Filtern
Dokumenttyp
- Vortrag (37) (entfernen)
Referierte Publikation
- nein (37) (entfernen)
Schlagworte
- Ground vibration (8)
- Bahnerschütterungen (4)
- Building vibration (4)
- Erschütterungsminderung (3)
- Container loading (2)
- Dispersionsmessung (2)
- Drop test (2)
- Elastische Elemente (2)
- Elastische Gleiselemente (2)
- Emission (2)
- Erschütterungen (2)
- Erschütterungsprognose (2)
- Foundation load (2)
- Hammer impact (2)
- Layered soil (2)
- Railways (2)
- Slab track (2)
- Train passage (2)
- Train-induced ground vibration (2)
- Tunnel (2)
- Vehicle-track-soil interaction (2)
- Vibration measurements (2)
- Wellengeschwindigkeit (2)
- 2-span bridge (1)
- Achsimpulse (1)
- Amplituden-Abstands-Gesetze (1)
- Apartment building (1)
- Attenuation (1)
- Axle impulses (1)
- Axle pulses (1)
- Axle-sequence spectrum (1)
- Bahngleis (1)
- Ballast track (1)
- Base isolation (1)
- Bauwerk-Boden-Wechselwirkung (1)
- Bodenschlitz (1)
- Bodenübertragungsfunktion (1)
- Cars (1)
- Damage detection (1)
- Deckeneigenfrequenzen (1)
- Deckenschwingungen (1)
- Displacements (1)
- Dämpfung (1)
- Einfügungsdämmung (1)
- Elastische Gebäudelagerung (1)
- Erschütterungen im Fernfeld (1)
- Erschütterungsausbreitung (1)
- Evaluation (1)
- Excitation forces (1)
- Fahrzeug-Fahrweg-Boden-Wechselwirkung (1)
- Filter effects (1)
- Finite element models (1)
- Flexibility (1)
- Floors (1)
- Footbridge (1)
- Foundations (1)
- Freight train (1)
- Frequency response function (1)
- Gebäudelagerung (1)
- Gebäudemodelle (1)
- Gebäudeschwingungen (1)
- Geometrie (1)
- Gleiströge (1)
- Ground vibration measurements (1)
- Halbraum (1)
- High-rise buildings (1)
- High-speed train (1)
- Immission (1)
- Impedanzmethode (1)
- Inertial interaction (1)
- Irregular ballast (1)
- Irregular soil (1)
- Irregularities (1)
- Kinematic interaction (1)
- Kraft auf den Boden (1)
- Layered soils (1)
- Measurement (1)
- Measurements (1)
- Mitigation (1)
- Modal load spectrum (1)
- Modes and waves (1)
- Movin load test (1)
- Normung (1)
- Office tower (1)
- Passenger train (1)
- Pfahlnachgiebigkeiten (1)
- Pile groups (1)
- Prediction (1)
- Prognose (1)
- Railbridge (1)
- Railway (1)
- Railway bridge (1)
- Railway tracks (1)
- Railway trafiic (1)
- Railway tunnel (1)
- Randelementmethode (1)
- Randomly heterogeneous soil (1)
- Rayleighwellendispersion (1)
- Rechenmodelle (1)
- Rechenverfahren (1)
- Richtige Fahrzeugmasse (1)
- Scattering (1)
- Schienenfahrweg (1)
- Schienenfahrwege (1)
- Simple and fast prediction (1)
- Soil-pile interaction (1)
- Soil-wall floor model (1)
- Spektralanalyse (1)
- Störgrößen (1)
- Surface line (1)
- Surface-tunnel reduction (1)
- Train configuration (1)
- Train excitation (1)
- Train passages (1)
- Train speed (1)
- Tran speed (1)
- Transfer fuction (1)
- Transmission (1)
- Tunnel line (1)
- Tunnelstrecke (1)
- Varying soil stiffness (1)
- Varying track stiffness (1)
- Vibration measurement (1)
- Vollraum (1)
- Wellenausbreitung (1)
- Wellenausbreitung in der Tiefe (1)
- Wellenfeldberechnung (1)
- Zuggeschwindigkeit (1)
- elastische Gebäudelagerungen (1)
- zerstreute Achslastimpulse (1)
- Übertragungsmatrizen (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (37) (entfernen)
Eingeladener Vortrag
- nein (37) (entfernen)
A prediction software has been developed by BAM. The following topics have still be solved. A realistic irregularity spectrum can be derived from axle-box measurements. It agrees wel with the spectrum used for the high-speed 2 project in the United Kingdom. In addition, the scattering of axle pulses should be included. This mid-frequency component can also be found in the HS2 procedure. Finally, the reduction in case of a tunnel line compared to a surface line should be included. Some measurement results of BAM, HS2 and other institutes show a certain mid-frequency reduction. This is due to the load distribution of the tunnel which yields softer axle pulses and the scattered axle impulses are reduced.
