Filtern
Dokumenttyp
- Vortrag (12)
- Zeitschriftenartikel (6)
- Beitrag zu einem Tagungsband (6)
- Posterpräsentation (5)
- Corrigendum (1)
Schlagworte
- SealWasteSafe (13)
- Monitoring (11)
- Ultrasound (9)
- Engineered barrier systems (5)
- Imaging (5)
- Ultraschall (5)
- Ultrasonic imaging (4)
- Verschlussbauwerke (4)
- Abbildungsverfahren (3)
- Borehole (3)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (29)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (27)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 8.6 Faseroptische Sensorik (3)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 8.0 Abteilungsleitung und andere (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
Eingeladener Vortrag
- nein (12)
Reliable assessment of earthen dams’ stability and tailing storage facilities widely used in the mining industry is challenging, particularly under seismic load conditions. In this paper, we propose to take into account the effect of the dominant frequency of seismic load on the stability assessment of tailing/earthen dams. The calculations are performed by finite element modelling (FEM) with the Mohr–Coulomb failure criteria. To separate the frequency content from other dynamic parameters describing the seismic wave, synthetic waveforms with identical amplitude and attenuation characteristics, but differing spectral characteristics have been used. The analysis has been performed for three different slope angles and two scenarios of seismic wave propagation. Consequently, the changes of total displacement and shear stresses depending on the frequencies have been determined and clearly show that lower frequencies cause higher stress levels and displacement. Finally, the response surface methodology has been applied to determine how different parameters affect the slope stability under dynamic load conditions. Overall, this study is a first step to improve the existing methods to assess slope stability when considering seismic load.
During the webinar "Dismantling and waste management: a playground for innovation" the innovative aspects of the PREDIS work package "innovations in cemented waste handling and pre-disposal storage" are presented. The webinar is jointly organised by Women in Nuclear Decommissioning (WINDI) and Women in Nuclear Innovation (WINI). The shown innovations include quality assurance (mainly NDE) and monitoring technologies with associated sensor systems, digital twin technology, and appropriate data handling including a decision framework. An overview of the on-going research in the field of pre-disposal waste management in the project Predis (WP7) is summarised.
Within the project SealWasteSafe, we advance construction materials and non-destructive monitoring concepts of sealing structures applied for underground disposal of nuclear waste. As these engineered barriers have high demands regarding structural integrity, an innovative alkali-activated material (AAM) that is highly suitable for the application in salt as a host rock is improved and tested on two laboratory scales. This AAM has a low heat evolution due to the reaction mechanism in comparison to common salt concretes based on Portland cement or magnesium oxychloride binders. Hence, crack formation due to thermally induced stress during the hardening process is reduced.
After successful laboratory tests with small specimens (height ~5 cm), comparably manufactured large cubic (edge length 70 cm) and cylindrical specimens (height 120 cm, diameter 40 cm) are equipped with sensing technologies to demonstrate the sensors´ technical capabilities. A comprehensive multi-sensory monitoring scheme is developed and investigated to characterize and compare the different material behaviour during the setting and hardening process of two materials: (1) the newly developed AAM-based mortars with salt aggregate, and (2) a blended Portland cement-based salt concrete as reference. The analysed parameters include temperature and humidity of the material, acoustic emissions, and strain variations recorded by fiber optic cables. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete provide an interface for the wireless readout of various sensors. In parallel to the embedded RFID sensors, conventional cabled systems to read out the temperature and humidity measurements are installed for comparison. Additionally, a detailed inspection of the two large cubic specimens after a monitoring period of more than six months has been undertaken. Active thermography and ultrasonic echo measurements are used to reveal potentially occurring inner cracks from the surface. To verify the non-invasive results, a core sample (diameter 2 cm) was extracted from each of the investigated cubic specimens and analysed in detail with X-ray computed tomography.
