The Large Aperture Ultrasound System (LAUS) developed at BAM is known for its ability to penetrate thick objects, especially concrete structures commonly used in nuclear waste storage and other applications in civil engineering. Although the current system effectively penetrates up to ~9 m, further optimization is imperative to enhance the safety and integrity of disposal structures for radioactive or toxic waste. This study focuses on enhancing the system’s efficiency by optimizing the transducer spacing, ensuring that resolution is not compromised. An array of twelve horizontal shear wave transducers was used to find a balance between penetration depth and resolution. Systematic adjustments of the spacing between transmitter and receiver units were undertaken based on target depth ranges of known reflectors at depth ranges from 5 m to 10 m. The trade-offs between resolution and artifact generation were meticulously assessed. This comprehensive study employs a dual approach using both simulations and measurements to investigate the performance of transducer units spaced at 10 cm, 20 cm, 30 cm, and 40 cm. We found that for depths up to 5 m, a spacing of 10 cm for LAUS transducer units provided the best resolution as confirmed by both simulations and measurements. This optimal distance is particularly effective in achieving clear reflections and a satisfactory signal-to-noise ratio (SNR) in imaging scenarios with materials such as thick concrete structures. However, when targeting depths greater than 10 m, we recommend increasing the distance between the transducers to 20 cm. This increased spacing improves the SNR in comparison to other spacings, as seen in the simulation of a 10 m deep backwall. Our results emphasize the critical role of transducer spacing in achieving the desired SNR and resolution, especially in the context of depth imaging requirements for LAUS applications. In addition to the transducer spacing, different distances between individual sets of measurement positions were tested. Overall, keeping the minimal possible distance between measurement position offsets provides the best imaging results at greater depths. The proposed optimizations for the LAUS in this study are primarily relevant to applications on massive nuclear structures for nuclear waste management. This research highlights the need for better LAUS efficiency in applications such as sealing structures, laying the foundation for future technological advances in this field.
Ultrasonic echo testing is a well-established non-destructive testing technique used to investigate the interior of concrete structures in civil engineering. For the reconstruction of internal features, methods similar to seismic imaging are applied. To improve the ultrasonic imaging capabilities, we investigate the potential of a newly available 3D matrix mode measurement device in combination with advanced imaging techniques.
Commonly used ultrasonic array measurement devices rely on several ultrasonic transducers coupled to act as one transducer that transmits or receives transversal ultrasound waves. Although this approach is well suited to detect elongated structures such as pipes and rebars, it has limitations if 3D embedded objects are present. Hence, the ultrasonic device MiraA1040Pro used here is designed to measure the ultrasonic wavefield on a 4 by 16 matrix of individual transducers. For testing, we used laboratory specimens with linear and spheric embedded structures first. Both linear and matrix mode measurements were conducted and analysed using the Synthetic Aperture Focusing Technique
(SAFT) which is similar to Kirchhoff migration. Second, we used a data set from Teutschenthal mine at a shotcrete specimen constructed to simulate engineered barriers tailored for nuclear waste repositories. Ultrasonic measurements were investigated as a tool for quality assurance of these structures. The specimen contains both artificial 3D artifacts as well as naturally occurring defects such as a delamination. To make use of the advanced data acquisition, focusing 3D imaging techniques are applied to further improve the imaging quality.
Generally, the reconstructed images from the 3D matrix mode data have a lower level of Signal-to-Noise-Ratio than the 2D linear mode because the source signal is weaker compared to the linear mode. Moreover, complex wave conversions of the SH-transversal wave occur that are reduced in the 2D linear scenario. However, clearer images can be achieved at non-linear features, particularly with focusing imaging methods. Thus, combining 3D data acquisition techniques with advanced imaging methods improves the success in imaging complex concrete structures. This is of particular interest for thick concrete structures in nuclear barrier systems or foundations. Additionally, we demonstrate opportunities to use well-constrained test laboratory scenarios from non-destructive testing as a practical test case for geophysical methods.