Dieser Vortrag präsentiert einige Prinzipien und einige Beispiele zur Minderung von Eisenbahnerschütterungen. Die Prinzipien unterscheiden sich für die Minderungsmaßnahmen im Gleis, im Boden und bei Gebäuden. Kraftübertragungsfunktionen isolierter und nicht isolierter Gleissysteme, reflektierte und durchgelassene Wellenamplituden bei gefüllten Bodenschlitzen und die Übertragung der Freifeldschwingungen ins Gebäude werden analysiert. Bei den einfachen Gleismodellen muss der richtige Anteil der unabgefederte Fahrzeugmasse zum eindimensionalen Gleismodell hinzugefügt werden. Der Minderungseffekt eines gefüllten Bodenschlitzes ist von der Steifigkeit und nicht von der Impedanz des Schichtmaterials bestimmt. Bei einer elastischen Gebäudelagerung muss die Minderungswirkung mit der richtigen Boden- (Fundament-) Steifigkeit berechnet werden, und das abgeminderte Gebäudeverhalten hängt wesentlich von der effektiven Gebäudemasse ab, die mit zunehmender Frequenz deutlich kleiner als die starre Gebäudemasse ist.
Eindimensionale Modelle des Gleises aus einem Schienenstützpunkt, zweidimensionale Modelle enthalten die Kraftverteilung der Schiene. Eindimensionale Modelle machen einen Fehler, weil sie eine zu große Fahrzeugmasse berücksichtigen. Man kann jedoch bei der Berechnung der Minderungswirkung von Gleiselementen eindimensionale Gleismodelle verwenden, um die Kraftübertragung des Gleises bzw. die Minderungswirkung des Gleises zu berechnen. Die Wechselwirkung mit dem Fahrzeug kann einfach mit der dynamischen Stützpunktsteifigkeit berechnet werden. Dabei muss die Stützpunktsteifigkeit mit einer charakteristischen Gleislänge multipliziert werden, die frequenz- und systemabhängig ist.
Die Definition und Beschreibung der Einfügedämmung im Normentwurf DIN 45673-4 ist noch nicht richtig. Es wird die Beschreibung aus DIN 45673-3 herangezogen, die für Messungen gilt. Für die drei Rechenverfahren gibt es jeweils eine passende Beschreibung. Mit diesen Vorlagen ist eine vernünftige Definition der Einfügungsdämmung zu finden. Es bedarf einer Abgrenzung gegenüber anderen (falschen) Möglichkeiten. Des Weiteren ist der Anhang 2 erweitert und der Parametersatz im Anhang 1 auf das Wesentliche reduziert worden.
Prediction of building noise and vibration – 3D finite element and 1D wave propagation models
(2021)
Construction work or traffic excite nearby buildings, and the perceptible or audible vibration can be a nuisance for the inhabitants. The transfer of the vibration from the free field to the building has been calculated by the finite element method for many models in consultancy and research work. The analysis for all storeys of certain building points such as walls, columns and floors unveiled some rules, some typical modes, and some wavetype responses. A simplified building-soil model has been created, which includes well these effects of building-soil resonance, wall/column resonance, floor resonances, and the high-frequency reduction. The model consists of one wall for a wall-type apartment building or a column for each specific part (mid, side or corner) of a column-type office building. The building response in the high-frequency (acoustic) region is calculated as mean values over all storeys and over wider frequency bands, by wave-type asymptotes of an infinitely tall building, and by the soil to wall ratio of impedances. The secondary noise is predicted by Transfer values between the building vibration (center of floors, walls at a room corner) and the sound pressure.
