Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (32)
- Zeitschriftenartikel (22)
- Beitrag zu einem Tagungsband (20)
- Beitrag zu einem Sammelband (11)
- Posterpräsentation (4)
- Buchkapitel (2)
- Forschungsbericht (1)
Sprache
- Englisch (59)
- Deutsch (31)
- Französisch (2)
Schlagworte
- Fire resistance (9)
- Fire (6)
- Concrete (5)
- Fully developed fire (4)
- Constitutive equation (3)
- Creep (3)
- Fire stability (3)
- High temperature (3)
- Thermal restraint (3)
- Circular (2)
- Column (2)
- Columns (2)
- Composite steel-concrete columns (2)
- Concrete filled tube (CFT) column (2)
- Eurocode (2)
- Feuerwiderstand (2)
- Fire engineering (2)
- High performance concrete (2)
- High temperatures (2)
- Restraining (2)
- Restraining frame (2)
- Seismically damaged column (2)
- Steel (2)
- Stress-strain-relation (2)
- Substructuring method (2)
- UMAT (2)
- Weathering (2)
- 66Natural building stones (1)
- ABAQUS (1)
- Acoustic emission (1)
- Berechnungs- und Bemessungsverfahren (1)
- Brandschutz (1)
- Buckling (1)
- Carbon fiber reinforced polymer (CFRP) (1)
- Carbon fibre reinforced plastics CFRP (1)
- Carbon-fibre-reinforced (1)
- Carbon-fibre-reinforced plastics (1)
- Composite (1)
- Composites (1)
- Compressive strength (1)
- Computer supported testing (1)
- Concentrically braced steel frames (1)
- Constitutive model (1)
- Core materials (1)
- Damage location (1)
- Deformation theory of plasticity (1)
- Design temperatures (1)
- Dry film thickness (1)
- EC (1)
- Endochronic plasticity (1)
- Feuerwiderstandsdauer (1)
- Finite element analysis (1)
- Finite element method (1)
- Finite element model (1)
- Finite element simulation (1)
- Finite-Elemente-Methode (1)
- Fire Resistance (1)
- Fire after earthquake (1)
- Fire following earthquake (1)
- Fire performance (1)
- Fire protective coatings (1)
- Fire resistance period (1)
- Fire spalling (1)
- Fire testing (1)
- Gas pore pressure (1)
- Glass-fibre-reinforced plastics (1)
- High-Throughput Fire Tests (1)
- High-performance concrete (HPC) (1)
- High-temperature properties (1)
- Hochfester Beton (1)
- Hochleistungsbeton (1)
- Hybrid method (1)
- Hybrid testing (1)
- Hybride Versuchstechnik (1)
- Intermediate-scale test method (1)
- Intumescence (1)
- Intumescent coating (1)
- Intumescent coatings (1)
- Large scale tests (1)
- Large-scale tests (1)
- Mechanical testing (1)
- Mineral reactions (1)
- Modellierung (1)
- Multi-hazard incident (1)
- Nichtlineare Berechnungsverfahren (1)
- Normen (1)
- Normen/Vorschriften/Richtlinien (1)
- Numerical modelling (1)
- Numerical simulation (1)
- Ordinary concrete (1)
- Post-crash scenario (1)
- Post-earthquake fire (1)
- Pseudo-dynamic testing (1)
- Reaktive Brandschutzsysteme (1)
- Resistance (1)
- Spalling (1)
- Stahl (1)
- Standardised fire resistance tests (1)
- Steel beams and columns (1)
- Steel columns (1)
- Steel-concrete columns (1)
- Stickability (1)
- Structural integrity (1)
- Structural integrity investigation (1)
- Substructuring (1)
- Thermal Restraint (1)
- Thermal cracking (1)
- Thermal expansion (1)
- Thermal strain (1)
- Thermo mechanical stresses (1)
- Thermogravimetric analyses (1)
- Thermomechanical properties (1)
- Ultrasonic testing (1)
- Verformungsverhalten (1)
- Versuche (1)
- Viscoplasticity (1)
- composite (1)
- fire resistance (1)
- fire stability (1)
- intermediate-scale testing (1)
- sandwich panels (1)
- shells (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (32)
Thermal Restraint Effects on the Fire Resistance of Steel Composite Steel and Concrete Columns
(2009)
Thermal restraint effects on the fire resistance of steel and composite steel and concrete columns
(2009)
Thermal Restraint Effects on the Fire Resistance of Steel and Composite Steel and Concrete Columns
(2009)
In this study, a nonlinear three-dimensional finite element (FE) model was developed and validated to investigate the response of concrete filled tube (CFT) columns subjected to post-earthquake fires. Three steps were considered successively in the modelling, namely, cyclic, thermal and structural analyses. Outputs from the cyclic loading including residual deformationswere imposed as an initial condition to the thermal-stress model, imitating the seismic response of the column. Subsequently, a nonlinear sequentially thermal-stress analysis was conducted to simulate the fire response of column after the earthquake. The proposed FE model was validated by comparing the simulation resultswith the observations of full-scale fire and cyclic tests available in the literature.
