The composite steel and concrete columns are known to have enhanced fire behaviour when compared with bare steel columns. However there are still aspects that must be clarified, as the influence of the building surrounding structure on the fire resistance of the columns. In this paper, the results of fire resistance tests on partially encased steel columns carried out with two different experimental systems are compared. In one of the experimental systems, the building surrounding structure is materialised by a steel restraining frame, and in the other is performed by the so-called substructuring method. Due to the concept of hybrid substructuring, the entire building is decomposed in two parts: one is represented by the building element under test, whereas the remaining building is simulated numerically in a computer. The main conclusion drawn from this work was that the surrounding structure has a major influence in the development of axial forces in the test columns. Moreover, it was observed that the higher the non-dimensional axial restraint ratio the lower the critical time of the columns.
Ausgehend von einer kritischen Analyse der Materialkennwerte für normalfesten (NFB) und hochfesten Beton (HFB) im Eurocode 2 wurden in grundlegenden Untersuchungen an der BAM exemplarisch für einen HFB die thermomechanischen Materialkennwerte bestimmt, um auf der Basis eines geeigneten Materialmodells das Verhalten von Stahlbetonstützen aus HFB unter Brandbeanspruchung zu simulieren. Die Validierung des Modells erfolgte mittels großmaßstäblicher Brandversuche an belasteten Stahlbetonstützen aus dem gleichen HFB wie in den Materialuntersuchungen. Es konnte gezeigt werden, dass die Festigkeit als charakteristischer Parameter des Materialmodells zwingend auf der Basis instationärer Versuche und nicht aus stationären Versuchen wie bei NFB üblich bestimmt werden muss. Mit den in vorgeschlagenen Materialbeziehungen für HFB wird das Tragverhalten der untersuchten Stützen dagegen deutlich überschätzt, was sich in den numerischen Simulationen insbesondere durch zu geringe Verformungen äußert.------------------------------------------------------------------------------------------------------
Development and Validation of an Advanced Calculation Model for High Strength Concrete Columns Subjected to Fire Loading
Following a critical analysis of the material parameters of normal strength (NSC) and high strength concrete (HSC) presented in Eurocode 2 the thermo-mechanical material parameters of one representative HSC were identified. Using these parameters and based on an appropriate material model the behavior of HSC columns was simulated. The validation of the model was realized through real scale fire resistance tests on loaded columns of the same type of HSC as in the material identification tests. It was found that the strength as a characteristic parameter of the material model has to be identified on the basis of transient creep tests and not of stationary tests, respectively as realized usually for NSC. It could be shown that the structural behavior of the tested columns is overestimated if the numerical simulations are based on the material properties of HSC as proposed in. This feature is expressed especially through insufficient displacements.