Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (36)
- Vortrag (30)
- Zeitschriftenartikel (15)
- Buchkapitel (9)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (57)
- Deutsch (34)
- Mehrsprachig (2)
- Italienisch (1)
Schlagworte
- Earthen materials (9)
- Rammed earth (8)
- Earth block masonry (7)
- Diagonal compression test (6)
- Baustoffe (5)
- Strengthening (5)
- Autoclaved aerated concrete (AAC) (4)
- Lehmbau (4)
- Shear behaviour (4)
- Ultra-high performance concrete (UHPC) (4)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (5)
- 7.1 Baustoffe (5)
Eingeladener Vortrag
- nein (30)
Ziel der Untersuchungen war es, das Verhalten von Verpressankern zu analysieren, die üblicherweise zur Verstärkung der Eckverbindung von Mauerwerkswänden eingesetzt werden. Im Fokus der Untersuchungen stand die Leistungsfähigkeit der Ankersysteme mit Bezug auf die Versagensarten und auf dem Traglastvermögen der Anker bei Ankerauszug durch gleichförmige Zugbelastung, die als Vereinfachung für die dynamische Belastung durch ein Erdbeben aufgebracht wurde. Die hier dargestellten Untersuchungen und Ergebnisse stellen eine Zusammenfassung von Arbeiten dar, über die bereits in Beiträgen berichtet wurde, die zum einen die Prüfverfahren für verstärkte Eckverbindungen von Gebäuden aus Mauerwerk und zum anderen die Verbundfestigkeit von Verpressankern in Wänden aus verschiedenen Lehmbautechniken zum Inhalt hatten. Sie geben dennoch einen Überblick über die Hauptversagensmechanismen von Verpressankersystemen und erweitern den Wissensstand bezüglich der Prüfung von Ankersystemen für Ziegel- und Lehmsteinmauerwerk. Darüber hinaus wird eine Vorgehensweise vorgeschlagen, die es ermöglicht, die Traglast von Verpressankern auf Basis experimenteller Untersuchungen abzuschätzen.
In this paper results of the experimental testing performed on brick masonry and earth block masonry are presented. The paper outlines the development of the testing procedures for two different types of anchors. For this purpose, two experimental campaigns of pull-out tests on masonry corner connections strengthened by metallic rod grouted were carried out. Experimental results proved that the implemented testing procedures are suitable to determine the most recurring failure modes of the anchor pins. Moreover, a procedure is proposed to estimate the capacity of grouted anchor pins based on experimental studies.
The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction.
The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction.
From the last decades the earth construction has a growing interest due to the high sustainability (low C02 emissions), thermal and acoustic performance, fire resistance and cost of the raw material (soil). In fact, earth construction can constitute a feasible solution for a more sustainable construction industry in developed countries. Nowadays the research areas on earthen construction focus from one side on the improvement of the materials for new buildings, on the other side on the Conservation of existing architectural heritage.
Historical earthen buildings are often damaged by static or dynamic loads in form of extensive cracking. All too often these cracks are insufficiently or inappropriately repaired, if at all, because of lack of knowledge and/or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage, etc. Cracks in earthen construction can be repaired by grouting to re-establish structural continuity, and can also be used to consolidate voids and gaps, or as a complement to other strengthening techniques such as the introduction of tie-rods.
In the framework of earthen materials for new constructions, the major drawback is that traditional earthen materials are typically considered as non-standard. The great variability and heterogeneity of the properties of the available soils, the lack of quality control in the manufacturing of the earthen materials and in the construction process can be pointed out as the main reasons behind this Situation. Furthermore, only few countries issued Standards and recommendations supporting earth construction, discouraging the design of earth construction by the technical community in countries where these documents are absent.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behavior of the single structural elements as well as to their mutual connections. Up to now only few data are available about the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate. In this paper, results of the experimental testing performed on earth block masonry, rammed earth and cob are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel rods with a lime based hydraulic grout and their compatibility with earthen materials. Rods with nuts were investigated to improve the pull-out capacity of the anchors. They showed higher pull-out capacity than rods without nuts. The performances of rods with nuts in cob were influenced by the rough surface at/of the earthen substrate. It is assumed that the non homogeneous surface caused an interlocking mechanism, which allowed to reach a pull-out capacity of about 54% higher than in earth block masonry.
