Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (36)
- Vortrag (30)
- Zeitschriftenartikel (15)
- Buchkapitel (9)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (57)
- Deutsch (34)
- Mehrsprachig (2)
- Italienisch (1)
Schlagworte
- Earthen materials (9)
- Rammed earth (8)
- Earth block masonry (7)
- Diagonal compression test (6)
- Baustoffe (5)
- Strengthening (5)
- Autoclaved aerated concrete (AAC) (4)
- Lehmbau (4)
- Shear behaviour (4)
- Ultra-high performance concrete (UHPC) (4)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (5)
- 7.1 Baustoffe (5)
Eingeladener Vortrag
- nein (30)
This study assesses the structural vulnerability of part of a later medieval earthen building at
Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military
Orders. An inspection of its morphology and materials coupled with the results of an extensive
campaign of static monitoring reveals marked structural inhomogeneities, the product of more
than a thousand years of construction, failure, and repair from the 10th century to the present
day. Building materials are inappropriately juxtaposed, there are discontinuities between construction
phases and fundamental concerns remain over the long-term stability of the structure.
The current condition of the structure is mainly influenced by structural discontinuities introduced
at the time of construction, the unintended consequences of repair and modification and the
material decay that has affected the base of the rammed earth walls. The overall findings of the
static monitoring show that there is no related damage, variations in crack widths are related to
the building seasonal cycle. While static analysis is an essential prerequisite before a suitable
maintenance program can be fully defined, this study argues that no evaluation of the structural
behavior of any historic building can afford to ignore its archaeological “biography” of modification
and repair.
The repair of earthen structures is not an easy task. Earth as a construction material has comparatively weak mechanical properties. It is also susceptible towards liquid water, were it can lose cohesion very quickly if certain moisture contents are exceeded. Repair concepts of structures built with such materials are therefore challenging. Historical earthen structures often exhibit damages in form of extensive cracking, which may have been caused by static or dynamic loads. Frequently these cracks are insufficiently or inappropriately repaired because of lack of knowledge and / or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage. Grouting materials require additional specifications such as compatible strengths and Young’s modulus as well as good adhesion to the earthen substrates. In addition, grouts have to be sufficiently flowable to fill small cracks and voids without segregation or bleeding. Therefore, the rheological behaviour has to be well understood and controlled to gain the desired effects.
The repair of cracks in earthen buildings is traditionally done by stuffing manually mortar into the gap. Naturally, this method is only usable for cracks with large widths. Another disadvantage is that cracks going through thicker walls cannot be completely reached by the tools used for stuffing the mortar into the crack. Lime based grouts for earthen materials were usually used for re-attachment of plasters but less for structural reasons. Due to the nature of earthen materials grouts based on formulated or hydraulic lime (according to the definition in EN 459-1) have to meet considerable demands on a variety of properties, which are related to compatibility, durability and in particular to the ability of being injected. The goal of this study was to create a grout, which can be used to re-establish structural continuity in cracked earthen masonry or other massive earth walls (rammed earth and cob) with the focus on grouting cracks. The grout material was based on hydrated lime (calcium hydroxide) with additions of pozzolana and lime stone filler.
Traditional earthen structures of cultural value are often damaged by static or dynamic loads. This is usually manifested by the appearance of cracks. All too often these cracks are insufficiently or inappropriately repaired if at all because of lack of knowledge and/or technology. In particular, the behavior of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage, etc. If dynamic loads, e.g. induced by earthquakes, are expected, the grouting material requires additional specifications such as a compatible strength and modulus of elasticity as well as good adhesion to the earthen materials. The study presents results from the development of a grouting material based on hydraulic lime mortar suitable for the repair of cracks in a variety of earthen building techniques. The goal was to develop a material also compatible with earthen structures exposed to dynamic load. The grouting mortar was designed to be adaptable in strength properties and at the same time to have sufficient robustness for the use on the construction site. First results show a satisfactory performance of the grout concerning fresh and hardened mortar properties as well as injectability. The study is part of our work in the framework of the ongoing project NIKER, funded by the European Commission dealing with improving imovable Cultural Heritage assets against the risk of earthquakes.
