Filtern
Erscheinungsjahr
- 2023 (14)
- 2022 (11)
- 2021 (9)
- 2020 (10)
- 2019 (12)
- 2018 (3)
- 2017 (15)
- 2016 (7)
- 2015 (9)
- 2014 (3)
- 2013 (5)
- 2012 (4)
- 2011 (4)
- 2010 (7)
- 2009 (4)
- 2008 (6)
- 2007 (6)
- 2006 (6)
- 2005 (8)
- 2004 (5)
- 2003 (1)
- 2002 (2)
- 2001 (1)
- 2000 (1)
- 1998 (1)
- 1997 (3)
- 1996 (1)
- 1995 (2)
- 1994 (1)
- 1991 (2)
- 1990 (1)
- 1989 (2)
- 1986 (3)
- 1984 (1)
Dokumenttyp
- Zeitschriftenartikel (52)
- Beitrag zu einem Tagungsband (47)
- Vortrag (46)
- Beitrag zu einem Sammelband (19)
- Posterpräsentation (4)
- Buchkapitel (1)
- Forschungsbericht (1)
Sprache
- Englisch (170) (entfernen)
Schlagworte
- Ground vibration (38)
- Layered soil (12)
- Slab track (11)
- Railway track (10)
- Mitigation (9)
- Track-soil interaction (9)
- Train passage (9)
- Vehicle-track interaction (9)
- Finite-element boundary-element method (8)
- Hammer impact (8)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (59)
- 7.2 Ingenieurbau (59)
Eingeladener Vortrag
- nein (46)
The maintenance of the transport infrastructures and their further development are going to remain focal points for investment and research in Germany in future. According to the latest development forecasts made by both the federal government and Deutsche Bahn, even if rail´s percentage share of the market were to remain unchanged, growth of around 50% would be expected in the next ten years, especially in freight traffic. This growth is necessitating considerable development both in the technical design of the tracks and in the abatement of the noise and vibration caused by railway traffic.
Ground vibrations created by running high-speed trains at speeds between 100 and 320 km/h are calculated in detail using transfer functions to model the effects of the moving loads. These transfer functions for layered soils are obtained by integration in the wavenumber domain. The train-induced vibrations in a soil that is considered to consist of single layers of two slightly different soils are analysed for different excitations: for their spectra, attenuation laws and amplitude-speed relations. An important mid-frequency component is shifted through the cut-on region of the layered soil with an increase in the train speed. The cut-on frequency divides the response of the layered soil into a low-frequency low-amplitude range and a high-frequency high-amplitude range. This leads to completely different train speed dependencies for the two soil layers with strongly increasing amplitudes around the cut-on frequency and almost constant amplitudes beyond this frequency. All calculated results closely agree with ground vibration measurements at two corresponding sites, especially if the mid-frequency component is calculated by axle impulses.
Vibration of normal apartment, office and production buildings, which are excited by technically induced ground vibrations are considered. Many wavelengths of the Rayleigh waves of the soil fit into the foundation dimensions. The related high discretization effort can nowadays be realized with detailed soil-structure interaction method. The combined finite-element boundary-element method is used here as a detatiled method. Simplified method can be used with less computation time, but these methods must be calibrated by exact results. One simplification is to extent the structure to infinity and to solve the problem by wavenumber domain methods. Another simplification is the use of a Winkler soil instead of the continuous soil. Usually, the Winkler parameters are not only soil parameters but depend also on the rigid or flexible foundation structure. Substructure methods use commercial FEM software for the building part. The contribution will show some detailed and some simplified results on large structural elements such as foundation plates, walls, storey plates on columns as well as results on complete buildings. The reduction of the ground vibration by stiff elements and the amplification due to floor or building resonances are discussed which are the most important phenomena of the soil-building interaction.
