Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (20)
- Zeitschriftenartikel (5)
- Vortrag (2)
- Posterpräsentation (1)
Schlagworte
- Damage detection (6)
- Damage localization (5)
- Model interpolation (4)
- Value of information (4)
- Fault detection (3)
- Load vector (3)
- Statistical evaluation (3)
- Temperature rejection (3)
- Cable failure (2)
- Cable-stayed bridge (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (2)
Structural health monitoring is a promising technology to automatically detect structural changes based on permanently installed sensors. Vibration-based methods that evaluate the global system response to ambient excitation are suited to diagnose changes in boundary conditions, i.e., changes in member prestress or imposed displacements. In this paper, these changes are evaluated based on sensitivity-based statistical tests, which are capable of detecting and localizing parametric structural changes. The main contribution is the analytical calculation of sensitivity vectors for changes in boundary conditions (i.e., changes in prestress or support conditions) based on stress stiffening, and the combination with a numerically efficient algorithm, i.e., Nelson’s method. One of the main advantages of the employed damage diagnosis algorithm is that, although it uses physical models for damage detection, it considers the uncertainty in the data-driven features, which enables a reliabilitybased approach to determine the probability of detection. Moreover, the algorithm can be trained and the probability of detecting future damages can be predicted based on data and a model from the undamaged structure,
in an unsupervised learning mode, making it particularly relevant for unique structures, where no data from the damaged state is available. For proof of concept, a numerical case study is presented. The study assesses the loss of prestress in a two-span reinforced concrete beam and showcases suitable validation approaches for the sensitivity calculation.
The Stochastic Dynamic Damage Locating Vector (SDDLV) approach is a vibration-based damage localization method based on both a finite element model of a structure and modal parameters estimated
from output-only measurements in the damage and reference states. A statistical version of the Approach takes into account the inherent uncertainty due to noisy measurement data. In this paper, the effect of temperature fluctuations on the performance of the method is analyzed in a model-based approach using a finite element model with temperature dependent parameters. Robust damage localization is carried out by rejecting the temperature influence on the identified modal parameters in the damaged state. The algorithm is illustrated on a simulated structure.
The subject of damage localization is an important issue for Structural Health Monitoring (SHM) particularly in mechanical or civil structures under ambient excitation. In this paper, the statistical subspacebased damage localization method has been applied on a benchmark application, namely a 1/200 scale model of the Saint-Nazaire Bridge, which is a cable-stayed bridge located on the Loire River near the river’s mouth. The employed damage localization method combines data-driven features with physical parameter information from a finite element model in statistical tests, avoiding typical ill-conditioning problems of FE model updating. Damage is introduced in the mockup for cable failures on some of the 72 cables. The purpose of the experiment is to assess the capability of damage assessment methods to find a cable failure.
Temperature variation can be a nuisance that perturbs vibration based structural health monitoring (SHM) approaches for civil engineering structures. In this paper, temperature affected vibration data is evaluated within a stochastic damage detection framework, which relies on a null space based residual. Besides two existing temperature rejection approaches – building a reference state from an averaging method or a piecewise method – a new approach is proposed, using model interpolation. In this approach, a general reference model is obtained from data in the reference state at several known reference temperatures. Then, for a particular tested temperature, a local reference model is derived from the general reference model. Thus, a well fitting reference null space for the formulation of a residual is available when new data is tested for damage detection at an arbitrary temperature. Particular attention is paid to the computation of the residual covariance, taking into account the uncertainty related to the null space matrix estimate. This improves the test performance, contrary to prior methods, for local and global damages, resulting in a higher probability of detection (PoD) for the new interpolation approach compared to previous approaches.
The Stochastic Dynamic Damage Locating Vector (SDDLV) approach is a vibration-based damage localization method based on both a finite element model of a structure and modal parameters estimated from output-only measurements in the damage and reference states. A statistical version of the Approach takes into account the inherent uncertainty due to noisy measurement data. In this paper, the effect of temperature fluctuations on the performance of the method is analyzed in a model-based approach using a finite element model with temperature dependent parameters. Robust damage localization is carried out by rejecting the temperature influence on the identified modal parameters in the damaged state. The algorithm is illustrated on a simulated structure.
The subject of damage localization is an important issue for Structural Health Monitoring (SHM) particularly in mechanical or civil structures under ambient excitation. In this paper, the statistical subspacebased damage localization method has been applied on a benchmark application, namely a 1/200 scale model of the Saint-Nazaire Bridge, which is a cable-stayed bridge located on the Loire River near the river’s mouth. The employed damage localization method combines data-driven features with physical parameter information from a finite element model in statistical tests, avoiding typical ill-conditioning problems of FE model updating. Damage is introduced in the mockup for cable failures on some of the 72 cables. The purpose of the experiment is to assess the capability of damage assessment methods to find a cable failure.
