Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (17)
- Beitrag zu einem Sammelband (6)
- Zeitschriftenartikel (5)
- Forschungsbericht (4)
- Monografie (1)
- Buchkapitel (1)
- Vortrag (1)
- Posterpräsentation (1)
Referierte Publikation
- nein (36) (entfernen)
Schlagworte
- Rheology (6)
- Cement (3)
- Selbstentzündung (3)
- Self-ignition (3)
- Additive manufacturing (2)
- AlSi10Mg (2)
- Halbtechnische Versuche (2)
- Kinetic data (2)
- Laser powder bed fusion (2)
- Reproducibility (2)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (5)
- 2.1 Sicherheit von Energieträgern (5)
- 9 Komponentensicherheit (2)
- 9.6 Additive Fertigung metallischer Komponenten (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.4 Prozessanalytik (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 7 Bauwerkssicherheit (1)
- 7.4 Baustofftechnologie (1)
Eingeladener Vortrag
- nein (1)
Chapter 6: Case studies
(2023)
Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests?
(2022)
The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined.
In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows.
Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods.
Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests?
(2022)
The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined.
In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows.
Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods.
When it comes to higher accuracies, new technologies and real applications in additive manufacturing, there is one topic which cannot be avoided: The material response on the chosen processing parameters and its agreement and correspondence with literature data of the wrought material grade counterpart. In industrial Additive Manufacturing (AM) standards in terms of printing parameters, protection gas atmospheres or powder handling instructions are not obligatory. Therefore, the question must be answered whether the AM process is reproducible and reliable over different printing companies. This was the motivation to realize a round robin test between 8 European printing companies and academic partners. The consortium had printed and tested fatigue and tensile testing bars under plant-specific conditions. A commonly used cast aluminum alloy, AlSi10Mg, was chosen as test material for the PBF-LB/M process. Differences of the results between the partners and the scatter itself were discussed in detail.
When it comes to higher accuracies, new technologies and real applications in additive manufacturing, there is one topic which cannot be avoided: The material response on the chosen processing parameters and its agreement and correspondence with literature data of the wrought material grade counterpart. In industrial Additive Manufacturing (AM) standards in terms of printing parameters, protection gas atmospheres or powder handling instructions are not obligatory. Therefore, the question must be answered whether the AM process is reproducible and reliable over different printing companies. This was the motivation to realize a round robin test between 8 European printing companies and academic partners. The consortium had printed and tested fatigue and tensile testing bars under plant-specific conditions. A commonly used cast aluminum alloy, AlSi10Mg, was chosen as test material for the PBF-LB/M process. Differences of the results between the partners and the scatter itself were discussed in detail.
Viscosity modifying agents: Key components of advanced cement-based materials with adapted rheology
(2022)
Viscosity modifying agents (VMAs) are essential ingredients for the production of flowable cement-based materials. This paper presents an overview of commonly used VMAs and attempts to shed some light on the underlying physics at the origin of their mechanisms of action. The main molecular parameters of VMA controlling the rheological properties of the cement pore solution are highlighted. As the mechanisms of action of VMAs in cement-based materials are closely related to their affinity with the surface of cement particles, the adsorption of the main VMA types is discussed. The effect of VMAs on flow properties and stability of cement-based materials is presented for VMAs added without any superplasticizer, and then in systems incorporating both VMAs and superplasticizers. Finally, the effect of VMAs in enhancing concrete properties to secure adequate performance of different construction applications, and perspectives for future developments of novel cement-based materials made with VMAs are showcased.
Die Technologie-Roadmap „Prozess-Sensoren 2027+“ ist eine Weiterentwicklung vorgängiger Technologie-Roadmaps. Im Zentrum dieser Roadmaps stehen Sensoren zur Erfassung von physikalischen und chemischen Messgrößen mittels spezifischer und unspezifischer Messverfahren, die zur Steuerung und dem besseren Verständnis von Prozessen dienen.
Die Roadmap fasst die gemeinsame Technologie- und Marktsicht von Anwendern, Herstellern und Forschungseinrichtungen im Bereich Prozess-Sensorik in der verfahrenstechnischen Industrie zusammen. Sie beschreibt die wesentlichen Trends im Bereich Prozess-Sensorik und künftige Handlungsbedarfe für Hersteller, Anwender sowie für Einrichtungen der Forschung und Lehre.
Für die aktuellen und zukünftigen Anforderungen an Prozess-Sensoren werden 19 Thesen formuliert. Die Thesen basieren auf den Thesen der vorangegangenen Roadmaps, wobei die aus heutiger Sicht erforderlichen Anpassungen, Ergänzungen und teilweise auch Streichungen vorgenommen wurden. Die Thesen sind in 5 Themencluster eingeordnet. Digitalisierung und Nachhaltigkeit sind übergreifende Kernthemen der künftigen Entwicklung.