A variety of isolation measures exists to reduce the vibration in the neighbourhood of railway lines. They can be roughly classified as elastic or stiffening systems. There are the following elastic elements, rail pads or resilient fixation systems between rail and sleeper, under sleeper pads or sleeper shoes under the sleepers, and ballast mats under the ballast. Stiffening systems (plates) are used as slab tracks, floating slab tracks, or mass-spring systems. In the EU project “Railway induced vibration abatement solutions (RIVAS)”, elastic under sleeper pads have been investigated. The dynamic behaviour of the track and the surrounding soil has been calculated by the combined finite-element boundary-element method in a systematic parameter study. It has been shown that the mitigation effect can be improved by soft under sleeper pads or by heavy sleepers. Consequently, such track elements (soft under sleeper pads and heavy sleepers) have been thoroughly investigated in laboratory tests to establish the static and dynamic parameters as well as their serviceability. Finally, field tests at and near railway tracks with and without under sleeper pads have been performed. To determine the reduction effect of the isolated track, the ground vibrations excited by trains or artificial sources have been measured. The soil properties at the different sites have also been measured so that the comparison of the isolated and un-isolated track can take into account possible differences of the soil parameters. The contribution shows how the different (numerical, laboratory and field) methods and results can be combined to achieve an improved mitigation solution with soft under sleeper pads and heavy sleepers for ballasted and slab tracks.
A study on building vibrations has been performed by finite element calculations. Family houses, multi-storey residential buildings, office buildings and office towers have been modelled in detail. The frequency-dependent response due to a free-field excitation has been evaluated for walls, columns and floors. The ratio of building amplitudes to free-field amplitudes starts with uB/u0 = 1 at zero frequency and is usually lower than 1 at 50 Hz, the end of the frequency range considered here. In between, amplifications occur due to several reasons. There are „soil resonances“ where the whole building is vibrating on the compliant soil, “column resonances” where the upper storeys are vibrating on the compliant columns, and the “floor resonances” where the floors are vibrating excited by their supports. Results are presented for all building types, but a special focus is set on office buildings. A parameter study shows the influence of the stiffness of the soil, the number of storeys, and the width of the building. It has been found that the “soil resonance” is strongly modified by the low-frequency floor resonances for the normal office building. The main resonance of a twenty-storey office tower is determined equally by the “soil mode” and the “column mode”. It is an important observation for these office buildings that the resonances can differ for different parts of the building such as the centre, the edge, the corner, and the core of the building. This leads to non-uniform vibration modes across the building, which look like another type of “floor resonance” and which have been observed in several real building projects. Experimental results will be shown which can confirm the calculated phenomena.
A study on building vibrations has been performed by finite element calculations. Family houses, multi-storey residential buildings, office buildings and office towers have been modelled in detail. The frequency-dependent response due to a free-field excitation has been evaluated for walls, columns and floors. The ratio of building amplitudes to free-field amplitudes starts with uB/u0 = 1 at zero frequency and is usually lower than 1 at 50 Hz, the end of the frequency range considered here. In between, amplifications occur due to several reasons. There are „soil resonances“ where the whole building is vibrating on the compliant soil, “column resonances” where the upper storeys are vibrating on the compliant columns, and the “floor resonances” where the floors are vibrating excited by their supports. Results are presented for all building types, but a special focus is set on office buildings. A parameter study shows the influence of the stiffness of the soil, the number of storeys, and the width of the building. It has been found that the “soil resonance” is strongly modified by the low-frequency floor resonances for the normal office building. The main resonance of a twenty-storey office tower is determined equally by the “soil mode” and the “column mode”. It is an important observation for these office buildings that the resonances can differ for different parts of the building such as the centre, the edge, the corner, and the core of the building. This leads to non-uniform vibration modes across the building, which look like another type of “floor resonance” and which have been observed in several real building projects. Experimental results will be shown which can confirm the calculated phenomena.
A combined finite element boundary element method has been developed to calculate the dynamic interaction of the railway track and the underlying soil. The track-soil results are coupled with a simple vehicle model to establish the force transfer function of the vehicle-track-soil system. Mitigation measures at the track, namely three different tracks with under-sleeper pads, are analysed. The un-sprung vehicle and heavy track masses on soft track elements yield a lower vehicle-tracksoil resonant frequency and a better reduction of the excitation forces at higher frequencies. If the effectiveness of the mitigation is measured as a vibration ratio between the isolated and an un-isolated reference track, the vehicle-track-soil resonance of the reference track has an important influence on the mitigation effectiveness. Therefore, different un-isolated reference tracks are analysed. It is shown how the frequency and amplitude of the vehicle-track resonance are influenced by the stiffness of the rail pads (strongest), the ballast (medium) and the soil (weakest). The reference track models have been compared with shaker tests on two railway tracks with strong resonances. The damage detection and repair control have become important tasks for ballast and slab tracks. Measurements which compare the damaged and the repaired status of the same track section at different times, or which compare a damaged and an intact track section at the same time, have been successfully performed at some sites in Germany and compared with the theoretical behaviour of intact and damaged tracks.