Die Linienlastgesetzmäßigkeit gilt nicht für Zuganregung. Die Punktlastgesetzmäßigkeit wird bei kurzen Zügen in größeren Entfernungen erreicht. Bei langen Zügen reduziert sich die Abnahme um r-0,3 für die theoretische exponentielle Dämpfungsabnahme, um r-0,5 für die vereinfachte potentielle Dämpfungsabnahme. Die gemessenen Abnahmereduktionen liegen in diesem Bereich.
Zur Erschütterungsausbreitung an oberirdischen Bahnlinien gibt es gute Übereinstimmungen zwischen Messungen und der Theorie geschichteter Böden. Bei der Interpretation der Ergebnisse spielt die Rayleigh-Welle eine große Rolle. Je nach Frequenz und Wellenlänge hat die Rayleigh-Welle eine bestimmte Eindringtiefe und erreicht damit mehr oder weniger steife Bodenschichten. Damit bekommt man eine frequenzabhängige Bodensteifigkeit für die Erschütterungsprognose. Für die Wellenausbreitung in der Tiefe statt an der Bodenoberfläche müssen eigene Gesetzmäßigkeiten gefunden werden. Es werden die Punktlastlösungen im Frequenz-Wellenzahlbereich und durch Integration über die Wellenzahlen berechnet. Man erhält die Wellenfelder, die Terzspektren für verschiedene Entfernungen und Frequenzen. Es wird die Tiefenlage und das Bodenmodell (homogen, geschichtet und kontinuierlich zunehmende Steifigkeit) variiert. Die Rayleigh-Welle verliert ihre Bedeutung und stattdessen kann die Vollraumlösung zur Interpretation und Prognose verwendet werden. Es werden die Halbraumlösung mit und ohne Rayleigh-Welle und die Vollraumlösung in der Tiefe diskutiert und verglichen. Neben der Wellenausbreitung (der Transmission) werden auch Effekte der Erschütterungsanregung (der Emission) und der Übertragung in Gebäude (der Immission) mit Hilfe der Finite-Element-Randelement-Methode berechnet. Die Verteilung der dynamischen Achslast durch die Tunnelsohle ergibt eine Minderung gegenüber der Punktlastanregung. Bei der Immission hat man keine Freifeldanregung wie an der Bodenoberfläche. Man muss entweder neben der Wellenamplitude (Verschiebung oder Schwinggeschwindigkeit) in der Tiefe auch die Spannung der ankommenden Welle berücksichtigen, oder man muss die Freifeldamplituden nach Bodenaushub berechnen. Die Rechenergebnisse deuten darauf hin, dass man als Freifeldanregung die zweifache Vollraumlösung ansetzen kann.
Measurements at the foundation, the surrounding soil and nearby buildings have been done during several drop tests of different containers on different foundations. The first measurements have been done on a big foundation where it should be guaranteed that the foundation is rigid and the container is tested properly. It was controlled that the foundation does not absorb more than 2 percent of the energy of the container. Most of the drop energy is lost in shock absorbers. Later on, a smaller drop test facility has been built on the ground but inside an existing building. It had to be controlled by prediction and measurements that the drop test will not damage the building. Tests from different heights on soft, medium, and stiff targets have been done to find out rules which allow to identify acceptable and unacceptable drop tests. Later on, the biggest drop test facility has been built for masses up to 200 t. It was necessary for the design of the foundation to estimate the forces which occur during the drop tests. On the other hand, the acceptable tests should be selected and controlled by measurements where the impact duration is important. Different sensors, accelerometers, accelerometers with mechanical filters, geophones (velocity transducers), strain gauges, and pressure cells have been applied for these tasks. The signals have been transformed to displacements which proved to be best suited for the interpretation of the impact mechanism. Modell calculations have been used to check and understand the dynamic measurements. The simplest law is the conservation of the momentum which is a good approximation if the impact is short. If the soil under the foundation has an influence on the deceleration of the container, the maximum foundation velocity is lower than the simple estimation. The amplitudes of the foundation could also be estimated from the ground vibrations and their amplitude-distance law.
