Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (36)
- Vortrag (30)
- Zeitschriftenartikel (15)
- Buchkapitel (9)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (57)
- Deutsch (34)
- Mehrsprachig (2)
- Italienisch (1)
Schlagworte
- Earthen materials (9)
- Rammed earth (8)
- Earth block masonry (7)
- Diagonal compression test (6)
- Baustoffe (5)
- Strengthening (5)
- Autoclaved aerated concrete (AAC) (4)
- Lehmbau (4)
- Shear behaviour (4)
- Ultra-high performance concrete (UHPC) (4)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (5)
- 7.1 Baustoffe (5)
Eingeladener Vortrag
- nein (30)
The inelastic torsional response of an asymmetric-plan hospital building is studied. The response of the structure in the time domain as recorded by highly sensitive sensor network, integrated by a data acquisition system. The identification was performed using techniques of modal extraction in the frequency domain (frequency Domain decomposition). A calibration process was applied in order to identify a reliable structural model to be used for the seismic vulnerability assessment of the hospital building. In particular, a nonlinear static procedure accounting for mass distribution, higher modes contribution and mode-shapes correlation was proposed for the estimation of the seismic response of irregular buildings. Finally, the influence of lateral force distribution, node control during pushover and accidental eccentricity is investigated.
The recent experience of Italian seismic events provided wide observational information about typical behaviour, damage patterns and intrinsic vulnerability of monumental buildings. Evidence indicates that historical constructions are by far the most vulnerable from the seismic point of view. As a consequence, they demand for the definition of urgent strategies for the protection of cultural heritage from seismic hazard. The main goal of an in-depth knowledge of the structure should help to avoid inadequate, unsuitable or dangerous rehabilitation operations, as well as to select non-invasive and reversible techniques for the best exploitation of material and technology features. The definition of reliable models and methods for seismic risk assessment of historical constructions is today a very important topic. Typical problems of masonry structures concern aspects like inherent structural lacks, material degradation, geotechnical problems, buckling behaviour of slender elements and dynamic loading vulnerability. Modelling the mechanical behaviour of masonry may play an important role, due to both inherent material complexity and great scatter in mechanical properties. Effective procedures for the identification of the structural parameters from static and dynamic testing are thus required. In particular, dynamic measurements may be very useful for the identification of mechanical properties and soil restraints and, consequently, for the calibration of advanced numerical finite element models. The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments, placed in the Campania region, were monitored by means of full-scale environmental vibration testing. Measured responses are then used for modal identification with a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out on the basis of a criterion which minimises a weighted error on modal properties. A satisfactory improvement in the determination of modal parameters is thus obtained, resulting in a close agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is finally performed based on nonlinear static analysis of the tower under multimodal distributions of lateral loads. Results from nonlinear analysis indicate the potential collapse mechanisms and evidence dangerous structural weakness which may play a role in the seismic vulnerability of the towers.
The paper addresses two case studies of structural monitoring and seismic assessment of medieval masonry Towers in Italy: the bell tower of Aversa and the bell tower of Capua. These monuments in the Campania region were monitored by means of full-scale environmental vibration testing. Measured responses were then used for modal identification. The procedure is based on a typical finite element model updating technique based on vibration test results. Parameters optimization is carried out by minimizing a weighted error criterion relative to the building’s modal properties. A satisfactory improvement on modal parameters is thus obtained, resulting in a close Agreement between the modal properties observed in dynamic tests and those calculated from numerical model. Seismic assessment is carried out with nonlinear static analysis of the tower under multimodal distributions of lateral loads.
Nonlinear analysis indicates the potential collapse mechanisms and evidences dangerous structural weakness which may play a role in the seismic vulnerability of the towers.
