Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (52)
- Beitrag zu einem Tagungsband (47)
- Vortrag (46)
- Beitrag zu einem Sammelband (19)
- Posterpräsentation (4)
- Buchkapitel (1)
- Forschungsbericht (1)
Sprache
- Englisch (170) (entfernen)
Schlagworte
- Ground vibration (38)
- Layered soil (12)
- Slab track (11)
- Railway track (10)
- Mitigation (9)
- Track-soil interaction (9)
- Train passage (9)
- Vehicle-track interaction (9)
- Finite-element boundary-element method (8)
- Hammer impact (8)
- Building vibration (7)
- Layered soils (7)
- Train-induced ground vibration (7)
- Vibration measurements (6)
- Excitation forces (5)
- Field tests (5)
- Track vibration (5)
- Train speed (5)
- Vehicle-track-soil interaction (5)
- Container loading (4)
- Drop test (4)
- Finite element method (4)
- Force transfer (4)
- Foundation load (4)
- Railway (4)
- Soil-building interaction (4)
- Track damage (4)
- Wavenumber integrals (4)
- Attenuation (3)
- Axle impulses (3)
- Axle sequence (3)
- Ballast track (3)
- Base isolation (3)
- Continuously inhomogeneous soils (3)
- Filter effects (3)
- Irregular soil (3)
- Irregularities (3)
- Measurement (3)
- Measurements (3)
- Pile bending stiffness (3)
- Pile foundation (3)
- Prediction (3)
- Railway bridge (3)
- Randomly heterogeneous soil (3)
- Scattering (3)
- Soil stiffness (3)
- Train passages (3)
- Wind energy tower (3)
- ground vibration (3)
- mitigation (3)
- railway track (3)
- 2-span bridge (2)
- Achsfolgespektren (2)
- Amplitude-distance laws (2)
- Apartment building (2)
- Axle box measurements (2)
- Axle-sequence spectrum (2)
- Ballast tracks (2)
- Bauteile (2)
- Bauwerke (2)
- Boundary element method (2)
- Bridge resonance (2)
- Brücken (2)
- Displacements (2)
- Dynamic testing (2)
- Environmental vibrations (2)
- Evaluation (2)
- Finite element models (2)
- Floating slab track (2)
- Foundations (2)
- Freight train (2)
- Ground vibration measurements (2)
- Hammer tests (2)
- High-speed train (2)
- High-speed trains (2)
- Irregular ballast (2)
- Modalanalyse (2)
- Office tower (2)
- Passenger train (2)
- Plate-soil interaction (2)
- Rail roughness (2)
- Railway measurement campaign (2)
- Railway tracks (2)
- Railway tunnel (2)
- Railway vibration (2)
- Railways (2)
- Rayleigh wave (2)
- Resonance (2)
- Scattered axle impulses (2)
- Soil properties (2)
- Soil-structure interaction (2)
- Soil-wall-floor model (2)
- Static axle loads (2)
- Surface line (2)
- Surface-tunnel reduction (2)
- Track damage monitoring (2)
- Train excitation (2)
- Under-ballast plate (2)
- Varying track stiffness (2)
- Vehicle–track interaction (2)
- Vibration measurement (2)
- Vibration reduction (2)
- Wave excitation (2)
- Wavenumber method (2)
- floor vibration (2)
- modal analysis (2)
- track-soil interaction (2)
- undersleeper (2)
- wave analysis (2)
- 1-D insertion loss (1)
- Amplitude-charge weight laws (1)
- Amplitude-distance law (1)
- Assessment (1)
- Axle loads (1)
- Axle pulses (1)
- Axle-load spectra (1)
- Axle-sequence (1)
- Ballast mat (1)
- Beam dynamics (1)
- Beam-soil interaction (1)
- Bending waves (1)
- Blasting charge (1)
- Boundary element (1)
- Boundary elements (1)
- Bridge (1)
- Bridge track (1)
- Bridge vibration (1)
- Building response (1)
- Cancellation (1)
- Cars (1)
- Column/wall resonance (1)
- Combined finite-element boundary-element method (1)
- Compliance function (1)
- Components of excitation (1)
- Continuous soil (1)
- Damage detection (1)
- Damping (1)
- Dispersion (1)
- Doppler effect (1)
- Downburst (1)
- Drop height (1)
- Dynamic axle loads (1)
- Dynamic loads (1)
- Dynamic pile and pile group stiffness (1)
- Elastic length (1)
- Elastic track elements (1)
- Emission (1)
- Experimental verification (1)
- Explicit Green´s functions (1)
- Explosion (1)
- Explosion-induced ground vibrations (1)
- FEBEM and simplified methods (1)
- Fequency domain (1)
- Filter effect of the soil (1)
- Finite element (1)
- Finite-element boudnary-element method (1)
- Finite-element method (1)
- Flexibility (1)
- Flexible car body (1)
- Flexible plate (1)
- Flexible wheelset (1)
- Floor amplification (1)
- Floor resonance (1)
- Floors (1)
- Footbridge (1)
- Foundation reduction (1)
- Frequency response function (1)
- Frequency-specific attenuation (1)
- Frequency-wavenumber method (1)
- Geometric trackbed irregularities (1)
- Geometric vehicle and track irregularities (1)
- High-Rise Building (1)
- High-rise buildings (1)
- Inertial Interaction (1)
- Inertial interaction (1)
- Inhomogeneous soils (1)
- Insertion loss (1)
- Interaction (1)
- Interior load (1)
- Kinematic Interaction (1)
- Kinematic and inertial soil-pile-building (1)
- Kinematic interaction (1)
- Laboratory tests (1)
- Long-span bridge (1)
- MASW (1)
- Mass drop (1)
- Material damping (1)
- Measured railway vibrations (1)
- Measurement campaigns (1)
- Mitigation measures (1)
- Modal analysis (1)
- Modal force spectrum (1)
- Modal load spectrum (1)
- Modes (1)
- Modes and waves (1)
- Monitoring (1)
- Movin load test (1)
- Moving load (1)
