Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Laser processing (3)
- Volatile organic compounds (3)
- Ablation (2)
- Atomic Force Microscopy (2)
- CO2 assisted impregnation (2)
- Defect shape reconstruction (2)
- Emissions testing (2)
- ICP-MS (2)
- Inversion (2)
- Isotope dilution (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (6)
- 9 Komponentensicherheit (6)
- 4 Material und Umwelt (5)
- 1.1 Anorganische Spurenanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- 9.0 Abteilungsleitung und andere (3)
- 9.2 Versuchsanlagen und Prüftechnik (3)
- 9.5 Tribologie und Verschleißschutz (3)
- 1.4 Prozessanalytik (2)
- 4.1 Biologische Materialschädigung und Referenzorganismen (2)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
- 5 Werkstofftechnik (2)
- 5.1 Mikrostruktur Design und Degradation (2)
- 6 Materialchemie (2)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 6.2 Material- und Oberflächentechnologien (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
- 7 Bauwerkssicherheit (1)
- 7.6 Korrosion und Korrosionsschutz (1)
- S Qualitätsinfrastruktur (1)
- S.1 Qualität im Prüfwesen (1)
Paper des Monats
- ja (1)
Aiming for a round-robin test, a new method for the direct determination of fluorine in niobium oxide has been developed. It is based on the use of high-resolution molecular absorption spectra of calcium mono-fluoride (CaF) generated in the graphite tube, combined with the slurry sampling technique. The absorption measurement was performed at the 606.44 nm CaF rotational line. By using graphite tubes with zirconium carbide (ZrC) modified platform, the molecular absorption sensitivity of CaF has been improved by a factor of 20, and no additional chemical modifier was necessary. Generally, non-spectral interferences were observed in the presence of HCl, H2SO4, and H3PO4. For HCl, additional spectral interference occurred due to an overlap of the absorption spectra of CaF and CaCl. However, due to the absence of these mentioned substances in the current material, such interferences do not exist for this application. The characteristic mass found for the CaF 606.44 nm line was 0.1 ng; the limit of detection was 5 mg fluorine per kg solid sample (3σ criterion). The results obtained by the method were within the range of certified values. Comparing to the classical method such as the pyrohydrolysis-photometric method, the developed new method showed clear advantages regarding sensitivity and specificity. The time requirement for one sample analysis was strongly shortened from several hours to only some minutes.
Normally, in analytical GD-MS, the doubly charged metallic ion signals from the sample are several orders of magnitude less than the corresponding singly charged signals. However, we have observed that using a neon plasma, the M++ signals of some elements, which have double ionization energies close to the first ionization energy of neon, are of the same order as the M+ signal. Doubly charged ions may be produced directly in the discharge cell by electron ionization (EI), and also by two electron Penning ionization (TEP), but these processes cannot explain the above effect. In this paper, we suggest that an additional process named as ‘Charge Transfer and Ionization’ (CTI) produces such ions either in their ionic ground state or in an excited state. To confirm that this process is typical of the discharges used in GD-MS and not an artefact of any particular form of cell and ion extraction system, we have carried out comprehensive experimental measurements using three different GD-MS instruments, viz., Nu Astrum, VG9000 and ELEMENT GD and our results provide clear evidence for CTI. This is the first time the process has been identified as an ionization process in analytical GD-MS. CTI must be differentiated from Asymmetric Charge Transfer (ACT), which is a “selective” process and requires a close energy match (e.g. ΔE < 0.5 eV for a strong effect). On the other hand, CTI is “non-selective” in the sense that a close energy match is not required (e.g. a strong effect is observed with ΔE ∼ 2 eV), although the process only occurs for a limited number of elements, depending on the plasma gas used and the total energy required to doubly ionize the metallic atom.
Copolyesters with an alternating sequence of terephthalic acid and aliphatic dicarboxylic acids were prepared with three different methods. First, dicarboxylic acid dichlorides were reacted with bis(2-hydroxyethyl)terephthalate (BHET) in refluxing 1,2-dichlorobenzene. Second, the same monomers were polycondensed at 0-20 °C in the presence of pyridine. Third, dicarboxylic acid dichlorides and silylated BHET were polycondensed in bulk. Only this third method gave satisfactory molecular weights. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry revealed that the copolyesters prepared by the pyridine and silyl methods might have contained considerable fractions of cyclic oligoesters and polyesters despite the absence of transesterification and backbiting processes. The alternating sequences and thermal properties were characterized with 1H NMR spectroscopy and differential scanning calorimetry measurements, respectively. In agreement with the alternating sequence, all copolyesters proved to be crystalline, but the crystallization was extremely slow [slower than that of poly(ethylene terephthalate)]. A second series of alternating copolyesters was prepared by the polycondensation of silylated bis(4-hydroxybut- yl)terephthalate with various aliphatic dicarboxylic acid dichlorides. The resulting copolyesters showed significantly higher rates of crystallization, and the melting temperatures were higher than those of the BHET-based copolyesters. © 2001 John Wiley & Sons, Inc. J Polym Sci Part A: Polym Chem 39: 3371-3382, 2001
The paper presents numerical methods to detect and classify defects and inhomogeneities by means of active thermography. The objective is to determine the wall thickness of structure elements with an inaccessible back wall, for example, of pipes or Containers. As test specimens we used approximately 2 cm thick PVC samples with spatial variations in the back wall geometry. Flash lamps provided the heating. To know the thickness of the wall, we used two inversion methods and compared the results achieved. One is an iterative echo defect shape method and already tested on Steel test specimens with good reconstruction results. The second one is the Levenberg-Marquardt method, applied here to thermographic data for non-destructive testing. Since data capturing using active thermography and the presented numerical methods can easily be automated, the combination of these two procedures is a promising approach providing a broad area of application.
