Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (15)
- Beitrag zu einem Tagungsband (4)
- Monografie (1)
- Beitrag zu einem Sammelband (1)
- Sonstiges (1)
- Forschungsbericht (1)
Schlagworte
- Computed tomography (3)
- Osteoporotic vertebral fracture (3)
- Bone regeneration (2)
- Cr(III) (2)
- Crystal (2)
- Distributed acoustic sensing (2)
- Distributed fiber optic sensing (2)
- Large animal model (2)
- Large animal model sheep (2)
- NIR (2)
- Reliability (2)
- Sensor (2)
- Upconversion (2)
- Vertebroplasty (2)
- Yb(III) complex (2)
- Acoustics (1)
- Air-coupled ultrasound (1)
- Artificial neural networks (1)
- Automotive engineering (1)
- Berechnungs- und Bemessungsverfahren (1)
- Bestandssicherung und Erhaltung (1)
- Beton (1)
- Biocides (1)
- Biodeterioration (1)
- Bone marrow extrusion (1)
- Bone morphogenetic protein; (1)
- Bone regeneration; (1)
- Brushite-forming calcium phosphate cement (1)
- Calcium phosphat cement (1)
- Calcium phosphate cement (1)
- Calcium phosphate cement; (1)
- Cement injection (1)
- Ceramics (1)
- Characterization (1)
- Charakterisierung (1)
- Consequence (1)
- DAS (1)
- Damage (1)
- Direct (1)
- Direkt (1)
- Elastodynamic Finite Inegration Technique (1)
- Entwurf und Konstruktion (1)
- Ex vivo (1)
- Failure (1)
- Flame retardancy (1)
- Flammability (1)
- GDF-5 mutant; (1)
- Guideline (1)
- Halogen free (1)
- Halogen‐free (1)
- High- viscosity PMMA cement (1)
- Hängebrücke (1)
- IBRG (1)
- In vivo (1)
- Indirect (1)
- Indirekt (1)
- Konsequenz (1)
- Lanthanide (1)
- Large animal model sheep; (1)
- Lebenszyklus (1)
- Life-cycle (1)
- Lifetime (1)
- Light harvesting (1)
- Lunar regolith (1)
- Lutgekoppelte Ultraschallprüfung (1)
- Micro-Computed-Tomography; (1)
- Microstructure (1)
- Minimal-invasive (1)
- Model approach (1)
- Modellansatz (1)
- Monitoring (1)
- Multicomponent systems (1)
- NDT-CE (1)
- Non-Destructive Testing (1)
- PLGA cement (1)
- Photoluminescence (1)
- Photophysics (1)
- Polymer (1)
- Polymer dispersions (1)
- Polypropylene (1)
- Probability of Detection (1)
- Probe (1)
- Prüfkopf (1)
- Quality (1)
- Qualität (1)
- Qualitätssicherung (1)
- Quantum yield (1)
- Richtlinie (1)
- Risikoanalyse (1)
- Risk assessment (1)
- SAFT (1)
- SAXS (1)
- Schaden (1)
- Sensitization (1)
- Sheep (1)
- Sintering (1)
- Small-angle X-ray scattering (1)
- Softening temperature (1)
- Structural Health Monitoring (1)
- Survey (1)
- Suspension bridge (1)
- Test method (1)
- Train monitoring (1)
- Train tracking (1)
- Triplet-triplet annihilation (1)
- Ultraschall-Echo (1)
- Ultrasonic Guided Waves (1)
- Ultrasonic echo (1)
- Ultrasonic testing (1)
- Versagen (1)
- Vertebral (1)
- Void defect (1)
- Wood plastic composite (1)
- Wood plastic composite (WPC) (1)
- Zerstörungsfreie Prüfung (1)
- µCT (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (8)
- 8.4 Akustische und elektromagnetische Verfahren (4)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.2 Biophotonik (2)
- 7 Bauwerkssicherheit (2)
- 8.6 Faseroptische Sensorik (2)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 7.4 Baustofftechnologie (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
This guideline was drafted following and complementing the norm ISO 22232-2:2020(E) to include air-coupled ultrasonic transducers. This document specifies the characteristics of probes used for non-destructive air-coupled ultrasonic testing with center frequencies above 20 kHz, with focusing or without focusing means.
