Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (38)
- Beitrag zu einem Tagungsband (11)
- Forschungsbericht (4)
- Beitrag zu einem Sammelband (2)
- Vortrag (1)
- Sonstiges (1)
Schlagworte
- Ellipsometry (5)
- Thin films (4)
- Gas sensing (3)
- Mass spectrometry (3)
- Zentrifugentechnologie (3)
- Antibody (2)
- Carbon steel (2)
- Cement (2)
- Chlorinduzierte Korrosion (2)
- Cyclic voltammetry (2)
- DOTA (2)
- Doped tin oxide (2)
- Electrochromism (2)
- Ellipsometrie (2)
- Haftfestigkeit (2)
- Härteprüfung (2)
- Mehr-Proben-Prüfung (2)
- Metal labeling (2)
- Metallo-supramolecular polyelectrolytes (2)
- Mueller-Matrix imaging ellipsometry (2)
- Optical properties (2)
- Passivität (2)
- Spectroskopic Imaging (2)
- Stahlbeton (2)
- TMF (2)
- Tandem MS (2)
- Thermo-mechanical fatigue (2)
- Abbildende Ellipsometrie (IE) (1)
- Abwassersysteme (1)
- Adhesion (1)
- Air-coupled (1)
- Air-coupled ultrasonics (1)
- Airborne (1)
- Alkalisch aktivierte Bindemittel (1)
- Amorphization (1)
- Amorphous state (1)
- Anti-counterfeiting (1)
- Aquifer fluid (1)
- Beanspruchung auf Zug und Druck (1)
- Brinell- und Vickers Härte (1)
- CCS (1)
- CID (1)
- Carbon (1)
- Carbon capture (1)
- Carbon capture storage (1)
- Carbon dioxide (1)
- Carbon-based Films (1)
- Casing (1)
- Centrifuge technology (1)
- Certified reference material (1)
- Certified reference materials (1)
- Cisplatin (1)
- Coagulation (1)
- Coated/Layered Reference Materials (1)
- Coatings (1)
- Collision induced dissociation (CID) (1)
- Collision-induced dissociation (1)
- Colouration efficiency (1)
- Compressive strength (1)
- Corrosion (1)
- Corrosion and storage (CCUS) technology (1)
- Crevice corrosion (1)
- Crystallization (1)
- DNA (1)
- Dauerhaftigkeit (1)
- Degradation (1)
- Depassivierung (1)
- Depth profiling (1)
- Design for durability (1)
- Dip coating (1)
- Double strands (1)
- Druckfestigkeit (1)
- Einflüsse (1)
- Electrochromic device (1)
- Electromechanical properties (1)
- Ellipsometric encoding (1)
- Fabry-Perot Schichten (1)
- Fabry-Perot layer stacks (1)
- Fabry-Perot layers (1)
- Fatigue damage (1)
- Fatigue life time (1)
- Fehlerquellen (1)
- Femtosecond laser (1)
- Ferroelectret (1)
- Ferroelectrets (1)
- Fragmentation (1)
- Fragmentation activation (1)
- GDS (1)
- Gadolinium-based contrast agents (GBCAs) (1)
- Glow discharge spectrometry (1)
- Glycans (1)
- HCD (1)
- Hardness (1)
- Hydrogen (1)
- ICP-MS (1)
- ISO (1)
- Imaging Ellipsometrie (1)
- Imaging Null Ellipsometrie (INE) (1)
- Imaging ellipsometry (IE) (1)
- Impurities (1)
- Inhomogeneous and patterned thin films (1)
- Interlaboratory Comparison (1)
- Ion mobility (1)
- Ion mobility spectrometry (1)
- Iron doped tin oxide (1)
- Karbonatisierung (1)
- Klebfestigkeit (1)
- Kohlenstoffschichten (1)
- Labeling (1)
- Lanthanide (1)
- Lanthanide DOTA (1)
- Lanthaniden (1)
- Laser ablation inductively coupled plasma–mass spectrometry imaging (LA-ICP-MSI) (1)
- Life time prediction (1)
- Locked nucleic acids (1)
- Macrocell corrosion model (1)
- Magnetron (1)
- Magnetron sputtering (1)
- Matrix-assisted laser desorption ionization–mass spectrometry imaging (MALDI-MSI) (1)
- Metal oxides (1)
- Metall-Markierung (1)
- Metrology (1)
- Mikroskopie (1)
- Multilayer (1)
- Multiple-sample testing (1)
- Multiplexing (1)
- Nanometerbereich (1)
- Native MS (1)
- Ni-base superalloy (1)
- Nitrides (1)
- Non-contact transducers (1)
- Oberflächenverunreinigungen (1)
- Oligonucleotide (1)
- Oligonucleotide fragmentation (1)
- Optical Property (1)