- Moving loads on tracks (1)
- Multi-beam method (1)
- Multi-beam model (1)
- Multi-beam track model (1)
- Multi-beam-on-support model (1)
- Non-synoptic wind event (1)
- Obstacles (1)
- Office building (1)
- Overhead transmission line (1)
- Parametric excitation (1)
- Pile Foundation (1)
- Pile foundations (1)
- Pile groups (1)
- Pile-soil interaction (1)
- Prediction of explosion induced ground and building vibration (1)
- Prediction software (1)
- Predictions (1)
- Propagation from a tunnel (1)
- Quasi-static response; (1)
- Radiation damping (1)
- Rail pad (1)
- Railbridge (1)
- Railway forces (1)
- Railway induced ground vibration (1)
- Railway induced vibration (1)
- Railway track vibration (1)
- Railway trafiic (1)
- Random dynamics and vibrations (1)
- Random stiffness variation (1)
- Reduction (1)
- Residential building (1)
- Rigid vehicle model (1)
- SASW (1)
- SPAC (1)
- Scattering damping (1)
- Simple and fast prediction (1)
- Simple prediction (1)
- Sleeper pad (1)
- Sleeper passage (1)
- Soft track elements (1)
- Soil forces (1)
- Soil transfer function (1)
- Soil-building resonance (1)
- Soil-pile interaction (1)
- Soil-wall floor model (1)
- Static railway loads (1)
- Stiffness (1)
- Stiffness variation (1)
- Surface Foundation (1)
- Switch (1)
- Target stiffness (1)
- Track (1)
- Track alignment (1)
- Track and vehicle irregularities (1)
- Track beam (1)
- Track compliance (1)
- Track damage quantification (1)
- Track deflection (1)
- Track deformation (1)
- Track displacements (1)
- Track dynamic (1)
- Track filter (1)
- Track filtering (1)
- Track irregularities (1)
- Track-soil and vehicle-track resonances (1)
- Train configuration (1)
- Train induced ground vibration (1)
- Train-induced vibration (1)
- Tran speed (1)
- Transfer fuction (1)
- Transfer function (1)
- Trench (1)
- Tunnel (1)
- Tunnel line (1)
- Tunnel track (1)
- Tunnel vibration (1)
- Tunnel-pile transfer (1)
- Tunnel-to-surface reduction (1)
- Turnout (1)
- Under sleeper pad (1)
- Under sleeper pads (1)
- Under-sleeper pads (1)
- Varying soil stiffness (1)
- Varying stiffness (1)
- Vibration (1)
- Vibration excitation (1)
- Vibration isolation (1)
- Wave attenuation (1)
- Wave propagation (1)
- Wave theory of attenuation (1)
- Wave velocity (1)
- Wave-number integrals (1)
- Wavenumber domain (1)
- Waves (1)
- Wheel out-of-roundness (1)
- Wheelset (1)
- Wheelset accelerations (1)
- Wide sleeper (1)
- layered soil (1)
- sleeper pads (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (59)
- 7.2 Ingenieurbau (59)
Eingeladener Vortrag
- nein (46)
The propagation of waves through homogeneous or layered soil is calculated based on half-space theory. The moving dynamic loads of a train are approximated by fixed dynamic loads and the wave field can be calculated if the spectrum of the dynamic train loads is known. In addition to this dynamic wave field, there are three different components at three different frequency ranges which are caused by the passage of the static loads:
the regular static component at low frequencies,
the irregular static component at medium frequencies,
the sleeper-passing component at high frequencies.
For each of these components, an approximate solution is presented. The calculated wave field is compared with measurements of different trains at different sites. The measurement of impulse and harmonic point load excitation verifies the soil dynamic base of the method.
The Federal Institute of Material Research and Testing has performed many impact tests from very small laboratory tests to very big “free-field” tests with heavy containers on stiff foundations. The first measurements have been done on a big foundation where it should be guaranteed that the foundation is rigid and the container is tested properly. Later on, a smaller drop test facility has been built on the ground inside an existing building. It had to be controlled by prediction and measurements that the drop test will not damage the building. Tests from different heights on soft, medium, and stiff targets have been done to find out rules which allow to identify acceptable and unacceptable drop tests. Later on, the biggest drop test facility has been built for masses up to 200 t. It was necessary for the design of the foundation to estimate the forces which oc-cur during the drop tests. In addititon, the acceptable tests should be selected and controlled by measurements where the impact duration is important. Dif-ferent sensors, accelerometers, accelerometers with mechanical filters, geo-phones (velocity transducers), strain gauges, and pressure cells have been ap-plied for these tasks. Signal transformations and model calculations have been used to check and understand the dynamic measurements. The simplest law is the conservation of the momentum which is a good approximation if the impact is short. If the soil under the foundation has an influence on the deceleration of the container, the maximum foundation velocity is lower than the simple esti-mation.
