Three measurement campaigns of train-induced ground vibrations are evaluated for the vehicle-track-soil interaction. Ground vibrations, track vibrations and vehicle vibrations have been measured for train passages and impulse excitation and compared with theoretical results. The soil and the track-soil system are calculated by wavenumber integrals. The influence of the vehicle is introduced by a substructure method. By comparing theory and measurement the different components of excitation force and ground vibration can be analysed, the quasi-static excitation, track-alignment errors, the out-of-roundness of wheels, the wheel and rail roughness, and moreover, scattered axle impulses and ineffective high-frequency parts of the wheelset accelerations and Forces.
Two measurement campaigns of train-induced ground vibrations are evaluated for the vehicle-track-soil interaction. Ground vibrations, track vibrations and vehicle vibrations have been measured for train passages and impulse excitation and compared with theoretical results. The soil and the track-soil system are calculated by wavenumber integrals. The influence of the vehicle is introduced by a substructure method. By comparing theory and measurement the different components of excitation force and ground vibration can be analysed, the quasi-static excitation, track-alignment errors, the out-of-roundness of wheels, the wheel and rail roughness, and moreover, scattered axle impulses and ineffective high-frequency parts of the wheelset accelerations and forces.
The present contribution evaluates four measuring series made by the Federal Institute of Material Research and Testing for the relations between train speed and ground vibration amplitudes. This experimental evaluation is supported by the simulation of the train passages at the different sites by using appropriate excitation mechanisms and forces as well as layered soil models which have been derived from impact measurements at each site.
Mitigation measures of railway induced vibration have been demonstrated at the emission, transmission and immission part. It must be carefully observed that the correct masses and stiffnesses are used.
Typical mistakes have been shown,
- 1D models for vehicle-track interaction,
- impedance instead of stiffness for the infill material of a trench,
- rigid buildings or neglecting the soil-building interaction.
The dominant mid-frequency part of the ground vibration is due to the irregular soil.
The passage of the train is dominated by the impulses of the static axle loads. The response of the regular homogeneous and irregular soils has been calculated by the finite-element method in frequency domain. The superposition of the impulse responses yields the quasi-static component of the ground vibration which is restricted to very low frequencies and to the close near-field of the track. In case of an irregular soil or ballast of which the stiffness varies randomly in space, a mid-frequency ground vibration component is generated by the scattering of the axle impulses. Measurements will be shown which prove the existence of the mid-frequency ground vibration component and the unique explanation by the scattered axle impulses: many international measurements with a raised mid-frequency component, axle-box measurements with a too low mid-frequency dynamic load, amplitude-speed dependencies which are incompatible with irregularity-induced dynamic loads, and ground vibration reductions due to stiff track elements.
A study on building vibrations has been performed by finite element calculations. Family houses, multi-storey residential buildings, office buildings and office towers have been modelled in detail. The frequency-dependent response due to a free-field excitation has been evaluated for walls, columns and floors. The ratio of building amplitudes to free-field amplitudes starts with uB/u0 = 1 at zero frequency and is usually lower than 1 at 50 Hz, the end of the frequency range considered here. In between, amplifications occur due to several reasons. There are „soil resonances“ where the whole building is vibrating on the compliant soil, “column resonances” where the upper storeys are vibrating on the compliant columns, and the “floor resonances” where the floors are vibrating excited by their supports. Results are presented for all building types, but a special focus is set on office buildings. A parameter study shows the influence of the stiffness of the soil, the number of storeys, and the width of the building. It has been found that the “soil resonance” is strongly modified by the low-frequency floor resonances for the normal office building. The main resonance of a twenty-storey office tower is determined equally by the “soil mode” and the “column mode”. It is an important observation for these office buildings that the resonances can differ for different parts of the building such as the centre, the edge, the corner, and the core of the building. This leads to non-uniform vibration modes across the building, which look like another type of “floor resonance” and which have been observed in several real building projects. Experimental results will be shown which can confirm the calculated phenomena.