Dynamic characterisation of historic bell-tower using a sensitivity-based technique for model tuning
(2018)
The most relevant results of the vibration-based investigations performed on a historic masonry tower in Italy namely the Santa Maria a Vico bell-tower is here presented. The first part of the study involves preliminary full-scale ambient vibration measurements in operational conditions and dynamics-based finite element (FE) modelling. At first, a manual tuning of the uncertain parameters of the model was carried out to adjust material properties, soil-structure interaction and constraining effect of the neighbouring structures. Then, based on the sensitivity analysis, only the most sensitive parameters were chosen as updating parameters. Finally, a model updating technique based on a sensitivity-based method was used to minimise the error between experimental vibration data and numerical response values. To this aim, a residual vector defined as the weighted difference between the measured quantities and calculated quantities was used. The uncertain structural parameters of the FE model were identified by minimising a robust penalty function. The calibrated model was used as an important tool for the seismic assessment of the structure using pushover analysis. Since the assumed value of the masonry compressive strength is the most sensitive parameter of non-linear behaviour, a sensitivity analysis was performed considering reference values in the range of interest. The seismic safety corresponding to increasing levels of the seismic hazard was finally investigated.
The paper investigates the dynamic characterisation along with the numerical model tuning and the seismic risk assessment of a monumental masonry tower in Italy namely the Santa Maria a Vico bell tower. Full-scale ambient vibration tests were performed under the impact of environmental loads. The technique of modal extraction in the frequency domain was applied. In-situ investigation survey was used in calibrating the refined 3D finite element model. The FEM tuning was carried out by varying the mechanical parameters and accounting for the restraint offered by the neighbouring buildings and the role of soil–structure interaction. The paper shows that the modal identification is a reliable technique that can be used in-situ for assessing the dynamic behaviour of monumental buildings. The tuned FEM model of the tower was usefully employed to determine the theoretical fundamental frequencies, which accurately fit the experiment data. Finally, the seismic performance of the bell tower was assessed using a non-linear static procedure based on the multi-modal pushover analysis and the capacity spectrum method. The results confirm that seismic events of moderate intensity can produce heavy damage to the masonry tower presented in this study.
The paper investigates the dynamic characterisation, the numerical model tuning and the seismic risk assessment of two monumental masonry towers located in Italy: the Capua Cathedral bell tower and the Aversa Cathedral bell tower. Full-scale ambient vibration tests under environmental loads are performed. The modal identification is carried out using techniques of modal extraction in the frequency domain. The refined 3D finite element model (FEM) is calibrated using the in situ investigation survey. The FEM tuning is carried out by varying the mechanical parameters and accounting for the restraint offered by the neighbouring buildings and the role of soil–structure interaction. The assessment of the seismic performance of the bell towers is carried out through a nonlinear static procedure based on the multi-modal pushover analysis and the capacity spectrum method. Through the discussion of the case studies, the paper shows that the modal identification is a reliable technique that can be used in situ for assessing the dynamic behaviour of monumental buildings. By utilising the tuned FEM of the towers, the theoretical fundamental frequencies are determined, which coincide with the previously determined experimental frequencies. The results from seismic performance assessment through a pushover analysis confirm that the masonry towers in this study are particularly vulnerable to strong damage even when subjected to seismic events of moderate intensity.
In this paper, a comparative study on the initial shear strength of
masonry with earth mortars is presented. Triplet tests were carried out to characterise the shear bond strength of five different types of earth mortar, three purely mineral and two with vegetable additives (wood and straw chaff), using calcium silicate blocks. In spite of their lower bulk densities, mortars with chaffs reached a value of compressive strength comparable to the values shown by the purely mineral mortars. The characteristic initial shear strengths of all the tested earth mortars were between two and five times higher than the minimum values for initial shear strengths required by standards.
To assess the influence of blocks pre-wetting, a comparison between calcium silicate blocks and earth blocks was performed to evaluate the results obtained from the standard test procedure compared to the more common practice of using earth mortars in combination with earthen blocks.