The Federal Institute of Material Research and Testing has performed many impact tests from very small laboratory tests to very big “free-field” tests with heavy containers on stiff foundations. The first measurements have been done on a big foundation where it should be guaranteed that the foundation is rigid and the container is tested properly. Later on, a smaller drop test facility has been built on the ground inside an existing building. It had to be controlled by prediction and measurements that the drop test will not damage the building. Tests from different heights on soft, medium, and stiff targets have been done to find out rules which allow to identify acceptable and unacceptable drop tests. Later on, the biggest drop test facility has been built for masses up to 200 t. It was necessary for the design of the foundation to estimate the forces which oc-cur during the drop tests. In addititon, the acceptable tests should be selected and controlled by measurements where the impact duration is important. Dif-ferent sensors, accelerometers, accelerometers with mechanical filters, geo-phones (velocity transducers), strain gauges, and pressure cells have been ap-plied for these tasks. Signal transformations and model calculations have been used to check and understand the dynamic measurements. The simplest law is the conservation of the momentum which is a good approximation if the impact is short. If the soil under the foundation has an influence on the deceleration of the container, the maximum foundation velocity is lower than the simple esti-mation.
The maintenance of the transport infrastructures and their further development are going to remain focal points for investment and research in Germany in future. According to the latest development forecasts made by both the federal government and Deutsche Bahn, even if rail´s percentage share of the market were to remain unchanged, growth of around 50% would be expected in the next ten years, especially in freight traffic. This growth is necessitating considerable development both in the technical design of the tracks and in the abatement of the noise and vibration caused by railway traffic.
Vibration measurements have many causes and many technical and natural sources. Problems can sometimes be solved by short-term measurements, but in many cases, a long-term measurement is necessary. In long-term measurements of days, weeks, months and even years, it is easy to collect a huge quantity of raw data, but at the end, the post-processing of these data can be exhausting (for example one-year vibration data of a wind energy tower). A software has been developed which con-sists of measuring and evaluation routines where the measuring routines can operate different meas-uring systems and different measuring cards. The main advantage of this software is the fact that the interesting evaluations can be integrated in the measuring process so that the characteristics of the vibration can be extracted without storing all the raw data. Only important time segments are stored, for example train passages. The overall concept of the software and the main evaluation routines will be described in some details. Examples of our measurement experience will illustrate the capabilities of the software. 1) Surveying construction work in nearby sensitive buildings (for example an old wind tunnel), including a stable alarm system and meaningful vibration limits. 2) Prediction of train-induced vibration for a planned building to prevent annoyance and to improve the building design. 3) Modal analysis and long term measurements of several single- or multi-span, concrete or steel bridges 4) Modal and wave analysis of coupled floors in a historical building (“Neues Palais” at Potsdam). 5) Soil properties of various measurement sites (different routines to evaluate the dispersion). Moreover, from many projects, amplitudes, frequencies, and attenuation laws have been collected and analysed for the different sources such as vibratory or impact pile driving and ground compaction, demolition work with different machines, blasting in quarries and in tunnel works, bomb and mine clearing.
Vibration measurements have many causes and many technical and natural sources. Problems can sometimes be solved by short-term measurements, but in many cases, a long-term measurement is necessary. In long-term measurements of days, weeks, months and even years, it is easy to collect a huge quantity of raw data, but at the end, the post-processing of these data can be exhausting (for example one-year vibration data of a wind energy tower). A software has been developed which con-sists of measuring and evaluation routines where the measuring routines can operate different meas-uring systems and different measuring cards. The main advantage of this software is the fact that the interesting evaluations can be integrated in the measuring process so that the characteristics of the vibration can be extracted without storing all the raw data. Only important time segments are stored, for example train passages. The overall concept of the software and the main evaluation routines will be described in some details. Examples of our measurement experience will illustrate the capabilities of the software. 1) Surveying construction work in nearby sensitive buildings (for example an old wind tunnel), including a stable alarm system and meaningful vibration limits. 2) Prediction of train-induced vibration for a planned building to prevent annoyance and to improve the building design. 3) Modal analysis and long term measurements of several single- or multi-span, concrete or steel bridges 4) Modal and wave analysis of coupled floors in a historical building (“Neues Palais” at Potsdam). 5) Soil properties of various measurement sites (different routines to evaluate the dispersion). Moreover, from many projects, amplitudes, frequencies, and attenuation laws have been collected and analysed for the different sources such as vibratory or impact pile driving and ground compaction, demolition work with different machines, blasting in quarries and in tunnel works, bomb and mine clearing.
Measured train passages and hammer impacts in combination with track-soil calculation have been successfully used for the detection of damaged slab tracks. This approach is now extended to intact slab and ballast tracks. The vibrations of many tracks have been measured at several levels from rail, sleeper, track plate, base plate, base layer to the subsoil by velocity or acceleration sensors. The time histories have to be integrated once or twice to get the displacements. The displacement signals include an arbitrary time-dependent shift which must be eliminated or respected in the interpretation. On the other hand, the calculation of slab and ballast tracks have been done in frequency-wavenumber domain. The displacements along the track and the frequency-dependent compliance transfer functions can be calculated. The latter can be compared with the results of the hammer impacts on the track. The deformation of the track can be transformed to time histories for a whole train and compared to the measured train passages. Many slab (and ballast) tracks have been measured at different sites. The displacements of the tracks are presented, and the following parameters have been analysed in the measurement results: slab track vs. ballast track, different types of slab tracks, damaged slab tracks, different trains, switches at different measuring points, an elastic layer, the mortar layer, different soils at different places. The soil should have the dominant influence on the track-plate displacements. Slab and ballast track yield also big differences in maximum displacement and width of deformation. Some of the preceding aspects will be analysed in comparison of measurement and theory.