- Optical materials (1)
- Optical microscopy (OM) (1)
- PA-CVD (1)
- PTM (1)
- Patterned films (1)
- Photoresist (1)
- Pitting (1)
- Plasma collision processes (1)
- Plasma deposition (1)
- Plasmachemie (1)
- Plasmonic absorption (1)
- Polarization spectroscopy (1)
- Potentialmessung (1)
- Product authentification (1)
- Produkt- und Markenschutz (1)
- Protein quantification (1)
- Protein-Quantifizierung (1)
- Quantitative proteomics (1)
- Reagenzien (1)
- Referenced Spectral Ellipsometry (RSE) (1)
- Referenced spectroscopic ellipsometry (RSE) (1)
- Refractive index (1)
- Reinforcement corrosion (1)
- Reparatursysteme (1)
- Resonance (1)
- Round Robin (1)
- SPR effect (1)
- Schichtdicke (1)
- Schleimpflug-Optik (1)
- Scratch test (1)
- Sheet resistivity (1)
- SiO2 (1)
- Silicon (1)
- SnO2 (1)
- Spectroscopic ellipsometry (1)
- Spectroscopic imaging and mapping ellipsometry (1)
- Spectroscopic imaging ellipsometry (1)
- Stable isotope labeling (1)
- Standardisation (1)
- Structural anomalies (1)
- Structural inhomogenities (1)
- Surface plasmon (1)
- Surface plasmon resonance (1)
- THz-Wellen (1)
- Tandem-MS (1)
- Tensile strength (1)
- Terahertzsysteme (1)
- Test methods (1)
- Thermo-Mechanical strain-controlled fatigue testing (1)
- Thermoacoustic (1)
- Transparent conductive oxides (1)
- Transparent conductive oxides (TCO) (1)
- Ultrasonic transducer (1)
- Utilization (1)
- Vacuum ultraviolet (VUV) light (1)
- Vanadium oxide (1)
- Verbund (1)
- Verbundfestigkeit (1)
- Visualisierung bei geringem Kontrast (1)
- XAFS (1)
- XPS characterzation (1)
- Zugfestigkeit (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (6)
- 1.9 Chemische und optische Sensorik (4)
- 6 Materialchemie (4)
- 6.7 Materialsynthese und Design (4)
- 7 Bauwerkssicherheit (3)
- 5 Werkstofftechnik (2)
- 5.1 Mikrostruktur Design und Degradation (2)
- 7.6 Korrosion und Korrosionsschutz (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.3 Instrumentelle Analytik (1)
Eingeladener Vortrag
- nein (1)
Tandem mass spectrometry represents an important analytical tool to unravel molecular structures and to study the gas-phase behavior of organic molecules. Besides commonly used methods like collision-induced dissociation and electron capture or transfer dissociation, new ultraviolet light–based techniques have the potential to synergistically add to the activation methods. Here, we present a new simple, yet robust, experimental design for polychromatic activation of trapped ions using the 115–160 nm output of a commercially available deuterium lamp. The resulting continuous dissociative excitation with photons of a wide energy range from 7.7 to 10.8 eV is studied for a comprehensive set of analyte classes in both positive and negative ion modes. While being simple, affordable, compact, and of low maintenance, the new setup initiates fragmentation of most precursor ions via their known dissociation pathways. Additionally, some new fragmentation patterns were discovered. Especially, electron loss and electron capture reactions with subsequent fragmentations were observed. For oligonucleotides, peptides, carbohydrates, and organic dyes, in comparison to collision-induced dissociation, a significantly wider fragment distribution was obtained, resulting in an information increase. Since the individual photons carry enough energy to post-ionize the nascent fragments, a permanent vacuum ultraviolet light exposure inside the ion trap potentially goes along with a general increase in detection capability.
Visualization of surface modifications may be very challenging for coating/substrate systems of either almost identical optical constants, e.g. transparent films on substrates of the same material, or minor film thickness, substance quantity and affected area, e.g. ultra-thin or island films. Methods for visualization are optical microscopy (OM), imaging ellipsometry (IE), and referenced spectroscopic ellipsometry (RSE). Imaging ellipsometry operates at oblique incidence near Brewster angle of the bare, clean or unmodified substrate. In this configuration, reflected intensities are rather weak. However, the contrast to add-on and sub-off features may be superior. Referenced spectroscopic ellipsometry operates in a two-sample configuration but with much higher intensities. In many cases, both ellipsometric techniques reveal and visualize thin films, printed-pattern, laser-induced changes, and impurities better than optical microscopy. In particular for stratified homogeneous modifications, ellipsometric techniques give access to modelling and hence thickness determination. Modifications under investigation are polymer foil residue on silicon, laser-induced changes of ta-C:H coatings on 100Cr6 steel, imperfections of ta-C:H on thermal silicon oxide, degradation of glass, thin film tin oxide pattern on silicon, printed and dried pattern of liquids such as deionized water, cleaning agents, and dissolved silicone. © 2016 Elsevier B.V. All rights reserved.
Die Oberflächentechnik ist eine Schlüsseltechnologie in nahezu zu allen industriellen Branchen. Mit Ausnahme der mechanischen Stabilität, die das Substrat bereitstellt, werden verschiedenartigste Funktionen materialsparend, zum Teil hochintegriert mit maßgeschneiderten Schichtdesigns unter Ausnutzung von Nano- und Quanteneffekten auf Oberflächen appliziert. Ein Großteil der Fertigungskosten in der Mikro- und Nanotechnik wird durch Reinräume und die Umsetzung ausgeklügelter Reinigungsstrategien zur Vermeidung von Restverschmutzungen und partikulären Belegungen
verursacht, da diese unweigerlich zum Bauteilversagen führen. Die Validierung des Reinigungszustandes ist somit von zentraler Bedeutung für die Schichtqualität und Produktfunktionalität. Dies gilt in Abhängigkeit von der Applikation und den vertikalen Schicht- bzw. lateralen Strukturdimensionen sowohl für Fertigungsprozesse im Reinraum als auch für solche in robuster Umgebung. In der Praxis kommt es häufig vor, dass man mikroskopisch scheinbar saubere Substrate erst durch die Beschichtung „enttarnt" und dann Defekte oft mit bloßem Auge sichtbar werden. Noch problematischer ist der Einbau von Verunreinigungen während der Schichtabscheidung, die zunächst nicht sichtbar sind, dann aber zum Bauteilversagen führen.
For the vast majority of ellipsometric measurements, the application of planar substrates is mandatory and requires a proper sample alignment prior to the measurement. Here, the authors present a generalized approach of how to extract the isotropic ellipsometric sample parameters from an imaging Mueller-matrix measurement even if the sample is significantly misaligned. They validate the method by layer-thickness calculations based on imaging Mueller-matrix measurements of flat crystalline silicon samples that were misaligned on purpose. Furthermore, they also exploit this method’s capabilities to perform spatially resolved layer-thickness measurements of a single-layer indium-tin-oxide coating on a fused-silica microlens without the need of realignment or repositioning of the sample during the measurement.
Background: Gas sensors are very important in several fields like gas monitoring, safety and environmental applications. In this approach, a new gas sensing concept is investigated which combines the powerful adsorption probability of metal oxide conductive sensors (MOS) with an optical ellipsometric readout. This concept Shows promising results to solve the problems of cross sensitivity of the MOS concept.
Results: Undoped tin oxide (SnOx) and iron doped tin oxide (Fe:SnOx) thin add-on films were prepared by magnetron sputtering on the top of the actual surface plasmon resonance (SPR) sensing gold layer. The films were tested for their sensitivity to several gas species in the surface plasmon resonance enhanced (SPREE) gas measurement. It was found that the undoped tin oxide (SnOx) shows higher sensitivities to propane (C3H8) then to carbon monoxide (CO). By using Fe:SnOx, this relation is inverted. This behavior was explained by a change of the amount of binding sites for CO in the layer due to this iron doping. For hydrogen (H2) no such relation was found but the sensing ability was identical for both layer materials. This observation was related to a different sensing mechanism for H2 which is driven by the Diffusion into the layer instead of adsorption on the surface.
Conclusion: The gas sensing selectivity can be enhanced by tuning the properties of the thin film overcoating. A relation of the binding sites in the doped and undoped SnOx films and the gas sensing abilities for CO and C3H8 was found. This could open the path for optimized gas sensing devices with different coated SPREE sensors.
Die nicht ionisierende elektromagnetische Strahlung im Bereich von Terahertz-Frequenzen ermöglicht berührungslose und zerstörungsfreie Mess- und Prüftechnik in zahlreichen Bereichen. Nach ersten Anwendungen in der Astronomie und der Atmosphärenforschung wurden in letzter Zeit Anwendungsfelder in der Sicherheitstechnik, der Medizintechnik, der Nachrichtentechnik und der zerstörungsfreien Prozess- und Qualitätskontrolle erschlossen. Dielektrische Materialien wie Kunststoffe und Keramiken können von Terahertz-Wellen durchdrungen werden. Das ermöglicht Untersuchungen des Objektinneren ohne spezielle Schutzmaßnahmen, wie sie z.B. beim Röntgen notwendig sind. Die Richtlinie erleichtert die Verständigung zwischen Nutzern, Herstellern und dem Vertrieb von Terahertz-Systemen. In der Richtlinie werden bekannte Einsatzgebiete sowie die eingesetzten Verfahren und Funktionsprinzipien aufgeführt, um den Leser bei der Auswahlentscheidung zu unterstützen. Nach einer kurzen Einführung in die physikalischen Grundlagen und Hinweisen zur elektromagnetischen Verträglichkeit, zum Strahlenschutz und zur regulierten Frequenzvergabe werden die verschiedenen Geräteklassen von Terahertz-Systemen ausführlich vorgestellt. Die Richtlinie gibt Hinweise zur messtechnischen Charakterisierung von Terahertz-Wellen. Einsatzgebiete von Terahertz-Systemen, wie die zerstörungsfreie Prüfung, die Dicken- und Abstandsmessung, die Tomografie und die chemische Analytik, werden mit ihren spezifischen Eigenschaften im Detail beschrieben. Umfangreiche Literaturverweise vereinfachen eine vertiefte Beschäftigung mit den Themen der Richtlinie. Eine tabellarische Übersicht mit einer Zusammenfassung, welche Terahertz-Systeme für welche Anwendungsfelder eingesetzt werden können, vervollständigt die Richtlinie.
Metal ion induced self-assembly of iron(II)-acetate with the rigid ditopic ligand 1,4-bis(2,2':6',2''-terpyridin-4'-yl)benzene results in a metallo-supramolecular coordination polyelectrolyte (Fe-MEPE). Fe-MEPE shows a strong absorption band in the visible region around 590 nm, attributed to a metal-to-ligand-charge-transfer (MLCT) transition, which is responsible for the deep blue colour. Large area thin films of high optical quality can be readily fabricated by a dip coating process on transparent conducting electrodes. The Fe-MEPE films have a temperature stability up to 80 °C, measured by optical spectroscopy and XAFS (x-ray absorption fine structure). The cathodically coloured Fe-MEPE shows outstanding electrochromic properties and can be reversibly switched from Fe(II) (blue) to Fe(III) (colourless) by applying a potential of 4.1 V vs. Li/Li+. A very high optical contrast ΔT of 71% at a wavelength of 590 nm and a colouration efficiency of around 525 cm² C-1 can be realized. The devices show a long-term stability about 10,000 cycles. Thus, Fe-MEPE is a very promising electrochromic material for future applications of smart windows.