Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (26) (entfernen)
Schlagworte
- Slab track (6)
- Field tests (5)
- Hammer impact (5)
- Ground vibration (4)
- Railway track (4)
- Track damage (4)
- Track-soil interaction (4)
- Train passage (4)
- Vibration measurements (3)
- Amplitude-distance laws (2)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (9)
- 7.2 Ingenieurbau (9)
Eingeladener Vortrag
- nein (2)
The attenuation of technically induced surface waves is studied theoretically and experimentally. In this paper, nineteen measurements of ground vibrations induced by eight different technical sources including road and rail traffic, vibratory and impulsive construction work or pile driving, explosions, hammer impulses and mass drops are described, and it is shown that the technically induced ground vibrations exhibit a power-law attenuation ν ~ r -q where the exponents q are in the range of 0.5 to 2.0 and depend on the source types. Comparisons performed demonstrate that the measured exponents are considerably higher than theoretically expected. Some potential effects on ground vibration attenuation are theoretically analyzed. The most important effect is due to the material or scattering damping. Each frequency component is attenuated exponentially as exp(-kr), but for a broad-band excitation, the sum of the exponential laws also yields a power law but with a high exponent. Additional effects are discussed, for example the dispersion of the Rayleigh wave due to soil layering, which yields an additional exponent of 0.5 in cases of impulsive loading.
The damage detection and repair control have become important tasks for ballast and slab tracks. Measurements which compare the damaged and the repaired status of the same track section at different times, or which compare a damaged and an intact track section at the same time, have been successfully performed at some sites in Germany with slab tracks and ballast tracks and compared with the theoretical behaviour of intact and damaged tracks. The loss of contact between the sleeper and the plate, between the plate and the base layer, and some problems with soft or weakened soil have been analysed. The observed results, changes in the time histories of displacements and velocities due to train passages and in the transfer functions (compliances) due to hammer impacts, are encouraging that these measurements can be used to detect track damage. In addition, calculations with the combined finite-element boundary-element method have been used to confirm the conclusions about intact or damaged railway tracks.
A survey of the phenomena and methods for floor vibrations is presented. Experimental results of floor vibrations are shown for many floors in six different buildings. The signals have been evaluated for waves and modes by simple procedures. General rules have been established between the material and the area of a specific floor, and its local eigenfrequency. The damping values of the floor vibrations have been found between D = 1 and 10 % where somewhat higher values have been measured for wooden floors, and a weak correlation with the eigenfrequency has been established. The velocities of bending waves propagating in a storey and the attenuation with distance in the building have been analysed. A considerable transfer of vibration from one room to far away parts of the building has been found in the studied buildings with concrete and wooden floors. An example building has been analysed for modes of coupled floor bays. The strong coupling of similar neighbouring floor bays would yield a wide band of global resonance frequencies. The measured wooden floor exhibits a weak coupling of the neighbouring floor bays and a narrower band of eigenfrequencies. A special method has been tested with the impulse measurements to estimate the coupled eigenmodes in presence of the high damping. From the ambient measurement, a low-frequency vibration mode has been detected which includes the vibration of the whole building and the soil. The coupling of floors to other floors and the whole building is an important phenomenon of structural dynamics which should be observed for the prediction of vibration due to internal and external sources.
Ground vibrations due to different technical sources are analysed in theory and experiment for the dispersion of Rayleigh waves and the admittance spectra. Both tasks are theoretically based on the same concept: The admittance function in frequencywavenumber domain yields the dispersion as its maxima, and the admittance function in space domain is obtained by integrating it over the wavenumbers. On the experimental side, many signal processing methods have been applied to many sites and have been developed by the authors in the last 35 years, i.e., time-domain methods, including the cross-correlation method, and frequency-domain methods such as the spectral analysis of surface waves with two or multiple sensors, the wavenumber-transform method, and the spatial autocorrelation method. All methods are presented by their basic formula and by at least one example site. Different sensor arrays and deterministic and stochastic sources have been tested for the spatial autocorrelation method and the wavenumber-transform method at several sites. In addition, all frequency-domain methods are presented for a specific layered site comparing their quality. The evaluated dispersion curves are very similar, but a somewhat higher frequency range has been found for the fastest method, i.e., the multi-sensor spectral-analysis-of-surface-waves method. The theoretical solutions have been used for the inversion of the measured dispersion to the soil profile of the specific layered soil. The theoretical soil model has subsequently been used to predict the ground vibration spectra of hammer and railway excitation that exhibit a good agreement with the corresponding measurements. Thus, the contribution shows the benefit of active and passive seismic methods for the prediction of railway vibration, including a new version of the spatial autocorrelation method for technical vibrations. On the other hand, technical and namely railway vibrations are considered a seismic source for the exploration of near surface soils.
This contribution presents experimental methods to detect track damage. At BAM (Federal Institute of Material Research and Testing), a measuring car with a measuring system of 72 channels, geophones, mountings, cables, harmonic and impulsive exciters is used for dynamic measurements of the track, the soil and buildings. An instrumented hammer allows force measurements and to evaluate transfer functions of the track, and the soil. Wave measurements are used to identify the soil characteristics. Train passages are measured at the track and for the train induced ground vibrations. In addition to these in situ options, tests of tracks or track elements can be performed in a large laboratory.
This contribution intends to give an overview on the vibration behaviour of slab tracks in comparison of measurements and calculations and also by comparison of different track types at more than ten different measuring sites.
In theory, tracks on continuous soil are calculated by the frequency-wavenumber domain method. In experiment, geophone measurements are transformed to displacement results. Two aspects of track behaviour are considered, the frequency-dependant compliance of the track, measured by hammer impact, and the deflection under a passing axle load. In theory, the response to a single axle can be calculated, whereas in experiment, only the passage of the whole train can be measured. For comparison of theory and experiment, the calculated deflection under a single axle is superposed to get the response of the whole train. As a result, the slab track characteristics are completely different from the ballast track characteristics where each axle can be seen in the time histories. The slab track has a more global behaviour where only a whole bogie can be found in the track response and moreover, the two neighbouring bogies are not completely separated. The measurement of the different track elements (rail, sleeper, track plate, base layer) and the frequency-dependant compliances with possible resonances yield further information About the properties of the track elements. The calculations show that the soil has the dominant influence on the amplitudes and the width of the track-plate displacements. In the measurement results, the following
parameters are analysed: slab track vs. ballast track, different types of slab tracks, damaged slab tracks, different trains, switches at different measuring points, voided sleepers, an elastic layer, the mortar layer, and different soils at different places. Finally, a good agreement between measured and calculated results is found for the normal and some special (damaged, floating) slab tracks.