Filtern
Erscheinungsjahr
- 2023 (14)
- 2022 (11)
- 2021 (9)
- 2020 (10)
- 2019 (12)
- 2018 (3)
- 2017 (15)
- 2016 (7)
- 2015 (9)
- 2014 (3)
- 2013 (5)
- 2012 (4)
- 2011 (4)
- 2010 (7)
- 2009 (4)
- 2008 (6)
- 2007 (6)
- 2006 (6)
- 2005 (8)
- 2004 (5)
- 2003 (1)
- 2002 (2)
- 2001 (1)
- 2000 (1)
- 1998 (1)
- 1997 (3)
- 1996 (1)
- 1995 (2)
- 1994 (1)
- 1991 (2)
- 1990 (1)
- 1989 (2)
- 1986 (3)
- 1984 (1)
Dokumenttyp
- Zeitschriftenartikel (52)
- Beitrag zu einem Tagungsband (47)
- Vortrag (46)
- Beitrag zu einem Sammelband (19)
- Posterpräsentation (4)
- Buchkapitel (1)
- Forschungsbericht (1)
Sprache
- Englisch (170) (entfernen)
Schlagworte
- Ground vibration (38)
- Layered soil (12)
- Slab track (11)
- Railway track (10)
- Mitigation (9)
- Track-soil interaction (9)
- Train passage (9)
- Vehicle-track interaction (9)
- Finite-element boundary-element method (8)
- Hammer impact (8)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (59)
- 7.2 Ingenieurbau (59)
Eingeladener Vortrag
- nein (46)
The effect of critically moving loads on the vibrations of soft soils and isolated railway tracks
(2008)
The dynamic response of the railway track is strongly influenced by the underlying soil. For a soft soil and very high train speeds or for a very soft soil and regular train speeds, the train speed can be close to the speed of elastic waves in the soil. This paper presents a detailed study of the so-called moving-load effect, i.e. an amplification of the dynamic response due to the load movement, for the tracks on soft soil. The analysis is carried out by evaluating the related integrals in the wavenumber domain. The influence of the load speed is quantified for a large set of parameters, showing that the effect on the soil vibration is reduced with increase of the frequency, track width and inverse wave velocity. Therefore, the moving-load effect associated with vibratory train loads is negligible whereas the amplification associated with the moving dead weight of the train can be significant. The strong moving-load effect on a perfectly homogeneous soil, however, can be strongly diminished by a layered or randomly varying soil situation. This theoretical result is affirmed by measurements at a test site in Germany where the trains run on a very soft soil at a near-critical speed. The results for soft soils are compared with experimental and theoretical results for a stiff soil. It is found that the influence of the stiffness of the soil is much stronger than the moving-load effect. This holds for the soil vibration as well as for the track vibration which both show a minor dependence on the load speed but a considerable dependence on the soil stiffness in theory and experiment.
Railway tracks can include soft isolation elements such as rail pads, sleeper shoes and ballast mats. For these types of isolation elements and normal soil conditions, the influence of the load speed is usually negligible. There is only one isolation measure for which the moving load may be effective: a track which is constructed as a heavy massspring system. The resonance of this track system is shifted to lower frequencies and amplitudes for increasing train speed. A critical train speed can be reached if the massspring system has a marginal bending stiffness along the track.
A finite-element boundary-element software for the dynamic interaction of flexible structures and the soil has been extended for pile foundation. The boundary element method for the soil uses the Green´s functions of the layered half-space which have been generalised for interior loads. Pile groups of 10 to 20 piles of different arrays are analysed and compared with single piles. Simplified models have been developed for a user-friendly, practice oriented prediction software for railway induced ground and building vibration.
A method is presented which allows to calculate the wave-field in a homogeneous or layered soil in case of a dynamic interior load. The wave propagation along the surface, the distribution of the response over the depth, the horizontal propagation at different depths and the vertical downward propagation are shown and compared with the simpler surface solution of the half-space and the interior solution of the full-space. The complete wave-field (Green's function) is applied to the dynamic behaviour of piles and pile groups by use of a boundary element formulation. The stiffness, damping and – typically for piles – mass of different groups of piles are presented. Different group effects occur for lines, circles, grids, parallels and crosses of piles, which can be regarded as oscillations around average values. Moreover, the piles and pile groups behave almost like a damper for most of the frequencies. A building on a pile group that is excited by ground vibration due to surface or interior loads shows a reduction of the wave-field due to kinematic and inertial soil–building interaction effects. The results presented lead to simplified descriptions of the wave-field due to interior loads and of the soil–pile–building interaction which can be used for the prediction of technically induced vibration.
Transfer admittance spectra of technically induced surface wave fields are analyzed in theory and experiments. Theoretical admittance spectra of layered soils are obtained by integration in wavenumber domain and compared with experimental admittances due to hammer or vibrator excitation. The admittance spectra are strongly influenced by the layering and damping of the soil. Deep stiff-soil layers yield a low-frequency cutoff, whereas a strong damping yields a high-frequency cutoff. A sharp cutoff in a narrow frequency band, which is measured at some sites, can be explained by a damping that increases with frequency, such as viscous material or scattering damping.