Furthermore, ultrasonic methods are used for quality assurance to detect obstacles, cracks, and delamination at in-situ scale sealing structures. Experimental layout and applied imaging techniques are optimised to enhance the image quality for measurements from the front side of the engineered barrier. To characterize the inside of the test sealing structure and to improve the detection of potentially existing cracks, an ultrasonic borehole probe using the phased array technique is developed. First analyses at a half-spherical specimen coincide with modelling results and prove the reliability of the directional response caused by the phased array technique of the newly constructed ultrasonic borehole probe. Overall, the project SealWasteSafe helps to characterize construction materials and improves multi-sensory monitoring concepts and ultrasonic equipment for the sake of quality assurance. Particularly for salt as a host rock, this will help to design safe sealing structures for nuclear waste disposal.
Multifaceted developments for pre-disposal management of low and intermediate level radioactive waste are undertaken in the EC funded project PREDIS. In work package 7, innovations in cemented waste handling and pre-disposal storage are advanced by testing and evaluating. To provide better means for safe and effective monitoring of cemented waste packages including prediction tools to assess the future integrity development during pre-disposal activities, several monitoring and digital tools are evaluated and improved. Both safety enhancement (e. g. less exposure of testing personnel) and cost effectiveness are part of the intended impact. Current methods to pack, store, and monitor cemented wastes are identified, analysed and improved. Innovative integrity testing and monitoring techniques applied to evaluate and demonstrate package and storage quality assurance are further developed. The work includes but is not limited to inspection methods such as muon imaging, wireless sensors integrated into waste packages as well as external package and facility monitoring such as remote fiber optical sensors. The sensors applied will go beyond radiation monitoring and include proxy parameters important for long term integrity assessment (e. g. internal pressure). The measured data will be used in digital twins of the packages for specific simulations (geochemical, integrity) providing a prediction of future behaviour. Machine Learning techniques trained by the characterization of older packages will help to connect the models to the actual data. As data handling, processing and fusion are crucial for both the monitoring and the digital twin model, all data (measured and simulated) will be collected in a joint data base and connected to a decision framework. Finally, the implementation of the improved techniques will be tested at actual facilities. An overview about various relevant tools, their interconnections, and first research results will be shown.
The project "SealWasteSafe" of the Bundesanstalt für Materialforschung und -prüfung (BAM, Berlin) deals with sealing structures applied for underground disposal of nuclear waste from two perspectives: (1) material improvement for application in sealing constructions and (2) feasibility study regarding multi-sensor approaches to ensure quality assurance and long-term monitoring.
One specimen of 150 l made of alkali-activated material, which was found innovative and suitable for sealing constructions based on preliminary laboratory studies, and, for comparison purpose, another one made of salt concrete, are manufactured with an integrated multi-sensory setup for quality assurance and long-term-monitoring. The specimens were left in their cast form and additionally thermally insulated to simulate the situation in the repository. The multi-sensory concept comprises RFID technology embedded in the specimens suppling material temperature and moisture measurements, integrated fibre optic sensing allowing strain measurement and acoustic emission testing for monitoring possible crack formation. Overall, the suitability and the functionality of the sensors embedded into and attached to strongly alkaline (pH > 13 for the AAM) and salt corrosive (NaCl) environment was proven for the first 672 h.
First temperature measurement based on RFID succeeded after 626 h for the alkali-activated material and after 192 h for the conventional salt concrete. Strain measurement based on distributed fibre optic sensing turned out the alkali-activated material with > 1 mm m-1 undergoing approximately twice the compression strain as the salt concrete with strains < 0.5 mm m-1. In contrast, the acoustic emission first and single hits representing crack formation in numbers, was found for alkali-activated material half of that detected at the salt concrete.
The project "SealWasteSafe" of the Bundesanstalt für Materialforschung und -prüfung (Berlin) deals with sealing structures applied for underground disposal of nuclear waste from two perspectives: material improvement for application in sealing constructions and feasibility study regarding multi-sensor approaches to ensure quality assurance and long-term monitoring.