This study presents diagnostic techniques to assess the structural vulnerability of earthen buildings. Medieval structures at Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military Orders, provide a useful case study. After more than a thousand years of construction, failure and repair from the 10th century to the present day, Ambel preceptory today is characterised by marked inhomogeneities: construction materials and structural typologies are juxtaposed, with structural discontinuities at the interfaces between construction phases. This paper argues that, while static analysis is an essential prerequisite before a suitable maintenance program can be defined, no evaluation of the structural behaviour of any historic building can ignore an understanding of the building’s history.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behaviour of the single structural elements as well as by their mutual connections. Up to now limited data is available on the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate.
In this paper results of the experimental testing performed on earth block masonry are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel as well as glass fiber reinforced polymer (GFRP) rods with a lime based hydraulic grout and their compatibility with earth block masonry. GFRP rods were investigated as an alternative bonded-in anchorage material to the commonly used steel. In comparison with steel, they have a reduced weight and a reduced coefficient of thermal expansion. Their lower modulus of elasticity seems to be more compatible with the modulus of elasticity of earthen materials, although they exhibit a brittle fracture with lack of plastic phase.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behavior of the single structural elements as well as to their mutual connections. Up to now only few data are available about the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate. In this paper, results of the experimental testing performed on earth block masonry, rammed earth and cob are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel rods with a lime based hydraulic grout and their compatibility with earthen materials. Rods with nuts were investigated to improve the pull-out capacity of the anchors. They showed higher pull-out capacity than rods without nuts. The performances of rods with nuts in cob were influenced by the rough surface at/of the earthen substrate. It is assumed that the non homogeneous surface caused an interlocking mechanism, which allowed to reach a pull-out capacity of about 54% higher than in earth block masonry.
The goal of the present study is to assess the feasibility to develop a first reliable database of materials parameters for Earth Block Masonry (EBM). The database is crucial when defining the materials safety factors. In the first part an experimental campaign of compressive tests were carried out on two types of earth block and two types of earth mortar. The results showed that the mean variation of the compressive strength was remarkably less than expected. This low variation is related to a production with high quality standards of the materials employed. In the second part a partial safety factor for EBM under uniaxial compression was determined through the reliability method. The results proved the reliability of a common calculation method for EBM based on partial safety factors following the current standards.
The goal of the present study is to assess the feasibility to develop a first reliable database of materials parameters for Earth Block Masonry (EBM). The database is crucial when defining the materials safety factors. In the first part an experimental campaign of compressive tests were carried out on two types of earth block and two types of earth mortar. The results showed that the mean variation of the compressive strength was remarkably less than expected. This low variation is related to a production with high quality standards of the materials employed. In the second part a partial safety factor for EBM under uniaxial compression was determined through the reliability method. The results proved the reliability of a common calculation method for EBM based on partial safety factors following the current standards.
Characterisation of earthen elements. A comparison between earth block masonry, rammed earth and cob
(2012)
Das Wissen über die Materialeigenschaften und die Versagensmechanismen bei Lehmbaustoffen ist begrenzt und lückenhaft. Im Rahmen des EU-Projekts NIKER (www.niker.eu) wurden deshalb die mechanischen Eigenschaften von Bauteilen aus Lehm unter statischer Druck- und Schubbeanspruchung bestimmt. Ziel der Untersuchungen war es, grundlegende Daten zum Verformungs- und Versagensverhalten von Lehmbauteilen zu erhalten und dieses mit einem numerischen Modell zu beschreiben. Die Versuchsergebnisse belegten das spröde Verhalten von Lehmsteinmauerwerk bei uniaxialer Druckbelastung und zeigten, dass das Versagen von Lehmsteinmauerwerk infolge Schubbelastung nach Erstrissbildung in Mörtelfugen und Lehmsteinen durch Gleiten der Lehmsteine entlang der Mörtelfugen erfolgt. Die numerische Makromodellierung erbrachte zwar befriedigende Resultate hinsichtlich des Spannungs-Dehnungs-Verhaltens, jedoch konnte bei der simulierten Rissbildung keine Übereinstimmung mit den in den Versuchen beobachteten Rissbildern erzielt werden. Bei Lehmsteinmauerwerk ist also eine wesentlich aufwendigere Mikromodellierung notwendig, um das Versagensverhalten korrekt beschreiben zu können.--------------------------------------------------------------------------------------------------------------
Knowledge of the material properties and failure mechanisms of earthen materials is limited and scattered. Within the framework of the NIKER project (www.niker.eu) funded by EC, the mechanical properties of earthen material elements were therefore determined under static compression and shear loads. The aim was to obtain fundamental data on deformation behaviour and failure mechanisms of earthen material structural elements and to describe them by means of a numerical model. The test results confirmed the brittle behaviour of earth block masonry under monoaxial compressive load and showed that the failure of earth block masonry under shear load occurs by sliding of the earth blocks along the mortar joints after initial cracking in mortar joints and earth block. Numerical macro modelling showed satisfying results with regard to stress-strain behaviour, but the simulated crack pattern was not consistent with experimental observations. In the case of earth block masonry, it is thus necessary to use micro modelling approaches in order to correctly predict the failure process at local level.
