1)
- Bragg Magnification (1)
- Bragg-Magnification (1)
- Bragg-Vergrößerung (1)
- Brennfleck (1)
- Brennstoffzelle (1)
- Brennstoffzellen (1)
- C/C Keramiken (1)
- CFK (1)
- CFRP (1)
- CT (1)
- CT-Algorithmus (1)
- Cavitation (1)
- Coherent imaging (1)
- Complex microstructure (1)
- Composite damaging (1)
- Compounds (1)
- Compression device (1)
- Comptonstreuung (1)
- Computed topography (1)
- Computer Tomographie (1)
- Computer tomography (1)
- Computerised tomography (1)
- Computertomografie (1)
- Concrete (1)
- Cordierit (1)
- Crack Density (1)
- Crack density (1)
- Crystal Texture (1)
- DIVA Algorithm (1)
- DIVA algorithm (1)
- Darkfield imaging (1)
- Detector backlighting (1)
- Detector calibration (1)
- Detektor (1)
- Diesel Fuel (1)
- Diffraktion (1)
- Double-Crystal-Monochromator with sagittal bender (1)
- Double-Multilayer-Monochromator with meridional bender (1)
- Dual Energy (1)
- Dunkelfeldabbildung (1)
- Electronic Power Device IC (1)
- Ermüdung (1)
- Ermüdungsrisse (1)
- FAXOT (1)
- Fatigue (1)
- Few angles (1)
- Fibre Debonding (1)
- Fibre orientation (1)
- Filtering (1)
- Fluorescence screen (1)
- Fuel cell stack (1)
- Gefilterte Rückprojektion (1)
- Geometrical tortuosity (1)
- High pressure mercury intrusion (1)
- Hochleistungswerkstoffe (1)
- Holotomography (1)
- Image morphology (1)
- Impact (1)
- In-Situ Radiologie (1)
- Inhomogeneous materials (1)
- Inner surface (1)
- Inner surface density (1)
- Interface (1)
- Interfaces (1)
- Internal Surfaces (1)
- Internal surface density (1)
- Iterative CT reconstruction (1)
- Konvergenz (1)
- Kurzzeit-Radiometrie (1)
- Limited View (1)
- Limited tomographic data (1)
- Manifold stack (1)
- Materialcharakterisierung und -identifizierung (1)
- Mehrphasige Materialien (1)
- Mercury intrusion porosimetry (1)
- Metal Matrix Composites (1)
- Metal matrix composite (MMC) (1)
- Metrology (1)
- Micro cracks (1)
- Micro-CT (1)
- Micro-computed tomography (1)
- Microcracked ceramics (1)
- Microstructure (1)
- Microstructures (1)
- Microtomography (1)
- Mikroriß (1)
- Missing Wedge (1)
- Modulations-Transfer-Funktion (1)
- Modulations-Transfer-Funktion (MTF) (1)
- Molecular probe (1)
- Monochromatische Radiometrie (1)
- Montmorillonites (1)
- Morphological image analysis (1)
- Multiple View Inspection (1)
- Nanocomposites (1)
- Nanocracks (1)
- Nanostructures (1)
- Nanostrukturen (1)
- Neues Prinzip der computer-tomographischen Rekonstruktion ohne Fourier-Filterung (1)
- Neutron computed tomography (1)
- Neutronen-Radiographie (1)
- Neutrons (1)
- Non-destructive evaluation (1)
- Non-metallics (1)
- Nondestructive characterization (1)
- Nondestructive materials characterisation (1)
- Nondestructive testing (1)
- Oberfläche, innen (1)
- Opacity (1)
- Oxidative Schädigung (1)
- PE-HD Sorption (1)
- Phase boundary (1)
- Phase contrast radiography (1)
- Phase grating (1)
- Phase-contrast X-ray imaging (1)
- Polymers (1)
- Polypropylene-graft-maleic anhydride (1)
- Pore Orientation (1)
- Pore Size (1)
- Pore size analysis (1)
- Porengröße (1)
- Porenorientierung (1)
- Porosity fluctuation (1)
- Porous Ceramics (1)
- Poröse Keramik (1)
- Quantitative image analysis (1)
- Quenching (1)
- Radiology (1)
- Reconstruction (1)
- Reconstruction algorithms (1)
- Reconstruction algrorithm (1)
- Reflectometry (1)
- Refraktion (1)
- Refraktionskontrast (1)