The intensive use of earth as a building material since ancient times resulted in an important and significant earthen built heritage currently existing worldwide spread. The rammed earth technique has a significant presence in this heritage, where it served to build from simple dwell-ings to fortresses. However, the high vulnerability of rammed earth constructions to decay agents and to seismic events puts in risk their further existence and the lives of millions of peo-ple. With respect to the seismic behaviour of rammed earth walls, the understanding and mod-elling of their shear behaviour are topics underdeveloped in the bibliography. Nevertheless, these topics are of extreme importance in the preservation and strengthening of rammed earth constructions. Therefore, this paper presents a numerical work aiming at modelling the non-linear behaviour of unstabilised rammed earth under shear loading, resorting to the finite ele-ments method (FEM). The models were used to simulate the behaviour of a set of rammed earth wallets tested under diagonal compression. Both macro- and micro-modelling approach-es were considered, where the objective of this last approach was to evaluate the influence of apparent weakness of the interfaces between layers on the shear behaviour. The total strain ro-tating crack model (TSCRM) was used to simulate the behaviour of the rammed earth material, while the Mohr-Coulomb failure criterion was used to simulate the behaviour of interfaces be-tween layers. Furthermore, uncertainties related to the definition of the input parameters re-quired performing a sensitivity analysis. The numerical models achieved good agreement with the experimental results and the compressive strength, the Poisson’s ratio, the tensile strength and the tensile fracture energy revealed to be the most important parameters in the analyses.
The paper presents a comparison between two different numerical modelling approaches aimed to simulate the in-plain behaviour of rammed earth walls, namely under axial, diagonal and cyclic shearcompression loading. In the first part of the study the mechanical characterisation of wallets tested under uniaxial compression and diagonal compression and walls tested under in-plane cyclic shear-compression loading is presented. The results were used to implement and validate the finite element simulations.
The numerical modelling of the rammed earth samples tested is then discussed in the second part. A non-linear constitutive law based on the total strain rotating crack model (TSRCM) was employed as implemented in the DIANA® software. The aim of the numerical analyses presented here is to simulate the behaviour of rammed earth under different inplane loading conditions. For the wallets, tests under static loading both macro- and micro-modelling
approaches were considered for the simulation of the experimental tests. For the walls subjected to cyclic loading only the micro-modelling approach was applied for the simulation of the experimental tests.
The respective FEM model was calibrated with the experimental results. The rammed earth layers were represented by continuum elements, the contact surfaces between layers by interface elements. This approach allowed assessing the influence of the apparent weakness of the interfaces between layers on the shear behaviour of rammed earth.
The goal of the numerical simulation of the cyclic tests was to establish the adequacy of common analytical methods (e. g. used for masonry) applied to the analysis of rammed earth. Rammed earth exhibits brittle characteristics similar to masonry materials and is used in geometrical typologies, such as walls, common in masonry construction.
Die Instandsetzung von Lehmbauwerken ist keine einfache Aufgabe. Der Baustoff Lehm hat vergleichsweise schwache mechanische Eigenschaften. Er ist außerdem anfällig gegenüber eindringendem Wasser, wobei er sehr schnell seinen Zusammenhalt verlieren kann, wenn gewisse Feuchtegehalte überschritten werden. Instandsetzungskonzepte für Bauwerke aus solchen Materialien stellen deshalb eine Herausforderung dar. Historische Lehmbauwerke zeigen oft Schäden in Form von starker Rissbildung, die durch statische oder dynamische Lasten hervorgerufen sein kann. Häufig werden solche Risse wegen mangelnder Fachkenntnis und / oder fehlender Techniken nur ungenügend instandgesetzt. Die Rissinstandsetzung mit Einpressmörteln birgt insbesondere für Lehmbaustoffe eine Herausforderung und erfordert spezifische Anforderungen an den Einpressmörtel, wie z. B. niedriger Wassergehalt, gutes Wasserrückhaltevermögen, niedriges Schwindmaß, an das instandzusetzende Material angepasste Festigkeit und E-Modul sowie eine gute Haftung am Lehmuntergrund. Zusätzlich müssen Einpressmörtel eine ausreichende Fließfähigkeit aufweisen, um kleine Risse und Hohlräume ohne Entmischung zu füllen. Deshalb muss das rheologische Verhalten des Einpressmörtels gut untersucht und kontrolliert werden, um die gewünschte Wirkung zu erzielen. Die Rissinstandsetzung bei Lehmbauwerken erfolgt traditionell durch manuelles Stopfen mit einem Mörtel. Natürlich können auf diese Weise nur Risse mit einer großen Breite verfüllt werden. Ein weiterer Nachteil ist, dass Risse, die durch dickere Wände verlaufen, nicht vollständig mit den für das Stopfen verwendeten Werkzeugen erreicht werden können. Kalkgebundene Einpressmörtel für Lehmbaustoffe werden gewöhnlich für die Wiederbefestigung von Putzen und weniger aus statisch-konstruktiven Gründen eingesetzt.