A combined finite element boundary element method has been developed to calculate the dynamic interaction of the railway track and the underlying soil. The track-soil results are coupled with a simple vehicle model to establish the force transfer function of the vehicle-track-soil system. Mitigation measures at the track, namely three different tracks with under-sleeper pads, are analysed. The un-sprung vehicle and heavy track masses on soft track elements yield a lower vehicle-tracksoil resonant frequency and a better reduction of the excitation forces at higher frequencies. If the effectiveness of the mitigation is measured as a vibration ratio between the isolated and an un-isolated reference track, the vehicle-track-soil resonance of the reference track has an important influence on the mitigation effectiveness. Therefore, different un-isolated reference tracks are analysed. It is shown how the frequency and amplitude of the vehicle-track resonance are influenced by the stiffness of the rail pads (strongest), the ballast (medium) and the soil (weakest). The reference track models have been compared with shaker tests on two railway tracks with strong resonances. The damage detection and repair control have become important tasks for ballast and slab tracks. Measurements which compare the damaged and the repaired status of the same track section at different times, or which compare a damaged and an intact track section at the same time, have been successfully performed at some sites in Germany and compared with the theoretical behaviour of intact and damaged tracks.
Long wooden floor beams above a ball room in an old historical palace have been analysed experimentally. The eleven beams are weakly coupled by three layers of floor boards. It has been investigated if the state (the stiffness) of the wooden beams can be determined by vibration measurements of global or preferably local modes. Hammer, heel-drop and ambient excitations have been used. The vibration modes of the structure show dominating local deformations if an impact excitation is applied. This is understood as the positive superposition of several modes which yield the maximum at the excitation point but a cancellation at more distant points. Natural modes have been estimated from these vibration modes by standard and special methods which were necessary for the high damping of the wooden floor. It has been found that all floor beams contribute to each natural mode even for a weak coupling of the beams. In addition to the modal discussion, the impact tests have also been analysed for the wave propagation and amplitude attenuation with distance. The coupling of floor beams has been studied theoretically by an analytic multiple-beam model where the coupling by translational or rotational springs and by a common support motion has been assumed.
Long wooden floor beams above a ball room in an old historical palace have been analysed experimentally. The eleven beams are weakly coupled by three layers of floor boards. It has been investigated if the state (the stiffness) of the wooden beams can be determined by vibration measurements of global or preferably local modes. Hammer, heel-drop and ambient excitations have been used. The vibration modes of the structure show dominating local deformations if an impact excitation is applied. This is understood as the positive superposition of several modes which yield the maximum at the excitation point but a cancellation at more distant points. Natural modes have been estimated from these vibration modes by standard and special methods which were necessary for the high damping of the wooden floor. It has been found that all floor beams contribute to each natural mode even for a weak coupling of the beams. In addition to the modal discussion, the impact tests have also been analysed for the wave propagation and amplitude attenuation with distance. The coupling of floor beams has been studied theoretically by an analytic multiple-beam model where the coupling by translational or rotational springs and by a common support motion has been assumed.
The layered soil is calculated in the frequency wavenumber domain and the solutions for fixed or moving point or track loads follow as wavenumber integrals. The resulting point load solutions can be approximated by simple formula. Measurements yield the specific soil parameters for the theoretical or approximate solutions, but they can also directly provide the point-load solution (the transfer function of that site). A prediction method for the train-induced ground vibration has been developed, based on one of these site-specific transfer functions. The ground vibrations strongly depend on the regular and irregular inhomogeneity of the soil. The regular layering of the soil yields a cut-on and a resonance phenomenon, while the irregular inhomogeneity seems to be important for high-speed trains. The attenuations with the distance of the ground vibration, due to point-like excitations such as vibrator, hammer, or train-track excitations, were investigated and compared. All theoretical results were compared with measurements at conventional and high-speed railway lines, validating the approximate prediction method.
Construction work, such as pile driving and soil compaction, or road and railway traffic excite nearby buildings, and the perceptible or audible vibration can be a nuisance for nearby inhabitants. A simplified building model has been created for these situations, which includes the effects of soil-structure interaction, the low-frequency amplification along the height of the building as well as the high-frequency reduction and the floor resonances. The model consists of one wall for all supporting structures (walls and columns) and one floor for each storey. The effect of different floor resonance frequencies is included in a stochastic procedure. The soil is modelled by a spring and a viscous damper, and the free-field amplitudes of the soil are applied under this soil element.