This paper presents an innovative way to combine an external ultra-high performance concrete (UHPC) supporting layer with an insulation layer of autoclaved aerated concrete (AAC) or cellular lightweight concrete (CLC) to create light-weight façade elements, which are improved in functionality and in energy efficiency. The durability of the façade elements is improved by developing UHPC with self-cleaning properties. One approach is based on the photocatalytic activation of the external UHPC shell by incorporation of TiO2 particles. The second approach consists of the modification of the UHPC surface by micro structuring in combination with the application of water-repellent agents to create durable super hydrophobicity. The current results obtained from laboratory testing are promising and demonstrate the feasibility of the approaches.
Structural performances of earthen building materials. A comparison between different typologies
(2011)
Cina
(2013)
UHPC-AAC/CLC composite panels with self-cleaning properties. Materials and production technology
(2016)
The aim of this study is to show the development of a façade composite panel combining either an autoclaved aerated concrete or a cellular lightweight concrete insulation layer with a box-type external ultra-high performance concrete (UHPC) supporting layer. The paper presents the materials characteristics of the different components and the production technology of the panel. The efficiency of surface modifications of the materials forming the external shell of the panel is reported. The activation of self-cleaning properties is described. The test results showed that the most efficient way to use the water-repellent agent is its application on the substrate before the concrete cast.
Concerning the production technology, the preliminary studies showed more advantages of a two-step manufacturing procedure of the UHPC boxes than a one-step procedure.
The goal of the present study is to assess the feasibility to develop a first reliable database of materials parameters for Earth Block Masonry (EBM). The database is crucial when defining the materials safety factors. In the first part an experimental campaign of compressive tests were carried out on two types of earth block and two types of earth mortar. The results showed that the mean variation of the compressive strength was remarkably less than expected. This low variation is related to a production with high quality standards of the materials employed. In the second part a partial safety factor for EBM under uniaxial compression was determined through the reliability method. The results proved the reliability of a common calculation method for EBM based on partial safety factors following the current standards.
From the last decades the earth construction has a growing interest due to the high sustainability (low C02 emissions), thermal and acoustic performance, fire resistance and cost of the raw material (soil). In fact, earth construction can constitute a feasible solution for a more sustainable construction industry in developed countries. Nowadays the research areas on earthen construction focus from one side on the improvement of the materials for new buildings, on the other side on the Conservation of existing architectural heritage.
Historical earthen buildings are often damaged by static or dynamic loads in form of extensive cracking. All too often these cracks are insufficiently or inappropriately repaired, if at all, because of lack of knowledge and/or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage, etc. Cracks in earthen construction can be repaired by grouting to re-establish structural continuity, and can also be used to consolidate voids and gaps, or as a complement to other strengthening techniques such as the introduction of tie-rods.
In the framework of earthen materials for new constructions, the major drawback is that traditional earthen materials are typically considered as non-standard. The great variability and heterogeneity of the properties of the available soils, the lack of quality control in the manufacturing of the earthen materials and in the construction process can be pointed out as the main reasons behind this Situation. Furthermore, only few countries issued Standards and recommendations supporting earth construction, discouraging the design of earth construction by the technical community in countries where these documents are absent.
In-plane shear behaviour of earthen materials panels strengthened with polyester fabric strips
(2016)
An experimental investigation was carried out to study the in-plane shear behaviour of earthen material panels strengthened with polyester fabric strips. Strengthened panels were developed to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. Three earthen materials were considered: cob, earth block masonry (EBM) and rammed earth (RE). As first approach the strengthening configuration, based on different adhesive materials, was tested only for cob panels. As part of the study the results of a big testing campaign of unstrengthened Panels were considered. Seven strengthened panels were tested in diagonal compression/shear.A unique reinforcement orientation was used. The results of these tests are presented in this paper, and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective in EBM panels, with increase in strength and ductility observed. In RE and cob panels the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips. Instead, in EBM it was likely that the vertical reinforcement acted in tension to restrain shear induced dilation and to restrain sliding.