- Refraktionstopographie (1)
- Rekristallisation (1)
- Renewable energy (1)
- Rissdichte (1)
- Risse (1)
- Röntgen-Diffraktions-Mikroskopie (1)
- Röntgen-Kanten-Tomographie (1)
- Röntgen-Refraktion (1)
- Röntgen-Refraktions-Computer-Tomographie (1)
- Röntgen-Szintillationsdetektor hoher Zählraten (1)
- Röntgen-Topographie (1)
- Röntgen-Topographie und -Streuung (1)
- Röntgenstreuverfahren (1)
- SAXS (1)
- SCS6 (1)
- SRCT (1)
- Scanning transmission electron microscopy (STEM) (1)
- Schlagfestigkeit (1)
- Scintillator (1)
- Shearing gratings (1)
- Small angle scattering (1)
- Spatial reslution (1)
- Spatial statistics (1)
- Specific surface area (1)
- Spectral computed tomography (1)
- Statistical analysis (1)
- Strain hardening (1)
- Stromdichtemessung (1)
- Structural (1)
- Structure property relations (1)
- Surface density (1)
- Synchrotron Laue Contrast Radiography (1)
- Synchrotron Laue Contrast Radiography SLCR (1)
- Synchrotron X-ray tomography (1)
- Synchrotron instrumentation (1)
- Synchrotron radiography (1)
- Synchrotron, BAMline (1)
- Synchrotron-CT (1)
- Synchrotron-Radiographie (1)
- Talbot- Lau interferometry (1)
- Talbot-Lau (1)
- Talbot-Lau interferometer (1)
- Talbot-Lau neutron tomography (1)
- Tensile load (1)
- Terahertz Imaging (1)
- Terahertz time domain spectroscopy (1)
- Terahertz-Radiography (1)
- Texture (1)
- Thermal stability (1)
- Thermoplaste (1)
- Threat Detection (1)
- Three-dimensional data quantification (1)
- Ti6242 (1)
- Titanium Metal Matrix Composites (Ti-MMC) (1)
- Tomographic reconstruction (1)
- Tomographische Rekonstruktions-Algorithmen (1)
- Tortuosity (1)
- USAXS (1)
- Verbundwerkstoff (1)
- Vergrößerung mit asymmetrischen Kristallen (1)
- Verschmierung (1)
- Visibility (1)
- Wassermanagement (1)
- Water transport path (1)
- Wavelet transform (1)
- Wavelet transformation (1)
- Wide angle X-ray scattering (1)
- X-Ray Computed Tomography (1)
- X-ray absorption and refraction CT (1)
- X-ray computed tomography (1)
- X-ray detector (1)
- X-ray detector scattering (1)
- X-ray diffraction (1)
- X-ray diffraction microscopy (1)
- X-ray fluorescence analysis (1)
- X-ray imaging (1)
- X-ray microscopy (1)
- X-ray phase contrast (1)
- X-ray refractometry (1)
- X-ray scattering topography (1)
- XROT (1)
- Zerstörungsfrei (1)
- Zerstörungsfreie Materialcharakterisierung (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (34)
Magnetic domains have been the subject of much scientific investigation since their theoretical existence was first postulated by P.-E. Weiss over a century ago. Up to now, the three-dimensional (3D) domain structure of bulk magnets has never been observed owing to the lack of appropriate experimental methods. Domain analysis in bulk matter thus remains one of the most challenging tasks in research on magnetic materials. All current domain observation methods are limited to studying surface domains or thin magnetic films. As the properties of magnetic materials are strongly affected by their domain structure, the development of a technique capable of investigating the shape, size and distribution of individual domains in three dimensions is of great importance. Here, we show that the novel technique of Talbot-Lau neutron tomography with inverted geometry enables direct imaging of the 3D network of magnetic domains within the bulk of FeSi crystals.
