Filtern
Dokumenttyp
- Vortrag (12)
- Zeitschriftenartikel (6)
- Beitrag zu einem Tagungsband (6)
- Posterpräsentation (5)
- Corrigendum (1)
Schlagworte
- SealWasteSafe (13)
- Monitoring (11)
- Ultrasound (9)
- Engineered barrier systems (5)
- Imaging (5)
- Ultraschall (5)
- Ultrasonic imaging (4)
- Verschlussbauwerke (4)
- Abbildungsverfahren (3)
- Borehole (3)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (29)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (27)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 8.6 Faseroptische Sensorik (3)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 8.0 Abteilungsleitung und andere (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
Eingeladener Vortrag
- nein (12)
The project "SealWasteSafe" of the Bundesanstalt für Materialforschung und -prüfung (BAM, Berlin) deals with sealing structures applied for underground disposal of nuclear waste from two perspectives: (1) material improvement for application in sealing constructions and (2) feasibility study regarding multi-sensor approaches to ensure quality assurance and long-term monitoring.
One specimen of 150 l made of alkali-activated material, which was found innovative and suitable for sealing constructions based on preliminary laboratory studies, and, for comparison purpose, another one made of salt concrete, are manufactured with an integrated multi-sensory setup for quality assurance and long-term-monitoring. The specimens were left in their cast form and additionally thermally insulated to simulate the situation in the repository. The multi-sensory concept comprises RFID technology embedded in the specimens suppling material temperature and moisture measurements, integrated fibre optic sensing allowing strain measurement and acoustic emission testing for monitoring possible crack formation. Overall, the suitability and the functionality of the sensors embedded into and attached to strongly alkaline (pH > 13 for the AAM) and salt corrosive (NaCl) environment was proven for the first 672 h.
First temperature measurement based on RFID succeeded after 626 h for the alkali-activated material and after 192 h for the conventional salt concrete. Strain measurement based on distributed fibre optic sensing turned out the alkali-activated material with > 1 mm m-1 undergoing approximately twice the compression strain as the salt concrete with strains < 0.5 mm m-1. In contrast, the acoustic emission first and single hits representing crack formation in numbers, was found for alkali-activated material half of that detected at the salt concrete.
Reliable assessment of earthen dams’ stability and tailing storage facilities widely used in the mining industry is challenging, particularly under seismic load conditions. In this paper, we propose to take into account the effect of the dominant frequency of seismic load on the stability assessment of tailing/earthen dams. The calculations are performed by finite element modelling (FEM) with the Mohr–Coulomb failure criteria. To separate the frequency content from other dynamic parameters describing the seismic wave, synthetic waveforms with identical amplitude and attenuation characteristics, but differing spectral characteristics have been used. The analysis has been performed for three different slope angles and two scenarios of seismic wave propagation. Consequently, the changes of total displacement and shear stresses depending on the frequencies have been determined and clearly show that lower frequencies cause higher stress levels and displacement. Finally, the response surface methodology has been applied to determine how different parameters affect the slope stability under dynamic load conditions. Overall, this study is a first step to improve the existing methods to assess slope stability when considering seismic load.
The internal project "SealWasteSafe" of the Federal Institute for Materials Research and Testing is dedicated to the further improvement in the construction of sealing systems for underground repositories of radioactive waste. Particularly, a multi-sensory concept is developed to ensure quality assurance and continuous long-term monitoring on the engineered barriers. Therefore, beside other measures, the temperature and equilibrium moisture of the construction shall be monitored and respective multi-sensoric monitoring concepts are tested first on the laboratory scale. One focus in this project is on embedded application in alkali-activated mortars (AAM), which results in special requirements for the resistance of the sensors to strongly alkaline environments with up to pH 14. In addition, the ingress of water along cables or at sensor positions is critical for sensors embedded in concrete, as the cable access of the sensor housing is a major weak point. It is therefore advisable to equip wireless high frequent radio frequency identification-based sensors, so called HF RFID sensors (short: RFID), that do not require cable access and thus have a stable and leak-proof sensor housing for long-term monitoring. In this contribution, the results from temperature, moisture and transmitted power monitoring of a AAM and a M2 specimens by means of HF RFID sensor systems are presented.
Monitoring of repositories for radioactive waste requires techniques which can be applied long-term under harsh conditions. In this work, the reliability and suitability of materials and a capacitive sensor for measuring relative humidity are investigated, which are to be embedded in the special concrete components for the closure structures of underground repository. Preliminary tests with accelerated aging of the materials used, validation of the sensors under difficult conditions, investigations of the surfaces after aging by pH 14 solution, defined exposure of the sensors in a climatic chamber and the microscope images are discussed. The results will be used for further development and optimization of the RFID based sensor systems which can be applied to monitor the condition of different building structures without cabling.
