Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (35) (entfernen)
Schlagworte
- SAXS (4)
- Ultrasonic echo (4)
- Concrete (3)
- Ellipsometry (3)
- Modellierung (3)
- Radar (3)
- SAFT (3)
- Small-angle X-ray scattering (3)
- Condition assessment (2)
- Discotic Liquid Crystals (2)
Organisationseinheit der BAM
- 6 Materialchemie (5)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (3)
- 6.6 Physik und chemische Analytik der Polymere (2)
- P Präsident (2)
- P.0 Präsident und andere (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.1 Anorganische Spurenanalytik (1)
- 2 Prozess- und Anlagensicherheit (1)
- 2.1 Sicherheit von Energieträgern (1)
- 4 Material und Umwelt (1)
Paper des Monats
- ja (1)
In this work, thin iron doped tin oxide layers (3–6 nm) were investigated with regard to gas sensitivity by means of surface plasmon resonance (SPR) effect with ellipsometric readout. The experimental set-up was a Kretschmann configuration with gold as metal layer. The sensor system was exposed to different concentrations of methane in the low ppm range and the sensor response of an uncoated gold layer compared to a gold layer coated with iron doped tin oxide. The additional layer effects stability with regard to drift behavior of the sensor and an increase in sensitivity. Furthermore, the sensor is able to detect the toxic gas carbon monoxide in low concentration range (down to 0.5 ppm). The thin layers were investigated by X-ray photoelectron spectroscopy, secondary electron microscopy and spectroscopic ellipsometry. The possible mechanisms taking place on the surface are discussed.
Today's civil engineering NDT needs are for quantitative, fast to apply and easy to interpret methods. They are required on site both for evaluation of existing structures/infrastructure and for quality control in new construction. With this purpose, BAM has carried out in-situ feasibility studies, using radar, impact-echo and ultrasonic-echo methods. Two examples are given of their combined application on different railway slab–track constructions, using high frequency radar, scanning impact-echo and ultrasonic array methods. The aim was to evaluate limitations and advantages, comparability and complementarity of these methods. The on-site measurements demonstrated the possibility to investigate, with good accuracy via NDT, the bonding conditions between sleepers and slab, to locate voids and measure layer thickness. The acoustic and electromagnetic methods used, were found to be complementary.
Nano-carrier systems such as liposomes have promising biomedical applications. Nevertheless, characterization of these complex samples is a challenging analytical task. In this study a coupled hydrodynamic chromatography-single particle-inductively coupled plasma mass spectrometry (HDC-spICP-MS) approach was validated based on the technical specification (TS) 19590:2017 of the international organization for standardization (ISO). The TS has been adapted to the hyphenated setup. The quality criteria (QC), e.g., linearity of the calibration, transport efficiency, were investigated. Furthermore, a cross calibration of the particle size was performed with values from dynamic light scattering (DLS) and transmission electron microscopy (TEM). Due to an additional Y-piece, an online-calibration routine was implemented. This approach allows the calibration of the ICP-MS during the dead time of the chromatography run, to reduce the required time and enhance the robustness of the results. The optimized method was tested with different gold nanoparticle (Au-NP) mixtures to investigate the characterization properties of HDC separations for samples with increasing complexity. Additionally, the technique was successfully applied to simultaneously determine both the hydrodynamic radius and the Au-NP content in liposomes. With the established hyphenated setup, it was possible to distinguish between different subpopulations with various NP loads and different hydrodynamic diameters inside the liposome carriers.
A broad range of inorganic nanoparticles (NPs) and their dissolved ions possess a possible toxicological risk for human health and the environment. Reliable and robust measurements of dissolution effects may be influenced by the sample matrix, which challenges the analytical method of choice. In this study, CuO NPs were investigated in several dissolution experiments. Two analytical techniques (dynamic light scattering (DLS) and inductively-coupled plasma mass spectrometry (ICP-MS)) were used to characterize NPs (size distribution curves) time-dependently in different complex matrices (e.g., artificial lung lining fluids and cell culture media). The advantages and challenges of each analytical approach are evaluated and discussed. Additionally, a direct-injection single particle (DI sp)ICP-MS technique for assessing the size distribution curve of the dissolved particles was developed and evaluated. The DI technique provides a sensitive response even at low concentrations without any dilution of the complex sample matrix. These experiments were further enhanced with an automated data evaluation procedure to objectively distinguish between ionic and NP events.
With this approach, a fast and reproducible determination of inorganic NPs and ionic backgrounds can be achieved. This study can serve as guidance when choosing the optimal analytical method for NP characterization and for the determination of the origin of an adverse effect in NP toxicity.
This working paper summarises the current state of knowledge and research on the application of sensors in road pavements, designed to record input quantities and characteristics for structural assessment. In this working paper, sensors generally refer to technical equipment that can used to record the values of physical quantities and display them for interpretation.
The working paper deals with every type of sensor that is permanently connected to the road, i.e. sensors that are installed – in the bound and unbound courses of the superstructure as well as in the sub-base/sub-structure, – next to or above the road (for example on masts) and can contribute to structural recording and its subsequent assessment. This can also include sensors that are primarily used for a different purpose (e.g. traffic control). However, this working paper only describes the application of sensors that are installed primarily for other purposes for the sake of completeness; special publications (e.g. Notes on detection technologies in road traffic) are available for the respective installation situations.
The application of appropriate analytical techniques is essential for nanomaterial (NM) characterization. In this study, we compared different analytical techniques for NM analysis. Regarding possible adverse health effects, ionic and particulate NM effects have to be taken into account. As NMs behave quite differently in physiological media, special attention was paid to techniques which are able to determine the biosolubility and complexation behavior of NMs. Representative NMs of similar size were selected: aluminum (Al0) and aluminum oxide (Al2O3), to compare the behavior of metal and metal oxides. In addition, titanium dioxide (TiO2) was investigated. Characterization techniques such as dynamic light scattering (DLS) and nanoparticle tracking analysis (NTA) were evaluated with respect to their suitability for fast characterization of nanoparticle dispersions regarding a particle's hydrodynamic diameter and size distribution. By application of inductively coupled plasma mass spectrometry in the single particle mode (SP-ICP-MS), individual nanoparticles were quantified and characterized regarding their size. SP-ICP-MS measurements were correlated with the information gained using other characterization techniques, i.e. transmission electron microscopy (TEM) and small angle X-ray scattering (SAXS). The particle surface as an important descriptor of NMs was analyzed by X-ray diffraction (XRD). NM impurities and their co-localization with biomolecules were determined by ion beam microscopy (IBM) and confocal Raman microscopy (CRM). We conclude advantages and disadvantages of the different techniques applied and suggest options for their complementation. Thus, this paper may serve as a practical guide to particle characterization techniques.
Experiments according to a test specified in the UN Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, and numerical simulations by means of a finite element method are employed to determine the self-accelerating decomposition temperature of acrylic acid in a railroad tank car. The results demonstrate that the transport of acrylic acid in big tank cars is safe as long as some basic conditions are taken into account.