Filtern
Dokumenttyp
- Vortrag (9)
- Zeitschriftenartikel (6)
- Beitrag zu einem Tagungsband (6)
- Posterpräsentation (3)
Sprache
- Englisch (24) (entfernen)
Schlagworte
- Monitoring (9)
- SealWasteSafe (9)
- Ultrasound (9)
- Engineered barrier systems (5)
- Imaging (5)
- Ultrasonic imaging (4)
- Borehole (3)
- Borehole probe (3)
- Engineered barrier (3)
- Engineered barriers (3)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (24) (entfernen)
Eingeladener Vortrag
- nein (9)
Monitoring of repositories for radioactive waste requires techniques which can be applied long-term under harsh conditions. In this work, the reliability and suitability of materials and a capacitive sensor for measuring relative humidity are investigated, which are to be embedded in the special concrete components for the closure structures of underground repository. Preliminary tests with accelerated aging of the materials used, validation of the sensors under difficult conditions, investigations of the surfaces after aging by pH 14 solution, defined exposure of the sensors in a climatic chamber and the microscope images are discussed. The results will be used for further development and optimization of the RFID based sensor systems which can be applied to monitor the condition of different building structures without cabling.
Reliable assessment of earthen dams’ stability and tailing storage facilities widely used in the mining industry is challenging, particularly under seismic load conditions. In this paper, we propose to take into account the effect of the dominant frequency of seismic load on the stability assessment of tailing/earthen dams. The calculations are performed by finite element modelling (FEM) with the Mohr–Coulomb failure criteria. To separate the frequency content from other dynamic parameters describing the seismic wave, synthetic waveforms with identical amplitude and attenuation characteristics, but differing spectral characteristics have been used. The analysis has been performed for three different slope angles and two scenarios of seismic wave propagation. Consequently, the changes of total displacement and shear stresses depending on the frequencies have been determined and clearly show that lower frequencies cause higher stress levels and displacement. Finally, the response surface methodology has been applied to determine how different parameters affect the slope stability under dynamic load conditions. Overall, this study is a first step to improve the existing methods to assess slope stability when considering seismic load.
The Alpine Fault zone in New Zealand marks a major transpressional plate boundary that is late in its typical earthquake cycle. Understanding the subsurface structures is crucial to understand the tectonic processes taking place. A unique seismic survey including 2D lines, a 3D array, and borehole recordings, has been performed in the Whataroa Valley and provides new insights into the Alpine Fault zone down to ∼2 km depth at the location of the Deep Fault Drilling Project (DFDP)-2 drill site. Seismic images are obtained by focusing prestack depth migration approaches. Despite the challenging conditions for seismic imaging within a sediment filled glacial valley and steeply dipping valley flanks, several structures related to the valley itself as well as the tectonic fault system are imaged. A set of several reflectors dipping 40°–56° to the southeast are identified in a ∼600 m wide zone that is interpreted to be the minimum extent of the damage zone. Different approaches image one distinct reflector dipping at ∼40°, which is interpreted to be the main Alpine Fault reflector located only ∼100 m beneath the maximum drilled depth of the DFDP-2B borehole. At shallower depths (z < 0.5 km), additional reflectors are identified as fault segments with generally steeper dips up to 56°. Additionally, a glacially over-deepened trough with nearly horizontally layered sediments and a major fault (z < 0.5 km) are identified 0.5–1 km south of the DFDP-2B borehole. Thus, a complex structural environment is seismically imaged and shows the complexity of the Alpine Fault at Whataroa.
Within the project SealWasteSafe, we advance construction materials and monitoring concepts of sealing structures applied for underground disposal of nuclear or toxic waste. As these engineered barriers have high demands concerning integrity, an innovative alkali-activated material (AAM) is improved and tested on various laboratory scales. This AAM has low reaction kinetics related to a preferential slow release of the heat of reaction in comparison to alternative salt concretes based on Portland cement or magnesium oxychloride cements. Hence, crack formation due to thermally induced strain is reduced. After successful laboratory scale analysis (Sturm et al., 2021), the AAM is characterised on a larger scale by manufacturing test specimens (100–300 L).
Conventional salt concrete (DBE, 2004) and the newly developed AAM are compared using two specimen geometries, i.e. cylindrical and cuboid. A comprehensive multisensor monitoring scheme is developed to compare the setting process of AAM and salt concrete for these manufactured specimens. The analysed parameters include temperature and humidity of the material, acoustic emissions, and strain variations. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete, enable wireless access to temperature and humidity measurements and are compared to conventional cabled systems. Additionally, fibre-optic sensors (FOS) are embedded to record strain, but also have potential to record temperature and moisture conditions. Part of this project aims at demonstrating the high reliability of sensors and also their resistance to highly alkaline environments and to water intrusion along cables or at sensor locations. Further technical improvements were implemented so that first results clearly show the scalability of the setting process from previous small-scale AAM experiments and particularly the high potential of the newly developed approaches.