Verschlussbauwerke sind für die untertägige Endlagerung im Salzgestein als eine wichtige technische Barriere vorgesehen. Diese Bauwerke müssen hohen Anforderungen an Sicherheit und Integrität genügen, weshalb im Projekt SealWasteSafe Werkstofftechnik, Prüfverfahren und Überwachungsmethoden für sichere Verschlussbauwerke verbessert werden. Dabei zeigen die untersuchten alkaliaktivierten Materialien (AAM) langsamere Reaktionskinetik bei der Erhärtung im Vergleich zu Salzbeton, was potenziell geringere Rissbildung erwarten lässt. Die Erhärtung wird an Probekörpern (100-300 l) multisensorisch über einen Zeitraum von mindestens 28 Tagen überwacht. Die Parameter Temperatur und Feuchtigkeit werden einerseits kabelgebunden, andererseits mittels drahtloser Radio Frequency Identification (RFID)-Technik aufgezeichnet. Zusätzlich kommen Schallemissionsmessungen sowie Dehnungsmessungen mittels verteilter faseroptischer Sensorik (FOS) zum Einsatz. Die Überwachung zeigt verschiedene Charakteristika beim Erhärten der Materialien mit geringerer Temperaturentwicklung des AAM. Zusätzlich werden Ultraschallmessungen genutzt, um Einbauteile und Störstellen wie Risse und Delaminationen im Rahmen der Qualitätssicherung am Probekörper und am Verschlussbauwerk zu detektieren. Dafür werden sowohl ein Ultraschallmesssystem mit großer Apertur (LAUS) als auch eine Ultraschall-Bohrlochsonde eingesetzt. Durch Erhöhung des Schalldrucks und Schallfeldbündelung im Beton wird die Aussagekraft der von der Bohrlochsonde aufgezeichneten Messsignale verbessert, was in Modellierungen und ersten Labortests gezeigt werden kann. Die Auswertung der Ultraschallmessungen zeigt das große Potenzial der Methode mit Eindringtiefen bis zu 9 m, wobei anspruchsvolle Abbildungsverfahren zu einer verbesserten Abbildung der internen Strukturen führen. Insgesamt verbessern die im Projekt SealWasteSafe entwickelten Materialien und Methoden die Möglichkeiten für sichere Verschlussbauwerke nuklearer Endlager. Obwohl die Konzepte speziell für Bauwerke im Salzgestein entwickelt werden, sind sie partiell gut auf andere Wirtsgesteine übertragbar.
Within the project SealWasteSafe, we advance construction materials and monitoring concepts of sealing structures applied for underground disposal of nuclear or toxic waste. As these engineered barriers have high demands concerning integrity, an innovative alkali-activated material (AAM) is improved and tested on various laboratory scales. This AAM has low reaction kinetics related to a preferential slow release of the heat of reaction in comparison to alternative salt concretes based on Portland cement or magnesium oxychloride cements. Hence, crack formation due to thermally induced strain is reduced. After successful laboratory scale analysis (Sturm et al., 2021), the AAM is characterised on a larger scale by manufacturing test specimens (100–300 L).
Conventional salt concrete (DBE, 2004) and the newly developed AAM are compared using two specimen geometries, i.e. cylindrical and cuboid. A comprehensive multisensor monitoring scheme is developed to compare the setting process of AAM and salt concrete for these manufactured specimens. The analysed parameters include temperature and humidity of the material, acoustic emissions, and strain variations. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete, enable wireless access to temperature and humidity measurements and are compared to conventional cabled systems. Additionally, fibre-optic sensors (FOS) are embedded to record strain, but also have potential to record temperature and moisture conditions. Part of this project aims at demonstrating the high reliability of sensors and also their resistance to highly alkaline environments and to water intrusion along cables or at sensor locations. Further technical improvements were implemented so that first results clearly show the scalability of the setting process from previous small-scale AAM experiments and particularly the high potential of the newly developed approaches.
Furthermore, ultrasonic methods are used for quality assurance to detect obstacles, potential cracks and delamination. On the one hand, both active and passive ultrasonic measurements complement the results obtained from the multisensor monitoring scheme for the produced specimens. On the other hand, the unique large aperture ultrasonic system (LAUS) provides great depth penetration (up to nearly 10 m) and can thus be applied at in situ sealing structures built as a test site in Morsleben by the Federal Company for Radioactive Waste Disposal (Bundesgesellschaft für Endlagerung, BGE) as shown by Effner et al. (2021). An optimised field lay-out identified from forward modelling studies and advanced imaging techniques applied to the measured data will further improve the obtained results. To characterise the inside of the test engineered barrier and achieve a proof-of-concept, an ultrasonic borehole probe is developed to enable phased arrays that can further improve the detection of potential cracks. Modelling results and first analysis of semispherical specimens confirmed the reliability of the directional response caused by the phased arrays of the newly constructed ultrasonic borehole probe.