China
(2017)
The contributions included in the book provide a reconnaissance on the conservation rules and current protection policies of more than 100 countries, with particular attention to the emerging nations and twentieth-century architecture. The contributions illustrate the critical issues related to architectural listings, with a brief history of national approaches, a linkography and a short bibliography. The book also provides a short critical lexicography, with 12 papers written by scholars and experts including topics on identities, heritages, conservation, memories and the economy. By examining the methods used to designate building as heritage sites across the continents, this book provides a com¬prehensive overview of current protection policies of twentieth-century architecture as well as the role of architectural history.
The aim of this study was to develop a lightweight composite façade element for refurbishment of existing façades. It was crucial to minimize the thermal bridges and to undercut the thermal requirement of the system existing façade new element. The awareness of the environmental impact of the building sector is increasing. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimized use of building area due to thinner elements and minimized maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibers. In this framework, composite elements have been developed combining an autoclaved aerated concrete insulation layer with an external UHPC supporting layer. The results show that the lightweight composite element has a good performance in term of thermal transmittance and minimization of thermal bridges.
The paper presents a comparison between different numerical modelling ap-proaches aiming to simulate the in-plain behaviour of three types of earthen materials, name-ly adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical param-eters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress–strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified approach based on macro-modelling shows a satisfactory accuracy and low computational costs. The results reproduc-ing the uniaxial compression are in good correspondence with the post-elastic behaviour ob-served in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to pre-dict the adobe masonry and rammed earth collapse mechanisms
An experimental investigation was carried out to study the in-plane shear behaviour of rammed earth structural elements strengthened with polyester fabric strips. The original idea for the retrofitting with polyester fabric strips was to introduce a vertical element for walls in order to take up horizontal loads resulting in a shear response of the building element. It has to be considered that vertical slits into the walls for fixing the strips are points of weakness and have to be mitigated by the adhesive. In this case a base coat mortar was employed. Strengthened elements were tested to exploit the strength potential of earthen materials and to solve its lack of tensile strength, significantly improving not only strength but also ductility. As part of the study results of a testing campaign of unstrengthened structural elements were considered. Strengthened elements were tested in diagonal compression/shear and cyclic shear-compression. A unique reinforcement orientation was used. The results of these tests are presented in this paper and include the load-displacement behaviours, crack patterns, failure modes. The results showed that the reinforcement was the most effective under cyclic shear-compression tests, with increase in load and displacement capacity observed. Under diagonal compression the reinforcement did not likely contribute significantly to the shear resistance, due to a lack of embedment length of the strips.
The paper investigates the dynamic characterisation along with the numerical model tuning and the seismic risk assessment of a monumental masonry tower in Italy namely the Santa Maria a Vico bell tower. Full-scale ambient vibration tests were performed under the impact of environmental loads. The technique of modal extraction in the frequency domain was applied. In-situ investigation survey was used in calibrating the refined 3D finite element model. The FEM tuning was carried out by varying the mechanical parameters and accounting for the restraint offered by the neighbouring buildings and the role of soil–structure interaction. The paper shows that the modal identification is a reliable technique that can be used in-situ for assessing the dynamic behaviour of monumental buildings. The tuned FEM model of the tower was usefully employed to determine the theoretical fundamental frequencies, which accurately fit the experiment data. Finally, the seismic performance of the bell tower was assessed using a non-linear static procedure based on the multi-modal pushover analysis and the capacity spectrum method. The results confirm that seismic events of moderate intensity can produce heavy damage to the masonry tower presented in this study.
The paper presents a comparison between different numerical modelling approaches aiming to simulate the in-plain behaviour of three types of earthen materials, namely adobe masonry, rammed earth and cob. For this purpose, uniaxial and diagonal compression tests were carried out, which allowed determining important mechanical parameters, such as compressive strength, Young’s modulus, Poisson’s ratio, shear strength and shear modulus. Furthermore, the tests allowed assessing the level of non-linear behaviour of the respective stress strain relationships as well as the failure modes. The experimental results were then used for the calibration of numerical models (based on the finite element method) for simulating the non-linear behaviour of the earth materials under in-plane shear loading. Both macro- and micro-modelling approaches were considered for this purpose. The procedures adopted for model calibration established the reliability of various modelling strategies for the different loading conditions. The simplified Approach based on macromodelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with higher computational cost, represents a suitable tool to predict the adobe masonry and rammed earth collapse mechanisms.