Es wird die Vorgehensweise erläutert wie die Notwendigkeit einer elastischen Gebäudelagerung geprüft wird. Es werden die Möglichkeiten und Schwächen vereinfachter Rechenverfahren dargestellt. Es folgen weitere Beispiele detaillierter Gebäudemodelle und ihres Schwingungsverhaltens. Schließlich greift eine aktuelle Bachelorarbeit die Fragestellung komplexen Gebäudeschwingungsverhaltens auf. Die letzte Folie zeigt dazu Gebäudemodelle, die an die konkreten Erschütterungsprognosen anknüpfen.
Die Grundidee einer Schwingungsminderung ist es eine tiefe Eigenfrequenz der Struktur zu erreichen, so dass höhere Frequenzen abgemindert werden. Das gilt für die Minderung an der Quelle, zum Beispiel einem Eisenbahngleis, und für die Minderung am Empfänger, dem Gebäude. Die Eigenfrequenz ermittelt man aus dem Verhältnis der Auflagersteifigkeit und der Masse. Wie ist die Masse bei einem Gebäude zu wählen? Und wie ist die Untergrund-steifigkeit zu berücksichtigen? Als Referenzsituation ohne Minderungsma߬nahme? Der Beitrag bringt Rechenergebnisse zu abgefederten Gebäuden mit einfachen und komplexen (FE-) Modellen, Mess- und Rechenergebnisse zur Schwingungsübertragung von unabge-federten Gebäuden. Es wird der Einfluss der Abstimmfrequenz, der Bodensteifigkeit und der „starren“ Gebäudemasse untersucht. Die komplexen Gebäudemodelle erlauben, neben der Berechnung einer elastischen Gebäudelagerung, auch die Variation von Gebäudepara¬metern zur Reduktion der Deckenschwingungen. Den Ergebnissen bei der Erschütterungs-übertragung in Gebäude werden zwei ähnliche Beispiele zur elastischen Maschinenlagerung und zur elastischen Gleislagerung gegenübergestellt.
Erschütterungen durch Industrie und Verkehr, Schwingungen von Gebäuden, Fundamenten und Gleisen hängen im hohen Maße vom jeweiligen unterliegenden Boden ab. Die Eigenschaften des Bodens ermitteln wir mit Wellenmessungen vor Ort. Die Wellen werden in der Regel mit einem Impulshammer erzeugt und mit Geophonen als Schwinggeschwindigkeits-signale gemessen. Geophone sind aktive Sensoren, die eine kleine Messspannung liefern. Ein 72-kanaliges Messsystem mit entsprechenden Messverstärkern ist im Messwagen der Arbeitsgruppe eingebaut. Es werden im Vortrag fünf verschiedene Auswertemethoden vorgestellt. Im einfachsten Fall versucht man die Laufzeit von einem Geophon zum andern auszumessen und damit die vorherrschende Wellengeschwindigkeit zu ermitteln. Wir haben Wellengeschwindigkeiten von 30 m/s für Moorboden bis 1000 m/s für Felsboden gemessen. Der Boden hat aber nicht nur eine Wellengeschwindigkeit, sondern mehrere frequenzabhängige Wellen-geschwindigkeiten. Dadurch wird aus einem kurzen Hammerschlag eine längere Schwingung (Zerstreuung, Dispersion). Für die Auswertung von dispersiven Wellen nutzt man die spektrale Analyse, zunächst mit zwei Aufnehmern (SASW Spectral Analysis of Surface Waves), später mit einer ganzen Messachse (Multi-Station SASW). Schließlich kann man eine ganze Messachse auch mit verschiedenen Transformationsmethoden auswerten wie die f,v-Methode und Spatial AutoCorrelation SPAC Methode. Alle diese Methoden wurden von uns auf Messreisen in Deutschland, Österreich und der Schweiz getestet. Durch die Approximation der frequenzabhängigen Wellengeschwindigkeiten erhält man ein passendes Bodenmodell. Zu diesem Bodenmodell kann man die Übertra¬gungsfunktionen für Hammer- und Zuganregung berechnen. Bei etlichen Mess¬orten wurden deutliche Merkmale einer Bodenschichtung beobachtet. Es ergibt sich eine Reduktion der tiefen Frequenzanteile durch den steifen unterliegenden Halbraum. Die weiche Deckschicht bestimmt das hochfrequente Verhalten.