Schätzungen zufolge leben und arbeiten zurzeit 30 bis 40 % der Weltbevölkerung in Gebäuden aus Lehm. Darunter befindet sich auch eine nicht unerhebliche Anzahl an Baudenkmälern, davon viele in einem gefährdeten Zustand. Bauwerke aus Lehm erfordern einen hohen Unterhaltungsaufwand, da sie anfällig sind für Erosion bei Regen sowie Abplatzungen und Querschnittsschwächung, wenn Salze kapillar transportiert werden und auskristallisieren. Außerdem sind sie empfindlich gegenüber mechanischen Beanspruchungen. So führen bereits relativ niedrige Zug- oder Druckspannungen zu Schädigungen durch Rissbildung. Einige Lehmbauweisen werden heute nicht mehr ausgeführt und das Wissen über sie ist zumindest teilweise verloren gegangen. Die verschiedenen Lehmbauweisen unterscheiden sich deutlich in Bezug auf die Zusammensetzung des Materials und die Bautechniken.
China
(2017)
The contributions included in the book provide a reconnaissance on the conservation rules and current protection policies of more than 100 countries, with particular attention to the emerging nations and twentieth-century architecture. The contributions illustrate the critical issues related to architectural listings, with a brief history of national approaches, a linkography and a short bibliography. The book also provides a short critical lexicography, with 12 papers written by scholars and experts including topics on identities, heritages, conservation, memories and the economy. By examining the methods used to designate building as heritage sites across the continents, this book provides a com¬prehensive overview of current protection policies of twentieth-century architecture as well as the role of architectural history.
Cina
(2013)
The paper has been developed in the framework of a larger EC‐research program called NIKER, in which BAM and other seventeen research partners from the Mediterrean area are jointly involved. It aims to develop and validate innovative materials and technologies for the systemic improvement of the seismic behavior of Cultural Heritage assets. The death tolls brought about by recent catastrophes in
developing countries where many inhabitants lived in earthen dwellings (Gujarat, India 2001, Bam, Iran 2003 and Concepción, Chile 2010 Earthquakes, Tamil Nadu 2004 Tsunami) have brought about research studies aimed at improving earth construction in terms of strength, seismic resistance and speed of construction.
In comparison to the recent advances in research on stone and brick masonry, knowledge on the material properties and failure mechanisms of earthen Building construction is limited and scattered.
The research presented here by aims making a comparison of mechanical behaviour between different earth masonry material typologies, consisting of earth block masonry, rammed earth and cob.
This paper presents an innovative way to combine an external ultra-high performance concrete (UHPC) supporting layer with an insulation layer of autoclaved aerated concrete (AAC) or cellular lightweight concrete (CLC) to create light-weight façade elements, which are improved in functionality and in energy efficiency. The durability of the façade elements is improved by developing UHPC with self-cleaning properties. One approach is based on the photocatalytic activation of the external UHPC shell by incorporation of TiO2 particles. The second approach consists of the modification of the UHPC surface by micro structuring in combination with the application of water-repellent agents to create durable super hydrophobicity. The current results obtained from laboratory testing are promising and demonstrate the feasibility of the approaches.
The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction.
The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction.
The aim of this study was to develop a lightweight composite façade element for refurbishment of existing façades. It was crucial to minimize the thermal bridges and to undercut the thermal requirement of the system existing façade new element. The awareness of the environmental impact of the building sector is increasing. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimized use of building area due to thinner elements and minimized maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibers. In this framework, composite elements have been developed combining an autoclaved aerated concrete insulation layer with an external UHPC supporting layer. The results show that the lightweight composite element has a good performance in term of thermal transmittance and minimization of thermal bridges.