Furthermore, ultrasonic methods are used for quality assurance to detect obstacles, potential cracks and delamination. On the one hand, both active and passive ultrasonic measurements complement the results obtained from the multisensor monitoring scheme for the produced specimens. On the other hand, the unique large aperture ultrasonic system (LAUS) provides great depth penetration (up to nearly 10 m) and can thus be applied at in situ sealing structures built as a test site in Morsleben by the Federal Company for Radioactive Waste Disposal (Bundesgesellschaft für Endlagerung, BGE) as shown by Effner et al. (2021). An optimised field lay-out identified from forward modelling studies and advanced imaging techniques applied to the measured data will further improve the obtained results. To characterise the inside of the test engineered barrier and achieve a proof-of-concept, an ultrasonic borehole probe is developed to enable phased arrays that can further improve the detection of potential cracks. Modelling results and first analysis of semispherical specimens confirmed the reliability of the directional response caused by the phased arrays of the newly constructed ultrasonic borehole probe.
Overall, the project SealWasteSafe improves the construction material, multisensor monitoring concepts and ultrasonics for quality assurance. This will help to develop safe sealing structures for nuclear waste disposal. The outcomes are particularly valuable for salt as a host rock but partly also transferrable to alternative conditions.
The internal project "SealWasteSafe" of the Federal Institute for Materials Research and Testing is dedicated to the further improvement in the construction of sealing systems for underground repositories of radioactive waste. Particularly, a multi-sensory concept is developed to ensure quality assurance and continuous long-term monitoring on the engineered barriers. Therefore, beside other measures, the temperature and equilibrium moisture of the construction shall be monitored and respective multi-sensoric monitoring concepts are tested first on the laboratory scale. One focus in this project is on embedded application in alkali-activated mortars (AAM), which results in special requirements for the resistance of the sensors to strongly alkaline environments with up to pH 14. In addition, the ingress of water along cables or at sensor positions is critical for sensors embedded in concrete, as the cable access of the sensor housing is a major weak point. It is therefore advisable to equip wireless high frequent radio frequency identification-based sensors, so called HF RFID sensors (short: RFID), that do not require cable access and thus have a stable and leak-proof sensor housing for long-term monitoring. In this contribution, the results from temperature, moisture and transmitted power monitoring of a AAM and a M2 specimens by means of HF RFID sensor systems are presented.
The Alpine Fault at the West Coast of the South Island (New Zealand) is a major plate boundary that is expected to rupture in the next 50 years, likely as a magnitude 8 earthquake. The Deep Fault Drilling Project (DFDP) aimed to deliver insight into the geological structure of this fault zone and its evolution by drilling and sampling the Alpine Fault at depth. Here we present results from a seismic survey around the DFDP-2 drill site in the Whataroa Valley where the drillhole almost reached the fault plane. This unique 3D seismic survey includes several 2D lines and a 3D array at the surface as well as borehole recordings. Within the borehole, the unique option to compare two measurement systems is used: conventional three-component borehole geophones and a fibre optic cable (heterodyne Distributed Vibration Sensing system (hDVS)). Both systems show coherent signals but only the hDVS system allowed a recording along the complete length of the borehole.
Despite the challenging conditions for seismic imaging within a glacial valley filled with sediments and steeply dipping valley flanks, several structures related to the valley itself as well as the tectonic fault system are imaged. The pre-processing of the seismic data also includes wavefield separation for the zero-offset borehole data. Seismic images are obtained by prestack depth migration approaches.
Within the glacial valley, particularly steep valley flanks are imaged directly and correlate well with results from the P-wave velocity model obtained by first arrival travel-time tomography. Additionally, a glacially over-deepened trough with nearly horizontally layered sediments is identified about 0.5 km south of the DFDP-2B borehole.
With regard to the expected Alpine fault zone, a set of several reflectors dipping 40-56° to the southeast are identified in a ~600 m wide zone between depths of 0.2 and 1.2 km that is interpreted to be the minimum extent of the damage zone. Different approaches image one distinct reflector dipping at 40°, which is interpreted to be the main Alpine Fault reflector. This reflector is only ~100 m ahead from the lower end of the borehole. At shallower depths (z<0.5 km), additional reflectors are identified as fault segments and generally have steeper dips up to 56°. About 1 km south of the drill site, a major fault is identified at a depth of 0.1-0.5 km that might be caused by the regional tectonics interacting with local valley structures. A good correlation is observed among the separate seismic data sets and with geological results such as the borehole stratigraphy and the expected surface trace of the fault.
In conclusion, several structural details of the fault zone and its environment are seismically imaged and show the complexity of the Alpine Fault at the Whataroa Valley. Thus, a detailed seismic characterization clarifies the subsurface structures, which is crucial to understand the transpressive fault’s tectonic processes.