Structuring of thin-film photovoltaic modules requires basic knowledge of the laser – thin-film interaction in order to adapt the accessible laser parameters, like wavelength, power, repetition rate and scribing speed whilst taking into account the specific material properties of the layer. We have studied the nanosecond laserablation behavior of corresponding layers (i) of silicon based thin-film solar cells with a-Si/µc-Si tandem absorber type and (ii) of back contact and absorber layer of CIGSe solar cells. The respective ablation threshold fluences were determined as integrative parameters describing the specific laser – material interaction. For the threshold determination we used two different methods and developed a new analytical approach taking into account scribing through the glass substrate as it is preferred for most structuring processes. This was done by analyzing the thin film ablation results by means of optical microscopy, profilometry, scanning electron microscopy (SEM). Moreover, we determined the incubation coefficient of the regarded material layers which allows us to predict quantitatively the influence of the spot overlap on the scribing threshold.
Pulse thermography is a non-destructive testing method based on infrared imaging of transient thermal patterns. Heating the surface of the structure under test for a short period of time generates a non-stationary temperature distribution and thus a thermal contrast between the defect and the sound material. In modern NDT, a quantitative characterization of hidden imperfections in materials is desired. In particular, defect depth and shape are of interest. The reconstruction of the defect from thermography data is a nonlinear inverse problem, and ill-posed. We propose an algorithm for the identification of subsurface defects based on the travel time of the reflected thermal pulse. Our work extends results by Lugin and Netzelmann, taking lateral thermal flows directly into account while retrieving the defect depth. This requires significantly less computational work. Quantitative information about the defect shape and depth is obtained. Application of our method to both thermography data generated by a finite element simulation and experimental heating of PVC test specimens with different defects yields good reconstruction of the actual defects.
In this article we present inelastic neutron scattering (INS) experiments on different systems of confined glass-formers. The aim of these experiments is to study the influence of spatial restriction on the microscopic dynamics related to the glass transition. Such results could be helpful for the detection of a currently speculated cooperativity length of the glass transition. The glass-forming component is either a molecular liquid or a polymer. The confining matrices are `hard' (silica glass, silicon) or `soft' (microemulsion droplets). For some experiments the confining structure could be spatially oriented. Except for the soft confinement the naïvely expected acceleration effect could only be found at low temperatures where INS experiments are difficult because of the long relaxation times. A clear effect of confinement could be observed for the glass-typical low energy vibrations (boson peak). This effect seems to be completely different for soft and hard confinement. Surprisingly, the experiments on oriented nanopores did not show any signs of an anisotropy of the dynamics.
Medium and High Entropy Alloys (MEA/HEA) are recently developed material classes, providing manifold applications, e.g., due to extraordinary structural properties. In that connection, the machinability as important issue for the processing of these materials was not in the scientific focus. This study focusses on experimental analysis of milling process conditions including ultrasonic assisted milling (USAM) and their effects on the resulting surface integrity of equiatomic CoCrFeNi-MEA specimens. For that reason, milling parameters (cutting speed, feed per cutting edge) were systematically varied for both conventional milling and USAM. The surface integrity was analyzed in terms of topography, defects, and residual stresses. Especially USAM leads to a decrease of occurring cutting forces and, hence, to an improvement of the surface integrity. Beneficial effects were observed in terms of lower tensile residual stresses at high cutting speed and feed per cutting edge.
Millions of measurements are performed each year by liquid based analytical atomic spectrometry to support healthcare, diagnostic tests, environmental monitoring, material assay, product development and safety. Despite the effort to develop absolute methods, most methods still depend on calibration solutions, which are gravimetric mixtures of high purity solvents and high purity (source material) metals or compounds. As in the real world ideal purity does not exist, the impurity of the solvent and the purity of the source material needs to be known. The impurity of a solvent with respect to one analyte can be measured rather easily and with low limits of determination. In contrast the measurement of the purity of the source material, i.e., the mass fraction of the main constituent in a high purity metal, is more difficult to determine. It becomes even more difficult when the source material is not a pure metal but a compound since problems regarding stoichiometry arise additionally. Although the major producers of calibration solutions make a special effort to determine the purity of the source material, the actual purity statement is often incomplete or not demonstrated. The main reason for this situation is the complexity and high effort necessary to fully characterize such a material. This problem holds to a very wide extent also for the primary standards for element determination at the National Metrology Institutes and Designated Institutes (NMIs and DIs). It is the task of the NMIs and DIs to realise and disseminate primary standards for providing traceability to the International System of Units (SI). The primary elemental standards at the NMIs should provide the link to secondary standards produced by commercial producers and other independently prepared standards for element determination. Without such primary standards, elemental calibration solutions may vary and, depending on the uncertainty required, comparability of measurement in time and space results cannot be achieved.