A method to determine the influencing parameters of a structural and damage detection system is proposed based on the value of Information analysis. The value of information analysis utilizes the Bayesian pre-posterior decision theory to quantify the value of damage detection system for the structural integrity management during service life. First, the influencing parameters of the structural system, such as deterioration type and rate are introduced for the performance of the prior probabilistic system model. Then the influencing parameters on the damage detection system performance, including number of sensors, sensor locations, measurement noise, and the Type-I error are investigated. The preposterior probabilistic model is computed utilizing the Bayes’ theorem to update the prior system model with the damage indication information. Finally, the value of damage detection system is quantified as the difference between the maximum utility obtained in pre-posterior and prior analysis based on the decision tree analysis, comprising structural probabilistic models, consequences, as well as benefit and costs analysis associated with and without monitoring. With the developed approach, a case study on a statically determinate Pratt truss bridge girder is carried out to validate the method. The analysis shows that the deterioration rate is the most sensitive parameter on the effect of relative value of information over the whole service life. Furthermore, it shows that more sensors do not necessarily lead to a higher relative value of information; only specific sensor locations near the highest utilized components lead to a high relative value of information; measurement noise and the Type-I error should be controlled and be as small as possible. An optimal sensor employment with highest relative value of information is found. Moreover, it is found that the proposed method can be a powerful tool to develop optimal service life maintenance strategies—before implementation—for similar bridges and to optimize the damage detection system settings and sensor configuration for minimum expected Costs and risks.
Operational modal analysis and vibration based damage detection of engineering
structures have become important issues for Structural Health Monitoring (SHM) and
maintenance operations, e.g. on transport infrastructure. Methods from control
engineering have been adopted and converted for the application on civil structures.
Approaches like subspace-based system identification combine excellent theoretical
properties under the unknown excitation properties of a structure with practical
usefulness.
In this paper, the implementation of covariance-driven stochastic subspace
identification (SSI) on the smart wireless sensor platform PEGASE is described.
Special care is taken about the fast implementation of this technique since the
computations are embedded on the platform and perform in real-time. The most
efficient and current version of subspace algorithms has been implemented. Efficiency
and memory consumption are primary criteria in this implementation.
First validated results will be given for each step of the algorithms: crosscorrelation
on natural inputs signal from sensors; Hankel matrix output; SSI
implementation using the LAPACK library to get a SVD, pseudo-inverse, eigenvalues
etc. Results validation has been correlated between PEGASE implementation and the
previous processing in static situation: the same data was collected by wired sensors
and data-loggers, then, later, processed on a PC using traditional Matlab software.
In parallel, from an engineering point of view, a description of the PEGASE
wireless platform will be given: generic usage, wide capacities, embedded Digital
Signal Processing (DSP) processor and Library over a small embedded Linux
Operating System, a very accurate synchronization principle based on a GPS/PPS
principle, etc. Perspectives about a complete technical in-situ installation will also be
given.
Environmental based perturbations influence significantly the ability to identify structural dam-age in Structural Health Monitoring. Strategies are needed to classify such effects and consider them appropri-ately in SHM. It has to be considered if seasonal effects just mask the structural response or if temperature itself correlates to a weakening of the structure. Various methods have been developed and analyzed to separate environmental based effects from damage induced changes in the measures. Generally, two main approaches have emerged from research activity in this fields: (a) statistics-based tools analyzing patterns in the data or in computed parameters and (b) methods, utilizing the structural model of the bridge considering environmental as well as damage-based changes of stiffness values. With the background of increasing affordability of sensing and computing technology, effort should be made to increase sensitivity, reliability and robustness of proce-dures, separating environmental from damage caused changes in SHM measures. The contribution describes an attempt to evaluate both general strategies, their advantages and drawbacks. In addition, two vibration moni-toring procedures are introduced, allowing for temperature-based perturbations of the monitoring data.
Damage detection and localization in civil or mechanical structures is a subject of active development and research. A few vibration‐based methods have been developed so far, requiring, for example, modal parameter estimates in the reference and damaged states of the investigated structure, and for localization in addition a finite element model. For structures in operation, temperature has been shown to be a major nuisance to the efficiency of such methods because the modal parameters are varying not only with damage but also due to temperature variations. For detection, a few rejection approaches have been developed. Besides the increased complexity, environmental variation is hardly taken into account in localization approaches. In this paper, we propose a sensitivity‐based correction of the identified modal parameters in the damaged state with respect to the temperature field in the reference state, on the basis of a sensitivity analysis with respect to temperature dependent Parameters of the finite element model in the reference state. The approach is then applied to the stochastic dynamic damage locating vector method, where its improved performance under nonuniform temperature variations is shown in a numerical application on a beam.