The model can be calculated by transfer matrices or in a continuous wave-type version where an analytical solution can be evaluated numerically. The building response in the high-frequency (acoustic) region is calculated as mean values over wider frequency bands. The approach to an infinite building model can be found for these high frequencies and the corresponding soil-structure transfer can be described by the ratio of impedances at foundation level.
The rules for choosing the parameters to obtain realistic results are derived from complex calculations for example, for the stiffness and damping of building foundations and many measurements as for the damping of floor resonances. The influences on the floor resonance from the soil (damping) and the supporting structure (detuning) are important. Some more effects will be discussed by the simplified and detailed models and by measurements to establish a good understanding of ground-induced building vibrations.
The damage detection and repair control have become important tasks for ballast and slab tracks. Measurements which compare the damaged and the repaired status of the same track section at different times, or which compare a damaged and an intact track section at the same time, have been successfully performed at some sites in Germany with slab tracks and ballast tracks and compared with the theoretical behaviour of intact and damaged tracks. The loss of contact between the sleeper and the plate, between the plate and the base layer, and some problems with soft or weakened soil have been analysed. The observed results, changes in the time histories of displacements and velocities due to train passages and in the transfer functions (compliances) due to hammer impacts, are encouraging that these measurements can be used to detect track damage. In addition, calculations with the combined finite-element boundary-element method have been used to confirm the conclusions about intact or damaged railway tracks.
Some results of our measurements of the Intercity experimental are presented together with simulated results and their interpretation. Three frequeny ranges could be measured and calculated: low frequencies which decrease very rapidly with distance (the quasi-static part), high frequencies (mainly due to the sleeper passage), and a mid-frequency which has the weakest attenuation with distance and is therefore dominant at the far field. Mono-frequent excitations get a wide frequency band due to the Doppler effect of the moving high-speed train.
A survey of the phenomena and methods for floor vibrations is presented. Experimental results of floor vibrations are shown for many floors in six different buildings. The signals have been evaluated for waves and modes by simple procedures. General rules have been established between the material and the area of a specific floor, and its local eigenfrequency. The damping values of the floor vibrations have been found between D = 1 and 10 % where somewhat higher values have been measured for wooden floors, and a weak correlation with the eigenfrequency has been established. The velocities of bending waves propagating in a storey and the attenuation with distance in the building have been analysed. A considerable transfer of vibration from one room to far away parts of the building has been found in the studied buildings with concrete and wooden floors. An example building has been analysed for modes of coupled floor bays. The strong coupling of similar neighbouring floor bays would yield a wide band of global resonance frequencies. The measured wooden floor exhibits a weak coupling of the neighbouring floor bays and a narrower band of eigenfrequencies. A special method has been tested with the impulse measurements to estimate the coupled eigenmodes in presence of the high damping. From the ambient measurement, a low-frequency vibration mode has been detected which includes the vibration of the whole building and the soil. The coupling of floors to other floors and the whole building is an important phenomenon of structural dynamics which should be observed for the prediction of vibration due to internal and external sources.
Train-induced ground vibration can be excited by wheel and track irregularities and by two kinds of irregularities of the soil, by geometric irregularities or by the spatially varying soil stiffness. For both types of irregularities, the effective track irregularity on top of the track is calculated in wavenumber domain and with wavenumber integrals. For a general multi-beam track model, the wavenumber integrals are solved numerically. The irregularities of the soil are filtered by the track when transferred from the bottom to the top of the track. The high-wavenumber irregularities are strongly reduced due to the bending stiffness of the track and the compliance of the support. In addition, soft track elements reduce directly the stiffness variation of the support. Therefore, the mitigation effect of elastic track elements for these excitation components seems to be important. For under-sleeper pads and slab tracks, calculation and measurements are presented including additional excitation components and the dynamic vehicle–track interaction, and the relevance of the excitation mechanisms is discussed based on the dynamic forces which are acting on the ground. Due to the restricted amplitudes, the parametric excitation by the stiffness variation seems to be less important than the geometric irregularities. The calculations yield the correct trends of the measurements and many details of the measured ballast, slab, and under-sleeper-pad tracks.