The paper has been developed in the framework of a larger EC‐research program called NIKER, in which BAM and other seventeen research partners from the Mediterrean area are jointly involved. It aims to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets. The death tolls brought about by recent catastrophes in
developing countries where many inhabitants lived in earthen dwellings (Gujarat, India 2001, Bam, Iran 2003 and Concepción, Chile 2010 Earthquakes, Tamil Nadu 2004 Tsunami) have brought about research studies aimed at improving earth construction in terms of strength, seismic resistance and speed of construction.
In comparison to the recent advances in research on stone and brick masonry, knowledge on the material properties and failure mechanisms of earthen Building construction is limited and scattered.
The research presented here by aims making a comparison of mechanical behaviour between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob.
The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry Towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments in the Campania region were monitored by means of full-scale environmental vibration testing. Measured responses were then used for modal identification. The procedure is based on a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out by minimizing a weighted error criterion relative to the building’s modal properties. A satisfactory improvement on modal parameters is thus obtained, resulting in a close Agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is carried out with nonlinear static analysis of the tower under multimodal distributions of lateral loads.
Nonlinear analysis indicates the potential collapse mechanisms and evidences dangerous structural weakness which may play a role in the seismic vulnerability of the towers.
Structural performances of earthen building materials. A comparison between different typologies
(2011)
Traditional construction techniques utilizing earthen materials are often seen as inferior compared to modern ways of building. Structural earthen elements are perceived as vulnerable towards environmental influences (moisture, frost) and in particular towards the load scenarios during earthquakes. In comparison to the recent advances in research on stone and brick masonry, knowledge on the structural performance of earthen building construction is limited and scattered. Consequently the confidence in the performance of these earthen buildings constructed in the traditional techniques during earthquakes is fairly low. The research presented here aims to make a comparison of mechanical behavior between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob. The paper has been developed in the framework of a larger research program called NIKER. BAM and other seventeen research partners from the Mediterrean area are jointly involved to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets
Structural performances of earthen building materials. A comparison between different typologies
(2011)
The inelastic torsional response of an asymmetric-plan hospital building is studied. The response of the structure in the time domain as recorded by highly sensitive sensor network, integrated by a data acquisition system. The identification was performed using techniques of modal extraction in the frequency domain (frequency Domain decomposition). A calibration process was applied in order to identify a reliable structural model to be used for the seismic vulnerability assessment of the hospital building. In particular, a nonlinear static procedure accounting for mass distribution, higher modes contribution and mode-shapes correlation was proposed for the estimation of the seismic response of irregular buildings. Finally, the influence of lateral force distribution, node control during pushover and accidental eccentricity is investigated.