Measured train passages and hammer impacts in combination with track-soil calculation have been successfully used for the detection of damaged slab tracks. This approach is now extended to intact slab and ballast tracks. The vibrations of many tracks have been measured at several levels from rail, sleeper, track plate, base plate, base layer to the subsoil by velocity or acceleration sensors. The time histories have to be integrated once or twice to get the displacements. The displacement signals include an arbitrary time-dependent shift which must be eliminated or respected in the interpretation. On the other hand, the calculation of slab and ballast tracks have been done in frequency-wavenumber domain. The displacements along the track and the frequency-dependent compliance transfer functions can be calculated. The latter can be compared with the results of the hammer impacts on the track. The deformation of the track can be transformed to time histories for a whole train and compared to the measured train passages. Many slab (and ballast) tracks have been measured at different sites. The displacements of the tracks are presented, and the following parameters have been analysed in the measurement results: slab track vs. ballast track, different types of slab tracks, damaged slab tracks, different trains, switches at different measuring points, an elastic layer, the mortar layer, different soils at different places. The soil should have the dominant influence on the track-plate displacements. Slab and ballast track yield also big differences in maximum displacement and width of deformation. Some of the preceding aspects will be analysed in comparison of measurement and theory.
Measurements of downburst wind loading acting on an overhead transmission line in northern Germany
(2017)
Along an overhead transmission line in Northern Germany, a unique instrumentation of anemometers and force measurements is installed. Details of this test line with wind measurements along a horizontal axis are given. A recent event of a presumable downburst wind event is analyzed by means of available data and precedent works on thunderstorm analysis. The measured response of the conductors at the suspension tower is investigated and compared with time domain simulation of a finite element model.
Measurements on the vehicle-track interaction and the excitation of railway-induced ground vibration
(2017)
Two railway measurement campaigns have been performed in Germany and Switzerland which yield insight in the vehicle-track-soil interaction. The campaign in Germany has included simultaneous measurement of vehicle, track, and soil vibrations during train runs with 16, 25, 40, 63, 80, 100, 125, 140, 160 km/h, and impulse measurements of the passenger car, three track sections and the soil. Two ballast tracks, one on the soil surface and one on a concrete bridge, have been investigated as well as a slab track in a tunnel. Ten different sites in Switzerland have been measured for soil properties and train-induced ground vibrations, which allow to determine the excitation forces of the railway traffic. New axle-box measurements at some of the Swiss sites have been analysed to get further experimental evidence. All these measurements have been evaluated to characterize the excitation processes. Relations between vehicle vibration and ground vibration can be observed. The vehicle vibrations, namely the accelerations of the wheelsets, yield the dynamic forces due to the passage over the irregularities of the vehicle and the track. The ground vibrations are correlated to these dynamic forces to a certain extent. Some mid-frequency ground vibration amplitudes, however, are higher than expected from the dynamic excitation forces. The experimental observations can be explained by an irregular response to the passage of the static loads, that means the passage of the static loads over an irregular ballast or soil. This correct understanding of the excitation processes is important for the prediction as well as for the mitigation of railway induced ground vibrations.
Measurements on the vehicle-track interaction and the excitation of railway-induced ground vibration
(2017)
Two railway measurement campaigns have been performed in Germany and Switzerland which yield insight in the vehicle-track-soil interaction. The campaign in Germany has included simultaneous measurement of vehicle, track, and soil vibrations during train runs with 16, 25, 40, 63, 80, 100, 125, 140, 160 km/h, and impulse measurements of the passenger car, three track sections and the soil. Two ballast tracks, one on the soil surface and one on a concrete bridge, have been investigated as well as a slab track in a tunnel. Ten different sites in Switzerland have been measured for soil properties and train-induced ground vibrations, which allow to determine the excitation forces of the railway traffic. New axle-box measurements at some of the Swiss sites have been analysed to get further experimental evidence. All these measurements have been evaluated to characterize the excitation processes. Relations between vehicle vibration and ground vibration can be observed. The vehicle vibrations, namely the accelerations of the wheelsets, yield the dynamic forces due to the passage over the irregularities of the vehicle and the track. The ground vibrations are correlated to these dynamic forces to a certain extent. Some mid-frequency ground vibration amplitudes, however, are higher than expected from the dynamic excitation forces. The experimental observations can be explained by an irregular response to the passage of the static loads, that means the passage of the static loads over an irregular ballast or soil. This correct understanding of the excitation processes is important for the prediction as well as for the mitigation of railway induced ground vibrations.