Vorgestellt wird ein 2018 gestartetes Projekt zur Überprüfung der Extrapolation von im Labormaßstab ermittelten Selbstentzündungstemperaturen auf technisch relevante Volumina. Für die Ermittlung reaktionskinetischer Daten von Feststoffschüttungen stehen eine Reihe von Untersuchungsmethoden zur Verfügung. Dies sind thermische Analysen wie z. B. die differential scanning calorimetry DSC sowie Mikrokalorimetrie zur hochgenauen Messung von Wärmeströmen, bei denen sehr geringe Probenmengen zum Einsatz kommen. In der Regel wird das Selbstentzündungsverhalten jedoch mithilfe von isoperibolen oder adiabaten Warmlagerungsversuchen beurteilt, hier liegen die Probenvolumina üblicherweise im Bereich von ca. 100 cm3 bis zu einigen Litern. Die Extrapolation über mehrere Größenordnungen auf technische Volumina birgt Unsicherheiten, da mit Zunahme des Lagervolumens veränderte Start- und Randbedingungen vorliegen können. Zudem besteht die Möglichkeit, dass bei in technischen Lagern vorherrschenden niedrigen Temperaturen Reaktionen ablaufen, die in Standard-
Laborversuchen nicht erfasst werden, aber einen wesentlichen Einfluss auf das Selbstentzündungsverhalten aufweisen können. Hauptziel des Projektes ist es daher, die im Labormaßstab vorhandenen Prüfeinrichtungen durch einen Versuchsstand zur Untersuchung von Probengrößen von bis zu 1000 dm3 zu erweitern, die Eignung (oder Nichteignung) der etablierten Methoden nachzuweisen und im Labormaßstab nicht erfassbare Einflussgrößen zu ermitteln. Zudem sollen anhand der kleinskaligen Tests Entscheidungskriterien abgeleitet werden, ob eine Extrapolation nach den derzeit üblichen
Methoden zulässig ist.
Zur Bestimmung der reaktionskinetischen Daten von Schüttgütern und iur Vorhersage des Selbstentzündungsverhaltens großer.Lager kommen verschiedene Analysemethoden zum Einsatz. Dabei handelt es sich .um thermische Verfahren wie die Differential-Scanning- Kalorimetrie OS(. die simultane Thermoanalyse STA sowie die Mikrokalorimetrie zur hochpräzisen Messung von Wärmeströmen. Für die oben genannten Methoden werden sehr kleine Probenmengen verwendet. In der Regel wird das Selbstentzündungsverhalten jedoch mit Hilfe von isoperibolen oder adiabatischen Warmlagerungsversuchen ermittelt: die Probenvolumina liegen hier meist im Bereich von ca. 100 cm3 bis zu mehreren Litern.
Die Extrapolation auf technisch relevante Volumina birgt jedoch erhebliche Unsicherheiten. Diese Unsicherheiten zu identifizieren und zu reduzieren ist das Hauptziel eines 2018 gestarteten Forschungsprojekts. Dies soll in erster Linie durch den Aufbau eines Versuchsstandes zur Untersuchung von Probengrößen von bis zu. 1000 dm 3 geschehen.
Sowohl Warmlagerungsversucl1e im Labormaßstab als auch thermoanalytische Verfahren. die mit Hilfe verschiedener Methoden ausgewertet werden. lassen, einzeln betrachtet. häufig nur bedingt zuverlässige Aussagen über das Selbstentzündungsverhalten von großen Schüttgütern zu. Es werden komplette Versuchsreihen mit allen genannten Prüfverfahren vorgestellt und Aussagen zur Anwendbarkeit der Extrapolationsmethoden diskutiert.
Spherical mesoporous bioactive glasses in the silicon dioxide (SiO2)-phosphorus pentoxide (P2O5)–calcium oxide (CaO) system with a high specific surface area of up to 300m2/g and a medium pore radius of 4 nm were synthesized by using a simple one-pot surfactant-assisted sol–gel synthesis method followed by calcination at 500–700°C. The authors were able to control the particle properties by varying synthesis parameters to achieve microscale powders with spherical morphology and a particle size of around 5–10 mm by employing one structure-directing agent. Due to a high Calcium oxide content of 33·6mol% and a phosphorus pentoxide content of 4·0mol%, the powder showed very good bioactivity up to 7 d of immersion in simulated Body fluid. The resulting microspheres are promising materials for a variety of life science applications, as further processing – for example, granulation – is unnecessary. Microspheres can be applied as materials for powder-based additive manufacturing or in stable suspensions for drug release, in bone cements or fillers.