The aim of this study was to develop a lightweight composite façade element for refurbishment of existing façades. It was crucial to minimize the thermal bridges and to undercut the thermal requirement of the system existing façade new element. The awareness of the environmental impact of the building sector is increasing. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimized use of building area due to thinner elements and minimized maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibers. In this framework, composite elements have been developed combining an autoclaved aerated concrete insulation layer with an external UHPC supporting layer. The results show that the lightweight composite element has a good performance in term of thermal transmittance and minimization of thermal bridges.
The study presents the results from the development of a grouting material based on hydrated lime with addition of pozzolana, which is referred to as hydraulic lime, suitable for the repair of cracks in a variety of earthen building techniques. The goal was to develop a material also compatible with earthen structures exposed to dynamic loads. The grouting mortar was designed to be adaptable in strength properties and at the same time to have sufficient robustness for preparation and use on the construction site.
Results showed a satisfactory performance of the grout concerning fresh and hardened mortar properties as well as injectability.
The main aim of the research was the development of a first valid database for material parameters of earth block masonry (EBM) with particular regard to statistical characteristics. A solid database is needed for the determination of the materials partial safety factor. Therefore, compressive strength tests were carried out with two types of earth blocks and two types of prefabricated earth mortar.
The evaluation has shown that the mean variation of the compressive strength was remarkably less than expected, which indicates high quality standards of the components earth block and mortar with regard to industrial production. Using the reliability method, a partial safety factor for EBM subjected to compression was determined on the basis of these test results. The findings have shown that a common calculation method for EBM based on partial safety factors following the valid masonry construction standard is feasible.
The paper investigates the dynamic characterisation, the numerical model tuning and the seismic risk assessment of two monumental masonry towers located in Italy: the Capua Cathedral bell tower and the Aversa Cathedral bell tower. Full-scale ambient vibration tests under environmental loads are performed. The modal identification is carried out using techniques of modal extraction in the frequency domain. The refined 3D finite element model (FEM) is calibrated using the in situ investigation survey. The FEM tuning is carried out by varying the mechanical parameters and accounting for the restraint offered by the neighbouring buildings and the role of soil–structure interaction. The assessment of the seismic performance of the bell towers is carried out through a nonlinear static procedure based on the multi-modal pushover analysis and the capacity spectrum method. Through the discussion of the case studies, the paper shows that the modal identification is a reliable technique that can be used in situ for assessing the dynamic behaviour of monumental buildings. By utilising the tuned FEM of the towers, the theoretical fundamental frequencies are determined, which coincide with the previously determined experimental frequencies. The results from seismic performance assessment through a pushover analysis confirm that the masonry towers in this study are particularly vulnerable to strong damage even when subjected to seismic events of moderate intensity.
Dynamic characterisation of historic bell-tower using a sensitivity-based technique for model tuning
(2018)
The most relevant results of the vibration-based investigations performed on a historic masonry tower in Italy namely the Santa Maria a Vico bell-tower is here presented. The first part of the study involves preliminary full-scale ambient vibration measurements in operational conditions and dynamics-based finite element (FE) modelling. At first, a manual tuning of the uncertain parameters of the model was carried out to adjust material properties, soil-structure interaction and constraining effect of the neighbouring structures. Then, based on the sensitivity analysis, only the most sensitive parameters were chosen as updating parameters. Finally, a model updating technique based on a sensitivity-based method was used to minimise the error between experimental vibration data and numerical response values. To this aim, a residual vector defined as the weighted difference between the measured quantities and calculated quantities was used. The uncertain structural parameters of the FE model were identified by minimising a robust penalty function. The calibrated model was used as an important tool for the seismic assessment of the structure using pushover analysis. Since the assumed value of the masonry compressive strength is the most sensitive parameter of non-linear behaviour, a sensitivity analysis was performed considering reference values in the range of interest. The seismic safety corresponding to increasing levels of the seismic hazard was finally investigated.
The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry Towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments in the Campania region were monitored by means of full-scale environmental vibration testing. Measured responses were then used for modal identification. The procedure is based on a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out by minimizing a weighted error criterion relative to the building’s modal properties. A satisfactory improvement on modal parameters is thus obtained, resulting in a close Agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is carried out with nonlinear static analysis of the tower under multimodal distributions of lateral loads.
Nonlinear analysis indicates the potential collapse mechanisms and evidences dangerous structural weakness which may play a role in the seismic vulnerability of the towers.