A survey of the phenomena and methods for floor vibrations is presented. Experimental results of floor vibrations are shown for many floors in six different buildings. The signals have been evaluated for waves and modes by simple procedures. General rules have been established between the material and the area of a specific floor, and its local eigenfrequency. The damping values of the floor vibrations have been found between D = 1 and 10 % where somewhat higher values have been measured for wooden floors, and a weak correlation with the eigenfrequency has been established. The velocities of bending waves propagating in a storey and the attenuation with distance in the building have been analysed. A considerable transfer of vibration from one room to far away parts of the building has been found in the studied buildings with concrete and wooden floors. An example building has been analysed for modes of coupled floor bays. The strong coupling of similar neighbouring floor bays would yield a wide band of global resonance frequencies. The measured wooden floor exhibits a weak coupling of the neighbouring floor bays and a narrower band of eigenfrequencies. A special method has been tested with the impulse measurements to estimate the coupled eigenmodes in presence of the high damping. From the ambient measurement, a low-frequency vibration mode has been detected which includes the vibration of the whole building and the soil. The coupling of floors to other floors and the whole building is an important phenomenon of structural dynamics which should be observed for the prediction of vibration due to internal and external sources.
The ground vibrations, which are generated by trains on different tracks, have been calculated by finite-element boundary-element models. The ballasted track is modelled in detail by the finite element method. The infinite soil is modelled by the boundary element method as a homogeneous or layered half-space. The track-soil system is coupled to a simple rigid mass model of the vehicle so that the vehicle-track interaction is completely included. Transfer functions are calculated in frequency domain without and with vehicle-track interaction, the compliance of the track and the mobilities of the soil at different distances from the track. Finally, the ratios between the ground vibration amplitudes with and without mitigation measures are calculated to quantify the effectiveness of the mitigation measures.
Tracks with under-sleeper pads have been investigated in a wide parameter study for the RIVAS project. The main parameters that influence the reduction of ground vibration are the stiffness of the under-sleeper pad, the mass and the width of the sleeper. The softest sleeper pad yields the best reduction of the ground vibration. The influence of the sleeper mass is not so strong, as the characteristic frequency is ruled by the mass of the sleeper and the mass of the wheelset as well.
The ground vibrations, which are generated by trains on different slab tracks, have been calculated by finite-element boundary-element models. The slab track is modelled in detail by the finite element method.
The infinite soil is modelled by the boundary element method as a homogeneous half-space. The track-soil system is coupled with a simple rigid mass model of the vehicle so that the vehicle-track interaction is completely included. Transfer functions are calculated in frequency domain without and with vehicle-track interaction, the compliance of the track and the mobilities of the soil at different distances from the track.
Finally, the ratios between the ground vibration amplitudes with and without mitigation measure are calculated to quantify the effectiveness of the mitigation measure.
Tracks with under sleeper pads have been investigated in a parameter study. The main parameter that influences the reduction of ground vibration is the stiffness of the under sleeper pad. The softest sleeper pad yields the best reduction of the ground vibration.
The influence of other parameters has been examined. The stiffness of the rail pads, the stiffness of the slab material, the stiffness of the sleeper material, and the distance of the sleepers. All these parameters show no or only a minor influence on the mitigation effect.
As the standard isolated track, a track with an under sleeper pad of a stiffness of kS = 5 107 N/m has been chosen, which can also be expressed as a stiffness per area of kS ’’ = 3.7 107 N/m3 = 0.037 N/mm3.
The resonance frequency for this pad stiffness is observed between 32 and 40 Hz. The reduction of the ground vibration is about vi,I /vi,U = 0.1 at 100 Hz.
This contribution presents some principles and some examples of the mitigation of railway-induced ground vibrations. The principles are different for the mitigation measures at the track, in the soil or at the building. Force transfer functions of isolated and un-isolated track-soil systems, reflected and transmitted wave amplitudes at walls and trenches in the soil, and the transfer of the (free-field) vibration amplitudes to the foundation amplitudes of the building are analysed. The mitigation effect can be calculated by exact or simplified formulas. Some examples with 3D (finite-element boundary-element), 2D (beam-on-support), and 1D track models, 2D and 1D soil models, detailed 3D building models and finite or infinite 1D wall-floor models are investigated to find out if simple models can be used for a satisfactory prediction of the mitigation effect. The 1D track examples show that the force transfer of the track without vehicle can be exactly calculated, whereas the total force transfer can be calculated approximately if appropriate wheelset masses per track length are used for the isolated and the un-isolated track. The mitigation effect of a filled trench is calculated by a 2D finite element model and the results compare with simple transmission formula if the stiffness per area rather than the wave impedances are used for the infill material. The base isolation of a building is analysed by a detailed 3D model and the results are similar to the analytic results of a single wall with floors on the soil. Other reduction measures as different floor and column dimensions are usually less effective so that the clearly best mitigation solution at a building is a partly or a complete base isolation.
This contribution presents some principles and some examples of the mitigation of railway-induced ground vibrations. The principles are different for the mitigation measures at the track, in the soil or at the building. Force transfer functions of isolated and un-isolated track-soil systems, reflected and transmitted wave amplitudes at walls and trenches in the soil, and the transfer of the (free-field) vibration amplitudes to the foundation amplitudes of the building are analysed. The mitigation effect can be calculated by exact or simplified formulas. Some examples with 3D (finite-element boundary-element), 2D (beam-on-support), and 1D track models, 2D and 1D soil models, detailed 3D building models and finite or infinite 1D wall-floor models are investigated to find out if simple models can be used for a satisfactory prediction of the mitigation effect. The 1D track examples show that the force transfer of the track without vehicle can be exactly calculated, whereas the total force transfer can be calculated approximately if appropriate wheelset masses per track length are used for the isolated and the un-isolated track. The mitigation effect of a filled trench is calculated by a 2D finite element model and the results compare with simple transmission formula if the stiffness per area rather than the wave impedances are used for the infill material. The base isolation of a building is analysed by a detailed 3D model and the results are similar to the analytic results of a single wall with floors on the soil. Other reduction measures as different floor and column dimensions are usually less effective so that the clearly best mitigation solution at a building is a partly or a complete base isolation.