One specimen of 150 l made of alkali-activated material, which was found innovative and suitable for sealing constructions based on preliminary laboratory studies, and another one made of conventional salt concrete, are manufactured with an integrated multi-sensory setup for quality assurance and long-term-monitoring. The specimens were left in their cast form and additionally thermally insulated to simulate the situation in the repository. The multi-sensory concept comprises RFID technology embedded in the specimens suppling material temperature and moisture measurements, integrated distributed fibre optic sensing allowing strain measurement and acoustic emission testing for monitoring crack formation. Overall, the suitability and the functionality of the sensors embedded into and attached to strongly alkaline (pH > 13 for the AAM) and salt corrosive (NaCl) environment was proven for the first 672 h.
First RFID measurement succeeded after 626 h for the alkali-activated material and after 192 h for the conventional salt concrete. Strain measurement based on fibre optic sensing turned out the alkali-activated material (> 1 mm/m) undergoing approximately twice the compression strain as the salt concrete (< 0.5 mm/m). In contrast, the acoustic emission first and single hits representing crack formation in numbers, was found for alkali-activated material half of that detected at the salt concrete.
Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures
(2023)
Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring and inspection techniques within the project SealWasteSafe.
After successful laboratory analysis on the cm-scale, cylindrical and cuboid specimens on the m-scale are produced from classical salt concrete and a specifically developed alkali-activated material. A comprehensive multi-sensory monitoring scheme is applied to compare the setting process of both materials and to demonstrate the sensors’ resistance to highly alkaline environments. Besides temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than 8 months. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete allow for wireless access to temperature and humidity measurements and are compared to conventional cabled systems. After hardening and removal of the outer casings of the specimens, further non-destructive evaluations using ultrasonic echo and thermographic measurements are conducted. Preliminary results clearly highlight differences between the tested materials, particularly showing lower acoustic emission activity for the newly developed alkali-activated material potentially indicating less phase changes or cracks.
Complementary, ultrasonic methods are improved to be used for quality assurance to detect obstacles, potential cracks and delamination at in-situ sealing structure scale. A unique large aperture ultrasonic system (LAUS) with depth penetration as large as 9 m has already successfully been applied at the test site in Morsleben, Germany, of the federal company for radioactive waste disposal (BGE). Modelling studies help to further optimize the measurement layout. Advanced imaging techniques applied to the modelled and measured data will further improve the obtained images of internal structures. Additionally, an ultrasonic borehole probe is developed and constructed using phased arrays to further enhance the detection of potential cracks. Modelling and preliminary results from laboratory specimens prove the feasibility and potential of the directional response even in heterogeneous material such as concrete. Final investigations under in-situ conditions at the test site of the sealing structure are planned.
Overall, the project SealWasteSafe improves the construction material, multi-sensory monitoring, and ultrasound for quality assurance to allow for the development of safe nuclear sealing structures. Although the techniques are tailored for sealing structures within salt as a host rock, they are transferrable to a wider field of applications and alternative disposal conditions.
Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures
(2023)
Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring, and inspection techniques within the project SealWasteSafe. A specifically developed alkali-activated material is compared to classical salt concrete. A comprehensive multi-sensory monitoring scheme is used at 150-340 l specimens to monitor setting and hardening of both materials. All sensors are demonstrated to resist the highly alkaline environments. Besides cabled and wireless temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than eight months. After hardening of the specimens, further nondestructive evaluations using ultrasonic echo and thermographic measurements are conducted.
Preliminary results proof the suitability of the tested sensors and clearly highlight differences between the tested materials. Particularly, the newly developed alkali-activated material shows lower acoustic emission activity indicating less cracking activity. Additionally, unique ultrasonic methods will enable better images of potential internal objects and cracks at in-situ sealing structures. A largescale ultrasonic system is optimised to reliably detect objects at a depth exceeding 9 m while still obtaining a good resolution. Modelling studies show the potential of further increasing the distance between individual transducer arrays. Additionally, a new ultrasonic borehole probe using phased arrays allowing for beam focussing is constructed and tested. Laboratory measurements at a halfcylindrical concrete specimen coincide well with the previous modelling. In total, the presented safe materials, detailed monitoring approaches and ultrasonic quality assurance methods will help to obtain safe sealing structures within salt as a host rock. The concepts can partly be transferred to sealing structures in alternative host rocks and will also be valuable for non-nuclear waste repositories.