The recent experience of Italian seismic events provided wide observational information about typical behaviour, damage patterns and intrinsic vulnerability of monumental buildings. Evidence indicates that historical constructions are by far the most vulnerable from the seismic point of view. As a consequence, they demand for the definition of urgent strategies for the protection of cultural heritage from seismic hazard. The main goal of an in-depth knowledge of the structure should help to avoid inadequate, unsuitable or dangerous rehabilitation operations, as well as to select non-invasive and reversible techniques for the best exploitation of material and technology features. The definition of reliable models and methods for seismic risk assessment of historical constructions is today a very important topic. Typical problems of masonry structures concern aspects like inherent structural lacks, material degradation, geotechnical problems, buckling behaviour of slender elements and dynamic loading vulnerability. Modelling the mechanical behaviour of masonry may play an important role, due to both inherent material complexity and great scatter in mechanical properties. Effective procedures for the identification of the structural parameters from static and dynamic testing are thus required. In particular, dynamic measurements may be very useful for the identification of mechanical properties and soil restraints and, consequently, for the calibration of advanced numerical finite element models. The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments, placed in the Campania region, were monitored by means of full-scale environmental vibration testing. Measured responses are then used for modal identification with a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out on the basis of a criterion which minimises a weighted error on modal properties. A satisfactory improvement in the determination of modal parameters is thus obtained, resulting in a close agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is finally performed based on nonlinear static analysis of the tower under multimodal distributions of lateral loads. Results from nonlinear analysis indicate the potential collapse mechanisms and evidence dangerous structural weakness which may play a role in the seismic vulnerability of the towers.
Both in developed and developing countries, modern building materials tend to be preferred to traditional earthen construction. Reasons include low durability, inadequate performance under seismic loading and, in developing countries, a wish to replace what is perceived as 'poor' with what is perceived as 'rich'. In an age when building permissions and construction standards are a must, particularly in seismic areas, even when an owner is willing to build in earth, construction approval needs to be granted: we rely on values and standards to build, but the necessary data on material properties and structural performance of earthen building techniques is scarce if compared to the abundance of data for other materials (clay brick masonry, concrete, steel) available to the engineer. At the same time, traditional builders' skills, knowledge and confidence in earthen building techniques are decreasing if not disappearing. A wallette testing campaign was thus carried out with the aim of filling this knowledge gap. Prior to the wallette campaign, material properties, including composition and physical-mechanical parameters, were determined. Compression and diagonal compression (shear) tests were then performed, and a basic analysis of the mechanical behaviour of structural elements built in cob is provided in relation to earth block (adobe) masonry and rammed earth elements. Cob, shown to have low compressive resistance, has a relatively ductile post-peak behaviour if compared to earth block masonry specimens which, as expected, show a marked brittle behaviour. In terms of shear strength, cob performs relatively well in view of its low compressive strength. The study is part of our work within the framework of the ongoing project NIKER funded by the European Commission dealing with improving the structural performance of Cultural Heritage assets in order to limit earthquake hazards.
From the last decades the earth construction has a growing interest due to the high sustainability (low C02 emissions), thermal and acoustic performance, fire resistance and cost of the raw material (soil). In fact, earth construction can constitute a feasible solution for a more sustainable construction industry in developed countries. Nowadays the research areas on earthen construction focus from one side on the improvement of the materials for new buildings, on the other side on the Conservation of existing architectural heritage.
Historical earthen buildings are often damaged by static or dynamic loads in form of extensive cracking. All too often these cracks are insufficiently or inappropriately repaired, if at all, because of lack of knowledge and/or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage, etc. Cracks in earthen construction can be repaired by grouting to re-establish structural continuity, and can also be used to consolidate voids and gaps, or as a complement to other strengthening techniques such as the introduction of tie-rods.
In the framework of earthen materials for new constructions, the major drawback is that traditional earthen materials are typically considered as non-standard. The great variability and heterogeneity of the properties of the available soils, the lack of quality control in the manufacturing of the earthen materials and in the construction process can be pointed out as the main reasons behind this Situation. Furthermore, only few countries issued Standards and recommendations supporting earth construction, discouraging the design of earth construction by the technical community in countries where these documents are absent.