Long wooden floor beams above a ball room in an old historical palace have been analysed experimentally. The eleven beams are weakly coupled by three layers of floor boards. It has been investigated if the state (the stiffness) of the wooden beams can be determined by vibration measurements of global or preferably local modes. Hammer, heel-drop and ambient excitations have been used. The vibration modes of the structure show dominating local deformations if an impact excitation is applied. This is understood as the positive superposition of several modes which yield the maximum at the excitation point but a cancellation at more distant points. Natural modes have been estimated from these vibration modes by standard and special methods which were necessary for the high damping of the wooden floor. It has been found that all floor beams contribute to each natural mode even for a weak coupling of the beams. In addition to the modal discussion, the impact tests have also been analysed for the wave propagation and amplitude attenuation with distance. The coupling of floor beams has been studied theoretically by an analytic multiple-beam model where the coupling by translational or rotational springs and by a common support motion has been assumed.
Long wooden floor beams above a ball room in an old historical palace have been analysed experimentally. The eleven beams are weakly coupled by three layers of floor boards. It has been investigated if the state (the stiffness) of the wooden beams can be determined by vibration measurements of global or preferably local modes. Hammer, heel-drop and ambient excitations have been used. The vibration modes of the structure show dominating local deformations if an impact excitation is applied. This is understood as the positive superposition of several modes which yield the maximum at the excitation point but a cancellation at more distant points. Natural modes have been estimated from these vibration modes by standard and special methods which were necessary for the high damping of the wooden floor. It has been found that all floor beams contribute to each natural mode even for a weak coupling of the beams. In addition to the modal discussion, the impact tests have also been analysed for the wave propagation and amplitude attenuation with distance. The coupling of floor beams has been studied theoretically by an analytic multiple-beam model where the coupling by translational or rotational springs and by a common support motion has been assumed.
In the last three decades, the vibrations of many floors and bridges have been measured. The contribution shows some evaluation methods, experimental results and some modelling and theoretical results. Simple evaluation methods have been developed for single and coupled floors. Two coupled beams have been measured in good agreement with the theory. A more complex coupling model has been found for a large wooden floor in a castle consisting of six floor bays which correlates well with the measurements. Damaged and intact poles have been tested by their natural frequencies and damping values, and a fair correlation between the degree of damage and the shift of the frequency. Road bridges have been analysed in detail and some examples are presented. Railway bridges and trains are studied for resonant excitation. The risk of resonance can be estimated in frequency domain by using axle-sequence spectra of the train and the natural frequencies of the bridge. A measurement example shows the amplification, but even stronger the cancellation of the subsequent axle responses. Several high-speed trains and freight trains have been analysed for their potential resonance amplification.
In the last three decades, the vibrations of many floors and bridges have been measured. The contribution shows some evaluation methods, experimental results and some modelling and theoretical results. Simple evaluation methods have been developed for single and coupled floors. Two coupled beams have been measured in good agreement with the theory. A more complex coupling model has been found for a large wooden floor in a castle consisting of six floor bays which correlates well with the measurements. Damaged and intact poles have been tested by their natural frequencies and damping values, and a fair correlation between the degree of damage and the shift of the frequency. Road bridges have been analysed in detail and some examples are presented. Railway bridges and trains are studied for resonant excitation. The risk of resonance can be estimated in frequency domain by using axle-sequence spectra of the train and the natural frequencies of the bridge. A measurement example shows the amplification, but even stronger the cancellation of the subsequent axle responses. Several high-speed trains and freight trains have been analysed for their potential resonance amplification.
The present contribution evaluates four measuring series made by the Federal Institute of Material Research and Testing for the relations between train speed and ground vibration amplitudes. This experimental evaluation is supported by the simulation of the train passages at the different sites by using appropriate excitation mechanisms and forces as well as layered soil models which have been derived from impact measurements at each site.
The present contribution evaluates four measuring series made by the Federal Institute of Material Research and Testing for the relations between train speed and ground vibration amplitudes. This experimental evaluation is supported by the simulation of the train passages at the different sites by using appropriate excitation mechanisms and forces as well as layered soil models which have been derived from impact measurements at each site.
The present contribution evaluates four measuring series made by the Federal Institute of Material Research and Testing for the relations between train speed and ground vibration amplitudes. This experimental evaluation is supported by the simulation of the train passages at the different sites by using appropriate excitation mechanisms and forces as well as layered soil models which have been derived from impact measurements at each site.
Some results of our measurements of the Intercity experimental are presented together with simulated results and their interpretation. Three frequeny ranges could be measured and calculated: low frequencies which decrease very rapidly with distance (the quasi-static part), high frequencies (mainly due to the sleeper passage), and a mid-frequency which has the weakest attenuation with distance and is therefore dominant at the far field. Mono-frequent excitations get a wide frequency band due to the Doppler effect of the moving high-speed train.