This paper gives a brief overview on3D imaging of magnetic domains with shearing grating neutron tomography. We investigated the three-dimensional distribution of magnetic domain walls in the bulk of a wedge-shaped FeSi single crystal. The width of the magnetic domains wasanalyzed at different locations within the crystal. Magnetic domains close to the tip of the wedge are much smaller than in the bulk. Furthermore, the three-dimensional shape of individual domains wasinvestigated. We discuss prospects and limitations of the applied measurement technique.
Microstructural aspects of composites such as reinforcement particle size, shape, and distribution play important roles in deformation behavior. In addition, Fe-rich inclusions and porosity also influence the behavior of these composites, particularly under fatigue loading. Three-dimensional (3-D) visualization of porosity and Fe-rich inclusions in three dimensions is critical to a thorough understanding of fatigue resistance of metal matrix composites (MMCs), because cracks often initiate at these defects. In this article, we have used X-ray synchrotron tomography to visualize and quantify the morphology and size distribution of pores and Fe-rich inclusions in a SiC particle-reinforced 2080 Al alloy composite. The 3-D data sets were also used to predict and understand the influence of defects on the deformation behavior by 3-D finite element modeling.
We present a synchrotron X-ray tomographic study on the morphology of carbon fiber-based gas diffusion layer (GDL) material under compression. A dedicated compression device is used to provide well-defined compression conditions. A flat compression punch is employed to study the fiber geometry at different degrees of compression. Transport relevant geometrical parameters such as porosity, pore size and tortuosity distributions are calculated. The geometric properties notably change upon compression which has direct impact on transport conditions for gas and fluid flow. The availability of broad 3D paths, which are most important for the transport of liquid water from the catalyst layer through the GDL, is markedly reduced after compression. In a second experiment, we study the influence of the channel-land-pattern of the flow-field on shape and microstructure of the GDL. A flow-field compression punch is employed to reproduce the inhomogeneous compression conditions found during fuel cell assembly. While homogenously compressed underneath the land the GDL is much less and inhomogeneously compressed under the channel. The GDL material extends far into the channel volume where it can considerably influence gas and fluid flow. Loose fiber endings penetrate deeply into the channel and form obstacles for the discharge of liquid water droplets.
Aufgrund des hohen Wirkungsgrades und der vielfältigen Einsatzmöglichkeiten können Brennstoffzellen einen wichtigen Beitrag zur zukünftigen Energieversorgung leisten. Für die Optimierung der Brennstoffzellentechnik ist es erforderlich, die während des Zellbetriebs ablaufenden Prozesse zu verstehen und exakt zu charakterisieren. Ein ausbalanciertes Wassermanagement ist die Grundlage für die optimale Leistungsfähigkeit einer wasserstoffbetriebenen Zelle. Das während des Betriebs entstehende Wasser muss die Membran ausreichend befeuchten, um deren Protonenleitfähigkeit aufrechtzuerhalten. Andererseits behindern zu große Wasseransammlungen in der Zelle die Gaszufuhr durch die porösen Materialien sowie in den Kanälen der Gasverteilerstrukturen. Alterungsphänomene einzelner Zellkomponenten können die Verteilung der Wasseransammlungen und somit das Wassermanagement empfindlich stören und so die Leistungsfähigkeit der Brennstoffzelle herabsetzen. Zur Analyse der Wasserverteilung werden zerstörungsfreie, bildgebende Methoden, wie die Ex-situ-Neutronentomografie und die In-situ-Synchrotronradiografie, eingesetzt. Diese Methoden können während des Brennstoffzellenbetriebs mit weiteren Messverfahren, beispielsweise der ortsaufgelösten Stromdichtemessung, kombiniert werden. Auf diese Weise werden einzelne Komponenten, wie zum Beispiel die Gasdiffusionsschichten, charakterisiert.
