Filtern
Dokumenttyp
Sprache
- Englisch (4)
Schlagworte
- Cultural heritage (2)
- Earth masonry (2)
- Material test (2)
- Archaeology (1)
- Historical earthen building (1)
- Materials characterization (1)
- Mechanical behavior (1)
- Rammed earth (1)
- Seismic resistance (1)
- Static monitoring (1)
Structural performances of earthen building materials. A comparison between different typologies
(2011)
Traditional construction techniques utilizing earthen materials are often seen as inferior compared to modern ways of building. Structural earthen elements are perceived as vulnerable towards environmental influences (moisture, frost) and in particular towards the load scenarios during earthquakes. In comparison to the recent advances in research on stone and brick masonry, knowledge on the structural performance of earthen building construction is limited and scattered. Consequently the confidence in the performance of these earthen buildings constructed in the traditional techniques during earthquakes is fairly low. The research presented here aims to make a comparison of mechanical behavior between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob. The paper has been developed in the framework of a larger research program called NIKER. BAM and other seventeen research partners from the Mediterrean area are jointly involved to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets
The paper has been developed in the framework of a larger EC‐research program called NIKER, in which BAM and other seventeen research partners from the Mediterrean area are jointly involved. It aims to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets. The death tolls brought about by recent catastrophes in
developing countries where many inhabitants lived in earthen dwellings (Gujarat, India 2001, Bam, Iran 2003 and Concepción, Chile 2010 Earthquakes, Tamil Nadu 2004 Tsunami) have brought about research studies aimed at improving earth construction in terms of strength, seismic resistance and speed of construction.
In comparison to the recent advances in research on stone and brick masonry, knowledge on the material properties and failure mechanisms of earthen Building construction is limited and scattered.
The research presented here by aims making a comparison of mechanical behaviour between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob.
This study assesses the structural vulnerability of part of a later medieval earthen building at
Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military
Orders. An inspection of its morphology and materials coupled with the results of an extensive
campaign of static monitoring reveals marked structural inhomogeneities, the product of more
than a thousand years of construction, failure, and repair from the 10th century to the present
day. Building materials are inappropriately juxtaposed, there are discontinuities between construction
phases and fundamental concerns remain over the long-term stability of the structure.
The current condition of the structure is mainly influenced by structural discontinuities introduced
at the time of construction, the unintended consequences of repair and modification and the
material decay that has affected the base of the rammed earth walls. The overall findings of the
static monitoring show that there is no related damage, variations in crack widths are related to
the building seasonal cycle. While static analysis is an essential prerequisite before a suitable
maintenance program can be fully defined, this study argues that no evaluation of the structural
behavior of any historic building can afford to ignore its archaeological “biography” of modification
and repair.
This study presents diagnostic techniques to assess the structural vulnerability of earthen buildings. Medieval structures at Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military Orders, provide a useful case study. After more than a thousand years of construction, failure and repair from the 10th century to the present day, Ambel preceptory today is characterised by marked inhomogeneities: construction materials and structural typologies are juxtaposed, with structural discontinuities at the interfaces between construction phases. This paper argues that, while static analysis is an essential prerequisite before a suitable maintenance program can be defined, no evaluation of the structural behaviour of any historic building can ignore an understanding of the building’s history.