Prediction of building noise and vibration – 3D finite element and 1D wave propagation models
(2021)
Construction work or traffic excite nearby buildings, and the perceptible or audible vibration can be a nuisance for the inhabitants. The transfer of the vibration from the free field to the building has been calculated by the finite element method for many models in consultancy and research work. The analysis for all storeys of certain building points such as walls, columns and floors unveiled some rules, some typical modes, and some wavetype responses. A simplified building-soil model has been created, which includes well these effects of building-soil resonance, wall/column resonance, floor resonances, and the high-frequency reduction. The model consists of one wall for a wall-type apartment building or a column for each specific part (mid, side or corner) of a column-type office building. The building response in the high-frequency (acoustic) region is calculated as mean values over all storeys and over wider frequency bands, by wave-type asymptotes of an infinitely tall building, and by the soil to wall ratio of impedances. The secondary noise is predicted by Transfer values between the building vibration (center of floors, walls at a room corner) and the sound pressure.
Prediction of building noise and vibration – 3D finite element and 1D wave propagation models
(2021)
Construction work or traffic excite nearby buildings, and the perceptible or audible vibration can be a nuisance for the inhabitants. The transfer of the vibration from the free field to the building has been calculated by the finite element method for many models in consultancy and research work. The analysis for all storeys of certain building points such as walls, columns and floors unveiled some rules, some typical modes, and some wavetype responses. A simplified building-soil model has been created, which includes well these effects of building-soil resonance, wall/column resonance, floor resonances, and the high-frequency reduction. The model consists of one wall for a wall-type apartment building or a column for each specific part (mid, side or corner) of a column-type office building. The building response in the high-frequency (acoustic) region is calculated as mean values over all storeys and over wider frequency bands, by wave-type asymptotes of an infinitely tall building, and by the soil to wall ratio of impedances. The secondary noise is predicted by Transfer values between the building vibration (center of floors, walls at a room corner) and the sound pressure.
Explosion-induced ground vibrations have been measured at several places. Results about the wave propagation are shown in this contribution. The particle velocities of the soil have been measured at up to 1000 m distance from the explosion and are presented as time records (seismograms) and one-third octave band spectra (transfer functions). The results are compared with the results of hammer impacts. The seismograms clearly show different wave types, compressional waves of the air, the water and the soil, and the Rayleigh wave. The hammer impacts yield good results up to 100 m and incorporate higher frequencies at about 50 Hz, whereas the explosion results in a ground vibration with frequencies around 10 Hz and a longer range of influence. Explosion and hammer excitations are evaluated for the wave velocities of the soil by using the wavenumber and the spatial auto-correlation method. The attenuation of the ground vibration amplitudes A with distance r can well be presented by a power law A ~ r -q. This type of amplitude-distance law and the corresponding power q > 1 are substantiated in the contribution. The influence of the charge weight W is evaluated as an additional power law A ~ W -p for each measuring site. The power is found quite similarly around q 0.6 as all sites have a medium soft soil such as sand and clay. The obtained amplitude-charge-distance law can be used to predict the explosion-induced ground and building vibrations at other sites.
A simple and fast prediction scheme is presented for train-induced ground and building vibrations. For the emission, finite-element boundary-element or multiple-beam-on-continuous-soil models of the track have been analysed and approximated by faster track-on-Winkler-soil models. The vehicle-track interaction due to irregularities yields the excitation forces. For the transmission of waves in the soil, the wavenumber integral of the compliance of layered soils has been evaluated. The calculation time is reduced for the prediction by using the solution of a homogeneous half-space with a frequency-dependent wave velocity (the dispersion) of the soil. For the immision, many 2 and 3-dimenisonal finite-element building models have been investigated, and a good approximation has been established by a 1-dimensional soil-wall-floor model. In addition, the axle sequence of the train, the quasi-static and the “scattered” response of the soil, and the wave propagation from a tunnel to a pile foundation of a building have been included.
A simple and fast prediction scheme is presented for train-induced ground and building vibrations. For the emission, finite-element boundary-element or multiple-beam-on-continuous-soil models of the track have been analysed and approximated by faster track-on-Winkler-soil models. The vehicle-track interaction due to irregularities yields the excitation forces. For the transmission of waves in the soil, the wavenumber integral of the compliance of layered soils has been evaluated. The calculation time is reduced for the prediction by using the solution of a homogeneous half-space with a frequency-dependent wave velocity (the dispersion) of the soil. For the immision, many 2 and 3-dimenisonal finite-element building models have been investigated, and a good approximation has been established by a 1-dimensional soil-wall-floor model. In addition, the axle sequence of the train, the quasi-static and the “scattered” response of the soil, and the wave propagation from a tunnel to a pile foundation of a building have been included.
Train passages induce static and dynamic forces on the track, the train-induced vibrations propagate through the soil and excite neighbouring buildings. The problem of train vibrations is divided into the parts emission, which is the excitation by railway traffic (the present contribution), transmission, which is the wave propagation through the soil, and immission, which is the transfer into a building, - The calculation of the axle loads are based on the vehicle-track-soil interaction. This interaction uses the dynamic stiffness of the vehicle (the inertia of the wheelset) and the dynamic stiffness of the track-soil System. Based on various time consuming finite-element boundary-element calculations, an approximate track-soil model has been established. The vehicle-track-soil analysis yields several transfer functions between the various geometric or stiffness irregularities and the axle loads of the train. Geometric irregularities of the vehicle (the wheels) and the track (rail surface and track alignment) are the simplest components. Geometric irregularities of the subsoil (trackbed irregularities) have to be transferred to effective irregularities at rail level. The bending stiffness of the track is filtering out the short-wavelength contribution. Stiffness irregularities occur due to random variations in the bailast or the subsoil, which must also be transferred to effective track irregularities, and due to the discrete rail support on sleepers. The axle loads due to the effective track errors from stiffness variations have their specific vehicle-track transfer function. - All necessary formula for the prediction of axle-load spectra will be presented. The prediction method is compared with axle-box measurements at a Standard ballasted track. Moreover, ground Vibration measurements at numerous sites are exploited for the axle-load spectra and the Validation of the prediction method.