Aufgrund der Eigenschaften von Lehm, müssen Einpressmörtel auf Basis von hydraulischem Kalk nach EN 459-1 [4] wesentliche Anforderungen an eine Reihe von Eigenschaften erfüllen, die sich auf die Verträglichkeit, die Dauerhaftigkeit und insbesondere die Injektionsfähigkeit beziehen. Das Ziel der vorgestellten Untersuchungen war einen Einpressmörtel zu herzustellen, mit dem die strukturelle Kontinuität in Lehmmauerwerk oder anderen massiven Lehmwänden (Stampf- und Wellerlehm) durch Rissverpressung wiederhergestellt werden kann. Das Material bestand aus Kalkhydrat mit Zusätzen von Puzzolanen und Kalksteinfüller.
In-plane shear behaviour of earthen materials panels strengthened with polyester fabric strips
(2016)
An experimental investigation was carried out to study the in-plane shear behaviour of earthen material Panels strengthened with polyester fabric strips. Strengthened panels were developed to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. Three earthen materials were considered: cob, earth block masonry (EBM) and rammed earth (RE). As first approach the strengthening configuration, based on different adhesive materials, was tested only for cob panels. As part of the study the results of a big testing campaign of unstrengthened Panels were considered. Seven strengthened panels were tested in diagonal compression/shear.A unique reinforcement orientation was used. The results of these tests are presented in this paper, and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective in EBM panels, with increase in strength and ductility observed. In RE and cob panels the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips. Instead, in EBM it was likely that the vertical reinforcement acted in tension to restrain shear induced dilation and to restrain sliding.
In-plane shear behaviour of earthen materials panels strengthened with polyester fabric strips
(2016)
An experimental investigation was carried out to study the in-plane shear behaviour of earthen material panels strengthened with polyester fabric strips. Strengthened panels were developed to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. Three earthen materials were considered: cob, earth block masonry (EBM) and rammed earth (RE). As first approach the strengthening configuration, based on different adhesive materials, was tested only for cob panels. As part of the study the results of a big testing campaign of unstrengthened Panels were considered. Seven strengthened panels were tested in diagonal compression/shear.A unique reinforcement orientation was used. The results of these tests are presented in this paper, and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective in EBM panels, with increase in strength and ductility observed. In RE and cob panels the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips. Instead, in EBM it was likely that the vertical reinforcement acted in tension to restrain shear induced dilation and to restrain sliding.
The main aim of the research was the development of a first valid database for material parameters of earth block masonry (EBM) with particular regard to statistical characteristics. A solid database is needed for the determination of the materials partial safety factor. Therefore, compressive strength tests were carried out with two types of earth blocks and two types of prefabricated earth mortar.
The evaluation has shown that the mean variation of the compressive strength was remarkably less than expected, which indicates high quality standards of the components earth block and mortar with regard to industrial production. Using the reliability method, a partial safety factor for EBM subjected to compression was determined on the basis of these test results. The findings have shown that a common calculation method for EBM based on partial safety factors following the valid masonry construction standard is feasible.
This paper presents an innovative way to combine an external ultra-high performance concrete (UHPC) supporting layer with an insulation layer of autoclaved aerated concrete (AAC) or cellular lightweight concrete (CLC) to create light-weight façade elements, which are improved in functionality and in energy efficiency. The durability of the façade elements is improved by developing UHPC with self-cleaning properties. One approach is based on the photocatalytic activation of the external UHPC shell by incorporation of TiO2 particles. The second approach consists of the modification of the UHPC surface by micro structuring in combination with the application of water-repellent agents to create durable super hydrophobicity. The current results obtained from laboratory testing are promising and demonstrate the feasibility of the approaches.
Der Beitrag präsentiert einen Vergleich zwischen verschiedenen numerischen Modellierungsansätzen die dazu dienen sollen, das flächige Verhalten von Stampflehmwänden, genauer unter axialer, diagonaler und zyklischer Scherkraftbelastung zu simulieren.
