The numerical simulations of high power laser keyhole welding at different welding positions are performed by using Volume-Of-Fluid (VOF) method. The main material is SS400. The multi-physics phenomenon is considered using several models, such as the heat flux of Gaussian heat source, the recoil pressure with Clausisus-Clapeyron equation, the Marangoni flow considering temperature gradient, the buoyancy force with Boussinesq approximation, the additional shear stress and heat source due to metallic vapor ejected through keyhole entrance, the bubble formation assumed as adiabatic bubble, and the multiple-reflection by solving proper discriminant, are used. To analyze the fluid flow pattern, the concept of streamline formed by reconstructing the value of the velocity vector is applied.
Partial and full penetration cases at different welding positions are considered. The welding position seems to have only a minor influence on bead formation characteristics in both cases. This is probably due to the fact that the recoil pressure has a major influence when compared to other driving forces. The flow characteristics and fluid velocity in weld pool are analyzed to compare the gravity direction effect at different welding positions. It is observed that the clockwise flow pattern is mainly formed by the recoil pressure on the keyhole surface in the case of partial penetration. The laser energy can't maintain the whole weld pool when the weld pool size becomes too large. And then the solidification starts from the middle part of weld pool and a necked weld pool shape is formed. In the full penetration welding, the weld pool flow patterns are affected by the leakage of laser power through the full penetration keyhole and also by surface tension. Furthermore, the numerical simulation of full penetration welding with AISI316L is also performed to analyze the effect of material properties. The weld bead shapes obtained by simulations were compared with the corresponding experimental results to confirm the validity of the process models adopted and the CFD simulation tool.
Permeability estimation from spectral induced
polarization (SIP) measurements is based on a
fundamental premise that the characteristic relaxation
time (t) is related to the effective hydraulic radius (reff)
controlling fluid flow. The approach requires a reliable
estimate of the diffusion coefficient of the ions in the
electrical double layer. Others have assumed a value for
the diffusion coefficient, or postulated different values for
clay versus clay-free rocks. We examine the link between
t and reff for an extensive database of sandstone samples
where mercury porosimetry data confirm that reff is
reliably determined from a modification of the Hagen-
Poiseuille equation assuming that the electrical tortuosity
is equal to the hydraulic tortuosity. Our database does not
support the existence of 1 or 2 distinct representative
diffusion coefficients but instead demonstrates strong
evidence for 6 orders of magnitude of variation in an
apparent diffusion coefficient that is well correlated with
both reff and the specific surface area per unit pore
volume (Spor). Two scenarios can explain our findings:
(1) the length-scale defined by t is not equal to reff and is
likely much longer due to the control of pore surface
roughness; (2) the range of diffusion coefficients is large
and likely determined by the relative proportions of the
different minerals (e.g. silica, clays) making up the rock.
In either case, the estimation of reff (and hence
permeability) is inherently uncertain from SIP relaxation
time.
Temperature variation can be a nuisance that perturbs vibration based structural health monitoring (SHM) approaches for civil engineering structures. In this paper, temperature affected vibration data is evaluated within a stochastic damage detection framework, which relies on a null space based residual. Besides two existing temperature rejection approaches – building a reference state from an averaging method or a piecewise method – a new approach is proposed, using model interpolation. In this approach, a general reference model is obtained from data in the reference state at several known reference temperatures. Then, for a particular tested temperature, a local reference model is derived from the general reference model. Thus, a well fitting reference null space for the formulation of a residual is available when new data is tested for damage detection at an arbitrary temperature. Particular attention is paid to the computation of the residual covariance, taking into account the uncertainty related to the null space matrix estimate. This improves the test performance, contrary to prior methods, for local and global damages, resulting in a higher probability of detection (PoD) for the new interpolation approach compared to previous approaches.
Historians and librarians are interested in watermarks and mould surface patterns in historic papers, because they represent the “fingerprints” of antique papers. However, these features are usually covered or hidden by printing, writing or other media. Different techniques have been developed to extract the watermarks in the paper while avoiding interference from media on the paper. Beta radiography provides good results, but this method cannot be widely used because of radiation safety regulations and the long exposure times required due to weak isotope sources employed. In this work, two promising methods are compared which can be used to extract digital high-resolution images for paper watermarks and these are electron radiography and low energy X-ray radiography. For electron radiography a “sandwich” of a lead sheet, the paper object, and a film in a dark cassette, is formed and it is exposed at higher X-ray potentials (> 300 kV). The photoelectrons escaping from the lead sheet penetrate the paper and expose the film. After development, the film captures the watermark and mould surface pattern Images for the paper being investigated. These images are then digitized using an X-ray film digitizer. The film employed could potentially be replaced by a special type of imaging plate with a very thin protection layer to directly generate digital Images using computed radiography (CR). For the second method, a low energy X-ray source is used with the specimen paper placed on a digital detector array (DDA). This method directly generates a low energy digital radiography (DR) image. Both methods provide high quality images without interference from the printing media, and provide the potential to generate a “fingerprint”
database for historical papers. There were nevertheless found to be differences in the images obtained using the two methods.
The second method, using a low energy X-ray source, has the potential to be integrated in a portable device with a small footprint incorporating user safety requirements. Differences obtained using the two methods are shown and discussed.