The present contribution evaluates four measuring series made by the Federal Institute of Material Research and Testing for the relations between train speed and ground vibration amplitudes. This experimental evaluation is supported by the simulation of the train passages at the different sites by using appropriate excitation mechanisms and forces as well as layered soil models which have been derived from impact measurements at each site.
Die Bundesanstalt für Materialforschung und -prüfung hat in den letzten 30 Jahren an vielen Orten Bahnerschütterungen gemessen. Dabei wurden immer auch Versuche zur Bestimmung der Bodeneigen-schaften durchgeführt, meist mit Hammeranregung, gelegentlich auch mit Schwingeranregung. Es werden verschiedene Auswertemethoden wie Seismogramm-Montage, Spektrale Analyse (SASW), Multistation Analysis of Surface Waves (MASW), f,v-Analyse (Dispersion aus zweifacher Fourier-Analyse), Spatial AutoCorrelation (SPAC, hier auch für deterministische Quellen) vorgestellt. Durch Approximation der frequenzabhängigen Wellengeschwindigkeiten (Dispersion) oder der gemessenen Übertragungsfunktionen erhält man ein passendes Bodenmodell. Zu diesem Bodenmodell kann man dann die Übertragungsfunktionen für Hammer- und Zuganregung berechnen. Mit allgemeinen oder spezifischen Achslastspektren werden dann die Bahnerschütterungen prognostiziert und mit den Messergebnissen verglichen. Bei etlichen Messorten, insbesondere in der Schweiz, wurden deutliche Merkmale einer Bodenschichtung beobachtet. Es ergibt sich eine deutliche Reduktion der tiefen Frequenzanteile durch den steifen unterliegenden Halbraum. Die weiche Deckschicht bestimmt das hochfrequente Verhalten. Hier bewirkt die Materialdämpfung des Bodens oft einen starken Amplitudenabfall, sowohl mit der Entfernung als auch mit der Frequenz. Für den verbleibenden mittelfrequenten Anteil wurde an mehreren Messorten die Amplituden-Fahrgeschwindigkeits-Gesetzmäßigkeiten untersucht. Es gibt konstante bis stark ansteigende Amplituden, und es zeigt sich auch hier, dass der geschichtete Boden von entscheidender Bedeutung ist.
Mitigation measures of railway induced vibration have been demonstrated at the emission, transmission and immission part. It must be carefully observed that the correct masses and stiffnesses are used.
Typical mistakes have been shown,
- 1D models for vehicle-track interaction,
- impedance instead of stiffness for the infill material of a trench,
- rigid buildings or neglecting the soil-building interaction.
The dominant mid-frequency part of the ground vibration is due to the irregular soil.
Measured train passages and hammer impacts in combination with track-soil calculation have been successfully used for the detection of damaged slab tracks. This approach is now extended to intact slab and ballast tracks. The vibrations of many tracks have been measured at several levels from rail, sleeper, track plate, base plate, base layer to the subsoil by velocity or acceleration sensors. The time histories have to be integrated once or twice to get the displacements. The displacement signals include an arbitrary time-dependent shift which must be eliminated or respected in the interpretation. On the other hand, the calculation of slab and ballast tracks have been done in frequency-wavenumber domain. The displacements along the track and the frequency-dependent compliance transfer functions can be calculated. The latter can be compared with the results of the hammer impacts on the track. The deformation of the track can be transformed to time histories for a whole train and compared to the measured train passages. Many slab (and ballast) tracks have been measured at different sites. The displacements of the tracks are presented, and the following parameters have been analysed in the measurement results: slab track vs. ballast track, different types of slab tracks, damaged slab tracks, different trains, switches at different measuring points, an elastic layer, the mortar layer, different soils at different places. The soil should have the dominant influence on the track-plate displacements. Slab and ballast track yield also big differences in maximum displacement and width of deformation. Some of the preceding aspects will be analysed in comparison of measurement and theory.