In the last decades it has been necessary to face emergencies due to big crisis events caused by anthropic and natural events. In particular modern technological Systems have reached such a high level of complexity that even a simple event can influence correct behavior with potential catastrophic consequences. The security and economy of technologically developed countries depends on the correct behavior of this infrastructure and on the continuity of the Services that they grant.
In this framework, risk management assumes an important role focusing on policies for vulnerability reduction and after-crisis management. It imposes a multidisciplinary and transnational approach in Order to establish a common strategy between different countries, studying how to be prepared for disasters and prevent disaster damage. In this paper a preliminary analysis of risk categories is presented, suggesting a number of tentative proposals for risk reduction.
The purpose of this paper is to numerically simulate the in-plane behaviour of rammed earth walls under cyclic shear-compression tests. The experimental testing allowed obtaining the maximum horizontal loads, the displacement capacity and the level of non-linear behaviour of the respective loaddisplacement relationships as well as the failure modes. The calibration of the numerical model (finite element method) was carried out based on the experimental results. Within this framework, a micromodelling approach was considered. The behaviour of the rammed earth material was simulated using a total strain rotating crack model. A Mohr-Coulomb failure criterion was used to reproduce the behaviour of the interfaces between the layers.
Although the numerical results achieved a satisfactory agreement with the experimental results a sensitivity analysis of the parameters involved was performed. The sensitivity analysis aimed at determining which parameters of the model have a significant impact in the model’s results. As expected the sensitivity analysis pointed out that the sliding failure occurrence is mainly influenced by two parameters of the interface elements: the interface tensile strength fit and the friction angle u. Moreover the cohesion c and the layers thickness showed a limited effect on the shear behaviour. It should be noted that the results mentioned above are related to the cases where a significant level of vertical compressive stress r is employed.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behavior of the single structural elements as well as to their mutual connections. Up to now only few data are available about the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate. In this paper, results of the experimental testing performed on earth block masonry, rammed earth and cob are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel rods with a lime based hydraulic grout and their compatibility with earthen materials. Rods with nuts were investigated to improve the pull-out capacity of the anchors. They showed higher pull-out capacity than rods without nuts. The performances of rods with nuts in cob were influenced by the rough surface at/of the earthen substrate. It is assumed that the non homogeneous surface caused an interlocking mechanism, which allowed to reach a pull-out capacity of about 54% higher than in earth block masonry.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behaviour of the single structural elements as well as by their mutual connections. Up to now limited data is available on the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate.
In this paper results of the experimental testing performed on earth block masonry are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel as well as glass fiber reinforced polymer (GFRP) rods with a lime based hydraulic grout and their compatibility with earth block masonry. GFRP rods were investigated as an alternative bonded-in anchorage material to the commonly used steel. In comparison with steel, they have a reduced weight and a reduced coefficient of thermal expansion. Their lower modulus of elasticity seems to be more compatible with the modulus of elasticity of earthen materials, although they exhibit a brittle fracture with lack of plastic phase.
This study presents diagnostic techniques to assess the structural vulnerability of earthen buildings. Medieval structures at Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military Orders, provide a useful case study. After more than a thousand years of construction, failure and repair from the 10th century to the present day, Ambel preceptory today is characterised by marked inhomogeneities: construction materials and structural typologies are juxtaposed, with structural discontinuities at the interfaces between construction phases. This paper argues that, while static analysis is an essential prerequisite before a suitable maintenance program can be defined, no evaluation of the structural behaviour of any historic building can ignore an understanding of the building’s history.