Im ersten Teil der Studie werden die mechanischen Eigenschaften der Wandscheiben, die unter einachsiger und diagonaler Druckbelastung getestet wurde und der Wände, die in flächigen, zyklischen Scherkraftbelastung getestet wurden, dargestellt. Die Ergebnisse werden verwendet, um die Finite Elemente Simulation anzuwenden und zu bewerten. Die numerische Modellierung der getesteten Stampflehmproben
wird dann im zweiten Teil diskutiert. Ein nichtlineares Materialgesetz basierend auf dem Gesamtdehnungsrissmodell (total strain rotating crack model – TSRCM) wurde, wie durch die Software DIANA® verwendet, angesetzt. Ziel dieser hier präsentierten numerischen Analyse ist es, das Verhalten von Stampflehm unter verschiedenen Lasteinflüssen
zu simulieren. Für die Wandscheiben wurden Versuche unter linearer Last, sowohl in Makro- als auch Mikromodellansätze für die Simulation der experimentellen Versuche gewählt. Für die Wände, welche zyklischer Belastung ausgesetzt waren, wurden nur die Mikromodellansätze für die Simulation der experimentellen Versuche gewählt. Das betreffende FEM Modell wurde mit den experimentellen Ergebnissen kalibriert. Die Stampflehmlagen wurden mit durchgehenden Elementen, die Kontaktflächen zwischen den Lagen mit Oberflächenelementen repräsentiert.
Dieser Ansatz erlaubte die Bewertung des Einflusses der auftretenden Schwächung in den Oberflächen zwischen den Lagen auf das Scherverhalten des Stampflehms. Ziel der numerischen Simulation von zyklischen Versuchen war es, die Eignung allgemeiner Analysemethoden (z. B. für Mauerwerk) für die Analyse von Stampflehm einzuführen und anzuwenden. Stampflehm zeigt brüchige Eigenschaften vergleichbar zu Mauerwerksbaustoffen und wird in geometrischen Formen, wie Wänden, genutzt, die im Mauerwerk üblich sind.
Die Instandsetzung von Lehmbauwerken ist keine einfache Aufgabe. Der Baustoff Lehm hat vergleichsweise schwache mechanische Eigenschaften. Er ist außerdem anfällig gegenüber eindringendem Wasser, wobei er sehr schnell seinen Zusammenhalt verlieren kann, wenn gewisse Feuchtegehalte überschritten werden. Instandsetzungskonzepte für Bauwerke aus solchen Materialien stellen deshalb eine Herausforderung dar. Historische Lehmbauwerke zeigen oft Schäden in Form von starker Rissbildung, die durch statische oder dynamische Lasten hervorgerufen sein kann. Häufig werden solche Risse wegen mangelnder Fachkenntnis und / oder fehlender Techniken nur ungenügend instandgesetzt. Die Rissinstandsetzung mit Einpressmörteln birgt insbesondere für Lehmbaustoffe eine Herausforderung und erfordert spezifische Anforderungen an den Einpressmörtel, wie z. B. niedriger Wassergehalt, gutes Wasserrückhaltevermögen, niedriges Schwindmaß, an das instandzusetzende Material angepasste Festigkeit und E-Modul sowie eine gute Haftung am Lehmuntergrund. Zusätzlich müssen Einpressmörtel eine ausreichende Fließfähigkeit aufweisen, um kleine Risse und Hohlräume ohne Entmischung zu füllen. Deshalb muss das rheologische Verhalten des Einpressmörtels gut untersucht und kontrolliert werden, um die gewünschte Wirkung zu erzielen.
Die Rissinstandsetzung bei Lehmbauwerken erfolgt traditionell durch manuelles Stopfen mit einem Mörtel. Natürlich können auf diese Weise nur Risse mit einer großen Breite verfüllt werden. Ein weiterer Nachteil ist, dass Risse, die durch dickere Wände verlaufen, nicht vollständig mit den für das Stopfen verwendeten Werkzeugen erreicht werden können. Kalkgebundene Einpressmörtel für Lehmbaustoffe werden gewöhnlich für die Wiederbefestigung von Putzen und weniger aus statisch-konstruktiven Gründen eingesetzt Aufgrund der Eigenschaften von Lehm, müssen Einpressmörtel auf Basis von hydraulischem Kalk nach EN 459-1 wesentliche Anforderungen an eine Reihe von Eigenschaften erfüllen, die sich auf die Verträglichkeit, die Dauerhaftigkeit und insbesondere die Injektionsfähigkeit beziehen. Das Ziel der vorgestellten Untersuchungen war einen Einpressmörtel zu herzustellen, mit dem die strukturelle Kontinuität in Lehmmauerwerk oder anderen massiven Lehmwänden (Stampf- und Wellerlehm) durch Rissverpressung wiederhergestellt werden kann. Das Material bestand aus Kalkhydrat mit Zusätzen von Puzzolanen und Kalksteinfüller.
The repair of earthen structures is not an easy task. Earth as a construction material has comparatively weak mechanical properties. It is also susceptible towards liquid water, were it can lose cohesion very quickly if certain moisture contents are exceeded. Repair concepts of structures built with such materials are therefore challenging. Historical earthen structures often exhibit damages in form of extensive cracking, which may have been caused by static or dynamic loads. Frequently these cracks are insufficiently or inappropriately repaired because of lack of knowledge and / or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage. Grouting materials require additional specifications such as compatible strengths and Young’s modulus as well as good adhesion to the earthen substrates. In addition, grouts have to be sufficiently flowable to fill small cracks and voids without segregation or bleeding. Therefore, the rheological behaviour has to be well understood and controlled to gain the desired effects.