The validated numericalmodelwas then used to study the behavior of CFT columns under the combined action of earthquake and fire as a multi-hazard event. Three probable seismic damage scenarios were considered in the column, namely, middle length, bottom and top end region damages. The level of damage was assumed as a high damage level, presuming that the column reached 50% of its lateral resistance while still maintaining ist overall stability after the earthquake. The results showed that the top and bottom end region damages have not significantly influence the fire response of the damaged column. Besides, the column with the middle span damage performed a lesser fire resistance time owing to the coincidence of damage location to that of onset of global buckling.
In this paper, a nonlinear three-dimensional finite element (FE) model was developed and validated to study the effect of seismic damage location on the response of concrete filled tube (CFT) columns at fire after earthquakes. Three analyses were conducted consecutively in the modelling, namely, cyclic, thermal and structural. Results of the cyclic loading analysis comprising residual deformations were applied as the Initial condition to the thermal-stress model, replicating the seismic performance of column.
Following, a nonlinear sequentially coupled-thermal stress Analysis was carried out to investigate the fire response of CFT columns after the seismic event. Three damage scenarios were contemplated, considering any possible potential damages that could be generated by the earthquake loading on CFT columns. The accuracy of the proposed FE model was examined by comparing the numerical results with that of available tests on fire and cyclic loading. By means of the validated model, the performance of damaged CFT columns was then investigated under fire after earthquakes. The level of damage was assumed as a high damage level, presuming that the column reached 50% of ist lateral resistance while still maintaining its overall stability after the earthquake. The results were presented broadly, including the axial deformation history as well as the fire resistance time for CFT columns. To have a comprehensive insight on the influence of damage location in columns, the fire response of damaged specimens was compared with that of an intact one.
Substrukturtechnik: Eine hybride Prüfmethode. Überblick mit Anwendung im Brandingeniueurwesen
(1999)
Substrukturtechnik - eine hybride Prüfmethode ; Überblick mit Anwendung im Brandingenieurwesen
(1999)
A test set-up in intermediate scale was conceived to investigate the structural integrity of materials under fire. The task was to develop a realistic test scenario targeting component-like behaviour. Carbon-fibre-reinforced sandwich specimens (500 X 500 X 20 mm) were used to examine failure mechanisms, times to failure and critical failure loads under compression. Fire tests were performed with fully developed fire applied to one side of the specimen by an oil burner. In a first test series, the applied load was varied, but the fully developed fire remained unchanged. In general, times to failure were short. Decreased load levels resulted in prolonged times to failure and led to a different failure mechanism. Results obtained in the test series were compared with a bench-scale study (150 X 150 X 20 mm) investigating identical material. The comparison clearly revealed the influence of size on the time to failure and the load-bearing capacity.
The recommendation is based on the co-authors’ work organized by the RILEM TC 256-SPF “Spalling of concrete due to fire: testing and modelling”. It aims to provide useful information, guidance and best practices in fire spalling assessment to laboratories that perform large-scale tests based on fire resistance test standards. It provides guidance on the spalling observation techniques during testing, as well as post-test spalling quantification/assessment methods. This document is intended to be used in conjunction with the fire resistance test standards, e.g. EN 1363-1 and ISO 834-1.
The fire behaviour of light-weight material used in structural applications is regarded as the main challenge to be solved for mass transportation. The task is to perform realistic experiments, including a mechanical test scenario under fully developed fires, to improve the material's reliability in structural applications. Our approach utilises an intermediate-scale test set-up (specimen size 500 × 500 mm) to apply realistic compressive loads and fully developed fires directly to one side of a carbon-fibre-reinforced sandwich composite. Three different intumescent coatings were applied to sandwich structures and compared to a bench-scale study. The results emphasise intumescent coatings as a promising method to sustain fire resistance, multiplying the time to failure. Nevertheless, the realistic intermediate-scale test using severe direct flame application underlines the extremely short failure times when the actual composite components are tested without any additional insulation.
For the evaluation of the fire resistance time of structural elements thermal and mechanical loadings are applied to the specimen. Up to now the monitored data is represented in tabular form and simple plots. In the following a visualization system to show the data in its geometrical context is discussed.