Zur Charakterisierung von luftgekoppelten Ultraschallwandlern werden mehrere verschiedene Methoden und Verfahren angewendet. Durch die unterschiedlichen Herangehensweisen werden oft unterschiedliche Prüfkopfpara-meter und Schallfeldgrößen ermittelt, was einen direkten Vergleich von Datenblättern erschwert. Für die Charakterisierung von Kontakt- und Tauchtechnikprüfköpfen hat sich ISO 22232-2:2021 bereits etabliert, allerdings ist diese Norm nicht auf die luftgekoppelten Wandlertechnologien direkt übertragbar. Daher erkannten Hersteller, Forschungseinrichtungen und Anwender den Bedarf an einer Richtlinie zur einheitlichen Charakterisierung von luftgekoppelten Wandlern. Gemeinsam arbeiten sie aktuell im Rahmen des Unterausschusses „Luftgekoppelte Ultraschallprüfung“ der DGZfP an der Erstellung einer solcher Richtlinie mit dem Anspruch, die bestehende Normung um die luftgekoppelte Prüfung zu erweitern und somit die Vereinheitlichung der Charakterisierung dieser Wandler zu erleichtern.
In diesem Beitrag wird ein Überblick über den geplanten Inhalt der Richtlinie und über die Methoden zur akustischen Charakterisierung von luftgekoppelten Ultraschallwandlern gegeben. Insbesondere werden verschiedene Methoden der Ermittlung von wichtigen Wandlerparametern wie z.B. Empfindlichkeit, Mittenfrequenz, Bandbreite, Fokusgröße und Fokusabstand dargestellt und verglichen.
In many industrial sectors, Structural Health Monitoring (SHM) is considered as an addition to Non-Destructive Testing (NDT) that can reduce maintenance effort during lifetime of a technical facility, structural component or vehicle. A large number of SHM methods is based on ultrasonic waves, whose properties change depending on structural health. However, the wide application of SHM systems is limited due to the lack of suitable methods to assess their reliability. The evaluation of the system performance usually refers to the determination of the Probability of Detection (POD) of a test procedure. Up to now, only few limited methods exist to evaluate the POD of SHM systems, which prevent them from being standardised and widely accepted in industry. The biggest hurdle concerning the POD calculation is the large amount of samples needed. A POD analysis requires data from numerous identical structures with integrated SHM systems. Each structure is then damaged at different locations and with various degrees of severity. All of this is connected to high costs. Therefore, one possible way to tackle this problem is to perform computer-aided investigations. In this work, the POD assessment procedure established in NDT according to the Berens model is adapted to guided wave-based SHM systems. The approach implemented here is based on solely computer-aided investigations. After efficient modelling of wave propagation phenomena across an automotive component made of a carbon fibre-reinforced composite, the POD curves are extracted. Finally, the novel concept of a POD map is introduced to look into the effect of damage position on system reliability.
Vertebroplasty or kyphoplasty of osteoporotic vertebral fractures bears the risk of pulmonary cement embolism (3.5%–23%) caused by leakage of commonly applied acrylic polymethylmethacrylate (PMMA) cement to spongious bone marrow or outside of the vertebrae. Ultraviscous cement and specific augmentation systems have been developed to reduce such adverse effects. Rapidly setting, resorbable, physiological calcium phosphate cement (CPC) may also represent a suitable alternative.
PURPOSE: This study aimed to compare the intravertebral extrusion of CPC and PMMA cement in an ex vivo and in vivo study in sheep.