The repair of cracks in earthen buildings is traditionally done by stuffing manually mortar into the gap. Naturally, this method is only usable for cracks with large widths. Another disadvantage is that cracks going through thicker walls cannot be completely reached by the tools used for stuffing the mortar into the crack. Lime based grouts for earthen materials were usually used for re-attachment of plasters but less for structural reasons. Due to the nature of earthen materials grouts based on formulated or hydraulic lime (according to the definition in EN 459-1) have to meet considerable demands on a variety of properties, which are related to compatibility, durability and in particular to the ability of being injected. The goal of this study was to create a grout, which can be used to re-establish structural continuity in cracked earthen masonry or other massive earth walls (rammed earth and cob) with the focus on grouting cracks. The grout material was based on hydrated lime (calcium hydroxide) with additions of pozzolana and lime stone filler.
Dynamic characterisation of historic bell-tower using a sensitivity-based technique for model tuning
(2018)
The most relevant results of the vibration-based investigations performed on a historic masonry tower in Italy namely the Santa Maria a Vico bell-tower is here presented. The first part of the study involves preliminary full-scale ambient vibration measurements in operational conditions and dynamics-based finite element (FE) modelling. At first, a manual tuning of the uncertain parameters of the model was carried out to adjust material properties, soil-structure interaction and constraining effect of the neighbouring structures. Then, based on the sensitivity analysis, only the most sensitive parameters were chosen as updating parameters. Finally, a model updating technique based on a sensitivity-based method was used to minimise the error between experimental vibration data and numerical response values. To this aim, a residual vector defined as the weighted difference between the measured quantities and calculated quantities was used. The uncertain structural parameters of the FE model were identified by minimising a robust penalty function. The calibrated model was used as an important tool for the seismic assessment of the structure using pushover analysis. Since the assumed value of the masonry compressive strength is the most sensitive parameter of non-linear behaviour, a sensitivity analysis was performed considering reference values in the range of interest. The seismic safety corresponding to increasing levels of the seismic hazard was finally investigated.
In the beginning of the 1980s earth building has undergone a renaissance, which nowadays leads to an increasing use of load-bearing earth constructions and in particular, earth block masonry. At present, there are no common structural standards according to the semi-probabilistic design concept, which is the state-of-the-art in European standards.
A solid database is needed for the determination of the partial safety factor on the resistance side. Therefore, compressive strength tests were carried out with two types of earth blocks and two types of prefabricated earth mortar. The evaluation showed that the variation of the compressive strength was remarkably less than expected, which seems to indicate high quality standards of the components earth block and mortar with regard to industrial production.
On the basis of these results and together with the reliability method, a partial safety factor for earth block masonry subjected to compression was determined. The main aim of the research was the development of a first valid database for material parameters of earth block masonry with particular regard to statistical characteristics. The results showed that a common calculation method for earth block masonry based on partial safety factors following the valid masonry construction standard is feasible.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behaviour of the single structural elements as well as by their mutual connections. Up to now limited data is available on the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate.
In this paper results of the experimental testing performed on earth block masonry are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel as well as glass fiber reinforced polymer (GFRP) rods with a lime based hydraulic grout and their compatibility with earth block masonry. GFRP rods were investigated as an alternative bonded-in anchorage material to the commonly used steel. In comparison with steel, they have a reduced weight and a reduced coefficient of thermal expansion. Their lower modulus of elasticity seems to be more compatible with the modulus of elasticity of earthen materials, although they exhibit a brittle fracture with lack of plastic phase.
In this paper an extensive research campaign aimed to define the mechanical performance of earth block masonry panels is presented. Uniaxial compression and diagonal compression tests were performed. The test results confirmed the brittle behaviour of earth block masonry under uniaxial compressive load and showed that the failure of earth block masonry under shear load occurs by sliding of the earth blocks along the mortar joints after initial cracking in mortar joints and earth blocks. For diagonal compression test results showed that building technique practice is one of the key factors affecting the structural performances. Experimental behaviour was modelled with a non-linear model capable of describing cracking behaviour. Both micro-modelling and macro-modelling implementing isotropic or orthotropic material laws were used to assess the reliability of different modelling strategies. The model calibration was carried out by sensibility analysis of the input parameters to understand the influence of unit strength on the shear behaviour of masonry.
