Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (32)
- Zeitschriftenartikel (24)
- Beitrag zu einem Tagungsband (22)
- Beitrag zu einem Sammelband (9)
- Posterpräsentation (4)
- Buchkapitel (2)
- Forschungsbericht (1)
Sprache
- Englisch (61)
- Deutsch (31)
- Französisch (2)
Schlagworte
- Fire resistance (9)
- Concrete (6)
- Fire (6)
- Fully developed fire (4)
- High temperature (4)
- Constitutive equation (3)
- Creep (3)
- Fire stability (3)
- Thermal restraint (3)
- Circular (2)
Organisationseinheit der BAM
Eingeladener Vortrag (wissenschaftliche Konferenzen)
- nein (32)
Most of the previous studies on reinforced concrete columns with elastically restrained thermal elongation were carried out on square, rectangular or '+'-shaped cross sections. The number of fire resistance tests on circular reinforced concrete columns with elastically restrained thermal elongation is still very small. In order to examine the influence of several parameters on the behaviour in fire of this type of columns several fire resistance tests were carried out. The parameters tested were the load and restraint level, slenderness of the column and longitudinal reinforcement ratio. In the fire resistance tests the specimens were exposed to the ISO 834 standard fire curve and the critical time (fire resistance) and temperature and failure modes were determined. The test results showed that the spalling phenomenon may occur in circular columns and so reducing its fire resistance. The increasing of the load level led to a reduction while the increasing of the longitudinal reinforcement ratio or the decreasing of the slenderness of the columns led to an increasing of their fire resistance. The restraint level might not be much relevant on the fire resistance of circular reinforced concrete columns.
The EQUFIRE project aims to study the post-earthquake fire Performance of steel frame structures and is part of the Transnational Access activities of the SERA project (www.sera-eu.org) at the ELSA Reaction Wall of the European Commission - Joint Research Centre. As it has happened in many historical occasions, after an earthquake, earthquakeinduced rupture of gas piping, failure of electrical systems, etc. may trigger fire. The structural fire performance can deteriorate because the fire acts on a previously damaged structure. In addition, the earthquake may have damaged fire protection elements and the fire can spread more rapidly if compartmentation walls have failed. This is particularly relevant for steel structures as the high thermal conductivity of elements with small thickness entails quick temperature rise with consequent fast loss of strength and stiffness.
EQUFIRE studied a four-storey three-bay steel frame with concentric bracings in the central bay. The structure was designed for reference peak ground acceleration equal to 0.186g, soil type B and type 1 elastic response spectrum according to Eurocode 8. Tests were performed at the ELSA Reaction Wall and at the furnace of the Federal Institute for Materials Research and Testing (BAM).
The experimental activities at the ELSA Reaction Wall comprise pseudo-dynamic tests on a full-scale specimen of the first storey of the building, while the upper three storeys are numerically simulated. The aim is to study the response of the structure and fire protection elements, including their interaction, under the design earthquake and for different configurations: bare frame without fire protection, specimen with three fire protection solutions (conventional and seismic-resistant boards, and vermiculite sprayed coating) applied on the bracing and one column, and with conventional and seismic-resistant fire barrier walls built in the two external bays of the specimen. The testing programme at BAM included fire tests of five columns (two specimens without fire protection elements and three specimens with the types of fire protection mentioned above). Before the fire test, each column was subjected to a horizontal and vertical displacement history resulting from the seismic action. During the fire tests, the effect of the surrounding structure was simulated by limiting the axial thermal expansion.
The experimental results will serve to study the response of structural and non-structural components to fire following earthquake scenarios, with a view to improving existing design guidelines and future standards.
Originally introduced in the field of earthquake engineering hybrid testing, i.e. the simultaneous combined application of numerical simulation techniques and execution of experiments, is nowadays used in different areas of experimental analysis. The focus of this paper is on the presentation of the so-called substructuring method as a hybrid method in fire engineering. Motivation are EU standards for fire resistance tests of columns or beams. According to these codes building elements are considered as stand-alone elements whereas in real fires each building element interacts with its adjacent elements. Therefore, to conduct a fire test in a more realistic fashion, the concept of hybrid substructuring as a special experimental technique has been adopted to fire engineering. Due to this concept the entire building, which is exposed to a real fire, is decomposed into two parts. One part is represented by the building element under test in a special furnace, whereas the remaining building environment is simulated by a model, based on the equations of thermomechanics. The paper addresses the historical development of the substructuring method in fire engineering supplemented by presentation of the results of realized fire resistance tests in substructuring mode on different types of specimens.
In this paper, a nonlinear three-dimensional finite element (FE) model was developed and validated to study the effect of seismic damage location on the response of concrete filled tube (CFT) columns at fire after earthquakes. Three analyses were conducted consecutively in the modelling, namely, cyclic, thermal and structural. Results of the cyclic loading analysis comprising residual deformations were applied as the Initial condition to the thermal-stress model, replicating the seismic performance of column.