Notes sur un nouveau modèle de matériau représentant un comportement viscoélastique-plastique
(1985)
Monitoring of fire damage processes in concrete by pore pressure and acoustic emission measurements
(2011)
This paper presents the combined use of acoustic emission (AE), gas pore pressure and temperature measurements (PT). The simultaneous application of both techniques represents a new methodology in the context of fire spalling and contributes to a better understanding of the mechanisms of fire spalling, particular with regard to the interaction of micro cracking and pore pressure evolution. The study presents fire tests on normal strength concrete specimens with and without reinforcement at ISO Standard fire and at hydrocarbon (HC) fire. Supported by AE-analysis, it can be shown that due to the higher heating rate of the HC-fire in comparison to the ISO Standard fire the damage processes inside the concrete during the exposure are increased combined with augmenting the concrete permeability. As a consequence lower pore pressures were measured. However, despite the lower pore pressures, explosive spalling was observed.
Isotrope nichtlineare Viskoelastizität mit Hilfe von Maßstabsfunktionen der Gedächtnisspannung
(1993)
Isotrope nichtlineare Viskoelastizität mit Hilfe von Maßstabsfunktionen der Gedächtnisspannung
(1994)
Originally introduced in the field of earthquake engineering hybrid testing, i.e. the simultaneous combined application of numerical simulation techniques and execution of experiments, is nowadays used in different areas of experimental analysis. The focus of this paper is on the presentation of the so-called substructuring method as a hybrid method in fire engineering. Motivation are EU standards for fire resistance tests of columns or beams. According to these codes building elements are considered as stand-alone elements whereas in real fires each building element interacts with its adjacent elements. Therefore, to conduct a fire test in a more realistic fashion, the concept of hybrid substructuring as a special experimental technique has been adopted to fire engineering. Due to this concept the entire building, which is exposed to a real fire, is decomposed into two parts. One part is represented by the building element under test in a special furnace, whereas the remaining building environment is simulated by a model, based on the equations of thermomechanics. The paper addresses the historical development of the substructuring method in fire engineering supplemented by presentation of the results of realized fire resistance tests in substructuring mode on different types of specimens.
High-throughput fire tests and weathering-induced degradation behaviour of intumescent coatings
(2018)
In this work, the weathering-induced degradation of intumescent coatings was investigated by a systematic and comprehensive approach. A mechanism is revealed that is proposed to be responsible for the loss of function of intumescent coatings induced by weathering.
First, the thermal decomposition of artificially weathered intumescent coatings was examined. To get a better understanding of the weathering and ageing phenomena, the degradation behaviour of the single ingredients during the weathering process was investigated, as well as their chemical and physical interactions. For the systematic approach, the materials that are essential for intumescence (ammonium polyphosphate, pentaerythritol, titanium dioxide, melamine and the binder) are treated with moisture, elevated temperature and UV radiation.
Thermogravimetry (TG) and IR spectroscopy were used to compare the initial samples with their different grades of weathering. We demonstrate that ammonium polyphosphate, melamine and the binder are mainly responsible for the ageing process. Further, it was demonstrated that TG and IR spectroscopy are suitable measuring methods to detect the effects of weathering on intumescent coatings.
Finally, a small-scale fire test procedure is introduced. Based on the reduction of the sample size, up to 50 samples can be tested in a single fire test. The results of this fire test have the same quality as the results from standard intermediate fire tests corresponding to DIN 4102-8.
Fire stability of glass-fibre sandwich panels: The influence of core materials and flame retardants
(2017)
Fire resistance has become a key property for structural lightweight sandwich components in aviation, shipping, railway vehicles, and construction. The development of future composite materials and components demands adequate test procedures for simultaneous application of compression and fully developed fire. Therefore an intermediate-scale approach (specimen size = 500 mm x 500 mm) is applied with compressive loads (up to 1 MN) and direct application of a burner to one side of the specimens, as established in aviation for severe burn-through tests. The influence of different core structures (polyvinylchloride foam, polyisocyanorate foam reinforced by stitched glass bridges, and balsa wood) was investigated for glass-fibre-reinforced sandwich specimens with and without flame retardants applied on the fabrics, in the matrix, and on surface for each specimen at the same time. Times to failure were increased up to a factor of 4. The intumescent coating prolongs the time to failure significantly.
What is more, using the intrinsic potential of the front skin together with the core to protect a load bearing back skin in sandwich panels, the design of the core – here using the wood core – is the most promising approach.
The fire stability of carbon fiber reinforced polymer (CFRP) shell structures was investigated using an intermediate-scale test setup. The shell specimens are representative of typical load-bearing CFRPs in modern civil aviation. The CFRP shell specimens were exposed to a fully developed fire with direct flame impingement to one side at a heat flux of 182 kW/m2. Specimens were simultaneously loaded with constant compressive force equal to 40% of the ultimate failure load. CFRP shells and four different fire retarding configurations, using integrated protective layers, were investigated. Unprotected CFRP specimens failed after just 27 s. Specimens with integrated protective layers with low heat conductivity and high burn-through resistance showed the most promising results. An integrated titanium foil decelerated the decomposition of the epoxy matrix and increased the time to failure by 68% compared to the unprotected CFRP shell.