Train-induced ground vibrations are generated by static and dynamic axle loads which can be calculated by vehicle-track-soil models and the vehicle and track irregularities. A fast prediction method has been developed which uses approximate transfer functions of layered soils. In the present contribution, this prediction method is used for the inverse calculation of the axle-load spectra from the measured ground vibration. The layered soils of some measuring sites show very differing ground vibration spectra in the amplitude range of 0.0001–1.0 mm/s as a consequence of the soft layer and stiff half-space, differing layer frequencies, as well as the far- and near-field measuring points. The back-calculation, however, yields axle-load spectra within a single order of magnitude around 1 kN. Axle-box measurements confirm the amplitude level of the axle loads. This standard axle-load spectrum can be used for a basic prediction at a new site. The separation of train and site-specific components allows a better evaluation of railway vibrations, for example, of different trains and different tracks. By eliminating the effects of differing soil characteristics, an important mid-frequency component has been found which lies between 8 and 32 Hz depending on the train speed. The origin of this dominant mid-frequency component is discussed using advanced prediction methods like moving constant loads, scattered axle impulses and axle-sequence spectra.
The reduction in train-induced ground vibrations by different railway lines and by mitigation measures in the propagation path was analysed in a unified approach by two-dimensional finite element calculations. In general, there was no reduction at low frequencies, and the reduction be-came stronger with increasing frequencies. A maximum reduction of 0.1 at high frequencies was established with an open trench. Reductions between 0.7 and 0.2 have been found for the other sit-uations, filled trenches, walls, plates, and blocks, as well as for railway lines on dams, in cuts and in a tunnel. Bridges can produce amplifications due to their resonance frequencies, but also strong reductions due to massive bridge piers. The influence of some parameters has been analysed, such as the bridge span, the inclination of the dam and the cut, the stiffness of the soil, and the tunnel structure. The dynamic track stiffnesses of a surface, bridge, and tunnel track have been calculated using the 3D finite-element boundary-element method for comparison with corresponding meas-urements.
In this article, the passage of different trains over different bridges will be studied for resonant excitation. The intensity of the resonance will be estimated in frequency domain by using three separated spectra. At first, the excitation spectrum of the modal forces is built by the mode shape and the passage time of the train over the bridge. The second spectrum is the frequency response function of the bridge which include the modal frequency, damping and mass. The third part is the spectrum of the axle sequence of the train. The influences of train speed, bridge length, bridge support, track irregularities, and train type on the resonance amplitudes will be analysed for each of these spectra separately for getting a better insight. A variety of axle-sequence spectra and corresponding rules will be presented for different vehicles and trains. As examples, the passage of a slow freight train over a long-span bridge, a normal passenger train over a medium-span bridge, and a high-speed train over a short bridge will be analysed. Corresponding measurements show the amplification, but also the cancellation of the subsequent axle responses. Namely in one of the measurement examples, the first mode of the bridge was amplified and the second mode was cancelled at a low speed of the train and vice versa at a higher speed.
The soilstructure interaction of elastic plates on homogeneous or layered soils excited by horizontally propagating waves is analysed. Large plates are modelled by a combined finite-element boundary-element method (FEBEM), whereas the response of infinitely long plates is calculated by a numerical integration in the frequencywavenumber domain. The finite-element boundary-element method yields the complete soilplate transfer function of frequency and distance whereas the frequencywavenumber solution of the infinitely long plate can serve as an approximation for long distances on a finitely long plate. The soilplate transfer function starts to decrease strongly at the coincidence frequency, where the bending stiffness equals the plate inertia. A strong decrease follows at mid frequencies and a strong reduction of less than 0.1 of the ground vibration is reached at high frequencies. Rules for the characteristic frequencies are derived from the numerical results clearly indicating the strongest influence of the soil stiffness and the weaker influence of the bending stiffness of the plate. The influence of the mass, length and width of the plate are shown to be limited in case of realistic parameters, but it should be noted that the reduction effects are less effective for layered soils and for nearer observation points.
Two measurement campaigns of train-induced ground vibrations are evaluated for the vehicle-track-soil interaction. Ground vibrations, track vibrations and vehicle vibrations have been measured for train passages and impulse excitation and compared with theoretical results. The soil and the track-soil system are calculated by wavenumber integrals. The influence of the vehicle is introduced by a substructure method. By comparing theory and measurement the different components of excitation force and ground vibration can be analysed, the quasi-static excitation, track-alignment errors, the out-of-roundness of wheels, the wheel and rail roughness, and moreover, scattered axle impulses and ineffective high-frequency parts of the wheelset accelerations and forces.
Seismic reponse of three-dimensional structures using a Green's function approach to the soil
(1986)
Seismic response of three-dimensional structures using a green's function approach to the soil
(1986)