Overall, the project SealWasteSafe improves the construction material, multisensor monitoring concepts and ultrasonics for quality assurance. This will help to develop safe sealing structures for nuclear waste disposal. The outcomes are particularly valuable for salt as a host rock but partly also transferrable to alternative conditions.
The Alpine Fault at the West Coast of the South Island (New Zealand) is a major plate boundary that is expected to rupture in the next 50 years, likely as a magnitude 8 earthquake. The Deep Fault Drilling Project (DFDP) aimed to deliver insight into the geological structure of this fault zone and its evolution by drilling and sampling the Alpine Fault at depth. Here we present results from a seismic survey around the DFDP-2 drill site in the Whataroa Valley where the drillhole almost reached the fault plane. This unique 3D seismic survey includes several 2D lines and a 3D array at the surface as well as borehole recordings. Within the borehole, the unique option to compare two measurement systems is used: conventional three-component borehole geophones and a fibre optic cable (heterodyne Distributed Vibration Sensing system (hDVS)). Both systems show coherent signals but only the hDVS system allowed a recording along the complete length of the borehole.
Despite the challenging conditions for seismic imaging within a glacial valley filled with sediments and steeply dipping valley flanks, several structures related to the valley itself as well as the tectonic fault system are imaged. The pre-processing of the seismic data also includes wavefield separation for the zero-offset borehole data. Seismic images are obtained by prestack depth migration approaches.
Within the glacial valley, particularly steep valley flanks are imaged directly and correlate well with results from the P-wave velocity model obtained by first arrival travel-time tomography. Additionally, a glacially over-deepened trough with nearly horizontally layered sediments is identified about 0.5 km south of the DFDP-2B borehole.
With regard to the expected Alpine fault zone, a set of several reflectors dipping 40-56° to the southeast are identified in a ~600 m wide zone between depths of 0.2 and 1.2 km that is interpreted to be the minimum extent of the damage zone. Different approaches image one distinct reflector dipping at 40°, which is interpreted to be the main Alpine Fault reflector. This reflector is only ~100 m ahead from the lower end of the borehole. At shallower depths (z<0.5 km), additional reflectors are identified as fault segments and generally have steeper dips up to 56°. About 1 km south of the drill site, a major fault is identified at a depth of 0.1-0.5 km that might be caused by the regional tectonics interacting with local valley structures. A good correlation is observed among the separate seismic data sets and with geological results such as the borehole stratigraphy and the expected surface trace of the fault.
In conclusion, several structural details of the fault zone and its environment are seismically imaged and show the complexity of the Alpine Fault at the Whataroa Valley. Thus, a detailed seismic characterization clarifies the subsurface structures, which is crucial to understand the transpressive fault’s tectonic processes.
Im Rahmen des Seminars "Angewandte Forschungsthemen (SAFT)" am Institut für Geowissenschaften der Christian-Albrechts-Universität zu Kiel werden verschiedene geophysikalische Methoden vorgestellt, die bei der zerstörungsfreien Prüfung im Bauwesen zum Einsatz kommen. Neben einem Überblick der Arbeiten an der BAM im Allgemeinen und dem Fachbereich im Besonderen geht es vor allem um den Einsatz von Ultraschallmethoden. Drei wesentliche Schwerpunkte werden dabei beleuchtet:
1) (Geophysikalische) Antworten auf Herausforderungen bei Ultraschall-Anwendungen
2) Material research and multi-sensory monitoring for concrete sealing structures in rock salt unterground repositories (Projekt SealWasteSafe)
und 3) Untersuchung von Spritzbeton-Probekörpern unter Tage mit Ultraschall zur Qualitätssicherung von Verschlussbauwerken.
Insgesamt werden diverse Möglichkeiten für die Geophysik für Forschung und Studierende im Bereich der zerstörungsfreien Prüfung im Bauwesen aufgezeigt.
During the webinar "Dismantling and waste management: a playground for innovation" the innovative aspects of the PREDIS work package "innovations in cemented waste handling and pre-disposal storage" are presented. The webinar is jointly organised by Women in Nuclear Decommissioning (WINDI) and Women in Nuclear Innovation (WINI). The shown innovations include quality assurance (mainly NDE) and monitoring technologies with associated sensor systems, digital twin technology, and appropriate data handling including a decision framework. An overview of the on-going research in the field of pre-disposal waste management in the project Predis (WP7) is summarised.