Die Instandsetzung von Lehmbauwerken ist keine einfache Aufgabe. Der Baustoff Lehm hat vergleichsweise schwache mechanische Eigenschaften. Er ist außerdem anfällig gegenüber eindringendem Wasser, wobei er sehr schnell seinen Zusammenhalt verlieren kann, wenn gewisse Feuchtegehalte überschritten werden. Instandsetzungskonzepte für Bauwerke aus solchen Materialien stellen deshalb eine Herausforderung dar. Historische Lehmbauwerke zeigen oft Schäden in Form von starker Rissbildung, die durch statische oder dynamische Lasten hervorgerufen sein kann. Häufig werden solche Risse wegen mangelnder Fachkenntnis und / oder fehlender Techniken nur ungenügend instandgesetzt. Die Rissinstandsetzung mit Einpressmörteln birgt insbesondere für Lehmbaustoffe eine Herausforderung und erfordert spezifische Anforderungen an den Einpressmörtel, wie z. B. niedriger Wassergehalt, gutes Wasserrückhaltevermögen, niedriges Schwindmaß, an das instandzusetzende Material angepasste Festigkeit und E-Modul sowie eine gute Haftung am Lehmuntergrund. Zusätzlich müssen Einpressmörtel eine ausreichende Fließfähigkeit aufweisen, um kleine Risse und Hohlräume ohne Entmischung zu füllen. Deshalb muss das rheologische Verhalten des Einpressmörtels gut untersucht und kontrolliert werden, um die gewünschte Wirkung zu erzielen. Die Rissinstandsetzung bei Lehmbauwerken erfolgt traditionell durch manuelles Stopfen mit einem Mörtel. Natürlich können auf diese Weise nur Risse mit einer großen Breite verfüllt werden. Ein weiterer Nachteil ist, dass Risse, die durch dickere Wände verlaufen, nicht vollständig mit den für das Stopfen verwendeten Werkzeugen erreicht werden können. Kalkgebundene Einpressmörtel für Lehmbaustoffe werden gewöhnlich für die Wiederbefestigung von Putzen und weniger aus statisch-konstruktiven Gründen eingesetzt.
Aufgrund der Eigenschaften von Lehm, müssen Einpressmörtel auf Basis von hydraulischem Kalk nach EN 459-1 [4] wesentliche Anforderungen an eine Reihe von Eigenschaften erfüllen, die sich auf die Verträglichkeit, die Dauerhaftigkeit und insbesondere die Injektionsfähigkeit beziehen. Das Ziel der vorgestellten Untersuchungen war einen Einpressmörtel zu herzustellen, mit dem die strukturelle Kontinuität in Lehmmauerwerk oder anderen massiven Lehmwänden (Stampf- und Wellerlehm) durch Rissverpressung wiederhergestellt werden kann. Das Material bestand aus Kalkhydrat mit Zusätzen von Puzzolanen und Kalksteinfüller.
Die Instandsetzung von Lehmbauwerken ist keine einfache Aufgabe. Der Baustoff Lehm hat vergleichsweise schwache mechanische Eigenschaften. Er ist außerdem anfällig gegenüber eindringendem Wasser, wobei er sehr schnell seinen Zusammenhalt verlieren kann, wenn gewisse Feuchtegehalte überschritten werden. Instandsetzungskonzepte für Bauwerke aus solchen Materialien stellen deshalb eine Herausforderung dar. Historische Lehmbauwerke zeigen oft Schäden in Form von starker Rissbildung, die durch statische oder dynamische Lasten hervorgerufen sein kann. Häufig werden solche Risse wegen mangelnder Fachkenntnis und / oder fehlender Techniken nur ungenügend instandgesetzt. Die Rissinstandsetzung mit Einpressmörteln birgt insbesondere für Lehmbaustoffe eine Herausforderung und erfordert spezifische Anforderungen an den Einpressmörtel, wie z. B. niedriger Wassergehalt, gutes Wasserrückhaltevermögen, niedriges Schwindmaß, an das instandzusetzende Material angepasste Festigkeit und E-Modul sowie eine gute Haftung am Lehmuntergrund. Zusätzlich müssen Einpressmörtel eine ausreichende Fließfähigkeit aufweisen, um kleine Risse und Hohlräume ohne Entmischung zu füllen. Deshalb muss das rheologische Verhalten des Einpressmörtels gut untersucht und kontrolliert werden, um die gewünschte Wirkung zu erzielen.
