For the last decades vibration based damage detection of engineering structures has become an important issue for maintenance operations on transport infrastructure. Research in vibration based structural damage detection has been rapidly expanding from classic modal parameter estimation to modern operational monitoring. Methodologies from control Engineering especially of aerospace applications have been adopted and converted for the application on civil structures. Here the difficulty is to regard to the specific environmental and operational influence to the structure under observation. A null space based damage detection algorithm is tested for its sensitivity to structural damage of a prestressed concrete road bridge. Specific techniques and extensions of the algorithm are used to overcome difficulties from the size of the structure which is associated with the number of recorded sensor channels as well as from the operational disturbances by a nearby construction site. It can be shown that for concrete bridges the proposed damage detection methodology is able to clearly indicate the presence of structural damage, if the damage leads to a significant change of the structural system. Small damage which do not result in a System change when not activated by loading, do not lead to a modification of the dynamic response behavior and for that cannot be detected with the proposed global monitoring method.
Structural health monitoring (SHM) of civil structures often is limited due to changing environmental conditions, as those changes affect the structural dynamical properties in a similar way like damages can do. In this article, an approach for damage detection under changing temperatures is presentedand applied to a beam structure. The used stochastic subspace-based algorithm relies on a reference null space estimate, which is confronted to data from the testing state in a residual function. For damage detection the residual is evaluated by means of statistical hypothesis tests. Changes of the system due to temperature effects are handled with a model interpolation approach from linear parameter varying system theory. From vibration data measured in the undamaged state at some few reference temperatures, a model of the dynamic system valid for the current testing temperature is interpolated. The reference null space and the covariance matrix for the hypothesis test is computed from this interpolated model. This approach has been developed recently and was validated in an academic test case on simulations of a mass-spring-damper. In this paper, the approach is validated experimentally on a beam structure under varying temperature conditions in a climate chamber. Compared to other approaches, the interpolation approach leads to significantly less false positive alarms in the reference state when the structure is exposed to different temperatures, while faults can still be detected reliably.