Excitation force spectra are necessary for a realistic prediction of railway-induced ground vibration. The excitation forces cause the ground vibration and they are themselves a result of irregularities passed by the train. The methods of the related analyses - the wavenumber integration for the wave propagation in homogeneous or layered soils, the combined finite-element boundary-element method for the vehicle-track-soil interaction - have already been presented and are the base for the advanced topic of this contribution. This contribution determines excitation force spectra of railway traffic by two completely different methods. The forward analysis starts with vehicle, track and soil irregularities, which are taken from literature and axle-box measurements, calculates the vehicle-track interaction and gets theoretical force spectra as the result. The second method is a backward analysis from the measured ground vibration of railway traffic. A calculated or measured transfer function of the soil is used to determine the excitation force spectrum of the train. A number of measurements of different soils and different trains with different speeds are analysed in that way. Forward and backward analysis yield the same approximate force spectra with values around 1 kN for each axle and third of octave.
The attenuation of the amplitudes with distance of technically induced surface wave fields is analyzed in theory and experiments. Experimental results of technically induced ground vibration are presented and collected from literature, which show a power-low attenuation A ~ r–q of amplitudes A with distance r and exponents q > 0.5 higher than for elastic surface waves. Additional attenuation effects are analyzed theoretically. The most important effect is due to the material or scattering damping. Each frequency component is attenuated exponentially as A ~ exp(–kr), but for a broadband excitation, the sum of the exponential laws yields a power law with a higher exponent. Some more effects are discussed, for example the dispersion of the Rayleigh wave due to the layering of the soil, which yields a stronger attenuation A ~ r–q–dq, including an additional exponent of dq = 0.5 in case of an impulsive loading.
The attenuation of technically induced surface waves is studied theoretically and experimentally. In this paper, nineteen measurements of ground vibrations induced by eight different technical sources including road and rail traffic, vibratory and impulsive construction work or pile driving, explosions, hammer impulses and mass drops are described, and it is shown that the technically induced ground vibrations exhibit a power-law attenuation ν ~ r -q where the exponents q are in the range of 0.5 to 2.0 and depend on the source types. Comparisons performed demonstrate that the measured exponents are considerably higher than theoretically expected. Some potential effects on ground vibration attenuation are theoretically analyzed. The most important effect is due to the material or scattering damping. Each frequency component is attenuated exponentially as exp(-kr), but for a broad-band excitation, the sum of the exponential laws also yields a power law but with a high exponent. Additional effects are discussed, for example the dispersion of the Rayleigh wave due to soil layering, which yields an additional exponent of 0.5 in cases of impulsive loading.
Construction work, such as pile driving and soil compaction, or road and railway traffic excite nearby buildings, and the perceptible or audible vibration can be a nuisance for nearby inhabitants. A simplified building model has been created for these situations, which includes the effects of soil-structure interaction, the low-frequency amplification along the height of the building as well as the high-frequency reduction and the floor resonances. The model consists of one wall for all supporting structures (walls and columns) and one floor for each storey. The effect of different floor resonance frequencies is included in a stochastic procedure. The soil is modelled by a spring and a viscous damper, and the free-field amplitudes of the soil are applied under this soil element.
The model can be calculated by transfer matrices or in a continuous wave-type version where an analytical solution can be evaluated numerically. The building response in the high-frequency (acoustic) region is calculated as mean values over wider frequency bands. The approach to an infinite building model can be found for these high frequencies and the corresponding soil-structure transfer can be described by the ratio of impedances at foundation level.
The rules for choosing the parameters to obtain realistic results are derived from complex calculations for example, for the stiffness and damping of building foundations and many measurements as for the damping of floor resonances. The influences on the floor resonance from the soil (damping) and the supporting structure (detuning) are important. Some more effects will be discussed by the simplified and detailed models and by measurements to establish a good understanding of ground-induced building vibrations.
The dynamics of slab tracks and floating slab tracks are analyzed by multibeam models for the track and by integration in the wave-number domain for the soil, which is modeled as a layered half-space. Frequency-dependent compliances and force transfers are calculated for a great variety of track and soil parameters. The distribution of the load and the displacements along the track is investigated as well as the wave propagation perpendicular to the track and the ground vibration amplitudes. The floating slab track has a dominating plate-mat resonance and a strong high-frequency reduction. A track-soil resonance can also be recognized for an unisolated slab track in the case of layered soils. Generally, there is a strong damping of the track by the soil. The reduction effect of the slab mat is mainly owing to the elimination of this strong damping. The continuous soil yields slightly different rules for the displacements and force densities than those of a Winkler support. The total force transfer from the rail to the soil is the best criterion to judge the effectiveness of a floating slab track in reducing the ground vibration at some distance from the railway line. The total force transfer is easier to calculate than the double Fourier integrals of the ground vibration amplitudes, namely in the far field, and it has the best correlation with the reduction of the ground vibration.
Vehicle, track and ground vibration as well as their interaction are considered in a combined finite-element boundary-element (FEBEM) approach. The layered soil is calculated in frequency wavenumber domain and the solution for fixed or moving point or track loads follow as wavenumber integrals. The soil results from the measurements and the detailed models are approximated by simple formula which are used for the prediction of train-induced ground vibration. The influence of the track and the soil on the train induced ground vibration is analysed by the detailed models. The ground vibrations strongly depend on the regular and random inhomogeneity of the soil. The regular layering of the soil yields a cut-on and resonance phenomenon while the random inhomogeneity yields a scattering of the axle impulses which proved to be important for high-speed trains. The attenuation with distance of the ground vibration due to the point-like excitations such as vibrator or hammer excitations and the train-track excitation are investigated and compared. All theoretical results are compared with measurements at conventional and high-speed railway lines.