Die Rissinstandsetzung bei Lehmbauwerken erfolgt traditionell durch manuelles Stopfen mit einem Mörtel. Natürlich können auf diese Weise nur Risse mit einer großen Breite verfüllt werden. Ein weiterer Nachteil ist, dass Risse, die durch dickere Wände verlaufen, nicht vollständig mit den für das Stopfen verwendeten Werkzeugen erreicht werden können. Kalkgebundene Einpressmörtel für Lehmbaustoffe werden gewöhnlich für die Wiederbefestigung von Putzen und weniger aus statisch-konstruktiven Gründen eingesetzt Aufgrund der Eigenschaften von Lehm, müssen Einpressmörtel auf Basis von hydraulischem Kalk nach EN 459-1 wesentliche Anforderungen an eine Reihe von Eigenschaften erfüllen, die sich auf die Verträglichkeit, die Dauerhaftigkeit und insbesondere die Injektionsfähigkeit beziehen. Das Ziel der vorgestellten Untersuchungen war einen Einpressmörtel zu herzustellen, mit dem die strukturelle Kontinuität in Lehmmauerwerk oder anderen massiven Lehmwänden (Stampf- und Wellerlehm) durch Rissverpressung wiederhergestellt werden kann. Das Material bestand aus Kalkhydrat mit Zusätzen von Puzzolanen und Kalksteinfüller.
In this paper, a comparative study on the initial shear strength of
masonry with earth mortars is presented. Triplet tests were carried out to characterise the shear bond strength of five different types of earth mortar, three purely mineral and two with vegetable additives (wood and straw chaff), using calcium silicate blocks. In spite of their lower bulk densities, mortars with chaffs reached a value of compressive strength comparable to the values shown by the purely mineral mortars. The characteristic initial shear strengths of all the tested earth mortars were between two and five times higher than the minimum values for initial shear strengths required by standards.
To assess the influence of blocks pre-wetting, a comparison between calcium silicate blocks and earth blocks was performed to evaluate the results obtained from the standard test procedure compared to the more common practice of using earth mortars in combination with earthen blocks.
The current paper focuses on the determination of reliable numerical models of earth block masonry wallettes under different loading conditions. Uniaxial compression and diagonal compression tests were performed. Experimental behaviour was modelled with a non-linear model able to describe the cracking behaviour. The simplified approach based on macro-modelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with high computational cost, represents a suitable tool to predict the masonry collapse mechanism.
The paper presents a comparison between different numerical modelling approaches aiming to simulate the in-plain behaviour of three types of earthen materials, namely adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical parameters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress–strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified Approach based on macromodelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to predict the adobe masonry and rammed earth collapse mechanisms.
The paper presents a comparison between different numerical modelling ap-proaches aiming to simulate the in-plain behaviour of three types of earthen materials, name-ly adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical param-eters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress–strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified approach based on macro-modelling shows a satisfactory accuracy and low computational costs. The results reproduc-ing the uniaxial compression are in good correspondence with the post-elastic behaviour ob-served in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to pre-dict the adobe masonry and rammed earth collapse mechanisms
The paper presents a comparison between different numerical modelling approaches aiming to simulate the in-plain behaviour of three types of earthen materials, namely adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical parameters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified Approach based on macromodelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to predict the adobe masonry and rammed earth collapse mechanisms.
The purpose of this paper is to numerically simulate the in-plane behaviour of rammed earth walls under cyclic shear-compression tests. The experimental testing allowed obtaining the maximum horizontal loads, the displacement capacity and the level of non-linear behaviour of the respective loaddisplacement relationships as well as the failure modes. The calibration of the numerical model (finite element method) was carried out based on the experimental results. Within this framework, a micromodelling approach was considered. The behaviour of the rammed earth material was simulated using a total strain rotating crack model. A Mohr-Coulomb failure criterion was used to reproduce the behaviour of the interfaces between the layers.
Although the numerical results achieved a satisfactory agreement with the experimental results a sensitivity analysis of the parameters involved was performed. The sensitivity analysis aimed at determining which parameters of the model have a significant impact in the model’s results. As expected the sensitivity analysis pointed out that the sliding failure occurrence is mainly influenced by two parameters of the interface elements: the interface tensile strength fit and the friction angle u. Moreover the cohesion c and the layers thickness showed a limited effect on the shear behaviour. It should be noted that the results mentioned above are related to the cases where a significant level of vertical compressive stress r is employed.