Following, a nonlinear sequentially coupled-thermal stress Analysis was carried out to investigate the fire response of CFT columns after the seismic event. Three damage scenarios were contemplated, considering any possible potential damages that could be generated by the earthquake loading on CFT columns. The accuracy of the proposed FE model was examined by comparing the numerical results with that of available tests on fire and cyclic loading. By means of the validated model, the performance of damaged CFT columns was then investigated under fire after earthquakes. The level of damage was assumed as a high damage level, presuming that the column reached 50% of ist lateral resistance while still maintaining its overall stability after the earthquake. The results were presented broadly, including the axial deformation history as well as the fire resistance time for CFT columns. To have a comprehensive insight on the influence of damage location in columns, the fire response of damaged specimens was compared with that of an intact one.
In this study, a nonlinear three-dimensional finite element (FE) model was developed and validated to investigate the response of concrete filled tube (CFT) columns subjected to post-earthquake fires. Three steps were considered successively in the modelling, namely, cyclic, thermal and structural analyses. Outputs from the cyclic loading including residual deformationswere imposed as an initial condition to the thermal-stress model, imitating the seismic response of the column. Subsequently, a nonlinear sequentially thermal-stress analysis was conducted to simulate the fire response of column after the earthquake. The proposed FE model was validated by comparing the simulation resultswith the observations of full-scale fire and cyclic tests available in the literature.
The validated numericalmodelwas then used to study the behavior of CFT columns under the combined action of earthquake and fire as a multi-hazard event. Three probable seismic damage scenarios were considered in the column, namely, middle length, bottom and top end region damages. The level of damage was assumed as a high damage level, presuming that the column reached 50% of its lateral resistance while still maintaining ist overall stability after the earthquake. The results showed that the top and bottom end region damages have not significantly influence the fire response of the damaged column. Besides, the column with the middle span damage performed a lesser fire resistance time owing to the coincidence of damage location to that of onset of global buckling.
In klassischen Feuerwiderstandsprüfungen wird die Tragfähigkeit eines einzelnen Tragwerkselementes (z. B. Stütze) unter Feuereinwirkung bestimmt. In realen Brandsituationen interagieren jedoch brandbeanspruchte Bauteile eines Gebäudes immer mit dem angrenzenden Tragwerk. Für eine genauere Bewertung der Tragfähigkeit werden deshalb spezielle experimentelle Methoden benötigt, die eine Interaktion zwischen geprüftem Bauteil und Tragwerk in Feuerwiderstandsprüfungen berücksichtigen.
Zur Umsetzung dieses Anspruchs konnte in Kooperation mit dem Joint Research Centre (JRC) in Ispra, Italien, die bereits im Erdbebeningenieurwesen eingesetzte Substrukturmethode erfolgreich zur innovativen Nutzung des Stützenprüfofens der BAM portiert werden. Nach dieser Methode wird das gesamte Gebäude in zwei Teile zerlegt: Ein Teil entspricht dem zu prüfenden Bauteil, während der Rest des Gebäudes online durch ein analytisches oder numerisches Modell simuliert wird.
Im Vortrag werden entsprechende Ergebnisse zahlreicher Experimente neben Erläuterungen zu Hard- und Software präsentiert. Abschließend werden weitere Forschungsaktivitäten des Fachbereiches Brandingenieurwesen vorgestellt.
The recommendation is based on the co-authors’ work organized by the RILEM TC 256-SPF “Spalling of concrete due to fire: testing and modelling”. It aims to provide useful information, guidance and best practices in fire spalling assessment to laboratories that perform large-scale tests based on fire resistance test standards. It provides guidance on the spalling observation techniques during testing, as well as post-test spalling quantification/assessment methods. This document is intended to be used in conjunction with the fire resistance test standards, e.g. EN 1363-1 and ISO 834-1.
The recommendation is based on the coauthors’ work organized by the RILEM TC 256-SPF ‘‘Spalling of concrete due to fire: testing and modelling’’. The Committee has defined two types of screening tests for characterization of concrete propensity to fire spalling: Material screening tests and Product screening tests. Definitions of both types of tests are given in the paper. The following recommendations apply to Material screening tests. The material screening tests described in these recommendations are a set of minimum requirements to test concrete spalling propensity (for example, the minimal specimen size). This document covers the aspects of concrete characterization, specimen geometries, storage conditions, test methods and measured parameters.
The phenomenon of creep of structural steel in fire engineering is gaining more and more interest. Due to shortcomings of the EC3 constitutive model and other approaches based on classical creep theory an alternative approach mainly based on the ideas of Krempl is proposed. Due to this so-called operator approach the material as well as the constitutive model is looked upon as an operator. The application of this view serves as a guide through the analysis of the relationship between experimental facts and constitutive theory especially in the context of transient creep.