Auf Grund des hohen Wirkungsgrades und der vielfältigen Einsatzmöglichkeiten stellen Brennstoffzellen sowie Brennstoffzellenverbünde eine vielversprechende Energiequelle dar. Daher ist es wichtig, die Prozesse während des Betriebs einer Brennstoffzelle exakt charakterisieren zu können, um diese im nächsten Schritt zu optimieren.
So ist ein ausbalanciertes Wassermanagement in einer mit Wasserstoff betriebenen Zelle ausschlaggebend für ihre Leistungsfähigkeit. Für eine dauerhafte Leistungsfähigkeit muss das entstehende Wasser die Membran feucht halten, um so die Protonenleitfähigkeit aufrecht zu erhalten. Zu viel Wasser kann jedoch die Gaszufuhr durch die porösen Materialien in Richtung Membran verhindern.
Alterungsphänomene der einzelnen Komponenten können dieses sensible Wassermanagement stören und so die Leistungsfähigkeit einer Brennstoffzelle
herabsetzen. Zum tieferen Verständnis der Wasserverteilung werden zerstörungsfreie Methoden, wie zum Beispiel die ex situ Neutronentomografie oder die in situ Synchrotronradiografie eingesetzt. Letztere Methode kann während des Brennstoffzellenbetriebs in Kombination mit weiteren Messmethoden, wie der ortsaufgelösten Stromdichtemessung, eingesetzt werden. So können einzelne Brennstoffzellenkomponenten, wie die Gasdiffusionsschichten, charakterisiert werden.
Tomographische Messungen in Transmissions-Elektronenmikroskopen beziehen ihren Reiz aus der hohen Ortsauflösung im Nanometerbereich. Allerdings bringen sie neben dem hohen Aufwand bei der Probenpräparation auch eine außerordentliche Häufung von Restriktionen der Messung mit sich, die bei Verwendung herkömmlicher Rekonstruktionsalgorithmen zu erheblichen Artefakten führen. Diese Restriktionen betreffen: partielle Nichtdurchstrahlbarkeit, einen eingeschränkten Winkelbereich, wenige Projektionen in Bezug auf die Detektorgröße, Probenabbildungen größer als der Detektor, instabile Rotationsachse, variierende Winkelinkremente sowie Probenveränderungen während der Messung.
Der DIRECTT-Algorithmus (Direkte iterative Rekonstruktion computertomographischer Trajektorien) kann, abgesehen von der Probenveränderung, sämtliche dieser Restriktionen geeignet berücksichtigen. Die auftretenden, teils unvollständigen Bahnen lassen sich mittels einer Treffertabelle und geeigneter Auswahl iterativ behandeln. Außerdem kann das Rekonstruktionsvolumen über die Detektorlänge hinaus erweitert werden.
Damit gelingt eine weitgehende Unterdrückung von Rekonstruktionsartefakten, insbesondere der sonst dominanten Streifenartefakte, und eine deutliche Erhöhung der Ortsauflösung. Die Verbesserung der Rekonstruktionsqualität wird anhand von Modell- und experimentellen Daten gezeigt.
The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography
reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.
X-ray compton tomography
(2014)
The potentials of incoherent X-ray Scattering (Compton) tomography are investigated. Imaging materials of very different density or atomic number at once is a perpetual challenge for X-ray tomography or radiography, in general. In a basic laboratory set-up for simultaneous perpendicular Compton Scattering and direct beam attenuation tomographic scans are conducted by single channel photon counting. This results in asymmetric distortions of the projection profiles of the scattering CT-data set. ln a first approach corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts.
A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials.
Compärison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT bears the potential to replace neutron tomography, which requires much more efforts.