STUDY DESIGN/SETTING: A prospective experimental animal study was carried out. METHODS: Defects (diameter 5 mm; 15 mm depth) were created by a ventrolateral percutane-ous approach in lumbar vertebrae of female Merino sheep (2–4 years) either ex vivo (n = 17) or in vivo (n = 6), and injected with: (1) CPC (L3); (2) CPC reinforced with 10% poly(l-lactide-co-glycolide) (PLGA) fibers (L4); or (3) PMMA cement (L5; Kyphon HV-R). Controls were untouched (L1) or empty defects (L2). The effects of the cement injections were assessed in vivo by blood gas analysis and ex vivo by computed tomography (CT), micro-CT (voxel size: 67 µm), histology, and biomechanical testing.
Healable materials could play an important role in reducing the environmental footprint of our
modern technological society through extending the life cycles of consumer products and constructions. However, as most healing processes are carried out by heat alone, the ability to heal damage generally kills the parent material’s thermal and mechanical properties. Here we
present a dynamic covalent polymer network whose thermal healing ability can be switched ‘on’ and ‘off’ on demand by light, thereby providing local control over repair while retaining the advantageous macroscopic properties of static polymer networks. We employ a photoswitchable furan-based crosslinker, which reacts with short and mobile maleimidesubstituted poly(lauryl methacrylate) chains forming strong covalent bonds while simultaneously allowing the reversible, spatiotemporally resolved control over thermally induced de- and re-crosslinking. We reason that our system can be adapted to more complex materials and has the potential to impact applications in responsive coatings, photolithography and microfabrication.
Developing halogen‐free flame retardants with reasonably high efficiency, which thus function at limited loadings in polypropylene‐based wood/plastic composites (WPC), is still a challenge. Cost‐effective flame‐retarded WPC have been identified as a way to open the door to an interesting, broader spectrum of application in the building and transportation sectors. This work imparts a systematic comprehensive understanding and assessment of different basic routes to halogen‐free flame‐retarded WPC, taking into account economic and environmental considerations. Cheap, halogen‐free single‐component flame retardants and their multicomponent systems are investigated at reasonable filling grades of 20 wt%. The basic routes of promising synergistic multicomponent systems are discussed, and their potential and Limits assessed. Optimizing the consistency of fire residue; closing the surface of inorganic‐organic residual layers; the thermal stabilization and design of the residue, eg, synergistic combination of ammonium polyphosphate and expandable graphite; and the combination of different flame‐retardant mechanisms, eg, intumescence and flame inhibition, are proposed as promising routes to boost the flame‐retardant efficiency.
Ziel des vorliegenden Beitrages ist es, einen Überblick über die aktuellen Entwicklungen im Bereich der Bewertung und der Quantifizierung der Robustheit von Bauwerken zu geben. In diesem Sinne ist eine Zusammenstellung von Ansätzen und Ergebnissen aktueller Veröffentlichungen enthalten. Ein umfassender entscheidungstheoretischer Ansatz für die Berechnung und das Management der Robustheit wird vorgestellt. Dieser beinhaltet die Definition der Robustheit als eine Qualität eines Systems, welches das Bauwerk beinhaltet, d. h. eine Qualität, die auf der Grundlage einer Risikoanalyse bewertet werden kann. Um eine umfassende Risikoanalyse zu ermöglichen, wird ein szenarienbasierter Modellansatz eingeführt, welcher zwei Arten von Konsequenzen im System unterscheidet: direkte Konsequenzen (in Verbindung mit Schäden einzelner Komponenten des Systems) und indirekte Konsequenzen (in Verbindung mit einem Versagen des Systems). Die Definition des Systems spielt deshalb für die Risikoanalyse eine wichtige Rolle, und es wird diskutiert, wie die Robustheit für verschiedene Definitionen zu unterschiedlichen Ergebnissen und Erkenntnissen im Sinne des Managements der Integrität des Bauwerks im gesamten Lebenszyklus unter Berücksichtigung seiner Funktionalität führt. Weiterhin werden wichtige Aspekte der Standardisierung der Robustheitsanalyse, wie auch Anforderungen an die Robustheit, diskutiert und Vorschläge zum Umgang mit diesen Aspekten unterbreitet. Auf der Grundlage der vorgestellten Ansätze zur Berechnung der Robustheit eines Bauwerks wird beschrieben, wie Entscheidungen in Bezug auf den Entwurf, die Zustandsbewertung, auf Inspektionen und Wartung sowie in Bezug auf die Überwachung von Bauwerken, in Hinblick auf das Management der Risiken in allen Phasen des Lebenszyklus, optimiert werden können.