China
(2017)
The contributions included in the book provide a reconnaissance on the conservation rules and current protection policies of more than 100 countries, with particular attention to the emerging nations and twentieth-century architecture. The contributions illustrate the critical issues related to architectural listings, with a brief history of national approaches, a linkography and a short bibliography. The book also provides a short critical lexicography, with 12 papers written by scholars and experts including topics on identities, heritages, conservation, memories and the economy. By examining the methods used to designate building as heritage sites across the continents, this book provides a com¬prehensive overview of current protection policies of twentieth-century architecture as well as the role of architectural history.
In this paper, a comparative study on the initial shear strength of
masonry with earth mortars is presented. Triplet tests were carried out to characterise the shear bond strength of five different types of earth mortar, three purely mineral and two with vegetable additives (wood and straw chaff), using calcium silicate blocks. In spite of their lower bulk densities, mortars with chaffs reached a value of compressive strength comparable to the values shown by the purely mineral mortars. The characteristic initial shear strengths of all the tested earth mortars were between two and five times higher than the minimum values for initial shear strengths required by standards.
To assess the influence of blocks pre-wetting, a comparison between calcium silicate blocks and earth blocks was performed to evaluate the results obtained from the standard test procedure compared to the more common practice of using earth mortars in combination with earthen blocks.
The aim of this study was to develop a lightweight composite façade element for refurbishment of existing façades. It was crucial to minimize the thermal bridges and to undercut the thermal requirement of the system existing façade new element. The awareness of the environmental impact of the building sector is increasing. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimized use of building area due to thinner elements and minimized maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibers. In this framework, composite elements have been developed combining an autoclaved aerated concrete insulation layer with an external UHPC supporting layer. The results show that the lightweight composite element has a good performance in term of thermal transmittance and minimization of thermal bridges.
This study analyses the mechanical behaviour under pseudo-dynamic loading of structural elements built in rammed earth and strengthened with polyester fabric strips. This strengthening technique was developed to exploit the strength potential of rammed earth and to solve its lack of tensile strength. For this reason, in-plane cyclic tests were carried out to investigate the shear behaviour of unstrengthened and strengthened walls. The strengthening technique requires low-tech equipment and workmanship, uses readily available, not expensive and industrially standardised materials. The experimental results were analysed in terms of stiffness degradation, energy dissipation capacity and equivalent viscous damping. Although the unstrengthened and strengthened walls confirmed a limited ductile behaviour, the findings confirm that the strengthening contributes to limit the spread of the diagonal cracks and provide an increase of strength in terms of horizontal load and displacement capacity.
The aim of this study was to develop a lightweight composite façade element for refurbishment of existing façades. It was crucial to minimize the thermal bridges and to undercut the thermal requirement of the system existing façade new element. The awareness of the environmental impact of the building sector is increasing. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimized use of building area due to thinner elements and minimized maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibers. In this framework, composite elements have been developed combining an autoclaved aerated concrete insulation layer with an external UHPC supporting layer. The results show that the lightweight composite element has a good performance in term of thermal transmittance and minimization of thermal bridges.
This study assesses the structural vulnerability of part of a later medieval earthen building at
Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military
Orders. An inspection of its morphology and materials coupled with the results of an extensive
campaign of static monitoring reveals marked structural inhomogeneities, the product of more
than a thousand years of construction, failure, and repair from the 10th century to the present
day. Building materials are inappropriately juxtaposed, there are discontinuities between construction
phases and fundamental concerns remain over the long-term stability of the structure.
The current condition of the structure is mainly influenced by structural discontinuities introduced
at the time of construction, the unintended consequences of repair and modification and the
material decay that has affected the base of the rammed earth walls. The overall findings of the
static monitoring show that there is no related damage, variations in crack widths are related to
the building seasonal cycle. While static analysis is an essential prerequisite before a suitable
maintenance program can be fully defined, this study argues that no evaluation of the structural
behavior of any historic building can afford to ignore its archaeological “biography” of modification
and repair.
Ziel der vorliegenden Untersuchung war es zu überprüfen, inwiefern eine Bemessungsvorschrift auf Basis von Teilsicherheitsbeiwerten im Lehmmauerwerksbau möglich ist. Bemessungsvorschriften im konventionellen Mauerwerksbau und im Lehmmauerwerksbau waren aufgrund des prinzipiell gleichen Tragverhaltens stets eng miteinander verknüpft. Die im Rahmen dieser Arbeit durchgeführten Druckversuche an Lehmmauermörtel, Lehmsteinen und Lehmmauerwerk konnten zeigen, dass die Streuungen der Festigkeiten von Lehmbaustoffen aufgrund der industriellen Herstellung sehr gering sind. Es konnte festgestellt werden, dass eine Bemessung auf Grundlage des semiprobabilistischen Bemessungskonzeptes in Anlehnung an den konventionellen Mauerwerksbau möglich ist. Neben einem ersten Vorschlag des Teilsicherheitsbeiwertes für den Lastzustand Druck werden Vorschläge für Prüfvorschriften im Lehmbau beziehungsweise deren Modifikation unterbreitet und künftige Forschungsschwerpunkte herausgearbeitet.