X-ray dark field imaging
(2014)
A new kind of enhanced contrast X-ray imaging of weakly absorbing materials in dark field mode is presented.
Samples such as plastics and biological tissue are a perpetual challenge for radiographic imaging. Recent innovative approaches such as Diffraction Enhanced Imaging (DEI), “phase contrast”, grating interferometry (Talbot-Lau), or Refraction Enhanced Imaging (REI) have in common that they yield enhanced contrast based on deflected X-rays.
Here, we introduce a REI modification, which works with a slightly bent single crystal reflecting in Bragg geometry. The samples are placed upstream of the thin crystal within a parallel synchrotron beam. The crystal’s curvature creates a dark-field stripe in the transmission image, similar to the inverse of a Darwin-Prins rocking curve of plane crystals. The reflection condition is met better or worse as a steady function of incidence position.
Refracted beam portions of sample interfaces appear bright on black stripes. The entire image is finally synthesized by multiple dark-field stripes. The technique is an alternative to the mentioned techniques. We demonstrate the technique’s advantage by examples of biological and technical microstructures.
High performance composites and other light weight materials are generally a comple problem to the performance of nondestructive testing methods. X-ray refraction provide unconventional X-ray scattering techniques to meet the actual demand for improve nondestructive characterization of these advanced materials. Scanning the samples across collimated narrow incident X-ray beam permits to image integral micro-structures (a present) with a resolution of 10 µm. Investigations of samples after strain-induced micro cracks and fibre debonding in impact damaged epoxy are shown.
The physics of X-ray refraction are analogous to the well known refraction of light b optical lenses and prisms, governed by Snell's law. The special feature is the deflection a very small angles of few minutes of arc, as the refractive index of X-rays in matter i nearly one. Due to the density differences at inner surfaces most of the incident X-rays ar deflected. As the scattered intensity of refraction is proportional to the specific surface of sample, a reference standard gives a quantitative measure for analytical determinations.
Figure 1 represents a two-dimensional damage distribution of an impact in a 0/90° CFR laminate of 3 mm, thickness. Unlike in ultrasonic testing, there is no shadowing effect o the successive layers. By use of X-ray refraction the exact concentration of debonde fibres is calculated for each position. Additionally the refraction allows the selection of th fibre orientation.
X-Ray Refraction Techniques
(2005)
Quantitative X-ray refraction topography is applied for improved nondestructive evaluation of advanced high performance ceramics. The method is based on X-ray small angle scattering by refraction of X-rays due to density differences of microstructures in heterogeneous materials. It determines the amount of inner surfaces and interfaces within the range of µm to nm dimensions. As the scattered refraction intensity is proportional to the inner surface density of a sample, a reference standard gives a quantitative measure for analytical requirements. X-ray refraction scanning topography visualizes integral interface properties at 10 µm spatial resolution by two-dimensional computer images. Characteristic microstructure parameters, i.e. density fluctuation, porosity and pore size distribution of several examples of SiO[2]-and SiC ceramics at different stages of sintering are presented.
Kohlenstofffaser verstärkte Kohlenstoffe werden während ihres Ge-brauches an Luft zwischen 600°C und 1000°C korrodiert. Um zu überprüfen, ob die Röntgerefraktionsmethode als zerstörungsfreies Prüfverfahren die bei der Oxidation auftretenden morphologischen Änderungen im Probekörper signifikant nachweisen können, wurden bei 630°C oxidativ geschädigte gasphaseninfiltrierte C/C Kerami-ken untersucht. Anhand eines Kugelmodells werden die aus dem Experiment ableit-baren Größen der spezifischen Oberfläche und Porosität erläutert. Die experimen-tellen Ergebnisse konntne nachweisen, dass infiltrierten C/C Keramiken während einer oxidativen Belastung aufgrund des lokal unterschiedlichen Oxidationsverhal-tens eine ausgeprägte Kern Schale Struktur ausbilden.