Large animal models are highly recommended for meaningful preclinical studies, including the optimization of cement augmentation for vertebral body defects by vertebroplasty/kyphoplasty.
The aim of this study was to perform a systematic characterization of a strictly minimally invasive in vivo large animal model for lumbar ventrolateral vertebroplasty.
This is a prospective experimental animal study.
Lumbar defects (diameter 5 mm; depth approximately 14 mm) were created by a ventrolateral percutaneous approach in aged, osteopenic, female sheep (40 Merino sheep; 6–9 years; 68–110 kg). L1 remained untouched, L2 was left with an empty defect, and L3 carried a defect injected with a brushite-forming calcium phosphate cement (CPC). Trauma/functional impairment, surgical techniques (including drill sleeve and working canula with stop), reproducibility, bone defects, cement filling, and functional cement augmentation were documented by intraoperative incision-to-suture time and X-ray, postoperative trauma/impairment scores, and ex vivo osteodensitometry, microcomputed tomography (CT), histology, static/fluorescence histomorphometry, and biomechanical testing.
Minimally invasive vertebroplasty resulted in short operation times (28±2 minutes; mean±standard error of the mean) and X-ray exposure (1.59±0.12 minutes), very limited local trauma (score 0.00±0.00 at 24 hours), short postoperative recovery (2.95±0.29 hours), and rapid decrease of the postoperative impairment score to 0 (3.28±0.36 hours). Reproducible defect creation and cement filling were documented by intraoperative X-ray and ex vivo conventional/micro-CT. Vertebral cement augmentation and osteoconductivity of the CPC was verified by osteodensitometry (CPC>control), micro-CT (CPC>control and empty defect), histology/static histomorphometry (CPC>control and empty defect), fluorescence histomorphometry (CPC>control; all p<.05 for 3 and 9 months), and compressive strength measurements (CPC numerically higher than control; 102% for 3 months and 110% for 9 months).
This first-time systematic clinical assessment of a minimally invasive, ventrolateral, lumbar vertebroplasty model in aged, osteopenic sheep resulted in short operation times, rapid postoperative recovery, and high experimental reproducibility. This model represents an optimal basis for standardized evaluation of future studies on vertebral augmentation with resorbable and osteoconductive CPC.
Ultrasonic imaging systems usually require an array of ultrasonic transducers for data acquisition on a wide area on top of an object under investigation. The goal of an imaging algorithm is the use of reflected ultrasound data to form a recognizable image. Conventional algorithms like SAFT are based on an inverse Huygens' principle and need therefore a dense measurement grid. This requires a big effort in data capturing. For simple and inexpensive measurement different strategies of imaging with reduced amount of data and examples with a manual scanning device on concrete elements are presented.
BACKGROUND CONTEXT: Targeted delivery of osteoinductive bone morphogenetic Proteins (eg, GDF5) in bioresorbable calcium phosphate cement (CPC), potentially suitable for vertebroplasty and kyphoplasty of osteoporotic vertebral fractures, may be required to counteract augmented local bone catabolism and to support complete bone regeneration. The biologically optimized GDF5 Mutant BB-1 may represent an attractive drug candidate for this purpose.
PURPOSE: The aim of the current study was to test an injectable, poly (l-lactide-co-glycolide) acid (PLGA) fiber-reinforced, brushite-forming CPC containing low-dose BB-1 in a sheep lumbar osteopenia model.
STUDY DESIGN/ SETTING: This is a prospective experimental animal study.
METHODS: Bone defects (diameter 5 mm) were generated in aged, osteopenic female sheep and were filled with fiber-reinforced CPC alone (L4; CPC+fibers) or with CPC containing different dosages.
Der Fachbereich 8.2 der Bundesanstalt für Materialforschung und -prüfung (BAM) hat eine innovative Methode zur zerstörungsfreien Ultraschallprüfung erarbeitet und den technischen Aufbau in Form eines neuen Gerätes entwickelt. Mit Hilfe des Produktdesigns soll die Etablierung auf dem Markt sichergestellt werden.
Die Arbeit erläutert detailliert die Bereiche, die für die Gestaltung des Handscangerätes von Bedeutung sind. Sie befasst sich mit der Installation und Handhabung des Systems am Einsatzort und beleuchtet wichtige technische Details. Der nicht verkleidete technische Aufbau der zwei neu entwickelten Geräte dient als Grundlage für die Erarbeitung eines Gehäusekonzepts. Neben dem Gehäusedesign wird eine Überarbeitung des gesamten Aufbaus durchgeführt, um die Benutzerfreundlichkeit in verschiedenen Punkten zu verbessern. Zukünftige Designentscheidungen werden auf Grundlage von praxisnahen Beobachtungen und der notwendigen Anordnung der technischen Komponenten getroffen. Ziel der Auseinandersetzung ist es, ein funktionelles und ästhetisch ansprechendes Design zu entwickeln. Am Ende sollen unter Beachtung aller Vorgaben die Ergebnisse dieser Arbeit zu einem ergonomischen Gerät führen.
Die Problemstellung besteht daraus, den komplexen technischen Vorgaben und Ansprüchen des Projektpartners und Innovationsgebers gerecht zu werden und gleichzeitig ein gutes Designziel zu erreichen. Das Design soll die Funktionalität und Handhabung des Gerätes verbessern und dient als Hilfsmittel, um den komplexen Aufbau zu vereinfachen. Die Benutzerfreundlichkeit soll an allen nötigen Stellen verbessert werden und ein ästhetisch zusammenstehender Gesamteindruck soll entstehen, ohne die Funktionalität negativ zu beeinflussen.
Upconversion photoluminescence in hetero-oligonuclear metal complex architectures featuring organic ligands is an interesting but still rarely observed phenomenon, despite its great potential from a basic research and application perspective. In this context, a new photonic material consisting of molecular chromium(III) and ytterbium(III) complex Ions was developed that exhibits excitation-power density-dependent cooperative sensitization of the chromium-centered 2E/2T1 phosphorescence at approximately 775 nm after excitation of the ytterbium band 2F7/2!2F5/2 at approximately 980 nm in the solid state at ambient temperature. The upconversion process is insensitive to atmospheric oxygen and can be observed in the presence of water molecules in the crystal lattice.
Issues that prevent Structural Health Monitoring (SHM) based on Guided Waves (GW) from being a part of today’s monitoring solutions in industry are not all obvious to the scientific community. To uncover and overcome these issues, scientists working on SHM and GW problems joined in an expert committee under the patronage of the German Society for Non-Destructive Testing. An initiated online survey among more than 700 experts and users reveals the hurdles hindering the practical application of GWbased SHM. Firstly, methods for proof of reliability of SHM approaches are missing.
Secondly, detailed understanding of phenomenological described wave-damage interactions is needed. Additionally, there are significant unsolved implementation issues and unsolved problems of signal processing including handling of environmental influences.
To enable substantial proof of reliability without unaffordable experimental effort also efficient simulation tools including realistic damage interaction are needed, enabling the joint use of experimental and simulated data to predict the capabilities of the Monitoring system. Considering these issues, the committee focusses on simulation, signal processing, as well as probability of detection and standardization. In the presented work, recent activities of the expert committee starting with survey results are summarized. An open access data basis of life-like measurements is presented to allow testing and comparison of signal processing and simulation algorithms. Finally, a strategy for efficient proof of reliability increasing the acceptance of SHM in industry and for successful Integration of SHM into real-world engineering structures is proposed.
Distributed acoustic sensing (DAS) over tens of kilometers of fiber optic cables is well-suited for monitoring extended railway infrastructures. As DAS produces large, noisy datasets, it is important to optimize algorithms for precise tracking of train position, speed, and the number of train cars, The purpose of this study is to compare different data analysis strategies and the resulting parameter uncertainties. We present data of an ICE 4 train of the Deutsche Bahn AG, which was recorded with a commercial DAS system. We localize the train signal in the data either along the temporal or spatial direction, and a similar velocity standard deviation of less than 5 km/h for a train moving at 160 km/h is found for both analysis methods, The data can be further enhanced by peak finding as well as faster and more flexible neural network algorithms. Then, individual noise peaks due to bogie clusters become visible and individual train cars can be counted. From the time between bogie signals, the velocity can also be determined with a lower standard deviation of 0.8 km/h, The analysis methods presented here will help to establish routines for near real-time Train tracking and train integrity analysis.
Photonen-Aufkonvertierung in hetero-oligonuklearen, Metallkomplex-Architekturen mit organischen Liganden ist ein interessantes, aber bisher selten beobachtetes Phänomen, trotz des großen Potentials sowohl aus Sicht der Grundlagenforschung als auch aus der Anwendungsperspektive. Nun wurde ein neues photonisches Material aus molekularen Chrom(III)- und Ytterbium(III)-Komplexionen entwickelt.
Dieses zeigt im Festkörper bei Raumtemperatur abhängig von der Anregungsleistungsdichte nach Anregung des 2F7/2! 2F5/2-3berganges des Ytterbiums bei ca. 980 nm eine kooperative Sensibilisierung der Chrom(III)-zentrierten 2E/2T1-Phosphoreszenz bei ca. 775 nm. Der Aufkonvertierungsprozess ist unempfindlich gegenüber Luftsauerstoff und kann in Gegenwart von Wassermolekülen im Kristallgitter beobachtet werden.
BACKGROUND CONTEXT:
Bioresorbable calcium phosphate cement (CPC) may be suitable for vertebroplasty/kyphoplasty of osteoporotic vertebral fractures. However, additional targeted de-
livery of osteoinductive bone morphogenetic Proteins (BMPs) in the CPC may be required to counteract the augmented local bone catabolism and support complete bone regeneration.
PURPOSE:
This study aimed at testing an injectable, poly (l-lactide-co-glycolide) acid (PLGA) fiber-reinforced, brushite-forming cement (CPC) containing low-dose bone morphogenetic Protein BMP-2 in a sheep lumbar osteopenia model.
STUDY DESIGN/ SETTING:
This is a prospective experimental animal study.
METHODS:
Bone defects (diameter 5 mm) were generated in aged, osteopenic female sheep and filled with fiber-reinforced CPC alone (L4; CPC+ fibers) or with CPC containing different dosages of BMP-2 (L5; CPC+ fibers + BMP-2; 1, 5, 100, and 500g BMP-2; n=5 or 6 each). The results were
compared with those of untouched controls (L1). Three and 9 months after the operation, structural and functional effects of the CPC (±BMP-2) were analyzed ex vivo by measuring
(1) bone Mineral density (BMD);
(2) bone structure, that is, bone volume/total volume (assessed by micro-computed tomography [micro-CT] and histomorphometry), trabecular thickness, and trabecular number;
(3) bone formation, that is, osteoid volume/bone volume, osteoid surface/bone surface, osteoid thickness, mineralizing surface/bone surface, mineral Apposition rate, and bone formation rate/bone surface;
(4) bone resorption, that is, eroded surface/bone surface; and
(5) compressive strength.
RESULTS:
Compared with untouched controls (L1), CPC+ fibers (L4) and/or CPC+ fibers + BMP-2(L5) significantly improved all parameters of bone formation, bone resorption, and bone structure.