In diesem Beitrag werden numerische Analysen der mechanischen Eigenschaften von Lehmsteinmauerwerk unter Druck- und Schubbeanspruchung vorgestellt. Ergebnisse von einachsigen Druck- und Schubversuchen an Wandprüfkörpern lieferten dafür grundlegende mechanische Kennwerte im elastischen Bereich und im nichtelastischen Versagenszustand.Die Testergebnisse zeigten, dass verschiedene Vorlasten keinen wesentlichen Einfluss auf die Schubfestigkeit haben. Außerdem bestätigten die Ergebnisse das spröde Verhalten von Lehmsteinmauerwerk unter einachsiger Druckbelastung und es zeigte sich, dass das Versagen des Lehmsteinmauerwerks unter Scherbelastung entlang der Mörtelfugen erfolgt.
Die experimentellen Ergebnisse wurden verwendet, um das Verhalten von Lehmsteinmauerwerk durch nichtlineare Finite-Elemente-Methoden auf der Basis von Makro- und Mikro-Modellierungsansätzen zu simulieren. Entsprechendes konstitutives Materialverhalten und Zwängungen, die in den Versuchen durch die Art der Lasteinleitung in Form von Stahlprofilen und Stahlschuhen verursacht wurden, wurde in den Modellen berücksichtigt. Es wurde zuerst ein auf der Grundlage der experimentellen Daten kalibriertes Makro-Modell entwickelt, was zu einer brauchbaren Vorhersage des Versagensverhaltens der Mauerwerksprüfkörper führte. Die simulierten Spannungs-Dehnungs-Kurven, berechnet unter einachsiger Druckbelastung, zeigten eine gute Übereinstimmung mit den Ergebnissen der geprüften Mauerwerkskörper, sowohl im elastischen als auch im nichtelastischen Bereich. Ein vereinfachter Ansatz, basierend auf der Makro-Modellierung und einem homogenisierten Prüfkörper, kann für die Untersuchung größerer Tragsysteme oder ganzer Gebäude angewendet werden, wobei eine zufriedenstellende Genauigkeit bei geringerem Rechenaufwand erreicht wird. Obwohl das globale Spannungs-Dehnungs-Verhalten zufriedenstellend wiedergegeben wurde, ist ein solches nichtlineares isotropes Kontinuumsmodell für Lehmsteinmauerwerk nicht in vollem Umfang geeignet, um das bei den Versuchen beobachtete Rissbild an den Prüfkörpern zu simulieren.
Eine detailliertere Analyse des mechanischen Verhaltensdes Mauerwerks wurde mit einem Mikro-Modellierungsansatz durchgeführt. Das Modell, in dem ein Wandabschnitt nicht mehr homogenisiert, sondern in konkrete Stein- und Fugenelemente diskretisiert wird, hat sich insbesondere für das Verhalten von Lehmsteinmauerwerk unter Schubbeanspruchung als geeignet erwiesen. Die Auswertung der Spannungsverteilungen bei der nichtlinearen Analyse lieferte Informationen über die tatsächlichen Mechanismen der Lastübertragung zwischen Steinen und Mörtelfugen. Mit dem Mikro-Modell war es möglich, das nichtlineare Verhalten von Lehmsteinmauerwerk vorherzusagen. Es stellt somit ein geeignetes Werkzeug für die Untersuchung der Versagensmechanismen von Lehmsteinmauerwerk dar. Allerdings sind aufgrund der Komplexität des Modells für die Beschreibung der Stein/Mörtel-Schnittstelle und die hohe Anzahl an erforderlichen mechanischen Parametern umfassendere Untersuchungen notwendig. Die zukünftige Forschung wird sich daher einerseits auf die Verfeinerung der numerischen Modelle und andererseits auf die Simulation komplexer Belastungssituationen und Gebäudekomponenten konzentrieren.
The aim of this paper is to implement a numerical model to reproduce the nonlinear behavior of cob walls under shear loading.
Axial compression, pull-off, and diagonal compression tests were carried out to derive the mechanical parameters. In addition, the stressstrain relationships, the nonlinear behavior, and the failure modes were defined. The experimental results were then used to calibrate a finiteelement model. The material behavior was simulated through a macromodeling approach adopting the total strain rotating crack model.