Prediction of building noise and vibration – 3D finite element and 1D wave propagation models
(2021)
Construction work or traffic excite nearby buildings, and the perceptible or audible vibration can be a nuisance for the inhabitants. The transfer of the vibration from the free field to the building has been calculated by the finite element method for many models in consultancy and research work. The analysis for all storeys of certain building points such as walls, columns and floors unveiled some rules, some typical modes, and some wavetype responses. A simplified building-soil model has been created, which includes well these effects of building-soil resonance, wall/column resonance, floor resonances, and the high-frequency reduction. The model consists of one wall for a wall-type apartment building or a column for each specific part (mid, side or corner) of a column-type office building. The building response in the high-frequency (acoustic) region is calculated as mean values over all storeys and over wider frequency bands, by wave-type asymptotes of an infinitely tall building, and by the soil to wall ratio of impedances. The secondary noise is predicted by Transfer values between the building vibration (center of floors, walls at a room corner) and the sound pressure.
Measurements at the foundation, the surrounding soil and nearby buildings have been done during several drop tests of different containers on different foundations. The first measurements have been done on a big foundation where it should be guaranteed that the foundation is rigid and the container is tested properly. It was controlled that the foundation does not absorb more than 2 percent of the energy of the container. Most of the drop energy is lost in shock absorbers. Later on, a smaller drop test facility has been built on the ground but inside an existing building. It had to be controlled by prediction and measurements that the drop test will not damage the building. Tests from different heights on soft, medium, and stiff targets have been done to find out rules which allow to identify acceptable and unacceptable drop tests. Later on, the biggest drop test facility has been built for masses up to 200 t. It was necessary for the design of the foundation to estimate the forces which occur during the drop tests. On the other hand, the acceptable tests should be selected and controlled by measurements where the impact duration is important. Different sensors, accelerometers, accelerometers with mechanical filters, geophones (velocity transducers), strain gauges, and pressure cells have been applied for these tasks. The signals have been transformed to displacements which proved to be best suited for the interpretation of the impact mechanism. Modell calculations have been used to check and understand the dynamic measurements. The simplest law is the conservation of the momentum which is a good approximation if the impact is short. If the soil under the foundation has an influence on the deceleration of the container, the maximum foundation velocity is lower than the simple estimation. The amplitudes of the foundation could also be estimated from the ground vibrations and their amplitude-distance law.
Measured train passages and hammer impacts in combination with track-soil calculation have been successfully used for the detection of damaged slab tracks. This approach is now extended to intact slab and ballast tracks. The vibrations of many tracks have been measured at several levels from rail, sleeper, track plate, base plate, base layer to the subsoil by velocity or acceleration sensors. The time histories have to be integrated once or twice to get the displacements. The displacement signals include an arbitrary time-dependent shift which must be eliminated or respected in the interpretation. On the other hand, the calculation of slab and ballast tracks have been done in frequency-wavenumber domain. The displacements along the track and the frequency-dependent compliance transfer functions can be calculated. The latter can be compared with the results of the hammer impacts on the track. The deformation of the track can be transformed to time histories for a whole train and compared to the measured train passages. Many slab (and ballast) tracks have been measured at different sites. The displacements of the tracks are presented, and the following parameters have been analysed in the measurement results: slab track vs. ballast track, different types of slab tracks, damaged slab tracks, different trains, switches at different measuring points, an elastic layer, the mortar layer, different soils at different places. The soil should have the dominant influence on the track-plate displacements. Slab and ballast track yield also big differences in maximum displacement and width of deformation. Some of the preceding aspects will be analysed in comparison of measurement and theory.
Measurements of ground and track vibrations have been performed at a high-speed line in northern Germany. Impacts on the track and the ground, and passages of different trains with different speeds on different tracks have been measured. Transfer functions of the soil are presented and approximated by theoretical soil models. By using these transfer functions, the measured ground vibration between 2 to 64 m distance from the track can be transformed into a load spectrum which can be used for predictions at other sites. The method is compared to the soil-dependent method of an emission spectrum at a certain distance (8 m for example). The influence of train type, speed and track type is discussed on the base of the different emission quantities and the original measurements. The strong influence of the track, ballast track and slab track, is analysed by a theoretical model in wavenumber domain. The response of the track to the passage of the static load is reduced by the stiffness of the slab, the deformation of the track as well as the impulse acting on the soil. Usually, the impulse on the soil should result in a slow quasi-static movement of the soil, slower at further distances. In a heterogeneous soil, however, the impulses from the static loads scatter and keep parts of the higher impulse frequency band. In this case the reduced impulse spectra of the slab track will yield reduced ground vibration in a certain frequency band. Additional (BAM and international) measurements will be used to discuss this and possible other explanations for the different ground vibration differences.