These effects were observed at 3 and 9 months, but were less pronounced for some parameters at 9 months. Compared with CPC without BMP-2, additional significant effects of BMP-2 were demonstrated for bone structure (bone volume/total volume, trabecular thickness, trabecular number) and formation (osteoid surface/bone surface and mineralizing surface/bone surface), as well as for the compressive strength. The BMP-2 effects on bone Formation at 3 and 9 months were dose-dependent, with 5–100g as the optimal dosage.
CONCLUSIONS:
BMP-2 significantly enhanced the bone formation induced by a PLGA fiber-reinforced CPC in sheep lumbar osteopenia. A single local dose as low as ≤100g BMP-2 was sufficient
to augment middle to long-term bone formation. The novel CPC+ BMP-2 may thus represent an alternative to the bioinert, supraphysiologically stiff polymethylmethacrylate cement presently used to treat osteoporotic vertebral fractures by vertebroplasty/kyphoplasty.
BACKGROUND CONTEXT:
Biodegradable calcium phosphate cement (CPC) represents a promising option for the surgical treatment of osteoporotic vertebral fractures. Because of augmented local bone catabolism, however, additional targeted delivery of bone morphogenetic proteins with the CPC may be needed to promote rapid and complete bone regeneration.
PURPOSE:
In the present study, an injectable, poly(l-lactide-co-glycolide) acid (PLGA) fiber-reinforced, brushite-forming cement (CPC) containing the bone morphogenetic Protein GDF5 was tested in a sheep lumbar osteopenia model.
STUDY DESIGN/SETTING:
This is a prospective experimental animal study
METHODS:
Defined bone defects (diameter 5 mm) were placed in aged, osteopenic female sheep.
Defects were treated with fiber-reinforced CPC alone (L4; CPC+ fibers) or with CPC containing different dosages of GDF5 (L5; CPC+ fibers + GDF5; 1, 5, 100, and 500g GDF5; n =
5 or 6 each).
The results were compared with those of untouched controls (L1). Three and 9 months postoperation, structural and functional effects of the CPC (±GDF5) were assessed ex vivo by measuring
(1) bone mineral density (BMD);
(2) bone structure, that is, bone volume/total volume (assessed by micro-computed tomography and histomorphometry), trabecular thickness, and trabecular number;
(3) bone formation, that is, osteoid volume/bone volume, osteoid surface/bone surface, osteoid thickness, mineralized surface/bone surface, mineral apposition rate, and bone formation rate/bone surface;
(4) bone resorption, that is, eroded surface/bone surface; and
(5) compressive strength.
RESULTS:
Compared with untouched controls (L1), both CPC+ fibers (L4) and CPC+ fibers + GDF5 (L5) numerically or significantly improved all parameters of bone formation, bone resorption, and bone structure. These significant effects were observed both at 3 and 9 months, but for some parameters they were less pronounced at 9 months. Compared with CPC without GDF5, additional significant effects of CPC with GDF5 were demonstrated for BMD and parameters of bone formation and structure (bone volume/total volume, trabecular thickness, and trabecular number, as well as mineralized surface/bone surface). The GDF5 effects were dose-dependent (predominantly in the 5–100g range) at 3 and 9 months.
CONCLUSIONS:
GDF5 significantly enhanced the bone formation induced by a PLGA fiber-reinforced CPC in sheep lumbar osteopenia. The results indicated that a local dose as low as ≤100g
GDF5 may be sufficient to augment middle to long-term bone formation. The novel CPC+ GDF5 combination may thus qualify as an alternative to the bioinert, supraphysiologically stiff poly-(methyl methacrylate) cement currently applied for vertebroplasty/kyphoplasty of osteoporotic vertebral fractures.
Injectable, brushite-forming calcium phosphate cements (CPC) show potential for bone replacement, but they exhibit low mechanical strength. This study tested a CPC reinforced with poly(l-lactide-co-glycolide) acid (PLGA) fibers in a minimally invasive, sheep lumbar vertebroplasty model.
The study aimed to test the in vivo biocompatibility and osteogenic potential of a PLGA fiber-reinforced, brushite-forming CPC in a sheep large animal model.