New materials and innovative monitoring for safe sealing structures in underground repositories
(2022)
Within the project SealWasteSafe, we advance construction materials and monitoring concepts of sealing structures applied for underground disposal of nuclear waste. As these engineered barriers have high demands concerning integrity, an innovative alkali-activated material (AAM) is improved and tested on various laboratory scales that is highly suitable for the application in salt as a host rock. This AAM has a low reaction kinetics related to a preferential slow release of the heat of reaction in comparison to alternative salt concretes based on Portland cement or magnesium oxychloride cements. Hence, crack formation due to thermally induced strain is reduced. A comprehensive multi-sensory monitoring scheme is developed and investigated to compare the setting process of AAM and salt concrete for manufactured specimens (100-300 l). The analysed parameters include temperature and humidity of the material, acoustic emissions, and strain variations recorded by fiber optic cables. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete allow for wireless access and are compared to conventional cabled systems for temperature and humidity measurements. Furthermore, ultrasonic methods are used for quality assurance to detect obstacles, potential cracks and delamination. Field layout and applied imaging techniques are optimised to enhance the image quality. To characterise the inside of the test engineered barrier and achieve a proof-of-concept, an ultrasonic borehole probe is developed to allow for phased arrays that can further improve the detection of potential cracks. Modelling results and first analysis of half-spherical specimen prove the reliability of the directional response caused by the phased arrays of the newly constructed ultrasonic borehole probe. Overall, the project SealWasteSafe improves the construction material, multi-sensory monitoring concepts and ultrasonics for quality assurance. Particularly for salt as a host rock, this will help to develop safe sealing structures for nuclear waste disposal.
Ultrasonic echo testing is a well-established non-destructive testing technique used to investigate the interior of concrete structures in civil engineering. For the reconstruction of internal features, methods similar to seismic imaging are applied. To improve the ultrasonic imaging capabilities, we investigate the potential of a newly available 3D matrix mode measurement device in combination with advanced imaging techniques.
Commonly used ultrasonic array measurement devices rely on several ultrasonic transducers coupled to act as one transducer that transmits or receives transversal ultrasound waves. Although this approach is well suited to detect elongated structures such as pipes and rebars, it has limitations if 3D embedded objects are present. Hence, the ultrasonic device MiraA1040Pro used here is designed to measure the ultrasonic wavefield on a 4 by 16 matrix of individual transducers. For testing, we used laboratory specimens with linear and spheric embedded structures first. Both linear and matrix mode measurements were conducted and analysed using the Synthetic Aperture Focusing Technique
(SAFT) which is similar to Kirchhoff migration. Second, we used a data set from Teutschenthal mine at a shotcrete specimen constructed to simulate engineered barriers tailored for nuclear waste repositories. Ultrasonic measurements were investigated as a tool for quality assurance of these structures. The specimen contains both artificial 3D artifacts as well as naturally occurring defects such as a delamination. To make use of the advanced data acquisition, focusing 3D imaging techniques are applied to further improve the imaging quality.
Generally, the reconstructed images from the 3D matrix mode data have a lower level of Signal-to-Noise-Ratio than the 2D linear mode because the source signal is weaker compared to the linear mode. Moreover, complex wave conversions of the SH-transversal wave occur that are reduced in the 2D linear scenario. However, clearer images can be achieved at non-linear features, particularly with focusing imaging methods. Thus, combining 3D data acquisition techniques with advanced imaging methods improves the success in imaging complex concrete structures. This is of particular interest for thick concrete structures in nuclear barrier systems or foundations. Additionally, we demonstrate opportunities to use well-constrained test laboratory scenarios from non-destructive testing as a practical test case for geophysical methods.