Underground sealing structures are necessary to seal radioactive or toxic waste in underground repositories. A special version of MgO concrete is used in the mine in Teutschenthal and applied at a large-scale test with the aim to provide a low permeability barrier. The test structures (up to 10 m long) were created by shotcreting. Besides destructive tests, non-destructive ultrasonic measurements have been evaluated for quality assurance to monitor potential anomalies such as cracks, concrete inhomogeneities, and delamination. We show results of ultrasonic measurements with a multi-transducer system used at the front and from the side of the concrete structure. Images are obtained by synthetic aperture focusing techniques. The boundaries between concreting sections are not visible in the ultrasonic images systematically so that a successful concreting is assumed, which is confirmed by the low permeabilities observed. Several reflectors up to a depth of 1.2 m are identified and interpreted as potential damages in the concrete. Phase analysis of prominent reflectors reveal a negative impedance contrast thus indicating air filled voids, cracks or delamination. Boreholes through some of the identified reflectors are used to verify the results from ultrasonic measurements. Additionally, an experiment with incorporated artificial defects was undertaken to analyse the reliability of the applied methods. Overall, the conducted tests show the potential of ultrasonic measurements to detect critical anomalies. Despite challenges at small-scale structures (cm-order), large-scale anomalies can be identified. Consequently, implementing ultrasonic monitoring during and after the construction of concrete sealing structures has shown its potential as a tool for quality assurance, but needs further development and validation.
During the webinar "Dismantling and waste management: a playground for innovation" the innovative aspects of the PREDIS work package "innovations in cemented waste handling and pre-disposal storage" are presented. The webinar is jointly organised by Women in Nuclear Decommissioning (WINDI) and Women in Nuclear Innovation (WINI). The shown innovations include quality assurance (mainly NDE) and monitoring technologies with associated sensor systems, digital twin technology, and appropriate data handling including a decision framework. An overview of the on-going research in the field of pre-disposal waste management in the project Predis (WP7) is summarised.
Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures
(2023)
Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring and inspection techniques within the project SealWasteSafe.
After successful laboratory analysis on the cm-scale, cylindrical and cuboid specimens on the m-scale are produced from classical salt concrete and a specifically developed alkali-activated material. A comprehensive multi-sensory monitoring scheme is applied to compare the setting process of both materials and to demonstrate the sensors’ resistance to highly alkaline environments. Besides temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than 8 months. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete allow for wireless access to temperature and humidity measurements and are compared to conventional cabled systems. After hardening and removal of the outer casings of the specimens, further non-destructive evaluations using ultrasonic echo and thermographic measurements are conducted. Preliminary results clearly highlight differences between the tested materials, particularly showing lower acoustic emission activity for the newly developed alkali-activated material potentially indicating less phase changes or cracks.
Complementary, ultrasonic methods are improved to be used for quality assurance to detect obstacles, potential cracks and delamination at in-situ sealing structure scale. A unique large aperture ultrasonic system (LAUS) with depth penetration as large as 9 m has already successfully been applied at the test site in Morsleben, Germany, of the federal company for radioactive waste disposal (BGE). Modelling studies help to further optimize the measurement layout. Advanced imaging techniques applied to the modelled and measured data will further improve the obtained images of internal structures. Additionally, an ultrasonic borehole probe is developed and constructed using phased arrays to further enhance the detection of potential cracks. Modelling and preliminary results from laboratory specimens prove the feasibility and potential of the directional response even in heterogeneous material such as concrete. Final investigations under in-situ conditions at the test site of the sealing structure are planned.
Overall, the project SealWasteSafe improves the construction material, multi-sensory monitoring, and ultrasound for quality assurance to allow for the development of safe nuclear sealing structures. Although the techniques are tailored for sealing structures within salt as a host rock, they are transferrable to a wider field of applications and alternative disposal conditions.
Underground sealing structures are necessary to seal radioactive or toxic waste in underground repositories. Particularly developed MgO concrete is used in the mine in Teutschenthal and applied at a large-scale test with the aim to provide concrete with low permeabilities. The test structures (up to 10 m long) were created with the help of a shotcrete procedure. Besides destructive tests, non-destructive ultrasonic measurements are used for quality assurance to monitor potential anomalies such as cracks, concrete inhomogeneities, and delamination. We show results of ultrasonic measurements with a multi-transducer system used at the front site of the concrete structure. Images are obtained by synthetic aperture focusing techniques. Concreting sections are not systematically imaged so that a successful concreting is assumed as also indicated by observed low permeabilities. Several reflectors up to a depth of 1.2 m are identified and interpreted as potential damages in the concrete. Phase analysis of prominent reflectors reveal a negative impedance contrast thus indicating air filled voids, cracks or delamination. Boreholes through some of the identified reflectors are used to verify the results from ultrasonic measurements. Additionally, an experiment with incorporated defects is undertaken to analyse the reliability of the applied methods. Overall, the conducted tests show the great potential of ultrasonic measurements to detect critical anomalies. Despite challenges at small-scale structures (cm-order), large-scale anomalies can be identified. Implementing ultrasonic monitoring during and after the construction of concrete sealing structures is recommended as a tool for quality assurance.