A sensitivity analysis was conducted to assess the effects of varying the parameters with higher uncertainty on the structural behavior.
The numerical model achieved good correspondence with the experimental results in terms of simulation of the shear stress–shear strain relationship and of damage pattern.
The paper presents a comparison between different numerical modelling approaches aiming to simulate the in-plain behaviour of three types of earthen materials, namely adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical parameters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress–strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified Approach based on macromodelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to predict the adobe masonry and rammed earth collapse mechanisms.
The paper presents a comparison between different numerical modelling ap-proaches aiming to simulate the in-plain behaviour of three types of earthen materials, name-ly adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical param-eters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress–strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified approach based on macro-modelling shows a satisfactory accuracy and low computational costs. The results reproduc-ing the uniaxial compression are in good correspondence with the post-elastic behaviour ob-served in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to pre-dict the adobe masonry and rammed earth collapse mechanisms
An experimental investigation was carried out to study the in-plane shear behaviour of rammed earth structural elements strengthened with polyester fabric strips. The original idea for the retrofitting with polyester fabric strips was to introduce a vertical element for walls in order to take up horizontal loads resulting in a shear response of the building element. It has to be considered that vertical slits into the walls for fixing the strips are points of weakness and have to be mitigated by the adhesive. In this case a base coat mortar was employed. Strengthened elements were tested to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. As part of the study results of a testing campaign of unstrengthened structural elements were considered. Strengthened elements were tested in diagonal compression/shear and cyclic shear-compression. A unique reinforcement orientation was used. The results of these tests are presented in this paper and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective under cyclic shear-compression tests, with increase in load and displacement capacity observed. Under diagonal compression the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips.
An experimental investigation was carried out to study the in-plane shear behaviour of rammed earth structural elements strengthened with polyester fabric strips. The original idea for the retrofitting with polyester fabric strips was to introduce a vertical element for walls in order to take up horizontal loads resulting in a shear response of the building element. It has to be considered that vertical slits into the walls for fixing the strips are points of weakness and have to be mitigated by the adhesive. In this case a base coat mortar was employed. Strengthened elements were tested to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. As part of the study results of a testing campaign of unstrengthened structural elements were considered. Strengthened elements were tested in diagonal compression/shear and cyclic shear-compression. A unique reinforcement orientation was used. The results of these tests are presented in this paper and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective under cyclic shear-compression tests, with increase in load and displacement capacity observed. Under diagonal compression the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips.
The paper investigates the dynamic characterisation along with the numerical model tuning and the seismic risk assessment of a monumental masonry tower in Italy namely the Santa Maria a Vico bell tower. Full-scale ambient vibration tests were performed under the impact of environmental loads. The technique of modal extraction in the frequency domain was applied. In-situ investigation survey was used in calibrating the refined 3D finite element model. The FEM tuning was carried out by varying the mechanical parameters and accounting for the restraint offered by the neighbouring buildings and the role of soil–structure interaction. The paper shows that the modal identification is a reliable technique that can be used in-situ for assessing the dynamic behaviour of monumental buildings. The tuned FEM model of the tower was usefully employed to determine the theoretical fundamental frequencies, which accurately fit the experiment data. Finally, the seismic performance of the bell tower was assessed using a non-linear static procedure based on the multi-modal pushover analysis and the capacity spectrum method. The results confirm that seismic events of moderate intensity can produce heavy damage to the masonry tower presented in this study.
The paper investigates the dynamic characterisation along with the numerical model tuning and the seismic risk assessment of a monumental masonry tower in Italy namely the Santa Maria a Vico bell tower. Full-scale ambient vibration tests were performed under the impact of environmental loads. The technique of modal extraction in the frequency domain was applied. In-situ investigation survey was used in calibrating the refined 3D finite element model. The FEM tuning was carried out by varying the mechanical parameters and accounting for the restraint offered by the neighbouring buildings and the role of soil–structure interaction. The paper shows that the modal identification is a reliable technique that can be used in-situ for assessing the dynamic behaviour of monumental buildings. The tuned FEM model of the tower was usefully employed to determine the theoretical fundamental frequencies, which accurately fit the experiment data. Finally, the seismic performance of the bell tower was assessed using a non-linear static procedure based on the multi-modal pushover analysis and the capacity spectrum method. The results confirm that seismic events of moderate intensity can produce heavy damage to the masonry tower presented in this study.
The paper presents a comparison between different numerical modelling approaches aiming to simulate the in-plain behaviour of three types of earthen materials, namely adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical parameters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified Approach based on macromodelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to predict the adobe masonry and rammed earth collapse mechanisms.
Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany.