Filtern
Erscheinungsjahr
- 2023 (17)
- 2022 (16)
- 2021 (14)
- 2020 (12)
- 2019 (17)
- 2018 (6)
- 2017 (15)
- 2016 (11)
- 2015 (17)
- 2014 (7)
- 2013 (7)
- 2012 (15)
- 2011 (10)
- 2010 (8)
- 2009 (9)
- 2008 (9)
- 2007 (8)
- 2006 (18)
- 2005 (14)
- 2004 (12)
- 2003 (6)
- 2002 (7)
- 2001 (7)
- 2000 (5)
- 1998 (2)
- 1997 (6)
- 1996 (1)
- 1995 (2)
- 1994 (6)
- 1991 (2)
- 1990 (2)
- 1989 (4)
- 1988 (4)
- 1987 (5)
- 1986 (9)
- 1985 (2)
- 1984 (6)
- 1983 (4)
- 1982 (1)
- 1981 (2)
- 1980 (1)
Dokumenttyp
- Vortrag (134)
- Zeitschriftenartikel (66)
- Beitrag zu einem Tagungsband (66)
- Beitrag zu einem Sammelband (32)
- Forschungsbericht (14)
- Posterpräsentation (13)
- Buchkapitel (1)
Sprache
- Englisch (170)
- Deutsch (149)
- Spanisch (5)
- Französisch (2)
Schlagworte
- Ground vibration (39)
- Layered soil (13)
- Slab track (11)
- Mitigation (10)
- Railway track (10)
- Bahnerschütterungen (9)
- Erschütterungen (9)
- Finite-element boundary-element method (9)
- Track-soil interaction (9)
- Train passage (9)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (82)
- 7.2 Ingenieurbau (82)
Eingeladener Vortrag
- nein (134)
The train passages over intact or damaged slab tracks on different soils have been calculated by two methods. The finite element method (FEM) uses a Winkler soil under the track model by adding a thin “soil layer”. The combined finite element boundary element method has a continuous soil model which is included by the boundary element method. The basic results are the distributions of the track (rail, track plate, and base layer) displacements along the track for a single axle laod. These solutions are superposed to a complete train load and transformed to time histories. The influence of track and soil parameters has been analysed. The main interest is the influence of the track damage. A gap between track plate and base layer of different lengths has been studied for changes in amplitudes and widths of deflection. A best fit to measured track displacements has been found so that the track damage can be identified and quantified. The FEM model with Winkler soil cannot be fitted to the amplitude and width with the same soil parameters. Therefore, the FEBEM model is preferable for these railway track problems.
Measurements of downburst wind loading acting on an overhead transmission line in northern Germany
(2017)
Along an overhead transmission line in Northern Germany, a unique instrumentation of anemometers and force measurements is installed. Details of this test line with wind measurements along a horizontal axis are given. A recent event of a presumable downburst wind event is analyzed by means of available data and precedent works on thunderstorm analysis. The measured response of the conductors at the suspension tower is investigated and compared with time domain simulation of a finite element model.
A study on building vibrations has been performed by finite element calculations. Family houses, multi-storey residential buildings, office buildings and office towers have been modelled in detail. The frequency-dependent response due to a free-field excitation has been evaluated for walls, columns and floors. The ratio of building amplitudes to free-field amplitudes starts with uB/u0 = 1 at zero frequency and is usually lower than 1 at 50 Hz, the end of the frequency range considered here. In between, amplifications occur due to several reasons. There are „soil resonances“ where the whole building is vibrating on the compliant soil, “column resonances” where the upper storeys are vibrating on the compliant columns, and the “floor resonances” where the floors are vibrating excited by their supports. Results are presented for all building types, but a special focus is set on office buildings. A parameter study shows the influence of the stiffness of the soil, the number of storeys, and the width of the building. It has been found that the “soil resonance” is strongly modified by the low-frequency floor resonances for the normal office building. The main resonance of a twenty-storey office tower is determined equally by the “soil mode” and the “column mode”. It is an important observation for these office buildings that the resonances can differ for different parts of the building such as the centre, the edge, the corner, and the core of the building. This leads to non-uniform vibration modes across the building, which look like another type of “floor resonance” and which have been observed in several real building projects. Experimental results will be shown which can confirm the calculated phenomena.
There is a strong need for cost-effective mitigation measures for
turnouts. SBB has initiated a series of examinations using different methodologies to gain a deeper understanding of the excitation mechanisms at low frequencies, in addition to that obtained in the RIVAS project. To date it is not yet clear what constitutes a complete measurement data set that would enable understanding most of the vibration excitation mechanisms in turnouts. Increasing vibration at turnouts in comparison to normal track is observed for all measured frequencies.
The different methodologies are presented in the paper. Under-sleeper pads (USP) are a cost-effective method to reduce vibration at frequencies above 63 Hz (1/3 octave), but there is probably no improvement for frequencies below 63 Hz. A first test of new frog geometry did not show relevant improvements in Vibration emission in comparison to a reference frog geometry. Axle box acceleration measurements are an interesting method to identify defects in a turnout. A specialized measurement system of rail roughness could identify certain geometry Problem areas for some frogs. Noise increases also are observed at turnouts for frequencies ranging between 80 to 1000 Hz. The use of railway source models to calculate
contact forces for ballasted track and turnouts seems promising, in particular for understanding the influence of ground.